Referencias Diciembre 2010
Desmex – Sistemas Solares Térmicos
Grupo DESMEXInstalaciones Solar TérmicaSistema Para Agua
Caliente Sanitaria y de Proceso Industrial, Toluca
Edo. De Mexico24 KW térmicos
Grupo DESMEXInstalaciones Solar Térmica
Sistema para Agua caliente, Hotel Best Western, Zacatecas, 30 KW térmicos
Grupo DESMEXInstalaciones Solar Térmica
Sistema Para Aire Acondicionado Industrial en Monterrey, NL. 40 KW térmicos
Grupo DESMEXInstalaciones Solar Térmica
Sistema Para Calefacción de Alberca, Hacienda en San Miguel de Allende, Gto. 19.2 KW térmicos
Grupo DESMEXInstalaciones Solar Térmica
Sistema Para Calefacción de Alberca y Agua Caliente en San Miguel de Allende, Gto. 14 KW térmicos
Grupo DESMEXInstalaciones Solar Térmica
Sistema Para Agua Caliente Sanitaria, San Miguel de Allende, Gto.
Grupo DESMEXInstalaciones Solar Térmica
Instalaciones varias de Termosifones para Agua caliente Sanitaria en toda la Republica
Proyectos en Procesos
Hotel Matilda , San Miguel de Allende, GTO.
Hacienda / Hotel Ecológico Cañada de la Virgen, Gto.
Caldera Piro tubular, UNILEVER Cuernavaca.
Tequileras en Jalisco.
•The design parameters are as follows: •Design flow: 12530 Kg/Hr.•Temperature of the mixture in the condensation tank: 60°C.•Temperature of the mixture with the solar termal system: 80 °C•Required potential for the heating: 291 KW.
EXAMPLE: Tequila factory:
According to the location:
Jan Feb Mar April May June July Aug Sept Oct Nov Dec0
10,000
20,000
30,000
40,000
50,000
60,000
32,84035,304
45,86947,844 48,189
42,31744,084
42,835
37,480 36,58834,026
30,698
Useful Solar Energy
Months
KW
h
system:
1 2 3 4 5 6 7 8 9 10 11 120
10,000
20,000
30,000
40,000
50,000
60,000
70,000
Heating Demand Solar Heating
Months
Kw
h
•It is recommended the camp of the 48 parabolic collectors PTC 1800 which represent the installed capacity of 218 kW in the area of 432 m2.
•It is shown the average month solar production – data are adjusted with the meteorological data of the particular zone (Source: Meteonorm 6.1).
•Thermal energy produced by the collectors: 478073 kWh
•It is recommended the treatment by spraying the tank to adhere a layer of 3inches of isolation to conserve the produced energy.
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 260
100,000,000
200,000,000
300,000,000
400,000,000
500,000,000
600,000,000
Generación de vapor a través de energía solar"Ahorro acumulado a través del tiempo"
Ahorro acumulado
Retorno de Inversión
Año
Pes
os
[$]
Recommended