4 y 6 pulgadas ABB AQUA MASTER.pdf

Embed Size (px)

Citation preview

  • 7/28/2019 4 y 6 pulgadas ABB AQUA MASTER.pdf

    1/2

    Specification Sheet AquaMaster Electronic Water Meter

    Sizes 2 to 12

    Integral or Remote Electronic Display Unit All user display requirements in a single unit

    Submersible sensor and Electronic Display Unit Facilitates installation in all locations

    including flooded pits.

    Buriable sensor Eliminates chamber and ensures fast, low cost

    installation

    Wetted materials

    Lining Elastomer (UKWFBS Listed)

    Electrodes Stainless steel 316 L

    Pressure LimitationsAs flange rating

    Temperature LimitationsMedia (water) 14 - 158F

    Ambient -4 - 140FStorage -22 - 158F

    Conductivity> 50mS/cm

    End Connections

    FlangedANSI B 16.5 1.5 Class 150

    Description

    AquaMasters Principle of OperationIt measures flow of water in pipes by using Faradays princi-

    ple of magnetic induction: a conductor (water) movingthrough a magnetic field will induce an electric current pro-portional to the velocity of the conductor. Water volume

    through the meter can then be easily calculated.

    Widest flow range, highest accuracy(up to 1500:1 turndown) Measures minimal night and peak day flows

    Lowest cost of ownership

    Rugged construction with no moving parts Ensures long, maintenance free life

    Fit and Flow Foolproof installation; no on-site setup

    Battery operation 3 year life

    No external power supply required, facilitatesinstallation in remote locations

    Operational temperature limits of the battery forspecified battery life: 32 - 122F

    AC powered with optional battery backup Continuous measurement even during power-down

  • 7/28/2019 4 y 6 pulgadas ABB AQUA MASTER.pdf

    2/2

    Meter Sizes, Flow Rates and Accuracies

    ABB Water Meters, Inc.

    www.abb.com/metering

    United States Canada Caribbean Mexico

    P. O. Box 1852 1200 Aerowood Drive -#35 P. O. Box 225 Calle Union 30Ocala, FL 34478-1852 Mississauga, Ontario L4W 2S7 Carretera 112 KM 2.3 Col. Tlatilco

    352-732-4670 FAX 352-368-1950 905-238-9622 Isabela, PR 00662 Del. AzcapotalcoOutside Florida: 800-874-0890 800-670-5368 787-872-2006 CP 02860 MexicoInside Florida: 800-356-6829 FAX 905-238-5640 FAX 787-872-5427 52 53 56 3866

    E-mail: [email protected] E-mail: [email protected] FAX 52 53 56 10 17

    The companys policy is one of continuous productimprovement and the right is reserved to modify thespecifications contained herein without notice. Theseproducts have been manufactured with current tech-nology and in accordance with applicable AWWAStandards.

    2001 ABB Water Meters, Inc. All rights reserved.

    Flow Direction

    >5 x pipe dia.

    minimum

    >2 x pipe dia.

    minimum

    45

    Maximum

    Sensor

    Electrodes

    Mounting

    95% - 102%(GPM)

    98% - 102%(GPM)

    99.75% -

    100.25%

    (GPM)

    95% - 102%(GPM)

    98% - 102%(GPM)

    99.50% -

    100.50%

    (GPM)

    2 219 177 7.80 0.17 0.40 3.3 0.40 1.0 10

    3 756 609 13.00 0.44 1.1 9 1.1 2.6 26

    4 1,268 1,022 16.25 0.7 1.6 13 1.6 4.0 40

    6 2,838 2,287 13.00 1.7 4.0 33 4.0 10 99

    8 3,658 2,948 7.80 2.8 7 55 7 17 165

    10 5,855 4,718 7.80 4.4 11 88 11 26 264

    12 8,015 6,460 6.50 7 16 132 16 40 396

    Low Flow Accuracy AC Powered

    MetersMax.

    Flow

    (GPM)

    Size

    (in.)

    Cont.

    Flow

    (GPM)

    Pressure

    Drop (PSI)

    at Cont.Flow

    Low Flow Accuracy Battery Powered

    Meters (Inc. standby battery)

    AM-Meter/03-01

    Installation

    Pipe Conditions

    Nominal Dimensions

    Meter Dimensions Approx.

    Size A B Weight (lbs)2 7.0 7.9 22

    3 8.6 7.9 404 9.1 9.8 53

    6 11.1 11.8 978 15.8 13.8 112

    10 17.3 17.7 132

    12 18.9 19.7 154

    BA

    ABB