Capacidad: 202 a 1,393 toneladas (605 a 4,179 GPM @ 95°F/ 85°F / 78°F) Disponible en galvanizado, galvanizado con recubrimiento epóxico para ambiente marino o acero inoxidable Bajo costo de instalación y operación Bajo nivel de sonido y vibración Baja potencia de consumo por tonelada Fácil mantenimiento TORRE DE ENFRIAMIENTO DOBLE FLUJO CRUZADO DE TIRO INDUCIDO Más de 4,000 torres instaladas en México y el mundo

(605 a 4,179 GPM @ 95°F/ 85°F / 78°F) TORRE DE ...industrialmexicana.com/wp-content/uploads/2016/02/IM_OneSheet_1000_v3-1.pdfmontados de la torre para permitir operaciones de man-tenimiento

  • Upload
    others

  • View
    0

  • Download
    0

Embed Size (px)

Citation preview

Page 1: (605 a 4,179 GPM @ 95°F/ 85°F / 78°F) TORRE DE ...industrialmexicana.com/wp-content/uploads/2016/02/IM_OneSheet_1000_v3-1.pdfmontados de la torre para permitir operaciones de man-tenimiento

Capacidad: 202 a 1,393 toneladas (605 a 4,179 GPM @ 95°F/ 85°F / 78°F)

Disponible en galvanizado, galvanizado con recubrimiento epóxico para ambiente marino o acero inoxidable

Bajo costo de instalación y operación

Bajo nivel de sonido y vibración

Baja potencia de consumo por tonelada

Fácil mantenimiento

TORRE DE ENFRIAMIENTO DOBLE FLUJO CRUZADO

DE TIRO INDUCIDO

Más de 4,000 torres instaladas en México y el mundo

Page 2: (605 a 4,179 GPM @ 95°F/ 85°F / 78°F) TORRE DE ...industrialmexicana.com/wp-content/uploads/2016/02/IM_OneSheet_1000_v3-1.pdfmontados de la torre para permitir operaciones de man-tenimiento

SERIES 1000

Relleno laminar de PVC de alta eficiencia

El ventilador axial de aluminio de alta eficiencia equipado con aspas flexibles de ángulo ajustable elimina por completo frecuencias de resonancia.

Además, la utilización de “T-Caps” y aros de ven-tilación de FRP con entrada de aire redondeada incrementan la eficiencia y reducen el nivel de sonido y de vibración.

Rociadores de turbina giratoria vs. rociadores estacionarios de orificio fijo

Las torres IM pueden operar entre el 20% y el 100% de su capacidad hidráulica. Dentro de un sistema integral esto puede representar un ahorro significativo en energía.

Bajo nivel desonido y vibración

Reductor de velocidadMotor protegido

Unión de puente con soportede equipo mecánico y sistema de distribución de agua caliente

Estructura de marco auto-soportable

Doble pared

VENTAJAS IM

Page 3: (605 a 4,179 GPM @ 95°F/ 85°F / 78°F) TORRE DE ...industrialmexicana.com/wp-content/uploads/2016/02/IM_OneSheet_1000_v3-1.pdfmontados de la torre para permitir operaciones de man-tenimiento

SERIES 1000

Estructura de marco auto-soportante Incluida en la Serie 1000, no requiere ser montada sobre estructura de vigas de soporte lo cual representa un aho-rro en sus costos de instalación.

Relleno laminar de PVC de alta eficiencia Apoyado en piso, con eliminadores de goteo y de arrastre integrados. Puede ser reemplazado sin necesidad de des-armar la torre.

Reductor de velocidadEl sistema motriz IM® con Reductor de Velocidad, en lugar de bandas y poleas. Se conecta directamente al motor por un cople flexible que garantiza una mayor duración libre de problemas de mantenimiento y ajustes.

Motor protegidoMotor eléctrico TEFC de alta eficiencia operando dentro de un compartimento de FRP de ambiente seco, el cual alarga la vida útil del mismo y reduce el nivel de ruido.

Rociadores de turbina giratoria vs. rociadores estacionarios de orificio fijoLos rociadores de turbina giratoria (A) con orificio variable a presión compensada utilizados en las torres IM proveen un patrón de distribución “cuadrado”, uniforme y cons-tante independientemente del caudal de agua procesa-do.

Los rociadores estacionarios de orificio fijo (B) utilizados por otros equipos proveen patrones de dispersión cóni-cos no uniformes que crean áreas secas y áreas con sobre-carga de agua, los cuales varían respondiendo a variacio-nes del caudal.

Unión de puente con soporte de equipo mecánico y sistema de distribución de agua caliente

Requiere una sola alimentación de agua caliente a la torre, lo que permite la interconexión de múltiples torres sin re-querir válvulas de regulación de caudal y reduce el costo de instalación.

La masa de agua dentro del tubo de torque reduce la pro-pagación de ruido del equipo mecánico a la estructura de la torre y por lo tanto, al edificio.

Los múltiples rociadores del sistema de distribución de agua (de PVC) pueden ser rotados a 90° o fácilmente des-montados de la torre para permitir operaciones de man-tenimiento.

Operación con caudal variableDebido a su Sistema de distribución de agua presurizado (2.3 – 4.5 psi) con rociadores de turbina giratoria y orificio variable (ajuste automático de caudal de agua), la torre puede operar entre el 20% y el 100% de su capacidad hi-dráulica de diseño conservando el patrón de distribución de agua sobre el relleno.

Doble paredLa pared plana interior en el área del relleno minimiza las “pérdidas por pared”, incrementando la eficiencia de la torre.

VENTAJAS IM®

Page 4: (605 a 4,179 GPM @ 95°F/ 85°F / 78°F) TORRE DE ...industrialmexicana.com/wp-content/uploads/2016/02/IM_OneSheet_1000_v3-1.pdfmontados de la torre para permitir operaciones de man-tenimiento

SERIES 1000

ODX-1000-0241-X-HODX-1000-0266-X-HODX-1000-0301-X-SODX-1000-0330-X-S

ODX-1000-0294-X-HODX-1000-0340-X-HODX-1000-0375-X-HODX-1000-0400-X-H

ODX-1000-0413-X-SODX-1000-0440-X-S

ODX-1000-0354-X-HODX-1000-0405-X-HODX-1000-0447-X-HODX-1000-0480-X-SODX-1000-0507-X-S

ODX-1000-0459-X-HODX-1000-0506-X-HODX-1000-0549-X-HODX-1000-0583-X-S

ODX-1000-0585-X-HODX-1000-0625-X-SODX-1000-0682-X-SODX-1000-0705-X-S

ODX-1000-0727-X-SODX-1000-0790-X-SODX-1000-0833-X-SODX-1000-0875-X-S

ODX-1000-0808-X-SODX-1000-0852-X-SODX-1000-0880-X-SODX-1000-0955-X-S

ODX-1000-0885-X-HODX-1000-0937-X-SODX-1000-0990-X-SODX-1000-1070-X-S

ODX-1000-1250-X-SODX-1000-1348-X-SODX-1000-1465-X-S

7,012.847,096.047,117.357,150.89

7,570.747,653.057,794.197,999.15

8,727.238,932.19

10,256.4010,446.3110,479.8510,684.8110,739.81

11,885.4711,919.0112,118.8912,098.68

12,418.2612,498.8312,834.3812,887.34

14,753.9314,799.9314,973.3115,039.31

15,597.3015,643.3015,816.6816,090.23

17,399.6017,451.1417,625.0117,896.72

21,327.2921,395.8521,756.52

10,938.9011,022.1011,043.4111,076.95

12,291.0812,373.3912,514.5312,719.49

14,360.5714,565.53

17,161.4017,351.3117,384.8517,589.8117,644.81

20,415.3420,448.8820,648.7620,628.55

20,968.8521,049.4221,535.4521,588.41

22,930.1622,976.1622,968.9623,034.96

24,762.9324,808.9324,982.3125,075.28

26,496.6126,548.1526,722.0226,993.73

32,478.3932,546.9532,907.62

7.5101520

10152025

2025

1015202530

15202530

25304050

40506075

40506075

40506075

6075

100

202224259285

252294328356

358391

297351394431461

382432474510

513552622665

681726774788

736798853909

838908967

1,042

1,1711,2631,393

3,030,0003,360,0003,885,0004,275,000

3,780,0004,410,000 4,920,000 5,340,000

5,370,000 5,865,000

4,455,0005,265,0005,910,0006,465,0006,915,000

5,730,0006,480,0007,110,0007,650,000

7,695,0008,280,0009,330,0009,975,000

10,215,00010,890,00011,610,00011,820,000

11,040,00011,970,00012,795,00013,635,000

12,570,00013,620,00014,505,00015,630,000

17,565,00018,945,00020,895,000

605672778855

755882985

1,067

1,0751,172

8901,0541,1831,2921,382

1,1471,2951,4221,531

1,5401,6571,8651,995

2,0442,1782,3212,364

2,2082,3952,5582,726

2,5152,7252,9023,125

3,5123,7904,179

203.5203.5203.5203.5

219.75219.75219.75219.75

232232

280280280280280

292292292292

292292295295

294294294294

294294294294

294294294294

318318318

104104104104

116116116116

128128

128128128128128

150.5150.5150.5150.5

150.5150.5150.5150.5

140140140140

150.5150.5150.5150.5

150.5150.5150.5150.5

170170170

144.13144.13144.13144.13

147.13147.13147.13147.13

147.13147.13

147.13147.13147.13147.13147.13

149.1149.1149.1149.1

162.13162.13164.19164.19

205.88205.88205.88205.88

205.88205.88205.88205.88

226.69226.69226.69226.69

284.5284.5284.5

MODEL MOTORHP

WEIGHT (LBS.) Approx.

Shipping Operation

DIMENSIONS (Inches)

W L H

NOMINAL CAPACITY

Tons BTU/hr GPM

DOBLE FLUJO CRUZADO DE TIRO INDUCIDO

IM SERIE 1000Capacidad nominal605 a 4,179 GPM @ 95°F / 85°F / 78°F

Page 5: (605 a 4,179 GPM @ 95°F/ 85°F / 78°F) TORRE DE ...industrialmexicana.com/wp-content/uploads/2016/02/IM_OneSheet_1000_v3-1.pdfmontados de la torre para permitir operaciones de man-tenimiento

SERIES 1000

Mantenimiento IM

En Industrial Mexicana te ofrecemos el mantenimiento que tu torre requiere.

El mantenimiento Básico implica la instalación de un equipo de tratamiento de agua Silver Bullet® definido por el volumen de agua a tratar de la torre.

Básico Silver Bullet®

Plus Silver Bullet® + Mecánico

El mantenimiento Plus incluye la instalación del equipo Silver Bullet® y además todos los mantenimientos mecánicos de la torre.

Silver Bullet + Mecánico+ Equipos periféricos

El mantenimiento Ultra cubre además los equipos periféricos, como los son bombas del loop, caldera, tanques de agua caliente, intercambiadores de placas, entre otros.

Ultra

Cuenta con IM para echar andar de nuevo tu torre. Hacemos reparaciones totales, desde las refacciones hasta el servicio mecánico. Ponte en contacto con uno de nuestros expertos.

Reparaciones mayores

Te ofrecemos una amplia gama de partes y refacciones para torres IM y otras marcas.

Refacciones

Silver Bullet es un sistema de tratamiento de agua sin químicos que evita bacterias, incrustación de sales y corrosión en tu torre, lo que resulta en eficiencia y ahorro de energía.

Page 6: (605 a 4,179 GPM @ 95°F/ 85°F / 78°F) TORRE DE ...industrialmexicana.com/wp-content/uploads/2016/02/IM_OneSheet_1000_v3-1.pdfmontados de la torre para permitir operaciones de man-tenimiento

SERIES 1000

Líderes en la industria a través de la innovación

Ahorro en energíaConforme el costo de la energía continúa en ascenso, se ha puesto un mayor énfasis en la reducción en el consumo de energía de los equipos industriales. Por esto, las torres de enfriamiento IM® han sido diseñadas para lograr una capa-cidad máxima de rendimiento térmico por unidad. Son efi-cientes tanto en términos de consumo de energía del ven-tilador, así como en el consumo de energía de la bomba de recirculación, al incorporar en su diseño la carga estática de bombeo más baja del mercado.

Ahorro en aguaEn la actualidad, la industria consume grandes cantidades de agua solo para enfriamiento. Las torres IM® utilizan el princi-pio de evaporación para permitir el reciclaje, reduciendo la demanda del suministro de agua natural y municipal.

Las torres de enfriamiento IM® incorporan en su diseño im-portantes características para reducir el desperdicio tanto de agua como de químicos de tratamiento, con el empleo de los materiales y componentes más modernos para mini-mizar el salpiqueo y el arrastre.

Larga vida a tu productoLas torres de enfriamiento deben trabajar a su máxima ca-pacidad en una gama variada de condiciones de operación, incluyendo cambios bruscos de temperatura, y diversidad en la calidad de agua, viento y cargas sísmicas. Conside-rando esto, Industrial Mexicana ha tomado el liderazgo tecnológico en el tratamiento químico de la madera, como también en el diseño de robustas estructuras. Esto último se ha logrado utilizando acero o perfiles extruidos de fibra de vidrio, métodos de análisis estructural, e ingeniería de ma-teriales y componentes para ofrecer a los clientes un funcio-namiento confiable y duradero del equipo.

Diseño e innovaciónEstamos en investigación continua y de-sarrollamos soluciones únicas para to-rres de enfriamiento. Nuestros esfuerzos están siempre orientados a eficiencia, desempeño y ahorro. Esa determina-ción es lo que nos ha llevado lejos.

Servicio y experienciaMás de 55 años de experiencia lo dicen todo, hemos trabajado exito-samente en todas las industrias y tenemos la capacidad para solucionar cualquier situación. Nuestra misión es fabricar las mejores torres y man-tenerlas trabajando eficientemente.

Automatización y ahorro de energíaLa automatización es el futuro y en IM hemos desarrollado controladores de punta para que tus torres funcionen de la manera más eficiente todo el tiempo, aportando así ahorros energéticos que benefician a todos.

En IM trabajamos para ti