2
Totally Integrated Automation Portal ARRANQUE CON AUTOTRANSFORMADOR CON TRANSICION A CIRCUITO ABIERTO PARA MOTORES JA / PLC_1 [CPU 314C-2 PN/DP] / Bloques de programa Main [OB1] Main Propiedades General Nombre Main Número 1 Tipo OB Idioma KOP Información Título "Main Program Sweep (Cycle)" Autor Comentario Familia Versión 0.1 ID personali‐ zada Nombre Tipo de datos Offset Temp tiempo Time 0.0 OB1_EV_CLASS Byte 4.0 OB1_SCAN_1 Byte 5.0 OB1_PRIORITY Byte 6.0 OB1_OB_NUMBR Byte 7.0 OB1_RESERVED_1 Byte 8.0 OB1_RESERVED_2 Byte 9.0 OB1_PREV_CYCLE Int 10.0 OB1_MIN_CYCLE Int 12.0 OB1_MAX_CYCLE Int 14.0 OB1_DATE_TIME Date_And_Time 16.0 Segmento 1: "PARO CERRADO" %I136.0 %I136.0 "ARRANQUE" %I136.1 %I136.1 "OL - CERRADO" %I136.2 %I136.2 "CR" %M0.0 %M0.0 "CR" %M0.0 %M0.0 Segmento 2: TON Time "CR" %M0.0 %M0.0 "IEC_Timer_0_DB" %DB1 %DB1 T#6S #tiempo "TR" %Q136.0 %Q136.0 IN PT Q ET Time Segmento 3:

Arranque con autotranasformador con transicion a circuito abierto para motores JA.pdf

Embed Size (px)

Citation preview

  • Totally Integrated

    Automation Portal

    ARRANQUE CON AUTOTRANSFORMADOR CON TRANSICION A CIRCUITOABIERTO PARA MOTORES JA / PLC_1 [CPU 314C-2 PN/DP] / Bloques deprograma

    Main [OB1]

    Main Propiedades

    General

    Nombre Main Nmero 1 Tipo OB

    Idioma KOP

    Informacin

    Ttulo "Main Program Sweep(Cycle)"

    Autor Comentario

    Familia Versin 0.1 ID personalizada

    Nombre Tipo de datos Offset

    Temp

    tiempo Time 0.0

    OB1_EV_CLASS Byte 4.0

    OB1_SCAN_1 Byte 5.0

    OB1_PRIORITY Byte 6.0

    OB1_OB_NUMBR Byte 7.0

    OB1_RESERVED_1 Byte 8.0

    OB1_RESERVED_2 Byte 9.0

    OB1_PREV_CYCLE Int 10.0

    OB1_MIN_CYCLE Int 12.0

    OB1_MAX_CYCLE Int 14.0

    OB1_DATE_TIME Date_And_Time 16.0

    Segmento 1:

    "PARO CERRADO"%I136.0%I136.0

    "ARRANQUE"%I136.1%I136.1

    "OL - CERRADO"%I136.2%I136.2

    "CR"%M0.0%M0.0

    "CR"

    %M0.0%M0.0

    Segmento 2:

    TON

    Time"CR"

    %M0.0%M0.0

    "IEC_Timer_0_DB"

    %DB1%DB1

    T#6S #tiempo

    "TR"

    %Q136.0%Q136.0

    IN

    PT

    Q

    ET

    Time

    Segmento 3:

  • Totally Integrated

    Automation Portal

    "TR"

    %Q136.0%Q136.0

    "2S"

    %Q136.1%Q136.1

    "CR"

    %M0.0%M0.0

    "1S"

    %Q136.2%Q136.2

    Segmento 4:

    TON

    Time"1S"

    %Q136.2%Q136.2

    "TR"

    %Q136.0%Q136.0

    "IEC_Timer_0_DB_1"

    %DB2%DB2

    T#5ms #tiempo

    "2S"

    %Q136.1%Q136.1

    IN

    PT

    Q

    ET

    Time

    Segmento 5:

    "2S"

    %Q136.1%Q136.1

    "LUZ ROJA"

    %Q136.3%Q136.3

    Segmento 6:

    "OL - ABIERTO"

    %I136.3%I136.3

    "LUZ VERDE"

    %Q136.4%Q136.4