10
CALCULO DEL PESO TOTAL DE LA ESTRCTURA I.- DATOS DE LA ESTRUCTURA Tipicos P. Aligerado = 300.00 kg/m2 Area Planta = 59.09 m2 P. Muro ladril ### kg/m3 Altura de Entrepiso = 2.80 m Acabado Piso T 100.00 kg/m2 S/Carg 1,2,3y4 200.00 kg/m2 S/Carga Azotea 150.00 kg/m2 Vigas Vigas Principa 0.25 0.20 Longitud= 35.29 m Area = 8.823 m2 Vigas Secundar 0.25 0.2 Longitud= 14.90 m Area = 3.725 m2 Columnas Columna C-1 = 0.30 0.30 Numero = 6 Area = 0.090 m2 Total= 0.54 m2 Columna C-2 = 0.30 0.30 Numero = 2 Area = 0.090 m2 Total= 0.18 m2 0.40 0.15 Numero = 2 Area = 0.060 m2 Total= 0.12 m2 Columna C-3 = 0.60 0.15 Numero = 2 Area = 0.090 m2 Total= 0.18 m2 Columna C-4 = 1.20 0.15 Numero = 2 Area = 0.180 m2 Total= 0.36 m2 Columna C-5 = 0.30 0.15 Numero = 2 Area = 0.045 m2 Total= 0.09 m2 Columneta Azot 0.25 0.25 Numero = 14 Area = 0.063 m2 Total= 0.875 m2 A. Colum Muros Niveles 2°,3°,4 y 5° Long Muros X-X 20.50 m pesor = 0.15 m h = 2.50 m Area = 3.075 m2 Long Muros Y-Y 10.91 m pesor = 0.15 m h = 2.50 m Area = 1.637 m2 Nivel 1° Long Muros X-X 27.11 m pesor = 0.15 m h = 2.50 m Area = 4.067 m2 Long Muros Y-Y 10.91 m pesor = 0.15 m h = 2.50 m Area = 1.637 m2 Azotea Long Muros h= 13.02 m pesor = 0.15 m h = 2.20 m Area = 1.953 m2 Long Muro h=0. 20.95 m pesor = 0.15 m h = 0.90 m Area = 3.143 m2 II. CALCULO DEL PESO Peso 1° Peso de la Losa Aliger (Area Planta - Area de Vigas - Area de Columnas)*Pe = 45.07 ### 13.52 Peso de Acabados = (Area Planta - Area de Columnas - Area de Muros ) 52.91 ### 5.29 Peso de Vigas ( Base x Altura x Longitud ) x 2.4 Tn/m3 0.25 0.20 35.29 2.40 4.23 0.25 0.20 14.90 2.40 1.79 Peso de Column N° x Largo x Ancho x Altura x 2.4Tn/m3 6.00 0.30 0.30 1.40 2.40 1.81 2.00 0.30 0.30 1.40 2.40 0.60 2.00 0.40 0.15 1.40 2.40 0.40 2.00 0.60 0.15 1.40 2.40 0.60 2.00 1.20 0.15 1.40 2.40 1.21 2.00 0.30 0.15 1.40 2.40 0.30 14.0 0.25 0.25 0.90 2.40 1.89 Peso de Muros = Largo x Ancho x Altura x Peso Especifico 20.50 0.15 1.25 1.80 6.92 10.91 0.15 1.25 1.80 3.68 Peso de Muros en la Azotea 13.02 0.15 2.20 1.80 7.73 20.95 0.15 0.90 1.80 5.09 Total Carga Muerta = 90.30 Peso de Sobrecarga = 25%xS/Carga x (Area Planta-Area de Columnas-Area M 0.25 0.15 ### 5.95 T O T A L = 96.25 Peso Niveles 2° Peso de la Losa Aliger (Area Planta - Area de Vigas - Area de Columnas)*Pe = 45.07 ### 13.52 Peso de Acabados = (Area Planta - Area de Columnas - Area de Muros ) 52.91 ### 5.29 Peso de Vigas ( Base x Altura x Longitud ) x 2.4 Tn/m3 0.25 0.20 35.29 2.40 4.23 0.25 0.20 14.90 2.40 1.79 Peso de Column x Largo * Ancho x Altura x 2.4 Tn/m3 6.00 0.30 0.30 2.80 2.40 3.63 2.00 0.30 0.30 2.80 2.40 1.21 Area Vigas = Area Columna = Area Muro = Area Muro = Area Muro =

Cortante Basal de albañileria

Embed Size (px)

DESCRIPTION

cortante basal de casa de albañileria confinada 2 pisos

Citation preview

Metrado NivelesCALCULO DEL PESO TOTAL DE LA ESTRCTURAI.-DATOS DE LA ESTRUCTURATipicosP. Aligerado =300.00kg/m2Area Planta =59.09m2P. Muro ladrillo=1800.00kg/m3Altura de Entrepiso =2.80mAcabado Piso Ter=100.00kg/m2S/Carg 1,2,3y4 Niv. =200.00kg/m2S/Carga Azotea =150.00kg/m2VigasVigas Principales =0.250.20Longitud=35.29mArea =8.823m2Area Vigas =12.55m2Vigas Secundarias =0.250.2Longitud=14.90mArea =3.725m2ColumnasColumna C-1 =0.300.30Numero =6Area =0.090m2Total=0.54m2Columna C-2 =0.300.30Numero =2Area =0.090m2Total=0.18m20.400.15Numero =2Area =0.060m2Total=0.12m2Area Columna=1.47m2Columna C-3 =0.600.15Numero =2Area =0.090m2Total=0.18m2Columna C-4 =1.200.15Numero =2Area =0.180m2Total=0.36m2Columna C-5 =0.300.15Numero =2Area =0.045m2Total=0.09m2Columneta Azotea =0.250.25Numero =14Area =0.063m2Total=0.875m2A. Colum0.875m2MurosNiveles 2,3,4 y 5Long Muros X-X =20.50mEspesor =0.15mh =2.50mArea =3.075m2Area Muro =4.71m2Long Muros Y-Y =10.91mEspesor =0.15mh =2.50mArea =1.637m2Nivel 1Long Muros X-X =27.11mEspesor =0.15mh =2.50mArea =4.067m2Area Muro =5.70m2Long Muros Y-Y =10.91mEspesor =0.15mh =2.50mArea =1.637m2AzoteaLong Muros h=2.2013.02mEspesor =0.15mh =2.20mArea =1.953m2Area Muro =5.10m2Long Muro h=0.90m20.95mEspesor =0.15mh =0.90mArea =3.142m2II.-CALCULO DEL PESOPeso 1Peso de la Losa Aligerada =(Area Planta - Area de Vigas - Area de Columnas)*Pe =45.07300.0013.52TnPeso de Acabados = (Area Planta - Area de Columnas - Area de Muros )52.91100.005.29TnPeso de Vigas =( Base x Altura x Longitud ) x 2.4 Tn/m30.250.2035.292.404.23Tn0.250.2014.902.401.79TnPeso de Columnas =N x Largo x Ancho x Altura x 2.4Tn/m36.000.300.301.402.401.81Tn2.000.300.301.402.400.60Tn2.000.400.151.402.400.40Tn2.000.600.151.402.400.60Tn2.001.200.151.402.401.21Tn2.000.300.151.402.400.30Tn14.00.250.250.902.401.89TnPeso de Muros = Largo x Ancho x Altura x Peso Especifico20.500.151.251.806.92Tn10.910.151.251.803.68TnPeso de Muros en la Azotea13.020.152.201.807.73Tn20.950.150.901.805.09TnTotal Carga Muerta =90.30TnPeso de Sobrecarga = 25%xS/Carga x (Area Planta-Area de Columnas-Area Muros)=0.250.15158.555.95TnT O T A L =96.25TnPeso Niveles 2Peso de la Losa Aligerada =(Area Planta - Area de Vigas - Area de Columnas)*Pe =45.07300.0013.52TnPeso de Acabados = (Area Planta - Area de Columnas - Area de Muros )52.91100.005.29TnPeso de Vigas =( Base x Altura x Longitud ) x 2.4 Tn/m30.250.2035.292.404.23Tn0.250.2014.902.401.79TnPeso de Columnas =N x Largo * Ancho x Altura x 2.4 Tn/m36.000.300.302.802.403.63Tn2.000.300.302.802.401.21Tn2.000.400.152.802.400.81Tn2.000.600.152.802.401.21Tn2.001.200.152.802.402.42Tn2.000.300.152.802.400.60TnPeso de Muros = Largo x Ancho x Altura x Peso Especifico20.500.152.501.8013.84Tn10.910.152.501.807.36TnTotal Carga Muerta =86.77TnPeso de Sobrecarga = 25%xS/Carga x (Area Planta-Area de Columnas-Area Muros)=0.250.15158.555.95TnT O T A L =92.71TnRESUMEN GENERAL DE PESOS POR CADA NIVELArea Planta =158.55m2Nivel 2Carga Muerta90.30TnPeso Carga Muerta/m2 =0.57Tn/m2Carga Viva23.78TnPeso Carga Viva/m2 =0.15Tn/m2Nivel 1Carga Muerta86.77TnPeso Carga Muerta/m2 =0.55Tn/m2Carga Viva23.78TnPeso Carga Viva/m2 =0.15Tn/m2DENSIDAD DE MUROS REFORZADOSDIRECCION X-XDIRECCION Y-YMUROL(m)t(m)Ac(m2)CantidadMUROL(m)t(m)Ac(m2)CantidadX11.40.130.1822Y123.150.133.00952X24.90.130.6372Y21.650.130.21452X31.350.130.17554Y310.130.132X42.430.130.31591Y44.50.130.5851X51.690.130.21971Y51.20.130.1561X63.450.130.44851Y61.30.130.1691AREA TIPICA158.55Y71.50.130.1951AREA TIPICA158.55DENSIDAD MAXIMA0.0124793441DENSIDAD MAXIMA0.0281236203

Fuerza CortanteFUERZA CORTANTE EN LA BASE-ALBAILERIA CONFINADA(2 PISOS)V=ZUCS PPARAMETROS SISMICOSRZ=0.40Tp=0.90U=1.00P=188.96S=1.40hn=6.25SISMO EN XXSISMO EN YYDATOSR =3DATOSR =3Ct =60Ct =60Tx = hn/Ct =0.104seg.Ty = hn/Ct =0.104seg.C=2.5 (Tp/T); C =0.1Total188.966.25C/R0.83C/R0.83Vxx =88.18tonVyy =88.18tonFUERZA POR PISOFi =Pi . Hi . VE Pi. HiDireccin X-XDireccin Y-YPisohiPiPi . HiFiFi'ViPisohiPiPi . HiFiVi50.000.000.000.000.000.0050.000.000.000.000.0040.000.000.000.000.000.0040.000.000.000.000.0030.000.000.000.000.000.0030.000.000.000.000.0022.8592.71264.240.4539.3939.3922.8592.71264.2439.3939.3913.4096.25327.240.5548.7988.1813.4096.25327.2448.7988.18TOTAL591.471.00TOTAL591.4788.18CALCULO DE LA EXCENTRICIDAD5% (Norma E030)DireccionDistanciaExcentricSismo XXmm7XX7.000.35Sismo YYYY22.651.1322.65EFECTOS DE TORSION : Mt= +/- Fi x eFuerzas HorizontalesMomento TorsorNiv. 1Niv. 2Niv. 1Niv. 2Sismo X10.5530.4470.1940.156Sismo X20.5530.447-0.194-0.156Sismo y148.78739.39455.25144.614Sismo y248.78739.394-55.251-44.614DATOS PARA EL ANALISIS DINAMICONIVELX cm (m)Y cm (m)Peso(Tn)Masa (Tn.seg2/m)Inercia I (m4)Inercia J (m4)Suma Inercia (m4)Area Planta (m2)Inercia /AreaInercia de Masa (Tn.seg2.m)54.18683.80130.000.00252.83341.38594.2159.4210.000.0044.18683.80130.000.00252.83341.38594.2159.4210.000.0034.18683.80130.000.00252.83341.38594.2159.4210.000.0024.18683.801392.719.45252.83341.38594.2159.4210.0094.5114.18683.801396.259.81252.83341.38594.2159.4210.0098.11Nota .- Con estos Datos y la Aceleracion Espectral del Edificio se Utiliza el Programa de Calculo SAP - 2000 paraCalcular los Esfuerzos por Sismo

EspectroCALCULO DEL ESPECTRO DE ACELERACION SISMICA DEL EDIFICIOZ =0.40C=2.5 (Tp/T)U =1.00S =1.40Tp =0.90Sa=ZUSC/ R gg =9.81R =3.00CTSa2.50000.014.582.50000.104.582.50000.404.582.50000.604.582.50000.704.582.50000.804.582.50000.904.582.25001.004.121.87501.203.431.60711.402.941.40631.602.581.25001.802.291.12502.002.060.93752.401.720.80362.801.470.70313.201.290.62503.601.140.50004.500.920.45005.000.820.37506.000.690.32147.000.590.25009.000.460.225010.000.410.187512.000.340.150015.000.27

Espectro

Espectro de AceleracionPeriodo T (seg)Espectro Acel : (Sa)Espectro de Aceleracion

PREDIMENSIONADO Predimensionado de Muros:t= h/20hth 1piso:3.400.17h 2piso:2.850.1425Asuminos t= 0.13que es el espesor efectivo de un ladrillo de sogaLas dimensiones de la estructura como columnas de confinamiento y vigas soleras seran de acuerdo a la norma E070