HAZ of Elec

Embed Size (px)

Citation preview

  • 8/12/2019 HAZ of Elec

    1/27

    ELECTRICALSAFETYPresentation by:

  • 8/12/2019 HAZ of Elec

    2/27

    Causes o f ELECTRICAL HAZARDS

    Can be div ided into three main g roups

    Power Electricity

    Static Electricity

    Lightning

  • 8/12/2019 HAZ of Elec

    3/27

    W hat are we going to discuss?Hazards caused by Power Electricity

    Major factors governing electrical hazards

    Broad classification of electrical accidents

    Portable electrical tools

    OH & UG Distribution

    Major factors causing electrical

    accidents

    Basic points to be observed

  • 8/12/2019 HAZ of Elec

    4/27

    FACTORS GOVERNING

    ELECTRICAL HAZARDS

    1. Amplitude & duration of current

    2. Condition & position of the body

    3. Ambient temperature & humidity

    4. Oxygen & CO2 content in air

    5. Flooring condition

    6. Condition of EARTHING

    7. Sex & age of the person

  • 8/12/2019 HAZ of Elec

    5/27

    HEARTis the best pump designed by nature

    ..in the average life span of 70 years, pumps two

    million liter of blood, by beating 2500 million times!

    ......can not withstand 150 mille Amp current for more

    than one second. It can cause death. Controlled

    shock is used to revive heart.

    .....if fresh blood is not supplied to brain for

    more than THREE minutes, death can occur.

    .... of human beats @ 68 to 70 times / minute

    of elephant beats 25 times / min

    of mouse beats 700 times / min

    of parakeet beats 1000 times/ min

  • 8/12/2019 HAZ of Elec

    6/27

    EFFECT OF CURRENT

    ON HUMAN BODY50 Hz A..C. passing thro body for 1 second, through

    the route - left hand to both feet to earth.

    upto 1 mA No sensation

    1 mA to 8 mA Sensationbut not painful8 mA to 15 mA Painful shock

    15 mA to 20 mA Muscular control lost

    20 mA to 50 mA Severe muscular contraction

    50 mA to 200 mA Ventricular fibrillation

    possible death

    Above 200 mA Severe burnsSevere

    Ventr.fibrillation.- Heart arrest

  • 8/12/2019 HAZ of Elec

    7/27

  • 8/12/2019 HAZ of Elec

    8/27

    Condition Positionof the body

    Dry skin offers 100,000 to 600,000

    ohms resistance

    Wet skin offers only 1000 ohms resistance

    There are various postures of body, during which

    a person gets electric shock. The most dangerous

    position is the one, in which current passes

    through the heart in very short time / route.

  • 8/12/2019 HAZ of Elec

    9/27

    HEART CURRENT FACTOR

    CURRENT PATH HCF

    L. H. To left ft or right ft or both feet 1.0

    Both hands to both feet 1.0

    L. H. to R. H. 0.4

    R. H. to left ft or right ft or both feet 0.8

    Back to right hand 0.3

    Back to left hand 0.7 Chest to right hand 1.3

    Chest to left hand 1.5

    Seat to L. H. or R. H. or both hands 0.7

  • 8/12/2019 HAZ of Elec

    10/27

    How to f ind ou t TVF ?

    1. Threshold of Ventricular Fibrillation (TVF)

    is different for different current routes

    through the body.

    2. TVF for any route = TVF for LH to both feet

    HCF for that route ( ref. Table)

    3. For the route of current from chest to left hand

    TVF = 50 mA / 1.5 = 33 mA

    This means that, when 33 mA current passes forone second from chest to left hand, ventricular

    fibrillation is possible. For LH to both feet, this

    value is 50 mA.

  • 8/12/2019 HAZ of Elec

    11/27

    AMB IENT TEMPERATURE

    Higher More Wet Low

    Ambient Perspiration body resistance

    HUMIDITY

    Higher Body does not Low resistance

    Humidity get dried up

    CO2 & O2 CONTENT IN AIR

    Higher CO2 & lower O2 in the air, reduces

    the resistance of the body.

  • 8/12/2019 HAZ of Elec

    12/27

    CONDITION OF FLOORING

    1. Wet floor offers less than 100 ohms resistance

    2. Insulated rubber mat offers more

    than 10 million ohms resistance.

    3. Dry, varnished wood was used

    as support insulators in LT panels.

    4. Wet wood can give path to

    leakage current

    5. Accidents in bath rooms are fatal , because

    person with wet body is standing on the

    wet flooring.

  • 8/12/2019 HAZ of Elec

    13/27

    CONDITION OF EARTHING

    For earthing the equipment, there are many links

    from equipment to the EARTH.

    These are, Earth terminal ( of the equipment to beearthed ), Earth wire, Earth pin (in the plug ), Earthing

    from the switchboard to Distribution Board, Earthing

    wire from DB to the main Meter Box, from MB to

    Earth pipe ( inserted in the earth )

    Any weak link or discontinuity in the entire CHAIN,

    will create unsafe conditions during Electrical

    Accident

  • 8/12/2019 HAZ of Elec

    14/27

    CLASSIFICATIONOF

    ELECTRICAL ACCIDENTS42 % # Abuse of equipments # Poor maintenance.

    # Failure to switch off eqnt.(auto or manual)

    31 % # Inadequate design & assembly # Unreliable

    protection # Less clearance of live part from

    the body # Too much critical design

    27 % # Improper / unsafe workplace

    # Inadequate / confusing instructions

  • 8/12/2019 HAZ of Elec

    15/27

    PORTABLE TOOLS

    Check the condition of plug & socket

    Do not use the tool, if casing is broken

    Check the earthing connections at both ends

    Cord should be sufficiently long, to reach

    the workplace without tension .

    No temporary joints

    Never stand on damp surface whileoperating the portable tool.

    Do check the tool at ground level before use.

    Carry out preventive maintenance regularly.

  • 8/12/2019 HAZ of Elec

    16/27

    OH & UG Distr ibu t ion

    Accidental charging of the line / equipment

    Accidental back feeding of power

    Crane / Tower ladder crossing OH line

    Junction poles in the OH line network.Wrong identification of cables.

    Charging the line without total checking

    Wrong isolation of the circuit

    Not using safety appliancesLack of Preventive Maintenance

    Poor EARTHING

    Corrosion of OH poles at the base.

  • 8/12/2019 HAZ of Elec

    17/27

    DOMESTIC USE OF ELECTRICITY-1

    1. Do not let children play with electricity.

    2. Maintain EARTHING healthy. Check it regularly.

    3. Use 3-pin plug with earthing connected at both

    ends.

    4. Use fuse / MCB / switches of proper rating.

    5. Temporary repairs are dangerous.

    6. Give common knowledge of electricity to all

    family members.

  • 8/12/2019 HAZ of Elec

    18/27

    DOMESTIC USE OF

    ELECTRICITY-27. Do not repair electrical equipment without proper

    tools & knowledge.

    8. Do not carry out repair without isolating the

    circuit / equipment

    9. Never connect EARTHING with water pipe

    10. Multiple tapping from one socket are unsafe

    11 Be careful while washing floors & kitchen dado

    12. Never operate electrical appliances with wet hands

  • 8/12/2019 HAZ of Elec

    19/27

    OFFICES & SHOPS

    1. Wiring in the false ceiling

    2. Switches at visible location

    3. Positive isolation

    4. Chokes of fluorescent tube lamps

    5. High wattage lamps in the show case

    6. Reliable earthing for the power system

    7. Appliances like hot plate, elect, kettle etc.

    8. Fire Protection & Smoke Detection systems

    9. CO2 / Halon fire extinguishers at strategic

    locations

  • 8/12/2019 HAZ of Elec

    20/27

    MAJOR FACTORSCAUSING ELECTRICAL ACCIDENTS-1

    1. SHORT CUTS

    2. POOR EARTHING

    3. OVERCONFIDENCE4. HURRY TO COMPLETE THE JOB

    5. NOT USING SAFETY APPLIANCES

    6. WORKING WITHOUT CONCENTRATION

    7. LACK OF PREVENTIVE MAINTENANCE

    8. POOR KNOWLEDGE OF EQUIPMENTS

    & SYSTEM

  • 8/12/2019 HAZ of Elec

    21/27

    MAJOR FACTORSCAUSING ELECTRICAL

    ACCIDENTS- 2

    9. POOR QUALITY OF TOOLS

    10. UNSAFE WORKPLACE

    11 MISCOMMUNICATION

    12. TEMPORARY REPAIRS

    13. UNTRAINED MANPOWER

    14. IMPROPER / INADEQUATE PROTECTION

    15. NOT FOLLOWING THE SAFETY PROCEDURE

  • 8/12/2019 HAZ of Elec

    22/27

    BASIC POINTS TO BE OBSERVED

    Do not operate electrical equipments with wethands.

    . Use of wet shoes & wet clothing is unsafe

    Never connect earthing with water pipe

    Maintain EARTHING in good condition.

    Do not use water in electrical fires.

    Use personal protective appliances

    Temporary repairs are dangerous

    Qualified / Trained personnel

    Use ELCB.

    No monkey tricks, please....

  • 8/12/2019 HAZ of Elec

    23/27

    CASE STUDIES - 1

    Fatal accident to fitter

    When 5100 KW motor did not trip.....

    Fatal accident on 5 Amp socket

    Flash over during ACB checking

    Accidental start of 800 KW compressor motor

    Accident during maintenance on 11 KV panel

    Fatal accident due to cable TV wire.Street light ladder crossing 11 KV line

  • 8/12/2019 HAZ of Elec

    24/27

    CASE STUDIES - 2

    Shock on a fridge

    Accident during motor module maintenance

    Fatal accident to painterAccident to lineman

    Flash over during checking of lighting module

    Accident while using voltmeterC. T. replacement in MCC module

    Repairing table lamp in live condition

  • 8/12/2019 HAZ of Elec

    25/27

    CASE STUDIES - 3

    Switching on OH main line.

    Accident on the junction pole

    Three phase switch of AC plant

    Accident caused by back feeding of power

    Fire in the power transformer of theatre

    Earthing of bus side of OCB panel (SEC)

    Taking towel hanged on flexible wire

  • 8/12/2019 HAZ of Elec

    26/27

    CASE STUDIES - 4

    Cutting of wrong cable

    Non-standard termination of two cables in

    one straight joint

    Local heating in HT panel (after maint.)

    Flashover in 33 KV panel (BBP)

    Wireman taking measurement with cotton tape

    Opening of rear cover of HT panel...

    Man replacing lamp without switching it off

  • 8/12/2019 HAZ of Elec

    27/27

    Remember....Electricity is the best servant,

    BUT,

    Tough taskmaster.

    It does not tolerate any negligence,Penalties are heavy.

    HENCE,

    Treat Electricity respectfully.

    Thank you