Upload
joao-gilberto-fernandes
View
203
Download
20
Embed Size (px)
DESCRIPTION
1830 PSS 32 1660SM
Citation preview
Office Data Manual (ODM)
1660SM#02
1830 PSS-32#01Part:
Part: 2 04
2 051660SM#04
Part: 2 02
Project: PO#14 Domietta
Part:
1660SM#03
2 01
1660SM#02
Site name: Ezbet Elborg
Customer Name:
Part: 2 03
Telecom Egypt
Ezbet Elborg
0
Telecom Egypt
SITE ADRESS:
1830 PSS-32 # 01
Initial Document
SITE NAME:
0
Office Data Manual (ODM)
Customer No:
Customer Name:
SAP Network ID:
Equipment Number : 01
Version 2.0
Document Purpose
Final Document Verification Date N/A
Document Engineer
Document Helpdesk Telephone Number
Technical Support Helpdesk Telephone Number
Technical Support Helpdesk Mail Address
SAP Network ID
AllView Number
For Installation instructions see : See Floor Layout
Installation Guide Version Name
Installation Guide Release Issue
Date
Work Description
Alcatel-Lucent Document Control
Document Author
Name
Signed
Checked by Approved by
Name Name
Signed Signed
Post Installation As Built Verification
Alcatel-Lucent Representative Customer Representative
Name Name
Date Date
Signed Signed
Ezbet Elborg
Document Information Sheet 1830 PSS-32 # 01
Part 2 01 page 1 of 29 Version 2.0
Alcatel-Lucent - Proprietary
Use pursuant to company Instructions - All Rights ReservedRx.x_Vx A4
29-06-2015
6.0
Telecom Egypt
Installation of 1830PSS-32#01 shelf in new rack.
BASE: DASH:
8DG61259AAAAJZZA
Telecom Egypt
PO#14 Domietta
Ezbet Elborg
Alcatel-Lucent Document Number
Egypt
1830 PSS-32
Initial Document
Wojciech Mroczek
N/A
Wojciech Mroczek
DOCUMENT CHANGE HISTORY
I - Initial ODM # - New
F - Final ODM * - Removed
& - Transferred (moved)
% - Changed
Ezbet Elborg 0 Telecom Egypt
Survey of Changes 1830 PSS-32 # 01
Part 2 01 page 2 of 29 Version 2.0
Alcatel-Lucent - Proprietary
Use pursuant to company Instructions - All Rights ReservedA4
Date
1.0 I Installation of 1830PSS-32#01 shelf in new rack. Wojciech Mroczek 12-06-2015
29-06-2015
29-06-2015
Version Status Reason for Change / Re Issue Engineer
2.0 I Update ODM. Wojciech Mroczek
Part Number Description Page
2 1 1
2 1 2
2 1 3
2 1 4
2 1 5
2 1 6
2 1 7
2 1 8
2 1 9
2 1 10
2 1 11
2 1 12
2 1 13
2 1 14
2 1 15
2 1 16
2 1 17
2 1 18
2 1 19
2 1 20
2 1 21
2 1 22
2 1 23
2 1 24
2 1 25
2 1 26
2 1 27
2 1 28
2 1 29
Ezbet Elborg 0 Telecom Egypt
Index 1830 PSS-32 # 01
Part 2 01 page 3 of 29 Version 2.0
Alcatel-Lucent - Proprietary
Use pursuant to company Instructions - All Rights ReservedA4
Material Specification Hardware
Document Information Sheet
Survey of Changes
Index
Site Materials Specification
Front View Rack Layout
29-06-2015
XFP Modules for shelf 1830PSS-32#01
Optical amplifiers LINE connections 1830PSS-32#01 to LINE ODF
Front View 1830 PSS-32#01
SFP Modules for shelf 1830PSS-32#01
Tributary cards internal connections
44-channel static filter DWDM connections
Optical amplifiers cross conn.
Optical amplifiers DCM connections
44-channel static filter DWDM connections
44-channel static filter DWDM connections
44-channel static filter DWDM connections
44-channel static filter DWDM connections
Internal Connections
11G client signals 1830PSS-32#01 do ODF
44-channel static filter DWDM connections
Inventory connections
Cable List Power Supply
Cable List Grounding
11DPM12 client signals to ODF
11DPM12 client signals to ODF
Appendix C1 - HK and Rack alarm
Appendix A - Floor Plan layout
Appendix B - ODF layout
H
Check off
8DG09121AA** ETSI ONE RACK WITHOUT TRU/DOOR
1AF17443AAAA 1830 PDU-ETSI
8DG60224AAAA OPTIONAL PDU SLIDER KIT FOR ETSI
1AC043850003 CABLE 2 PAIR SHIELDED - ETSI
1AD151930001 FIBER STORAGE TRAY (2U)
8DG59604AC** KIT-CO SHELF INSTALLATION ETSI
8DG60129AA** CO SHELF ETSI COVER KIT
1AB017500078 BREAKER, 63A
8DG59605AB** MAIN SHELF KIT-PSS32, HIGH CAPACITY FAN
8DG59242BB** DC POWER FILTER (50A) W/ V MONITORING
8DG60207AAAA ESWL-1830 PSS WAVELENGTH TRACKER SOFTWARE LICENSE FEE
8DG62322AAAA SWP 1830PSS R6.0.6 4/16G EC DVD NO GMPLS
8DG62440AAAA SWPL 1830PSS R6.0.6 4/16G EC NO GMPLS
8DG59241AD** EQUIPMENT CONTROLLER (16GB)
8DG60227AAAA ACI-1830PSS DIR.SHIP.STANDARD
3AL89583AAAA CA-CRAFT CABLE (3M), (ETSI) ,HAL-FREE
8DG62440AAAA SWPL 1830PSS R6.0.6 4/16G EC NO GMPLS
8DG59418AA** FULL SLOT BLANK
8DG59613AA** KIT-TOOL KIT
8DG59724AA** FOADM INVENTORY CABLE ADAPTER
8DG60131AC** DCM COVER KIT (ETSI)
8DG59417AB** KIT-DCM SHELF (ANSI/ETSI)
8DG59603AA** KIT-OMD INSTALLATION KIT
8DG60130AC** OMD COVER KIT (ETSI)
3AL75117AAAA ESWL-PHOTONICS VERS "A" WDM LP
8DG59248AA** 44 CHANNEL OPTICAL MUX/DEMUX
3AL75117AAAA ESWL-PHOTONICS VERS "A" WDM LP
8DG60349AA** 11G QUAD PORT PLUGGABLE ANYRATE (4 CLIENT)
3AL75118AAAA ESWL-PHOTONICS VERS "A" TDM LP
8DG59828AA** 11G DPORT PLUGGABLE MULTIRATE MUX (12UC)
1AB375380013 ALU XFP I-64.1/10GBE BASE-L
1AB215120078 SIMPLEX JUMPER (3.5M) - ETSI
1AB375650046 ALU XFP DWDM TUNABLE CT
1AB215120075 SHORT JUMPER (230MM) - VOA APPLICATION
1AB215120076 SHORT JUMPER (155MM) - VOA APPLICATION
1AB373110001 OE-TRX SFP CWDM PIN CH51 B_SFP*MULTIRATE STM-1/16
1AB373120001 OE-TRX SFP CWDM APD CH51 B_SFP*MULTIRATE STM-1/16
1AB396080001 FAST EVOA SFP
1AB376720002 ALU SFP GBE LX/LX10 -40/+85
1AB215120078 SIMPLEX JUMPER (3.5M) - ETSI
3AL75117AAAA ESWL-PHOTONICS VERS "A" WDM LP
8DG59945AA** HIGH POWER LOW GAIN DWDM AMPLIFIER
8DG59423AA** DCM - SMF 10KM
Ezbet Elborg 0 Telecom Egypt
Material Specification Hardware 1830 PSS-32 # 01
Part 2 01 page 4 of 29 Version 2.0
Alcatel-Lucent - Proprietary
Use pursuant to company Instructions - All Rights ReservedA4
40
4
2
12
1
2
12
12
6
2
1
12
1
1
2
1
1
2
2
2
4
2
80
16
2
6
1
40
Ordercode Comcode
16
1
2
1
Description Qty
1
2
29-06-2015
Note : The Installer shall use this sheet to check that all materials have been delivered
1
1
1
1
1
1
1
4
I
Check off
Rack accessories
300507449 INSULATING TAPE 19.1MM X 4.572MR BLACK VELCRO
Power cables 25mm2 /1660SM/
1AC029050004 CABLE POWER PVC BLACK 2X25MM2
1AC000570022 HEAT SHRINKABLE TUBE 2:1 12.7MM RED
1AC000570029 HEAT SHRINKABLE TUBE 2:1 12.7MM CLEAR
1AC000570039 HEAT SHRINKABLE TUBE 2:1 12.7MM BLUE
1AC000570009 HEAT SHRINKABLE TUBE 2:1 12.7MM BLACK
GND cable 25mm2 /1660SM/
1AC053180011 CABLE POWER LS0H GREEN/YELLOW 25MM2
1AB032050044 LUG: TUBULAR TULIP B8-S16-22
GND cable 16mm2 /internal grounding; 1662SMC/
1AC053180008 CABLE POWER LS0H GREEN/YELLOW 16MM2
Inventory cable
1AC020430001 CABLE: SF/UTP, TE3 2x2x0.4MM SOLID HH2/M, GREY LS0H 4.65x3MM
Alarm cables 1830PSS-32
1AC013280001 CABLE: SF/UTP SYMMETRICAL PAIR (4QUAD, 2PAIRR/QUAD), 4x(2+2)x0.5MM SOLID, GREY PVC 0.8MM, 120OHM (1MHZ)
HK cables 1830PSS-32/VDS 1662SMC
3AL17957HLAA DF CORD 16P HF HE5-25MC 25 M
TB for E1, HK, VDS, alarm TRU
1AD021330001 2 X1/2 COVER-ACCESSORY FOR COMPAX+ LABEL
1AC014270015 MOUNTING STRIP, 89713
ODF
3CT01050AAAA SET OF 2 SC/PC OPTICAL ADAPTOR
Fibers for internal connections 1830PSS32to PSS-32 or PSS-36/64
1AB347840002 OPTO CABLE ASSEMBLY SX 2.0 SM LC/PC-LC/PC 1.5M LSZH-Y INDOOR
1AB347840003 OPTO CABLE ASSEMBLY SX 2.0 SM LC/PC-LC/PC 2.5M LSZH-Y INDOOR
Fibers to internal or LINE ODF
1AB350260005 OPTO CABLE ASSEMBLY SX 2.0 SM LC/PC-FC/PC 10M LSZH-Y INDOOR
Fibers to internal or LINE ODF
1AB346850008 OPTO CABLE ASSEMBLY SX 2.0 SM SC/PC-LC/PC 10M Y INDOOR
Protection pipe
1AC044110001 CABLE PIPING ROUND TUBE 17MM
Cables for IP phone
1AB229830003 CABLE ASSEMBLY CAT6E S/FTP 4x2x0.4 LSZH WHITE RJ-45-RJ-45 2M
Installation kit
1AD041540001 SET SCREW - INSTALLATION OF STATION /S9
ODF 36FO +rack
1AD082730006 OPTICAL PATCHING MODULE 1U - 36 ADAPTORS
1AD082730004 STORAGE OPTICAL MODULE 1U - 36 PATCHCORDS OR JUMPERS , LEFT OR RIGHT OPENING, 10080280
1AD029930001 CABINET 600X2200X300MM [WxHxD] 21IN 47U WITHOUT DOOR
Power cables 35mm2
1AC029050003 CABLE POWER PVC BLACK 2X35MM2
1AD056350001 DSL 35MM2 POWERING KIT
1AC053180014 CABLE POWER LS0H GREEN/YELLOW 35MM2
SC-FC fiber
1AB423400001 OPTO CABLE ASSEMBLY SX 2.0 SM SC/UPC-FC/UPC 10 MR G657A2 LSZH-Y INDOOR
IP PHONE
3GV27064UB Alcatel-Lucent IP Touch 4008 phone extended edition Urban Grey
CABLE POWER LS0H GREY FG7(0)M1 2X2.5MM2
PMV2-6RB-C Metric ring terminal with vinyl insulation
FSF80-12-7 Insullated ferules - single wire French end sleeve
Vinyl Butt splice - blue
Vinyl Butt splice - red
Fixed Shelf/tray for ETSI rack deep /<250mm +fixing accessories (screw, cage nuts, washers)/
1AB017500057 BREAKER, 1A
Ezbet Elborg 0 Telecom Egypt
Site Materials Specification 1830 PSS-32 # 01
Part 2 01 page 5 of 29 Version 2.0
Alcatel-Lucent - Proprietary
Use pursuant to company Instructions - All Rights ReservedA4
4
4
1
25
6
1
20
1
22
10
11
3
1
1
4
6
29-06-2015
Note : The Installer shall use this sheet to check that all materials have been delivered
1
1
1
1
2
3
1
1
1
Ordercode QtyComcode Description
2
1
6
40
44
2
2
1
Row Bay
01 PDU
02 1830PSS-32#01 (L1, L2)
L1: slot 2-3, dir. Ras Elbar
L2: slot 4-5, dir. Domietta1
03 SFD44 #01 L1: dir. Ras Elbar
04 SFD44 #02 L2: dir. Domietta1
05 Fiber Storage Tray
06 DCM shelf
L2: slot 1 dir. Domietta1
07 IP PHONE
L3: dir. Banha
ETSI ONE RACK 2200x600x300 [HxWxD]
Ezbet Elborg 0 Telecom Egypt
Front View Rack Layout 1830 PSS-32 # 01
Part 2 01 page 6 of 29 Version 2.0
Alcatel-Lucent - Proprietary
Use pursuant to company Instructions - All Rights ReservedA4
Front View Rack Layout
29-06-2015
A 3
IP PHONE
DMSMF010 (1)
Row Bay
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18
19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36
0
2
2
2
2
1
1
2
2
1
1
1
1
2
2
#N/A
#N/A
0
0
#N/A
#N/A
#N/A
#N/A
1
1
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
0
0
#N/A
#N/A0
Ezbet Elborg 0 Telecom Egypt
Front View 1830 PSS-32#01 1830 PSS-32 # 01
Part 2 01 page 7 of 29 Version 2.0
Alcatel-Lucent - Proprietary
Use pursuant to company Instructions - All Rights ReservedA4
Part no. (Comcode)
40 USRPNL SSY-USER PANEL 8DG59240AAAA
39 Blank #N/A #N/A
38 Blank #N/A #N/A
37 FAN32H High Output PSS-32 Fan Tray 8DG59243ABAA
35 Blank #N/A #N/A
36 PFDC (50A) SSY-POWER FILTER, 50A BREAKER 8DG59242BBAA
Blank #N/A #N/A
34 Blank #N/A #N/A
33
11D
PM
12
11Q
PA
4
FAN32H
USRPNL
AH
PLG
AH
PLG
AH
PLG
11D
PM
12
Full
Slo
t B
lank
Full
Slo
t B
lank
Full
Slo
t B
lank
Full
Slo
t B
lank
Full
Slo
t B
lank
Full
Slo
t B
lank
4
1
Bla
nk
Bla
nk
AHPLG
POS. Short Description Card Description
EC
AHPLG
5
6
Equipment Controller (16GB)
HIGH POWER LOW GAIN DWDM AMPLIFIER
HIGH POWER LOW GAIN DWDM AMPLIFIER
HIGH POWER LOW GAIN DWDM AMPLIFIER
HIGH POWER LOW GAIN DWDM AMPLIFIER
Full Slot Blank
2
3
AHPLG
Full Slot Blank
Full Slot Blank
Full Slot Blank
8DG59418AA**
Full Slot Blank 8DG59418AA**
8DG59418AA**
23
11
8
9 Full Slot Blank
Full Slot Blank
11G Dual Port Pluggable Multirate Mux (12 universal clients)
11G Dual Port Pluggable Multirate Mux (12 universal clients)
16
Full Slot Blank
AHPLG
Full Slot Blank
27
28
17
18
20
21
22
13
12
14
10
Full Slot Blank
Full Slot Blank
Full Slot Blank
11DPM12
Full Slot Blank
Full Slot Blank
Front View 1830 PSS-32#01
7
15
8DG59418AA**
8DG59241ADAA
8DG59945AA
8DG59945AA
A 3
8DG59418AA**
8DG59945AA
8DG59945AA
AH
PLG
Full
Slo
t B
lank
8DG59828AA
11G QUAD PORT PLUGGABLE ANYRATE (4 CLIENT) 8DG60349AA**
Full
Slo
t B
lank
11Q
PA
4
EC
29-06-2015
Equipment Controller (16GB)
#N/A
#N/A
8DG59241ADAA
SSY-POWER FILTER, 50A BREAKER
#N/A
8DG59242BBAA
#N/A
EC
8DG59418AA**
8DG59418AA**
11QPA4 11G QUAD PORT PLUGGABLE ANYRATE (4 CLIENT) 8DG60349AA**
11DPM12
11QPA4
8DG59828AA
8DG59828AA
PFDC (50A)
#N/A
Blank #N/A #N/A
#N/A #N/A
Blank
Blank
Blank #N/A #N/A
Half Slot Blank 8DG59419AA**
Half Slot Blank 8DG59419AA**
Half Slot Blank
Blank
#N/A
Blank #N/A #N/A
#N/A #N/ABlank
Blank #N/A
24
25
26
29
#N/A
Blank #N/A #N/A
#N/A #N/A
30
31
32
EC
Half Slot Blank
Blank
Full Slot Blank
Blank
Full Slot Blank
19
PF
DC
(50A
)
Bla
nk
Bla
nk
Bla
nk
Bla
nk
Hal
f Sl
ot
Bla
nk
Half S
lot B
lank
Bla
nk
Bla
nk
PF
DC
(50A
)
Bla
nk
Bla
nk
Bla
nk
Bla
nk
Bla
nk
Bla
nk
Ezbet Elborg 0 Telecom Egypt
SFP Modules for shelf 1830PSS-32#01 1830 PSS-32 # 01
Part 2 01 page 8 of 29 Version 2.0
Alcatel-Lucent - Proprietary
Use pursuant to company Instructions - All Rights ReservedA4
02 14 VA1 EVOA SFP eVOA SFP 1AB396080001
02 15 C2 SFP GBE LX -40/+85 SFP GBE LX -40/+85 (Black and White 1 GbE DDM 1310 nm [1000BASE-LX]) 1AB376720002
02 15 C1 SFP GBE LX -40/+85 SFP GBE LX -40/+85 (Black and White 1 GbE DDM 1310 nm [1000BASE-LX]) 1AB376720002
02 15 VA1 EVOA SFP eVOA SFP 1AB396080001
02 16 VA2 EVOA SFP eVOA SFP 1AB396080001
02 16 VA1 EVOA SFP eVOA SFP 1AB396080001
02 17 VA2 EVOA SFP eVOA SFP 1AB396080001
02 17 VA1 EVOA SFP eVOA SFP 1AB396080001
02 14 C2 SFP GBE LX -40/+85 SFP GBE LX -40/+85 (Black and White 1 GbE DDM 1310 nm [1000BASE-LX]) 1AB376720002
02 14 C1 SFP GBE LX -40/+85 SFP GBE LX -40/+85 (Black and White 1 GbE DDM 1310 nm [1000BASE-LX]) 1AB376720002
SFP GBE LX -40/+85 SFP GBE LX -40/+85 (Black and White 1 GbE DDM 1310 nm [1000BASE-LX]) 1AB376720002
02 15 C8 SFP GBE LX -40/+85 SFP GBE LX -40/+85 (Black and White 1 GbE DDM 1310 nm [1000BASE-LX]) 1AB376720002
Shelf
02
SFP Modules for shelf 1830PSS-32#01
02
2
4 SS-16.2O
Internal
Part no. (Comcode)SFP DescriptionSlotSFP
POS.
SFP GBE LX -40/+85 SFP GBE LX -40/+85 (Black and White 1 GbE DDM 1310 nm [1000BASE-LX])
SFP GBE LX -40/+85
SFP GBE LX -40/+85
29-06-2015
15 C3
SFP
Short Desc.
Internal
SFP GBE LX -40/+8502
SS-16.2O
02
1AB376720002
1AB376720002
OC3/STM1 PIN SFP (1510nm) with DDM
OC3/STM1 PIN SFP (1510nm) with DDM
1AB373110001
1AB373110001
SFP GBE LX -40/+85 (Black and White 1 GbE DDM 1310 nm [1000BASE-LX])
15 C4
SFP GBE LX -40/+85 SFP GBE LX -40/+85 (Black and White 1 GbE DDM 1310 nm [1000BASE-LX]) 1AB376720002
02 15 C5 SFP GBE LX -40/+85 SFP GBE LX -40/+85 (Black and White 1 GbE DDM 1310 nm [1000BASE-LX]) 1AB376720002
14 C5
02 14
02 15 C6
02 15 C7
SFP GBE LX -40/+85 (Black and White 1 GbE DDM 1310 nm [1000BASE-LX]) 1AB376720002
02 14 C4 SFP GBE LX -40/+85 (Black and White 1 GbE DDM 1310 nm [1000BASE-LX]) 1AB376720002
02 14 C3
SFP GBE LX -40/+85 (Black and White 1 GbE DDM 1310 nm [1000BASE-LX]) 1AB376720002
02 14 C6 SFP GBE LX -40/+85 (Black and White 1 GbE DDM 1310 nm [1000BASE-LX]) 1AB376720002
SFP GBE LX -40/+85
SFP GBE LX -40/+85
02
C7 SFP GBE LX -40/+85 (Black and White 1 GbE DDM 1310 nm [1000BASE-LX]) 1AB376720002
02 14 C8 SFP GBE LX -40/+85 (Black and White 1 GbE DDM 1310 nm [1000BASE-LX]) 1AB376720002
SFP GBE LX -40/+85
SFP GBE LX -40/+85
Ezbet Elborg 0 Telecom Egypt
XFP Modules for shelf 1830PSS-32#01 1830 PSS-32 # 01
Part 2 01 page 9 of 29 Version 2.0
Alcatel-Lucent - Proprietary
Use pursuant to company Instructions - All Rights ReservedA4
02 15 C2 XI-64.1 ALU XFP I-64.1/10GBE BASE-L 1AB375380013
02 15 L2 XL-64TU ALU XFP DWDM TUNABLE CT 1AB375650046
02 17 C4 XI-64.1 ALU XFP I-64.1/10GBE BASE-L 1AB375380013
02 17 L4 XL-64TU ALU XFP DWDM TUNABLE CT 1AB375650046
02 17 C3 XI-64.1 ALU XFP I-64.1/10GBE BASE-L 1AB375380013
02 17 L3 XL-64TU ALU XFP DWDM TUNABLE CT 1AB375650046
02 14 C2 XI-64.1 ALU XFP I-64.1/10GBE BASE-L 1AB375380013
02 14 L2 XL-64TU ALU XFP DWDM TUNABLE CT 1AB375650046
02 14 L1 XL-64TU ALU XFP DWDM TUNABLE CT 1AB375650046
02 15 L1 XL-64TU ALU XFP DWDM TUNABLE CT 1AB375650046
02 15 C1 XI-64.1 ALU XFP I-64.1/10GBE BASE-L 1AB375380013
02 15 L1 XL-64TU ALU XFP DWDM TUNABLE CT 1AB375650046
02 16 C2 XI-64.1 ALU XFP I-64.1/10GBE BASE-L 1AB375380013
02 16 L2 XL-64TU ALU XFP DWDM TUNABLE CT 1AB375650046
02 16 C1 XI-64.1 ALU XFP I-64.1/10GBE BASE-L 1AB375380013
02 16 L1 XL-64TU ALU XFP DWDM TUNABLE CT 1AB375650046
XFP
Short Desc.
XFP Modules for shelf 1830PSS-32#01
Shelf Part no. (Comcode)
29-06-2015
XFP DescriptionSlotXFP
POS.
1AB375650046ALU XFP DWDM TUNABLE CTXL-64TUL21702
1AB375380013ALU XFP I-64.1/10GBE BASE-LXI-64.1C11702
02 17 C2 XI-64.1 ALU XFP I-64.1/10GBE BASE-L 1AB375380013
02 17 L1 XL-64TU ALU XFP DWDM TUNABLE CT 1AB375650046
02 17 L3 XL-64TU ALU XFP DWDM TUNABLE CT 1AB375650046
02 17 C1 XI-64.1 ALU XFP I-64.1/10GBE BASE-L 1AB375380013
02 17 C2 XI-64.1 ALU XFP I-64.1/10GBE BASE-L 1AB375380013
02 17 C3 XI-64.1 ALU XFP I-64.1/10GBE BASE-L 1AB375380013
20
1
A4
LINE ODF A 1 … Domietta1
Shelf Direction
1 … Ras ElbarFront
FrontLINE ODF A
The following connections are to be made using cable type:
Side
…
Name Row Bay
Front … LINE ODF_A/1/…/Ras Elbar/Front/…< >TE LINE ODF_B/1/…/Front/……
Conn. Length [m] Shelf
1830PSS-32#01_A/3/02/Domietta1/4/LINE IN< >LINE ODF_A/1/…/Front/…
Optical amplifiers LINE connections LINE ODF to TE LINE ODF
… Front …… 10 TE LINE ODF B 1
JARRETIERE OPTIQUE SM SC/FCS 10M/20
LINE ODF To: TE LINE ODF
1830PSS-32#01_A/3/02/Domietta1/4/LINE OUT< >LINE ODF_A/1/…/Front/…02
LINE OUT 10
Front … LINE ODF_A/1/…/Ras Elbar/Front/…< >TE LINE ODF_B/1/…/Front/…
LINE ODF_A/1/…/Domietta1/Front/…< >TE LINE ODF_B/1/…/Front/…
… LINE ODF_A/1/…/Domietta1/Front/…< >TE LINE ODF_B/1/…/Front/… … Front
… 10 TE LINE ODF B 1
… 10 TE LINE ODF B 1
Label
… 10 TE LINE ODF B 1
Tray Conn.
1
… Front …
… Front …1
1 1830PSS-32#01_A/3/02/Ras Elbar/2/LINE IN< >LINE ODF_A/1/…/Front/…
1830PSS-32#01_A/3/02/Ras Elbar/2/LINE OUT< >LINE ODF_A/1/…/Front/…
…
… Front …
LINE ODF A
A
LINE ODF
10 LINE ODF A
10
A
The following connections are to be made using cable type:
Optical amplifiers LINE connections 1830PSS-32#01 to LINE ODF
Name
OPTICAL JUMPER SM LC/FCS 10M/20
Length [m]
To: LINE ODF
RowBay
29
-06
-20
15
1830PSS-32#01
pa
ge
18
30
PS
S-3
2 #
01
Ve
rsio
n2
.0
Te
lec
om
Eg
yp
t
Attention: Use the same label for both fibre ends
Use
pu
rsu
an
t to c
om
pa
ny In
stru
ctio
ns - A
ll Rig
hts
Re
se
rve
d
Alc
ate
l-Lu
ce
nt - P
rop
rieta
ry
x
Pa
rt
Ezb
et E
lbo
rg0
Op
tica
l am
plifie
rs L
INE
co
nn
ec
tion
s 1
83
0P
SS
-32
#0
1 to
LIN
E O
DF
10
of 2
9
From:
A
Row
3
Bay Conn.
…
SideShelf
Front
Label
1830PSS-32#01
Shelf Port NameDirection Slot
A
02
Domietta1
Ras Elbar
1
10
LINE IN
LINE ODF
LINE IN
LINE OUT2
4
Front
Front
3
From:
Name Row Bay
1830PSS-32#01
20
1
A4
AM2125B
AM2318A
EMPTY
AM2125B
AM2318A
AM2125B
AM2125B
5
EMPTY
15
14
15
14
EMPTY
15
14
15
AHPLG
AHPLG
AHPLG
AM2125B
AHPLG
3
4
12
11
2
EAST2
EAST2
EAST1
EAST1
AM2125B
AM2125B
SIG IN
SIG OUT3
1830PSS-32#01_A/3/02/AHPLG/2/SIG IN< >1830PSS-32#01_A/3/02/AHPLG/3/SIG OUT
1830PSS-32#01_A/3/02/AHPLG//SIG OUT< >1830PSS-32#01_A/3/02/AHPLG/3/SIG INSIG IN3,5
3,51830PSS-32#01 A
1830PSS-32#01
Shelf Port NameCard Slot
02
Bay/Shelf Port
SIG OUT
SlotCard Label
AHPLG
Pa
rt
Ezb
et E
lbo
rg0
Op
tica
l am
plifie
rs c
ros
s c
on
n.
11
of 2
9
From:
A
Row
Use
pu
rsu
an
t to c
om
pa
ny In
stru
ctio
ns - A
ll Rig
hts
Re
se
rve
d
Alc
ate
l-Lu
ce
nt - P
rop
rieta
ry
x
1830PSS-32#01 A
1830PSS-32#01
29
-06
-20
15
1830PSS-32#01
pa
ge
18
30
PS
S-3
2 #
01
Ve
rsio
n2
.0
Te
lec
om
Eg
yp
t
Attention: Use the same label for both fibre ends
The following connections are to be made using cable type:
Optical amplifiers cross conn.
Name
DUPLEX JUMPER (3.5M), JARRETIERE OPTIQUE SM LC/LC 2.5M/20
Length [m]
To: 1830PSS-32#01
RowBay
1830PSS-32#01_A/3/02/AHPLG/3/LINE IN< >1830PSS-32#01_A/3/03/SFD44#01/25/1/OMD OUT
LINE OUT 3,5 OMD IN
OMD OUTLINE IN 3,5
1830PSS-32#01_A/3/02/AHPLG/3/LINE OUT< >1830PSS-32#01_A/3/03/SFD44#01/25/1/OMD IN
51830PSS-32#01 A 3/02SIG IN 3,5 SIG OUT 1830PSS-32#01_A/3/02/AHPLG/4/SIG IN< >1830PSS-32#01_A/3/02/AHPLG/5/SIG OUT
AHPLG
LINE IN 3,5 OMD OUT 1830PSS-32#01_A/3/02/AHPLG/5/LINE IN< >1830PSS-32#01_A/3/04/SFD44#02/26/1/OMD OUT
26/1
SIG OUT 3,5 SIG IN 1830PSS-32#01_A/3/02/AHPLG/4/SIG OUT< >1830PSS-32#01_A/3/02/AHPLG/5/SIG IN
LINE OUT 3,5 OMD IN 1830PSS-32#01_A/3/02/AM2318A/11/LINE OUT< >1830PSS-32#01_A/3/04/SFD44#02/26/1/OMD IN1830PSS-32#01 A 3/04 SFD44#02
131830PSS-32#01 A 3/04LINE OUT 3,5 SIG IN 1830PSS-32#01_A/3/02/AM2125B/12/LINE OUT< >1830PSS-32#01_A/3/04/CWR8B/13/SIG IN
CWR8B
LINE IN 3,5 SIG OUT 1830PSS-32#01_A/3/02/AM2318A/11/LINE IN< >1830PSS-32#01_A/3/04/CWR8B/13/SIG OUT13
1830PSS-32#01_A/3/02/AM2125B/12/< >1830PSS-32#01_A/3/04/CWR8B/13/
1830PSS-32#01_A/3/02/AM2318A/11/< >1830PSS-32#01_A/3/04/CWR8B/13/1830PSS-32#01 A 3/04 CWR8B
161830PSS-32#01 A 1 / 02LINE IN 1,5 SIG OUT 1830PSS-32#01_A/1/02/AM2125B/15/LINE IN< >1830PSS-32#01_A/1 / 02/WR8-88A/16/SIG OUT
WR8-88A
MON 3,5 IN2 1830PSS-32#01_A/1/02/AM2318A/14/MON< >1830PSS-32#01_A/1 / 02/WTOCM/2/IN22
1830PSS-32#01_A/1/02/AM2125B/15/< >1830PSS-32#01_A/1 / 02/WR8-88A/16/
1830PSS-32#01_A/1/02/AM2318A/14/< >1830PSS-32#01_A/1 / 02/WTOCM/2/1830PSS-32#01 A 1 / 02 WTOCM
21830PSS-32#01 A 1 / 02MON 3,5 IN1 1830PSS-32#01_A/1/02/AM2125B/15/MON< >1830PSS-32#01_A/1 / 02/WTOCM/2/IN1
WTOCM
LINE OUT 1,5 SIG IN 1830PSS-32#01_A/1/02/AM2125B/14/LINE OUT< >1830PSS-32#01_A/1 / 02/WR8-88AF/16/SIG IN16
1830PSS-32#01_A/1/02/AM2125B/15/< >1830PSS-32#01_A/1 / 02/WTOCM/2/
1830PSS-32#01_A/1/02/AM2125B/14/< >1830PSS-32#01_A/1 / 02/WR8-88AF/16/1830PSS-32#01 A 1 / 02 WR8-88AF
161830PSS-32#01 A 1 / 02LINE IN 1,5 SIG OUT 1830PSS-32#01_A/1/02/AM2125B/15/LINE IN< >1830PSS-32#01_A/1 / 02/WR8-88AF/16/SIG OUT
WR8-88AF
MON 3,5 IN2 1830PSS-32#01_A/1/02/AM2125B/14/MON< >1830PSS-32#01_A/1 / 02/WTOCM/24/IN224
1830PSS-32#01_A/1/02/AM2125B/15/< >1830PSS-32#01_A/1 / 02/WR8-88AF/16/
1830PSS-32#01_A/1/02/AM2125B/14/< >1830PSS-32#01_A/1 / 02/WTOCM/24/1830PSS-32#01 A 1 / 02 WTOCM
241830PSS-32#01 A 1 / 02MON 3,5 IN1 1830PSS-32#01_A/1/02/AM2125B/15/MON< >1830PSS-32#01_A/1 / 02/WTOCM/24/IN1
WTOCM
Line RX skip
1830PSS-32#01_A/1/02/AM2125B/15/< >1830PSS-32#01_A/1 / 02/WTOCM/24/
Line TX skip1830PSS-32#01
Line RX skip
Line RX
Line TX skip1830PSS-32#01
skip1830PSS-32#01
3 02
skip
Line TX
A 3 02
1830PSS-32#01 A 3 02
1830PSS-32#01 A 3 02
1830PSS-32#01 A 3 02
1830PSS-32#01 A 1 02
1830PSS-32#01 A 1 02
1830PSS-32#01 A 1 02
1830PSS-32#01 A 1 02
1830PSS-32#01 A 1 02
1830PSS-32#01 A 1 02
1830PSS-32#01 A 1 02
1830PSS-32#01 A 3 ZZ
1830PSS-32#01 A 3 ZZ
1830PSS-32#01 A 3 ZZ
1830PSS-32#011830PSS-32#01 A 3 ZZ EMPTYskip
Line TX
Line RX
1830PSS-32#01 A 3 ZZLine RX
EMPTYEAST1Line TX
1830PSS-32#01
skip
skip
skip
3
1830PSS-32#01 A 3/03 SFD44#01 25/1
3/02
20
1
A4
XX16 YY16
XX15 YY15
XX11 YY11
XX13
XX14 YY14
YY13
XX9 YY9
XX12 YY12
XX8 YY8
XX10 YY10
… 1 02 Slot 15
XX7 YY7
A 3 06 27/1
02 2B 02 Slot 10
AHPLG A 3 02 3
A 3 02 4
AHPLG
AHPLG
DMSMF010
AHPLG
A2325A
EMPTY
Card Slot
EMPTY
EMPTY
EMPTY
EMPTY
EMPTY
EMPTY
EMPTY
EMPTY
EAST1
2
3
4
5
EMPTY
EMPTY
EMPTY
EMPTY
EMPTY
AHPLG
AHPLG
AHPLG
AHPLG
AHPHG
A2325A
EAST1
EAST1
EAST2
EAST2
WEST1
EAST2
EAST2
EAST2
EAST2
EAST2
WEST1
31830PSS-32#01_A/3/02/AHPLG/2/DCM IN< >AHPLG_A/3/02/2/DCM OUT
1830PSS-32#01_A/3/02/AHPLG/2/< >AHPLG_A/3/02/2/
0,155A02 02 2
1830PSS-32#01
Shelf Port Name
DCM IN
To:
Bay Conn.
DCM OUT
SlotShelf Label
3
Pa
rt
Ezb
et E
lbo
rg0
Op
tica
l am
plifie
rs D
CM
co
nn
ec
tion
s
12
of 2
9
From:
A
Row
2.0
Te
lec
om
Eg
yp
t
Attention: Use the same label for both fibre ends
Use
pu
rsu
an
t to c
om
pa
ny In
stru
ctio
ns - A
ll Rig
hts
Re
se
rve
d
Alc
ate
l-Lu
ce
nt - P
rop
rieta
ry
x
DCM modules, OA
RowBay
29
-06
-20
15
1830PSS-32#01
pa
ge
18
30
PS
S-3
2 #
01
Ve
rsio
n
DCM IN 0,155 DCM OUT 1830PSS-32#01_A/3/02/AHPLG/3/DCM IN< >AHPLG_A/3/02/3/DCM OUT
The following connections are to be made using cable type:
Optical amplifiers DCM connections
Name
SIMPLEX JUMPER (3.5M)
Length [m]
1830PSS-32#01
DCM IN 0,155 DCM OUT 1830PSS-32#01_A/3/02/AHPLG/4/DCM IN< >AHPLG_A/3/02/4/DCM OUT
1830PSS-32#01_A/3/02/AHPLG/3/< >AHPLG_A/3/02/3/
DCM IN 3,5 OUT 1830PSS-32#01_A/3/02/AHPLG/5/DCM IN< >DMSMF010_A/3/06/27/1/OUT
1830PSS-32#01_A/3/02/AHPLG/4/< >AHPLG_A/3/02/4/
DCM IN 0,155 DCM OUT skip
DCM OUT 3,5 IN 1830PSS-32#01_A/3/02/AHPLG/5/DCM OUT< >DMSMF010_A/3/06/27/1/IN
DCM IN 0,155 DCM OUT skip
skip
DCM RX Tx skip
skip
DCM RX Tx skip
DCM TX Rx skip
DCM RX Tx skip
DCM TX Rx skip
DCM RX Tx skip
DCM TX Rx skip
DCM RX Tx skip
DCM TX Rx skip
DCM RX Tx skip
DCM TX Rx skip
DCM RX Tx skip
DCM TX Rx skip
DCM RX Tx skip
DCM TX Rx skip
DCM RX Tx skip
DCM TX Rx skip
DCM RX Tx skip
DCM TX Rx skip
A 3 02
DCM TX Rx skip3
1830PSS-32#01 A 3 02
1830PSS-32#01 A 3 02
1830PSS-32#01 A 3 02
1830PSS-32#01 A 3 02
1830PSS-32#01 A 3 ZZ
1830PSS-32#01 A 3 ZZ
1830PSS-32#01 A 3 ZZ
1830PSS-32#01 A 3 ZZ
1830PSS-32#01 A 3 ZZ
1830PSS-32#01 A 3 ZZ
ZZ
1830PSS-32#01 A 3 ZZ
1830PSS-32#01 A 3 ZZ
1830PSS-32#01 A 3 ZZ
1830PSS-32#01 A 3 ZZ
1830PSS-32#01 A
TxYY17
DCM RXXX17
1830PSS-32#01 A 3 ZZ
skip
DCM TX Rx skip
DCM RXYY18
DCM TXXX18
Rx
skip
skip
Tx
20
1
A4
11QPA4 EMPTY VA4 IN skipL4 OUT 0,23 1830 PSS-32#01 A 3 021830 PSS-32#01 A 3 02 11QPA4 EMPTY
02 11QPA4 EMPTY VA3 IN skipEMPTY L3 OUT 0,23 1830 PSS-32#01 A 3
11QPA4 EMPTY VA2 IN skip
1830 PSS-32#01 A 3 02 11QPA4
L2 OUT 0,23 1830 PSS-32#01 A 3 02
EMPTY VA1 IN skip
1830 PSS-32#01 A 3 02 11QPA4 EMPTY
0,155 1830 PSS-32#01 A 3 02 11QPA4
VA1 IN 1830 PSS-32#01/A/3/02/11DPM12/14/L1 OUT< >1830 PSS-32#01/A/3/11DPM12/14/VA1 IN
1830 PSS-32#01 A 3 02 11QPA4 EMPTY L1 OUT
1830 PSS-32#01 A 3 02 11DPM12 14
1830 PSS-32#01/A/3/02/11DPM12/15/L1 OUT< >1830 PSS-32#01/A/3/11DPM12/15/VA1 IN
1830 PSS-32#01 A 3 02 11DPM12 14 L1 OUT 0,23
A 3 02 11DPM12 15 VA1 IN02 11DPM12 15 L1 OUT 0,23 1830 PSS-32#01
1830 PSS-32#01/A/3/02/11QPA4/17/L2 OUT< >1830 PSS-32#01/A/3/11QPA4/17/VA2 IN11QPA4
Trib
uta
ry c
ard
s in
tern
al c
on
ne
ctio
ns
Ezb
et E
lbo
rg
From:
Uwaga: użyj jednakowych etykiet na obu końcach kabla
18
30
PS
S-3
2 #
01
1830 PSS-32#01 A
02
Te
lec
om
Eg
yp
t
17 VA2 IN
29
-06
-20
15
2.0
Ve
rsio
n
3
L2 OUT
0
pa
ge
13
of 2
9
0,23 1830 PSS-32#01 A 31830 PSS-32#01 A 3 02 11QPA4 17
02 11QPA4 17 VA1 IN 1830 PSS-32#01/A/3/02/11QPA4/17/L1 OUT< >1830 PSS-32#01/A/3/11QPA4/17/VA1 IN17 L1 OUT 0,155 1830 PSS-32#01 A 3
Slot Port Label
1830 PSS-32#01 A 3 02 11QPA4
Lenght [m] Name Row Bay Shelf Name
1830 PSS-32#01 To: 11QPA4,11DPM12
Name Row Bay Shelf Card Slot Port
x Use
pu
rsu
an
t to c
om
pa
ny In
stru
ctio
ns - A
ll Rig
hts
Re
se
rve
d
Alc
ate
l-Lu
ce
nt - P
rop
rieta
ry
Tributary cards internal connections
Cable type: SHORT JUMPER (155MM), SHORT JUMPER (230MM)
Pa
rt
1830 PSS-32#01 A 3 02 11QPA4 16 L1 OUT 0,155 1830 PSS-32#01 A 3 02 11QPA4 16 VA1 IN 1830 PSS-32#01/A/3/02/11QPA4/16/L1 OUT< >1830 PSS-32#01/A/3/11QPA4/16/VA1 IN
1830 PSS-32#01 A 3 02 11QPA4 16 L2 OUT 0,23 1830 PSS-32#01 A 3 02 11QPA4 16 VA2 IN 1830 PSS-32#01/A/3/02/11QPA4/16/L2 OUT< >1830 PSS-32#01/A/3/11QPA4/16/VA2 IN
20
1
A4
9290
9300
OUT
IN
OUT
9250
9260
9270
9280
9310
9320
IN
OUT
IN
OUT
IN
OUT
IN
OUT
9210
9220
9230
9240
9170
9180
9190
9200
9330
9340
9350
IN
OUT
IN
OUT
IN
OUT
IN
OUT
IN
OUT
IN
OUT
IN
OUT
IN
OUT
IN
OUT
OUT
IN
OUT
IN
IN
OUT
44
-ch
an
ne
l sta
tic filte
r DW
DM
co
nn
ec
tion
s
14
of 2
9
Bay Port
TX
SlotShelf
Ezb
et E
lbo
rg
Name
SFD44#01
03
0
IN
OUT
Shelf Port
IN
44-channel static filter DWDM connections
Attention: Use the same label for both fibre ends
29
-06
-20
15
skip
skip
From:
Pa
rt
Use
pu
rsu
an
t to c
om
pa
ny In
stru
ctio
ns - A
ll Rig
hts
Re
se
rve
d
Alc
ate
l-Lu
ce
nt - P
rop
rieta
ry
x
Row
pa
ge
18
30
PS
S-3
2 #
01
Ve
rsio
n2
.0
Te
lec
om
Eg
yp
t
Name
Length [m]
To:
Row Bay
The following connections are to be made using cable type:
Label
skip
EMPTY
EMPTY
skip
skipRX
TX skip
RX skip
TX
TX skip
RX skip
RX
EMPTY
skip
TX skip
TX skip
RX skip
RX
EMPTY
skip
TX skip
TX skip
RX skip
RX skipEMPTY
TX
EMPTY
EMPTY
RX
TX skip
TX skip
RX
skip
RX
EMPTY
skip
TX skip
TX skip
RX skip
RX
EMPTY
skip
TX skip
TX skip
RX skip
RX
EMPTY
skip
TX skip
TX skip
RX skip
RX
3
skip
3,5 OUTA
SFD44#01_A/3/03/9340/IN< >SFD44#02_A/3/04/9340/OUT
OUT SFD44#01_A/3/03/9350/IN< >SFD44#02_A/3/04/9350/OUT
3,5 INSFD44#02
SFD44#01_A/3/03/9340/OUT< >SFD44#02_A/3/04//IN04
SFD44#02
9340
SFD44#01 A 3
3,5 IN SFD44#01_A/3/03/9350/OUT< >SFD44#02_A/3/04/9350/IN
3,5
EMPTY
EMPTY
EMPTY
EMPTY
EMPTY
EMPTY
EMPTY
A 3 04 9350
20
1
A4
26/1
14
Shelf Port
9530IN
OUT
9540IN
OUT
9510IN
OUT
9520IN
OUT
9490IN
OUT
9500IN
OUT
9470IN
OUT
9480IN
OUT
9450IN
OUT
9460IN
OUT
9430IN
OUT
9440IN
OUT
9410IN
OUT
9420IN
OUT
IN
OUT
9390IN
OUT
9400IN
OUT
SFD44#01 A 3
TX skipEMPTY
RX skip
RX skip
TX skip
RX skip
TX skip
RX skip
TX skip
RX skip
TX skip
RX skip
TX skip
RX skip
TX skip
RX skip
TX skip
RX skip
TX skip
SFD44#01_A/3/03/9450/OUT< >_////
SFD44#01_A/3/03/9450/IN< >_////
3,5 L1 IN SFD44#01_A/3/03/9440/OUT< >11DPM12_A/3/02/14/L1 INA
3,5 VA1 OUT SFD44#01_A/3/03/9440/IN< >11DPM12_A/3/02/14/VA1 OUT02
3.5 9430 IN SFD44#01_A/3/03/9430/OUT< >SFD44#02_A/3/04/26/1/9430 IN
3.5 9430 OUT SFD44#01_A/3/03/9430/IN< >SFD44#02_A/3/04/26/1/9430 OUTSFD44#02 A
3,5 L2 IN SFD44#01_A/3/03/9420/OUT< >11QPA4_A/3/02//L2 INA
3,5 VA2 OUT SFD44#01_A/3/03/9420/IN< >11QPA4_A/3/02/16/VA2 OUT11QPA4
3.5 L1 IN SFD44#01_A/3/03/9410/OUT< >11QPA4_A/3/02/16/L1 IN
3.5 VA1 OUT SFD44#01_A/3/03/9410/IN< >11QPA4_A/3/02/16/VA1 OUT11QPA4 A
SFD44#01_A/3/03/9400/OUT< >_////
SFD44#01_A/3/03/9400/IN< >_////
SFD44#01_A/3/03/9390/OUT< >_////
SFD44#01_A/3/03/9390/IN< >_////
TX skip
EMPTY RX skip
skipEMPTY
TX skip
The following connections are to be made using cable type:
44-channel static filter DWDM connections
Name
SIMPLEX JUMPER (3.5M) - ETSI
Length [m]
To: various
Row Bay
From:
Row
pa
ge
18
30
PS
S-3
2 #
01
Ve
rsio
n2
.0
Te
lec
om
Eg
yp
t
Use
pu
rsu
an
t to c
om
pa
ny In
stru
ctio
ns - A
ll Rig
hts
Re
se
rve
d
Alc
ate
l-Lu
ce
nt - P
rop
rieta
ry
x
15
of 2
9
Attention: Use the same label for both fibre ends
29
-06
-20
15
RX
0
44
-ch
an
ne
l sta
tic filte
r DW
DM
co
nn
ec
tion
s
03
9360IN
OUT
9370IN
OUT
9380
Pa
rt
Ezb
et E
lbo
rg
Name
SFD44#01
Bay Port
TX
SlotShelf Label
skip
skipRXEMPTY
3 02 16
023 16
3 04
EMPTY
11DPM12 3
EMPTY
EMPTY
EMPTY
EMPTY
EMPTY
EMPTY
EMPTY
20
1
A4
Bay Port
TX
SlotShelf Label
skip
skip
A
IN
IN
OUT
IN
OUT
OUT
IN
OUT
Attention: Use the same label for both fibre ends
29
-06
-20
15
From:
Pa
rt
Ezb
et E
lbo
rg
Name
SFD44#01
Use
pu
rsu
an
t to c
om
pa
ny In
stru
ctio
ns - A
ll Rig
hts
Re
se
rve
d
Alc
ate
l-Lu
ce
nt - P
rop
rieta
ry
x
0
44
-ch
an
ne
l sta
tic filte
r DW
DM
co
nn
ec
tion
s
16
of 2
9
Port Row
pa
ge
18
30
PS
S-3
2 #
01
Ve
rsio
n2
.0
Te
lec
om
Eg
yp
t
3
44-channel static filter DWDM connections
Name
LC - Duplex SM - LC, LC - Simplex SM - LC
Length [m]
To:
Row Bay Shelf
skip
skipEMPTY
The following connections are to be made using cable type:
RX
IN
OUT
IN
OUT
skip
TX skip
RX
TX skip
TX skip
skip
RX skip
TX skip
RX
RX
skip
EMPTY
EMPTY
EMPTY
TX
EMPTY
EMPTY
RX
SFD44#01 03
9550
9560
9570
9580
9590
9600
20
1
A4
A 3 02 17
EMPTY
EMPTY
EMPTY
EMPTY
EMPTY
EMPTY
EMPTY
SFD44#02 A 3
used L3 IN SFD44#02_A/3/04/9350/OUT< >11QPA4_A/3/02/17/L3 IN
used VA3 OUT SFD44#02_A/3/04/9350/IN< >11QPA4_A/3/02/17/VA3 OUT
used L1 IN11QPA4
SFD44#02_A/3/04/9340/OUT< >11QPA4_A/3/02/17/L1 IN02 17
11QPA4
RX
3
skip
used VA1 OUTA
SFD44#02_A/3/04/9340/IN< >11QPA4_A/3/02/17/VA1 OUT
TX skip
RX skip
RX
EMPTY
skip
TX skip
TX skip
RX skip
RX
EMPTY
skip
TX skip
TX skip
RX skip
RX
EMPTY
skip
TX skip
TX skip
RX
skip
RX
TX skip
TX
EMPTY
EMPTY
RX skipEMPTY
TX skip
RX skip
RX
EMPTY
skip
TX skip
TX skip
RX skip
RX
EMPTY
skip
TX skip
TX skip
RX skip
TX skip
RX skip
TX skip
EMPTY
EMPTY
skip
skipRX
Length [m]
To:
Row Bay
The following connections are to be made using cable type:
Label
From:
Row
pa
ge
18
30
PS
S-3
2 #
01
Ve
rsio
n2
.0
Te
lec
om
Eg
yp
t
Name
Pa
rt
Use
pu
rsu
an
t to c
om
pa
ny In
stru
ctio
ns - A
ll Rig
hts
Re
se
rve
d
Alc
ate
l-Lu
ce
nt - P
rop
rieta
ry
x
Shelf Port
IN
44-channel static filter DWDM connections
Attention: Use the same label for both fibre ends
29
-06
-20
15
skip
skip
Bay Port
TX
SlotShelfName
44
-ch
an
ne
l sta
tic filte
r DW
DM
co
nn
ec
tion
s
17
of 2
9
Ezb
et E
lbo
rg
SFD44#02
04
0
IN
OUT
OUT
IN
9340
OUT
IN
IN
OUT
IN
IN
OUT
9350
OUT
IN
9330
IN
OUT
IN
OUT
IN
OUT
IN
OUT
IN
OUT
IN
OUT
IN
OUT
IN
9230
9240
OUT
OUT
9170
9180
9190
9200
9210
9220
OUT
9310
9320
IN
OUT
IN
OUT
IN
OUT
9250
9260
9270
9280
9290
9300
20
1
A4
26/1
15
EMPTY
3 04
EMPTY
EMPTY
EMPTY
EMPTY
EMPTY
EMPTY
11QPA4
EMPTY
11DPM12 02
023 17
3 02A 17
skipRXEMPTY
EMPTY TX skip
Bay Port
TX
SlotShelf Label
Pa
rt
Ezb
et E
lbo
rg
Name
SFD44#02
0
44
-ch
an
ne
l sta
tic filte
r DW
DM
co
nn
ec
tion
s
18
of 2
9
Attention: Use the same label for both fibre ends
29
-06
-20
15
Use
pu
rsu
an
t to c
om
pa
ny In
stru
ctio
ns - A
ll Rig
hts
Re
se
rve
d
Alc
ate
l-Lu
ce
nt - P
rop
rieta
ry
x
The following connections are to be made using cable type:
44-channel static filter DWDM connections
Row
pa
ge
18
30
PS
S-3
2 #
01
Ve
rsio
n2
.0
Te
lec
om
Eg
yp
t
Name
SIMPLEX JUMPER (3.5M) - ETSI
Length [m]
To: various
Row Bay
From:
RX skipEMPTY
TX skip
EMPTY RX skip
TX skip
RX skip
RX skip
TXEMPTY
3.5 L1 IN SFD44#02_A/3/04/9410/OUT< >11QPA4_A/3/02//L1 IN
3.5 VA1 OUT SFD44#02_A/3/04/9410/IN< >11QPA4_A/3/02/17/VA1 OUT
3,5 L2 IN SFD44#02_A/3/04/9420/OUT< >11QPA4_A/3/02//L2 INA
3,5 VA2 OUT SFD44#02_A/3/04/9420/IN< >11QPA4_A/3/02/17/VA2 OUT11QPA4
used 9430 IN SFD44#02_A/3/04/9430/OUT< >SFD44#02_A/3/04//9430 IN
used 9430 OUT SFD44#02_A/3/04/9430/IN< >SFD44#02_A/3/04/26/1/9430 OUTSFD44#02 A
3,5 L1 IN SFD44#02_A/3/04/9440/OUT< >11DPM12_A/3/02/15/L1 INA
3,5 VA1 OUT SFD44#02_A/3/04/9440/IN< >11DPM12_A/3/02/15/VA1 OUT3
used SFD44#02_A/3/04/9450/OUT< >_////
used SFD44#02_A/3/04/9450/IN< >_////
RX skip
TX skip
RX skip
TX skip
RX skip
TX skip
RX skip
TX skip
RX skip
TX skip
RX skip
TX skip
RX skip
TX skip
RX skip
TX skip
TX skipEMPTY
RX skip
SFD44#02 A 3
04
9360IN
OUT
9370IN
OUT
9380IN
OUT
9390IN
OUT
9400IN
OUT
9410IN
OUT
9420IN
OUT
9430IN
OUT
9440IN
OUT
9450IN
OUT
9460IN
OUT
9470IN
OUT
9480IN
OUT
9490IN
OUT
9500IN
OUT
9510IN
OUT
9520IN
OUT
9530IN
OUT
9540IN
OUT
Shelf Port
20
1
A4
OUT
IN
OUT
TX
EMPTY
EMPTY
EMPTY
IN
OUT
EMPTY
skip
RX
RX
skip
EMPTY skip
RX skip
TX skip
TX skip
RX skip
TX skip
RX skip
The following connections are to be made using cable type:
RX
IN
OUT
IN
OUT
3
TX
44-channel static filter DWDM connections
Name
LC - Duplex SM - LC, LC - Simplex SM - LC
Length [m]
To:
Row Bay Shelf Port Row
pa
ge
18
30
PS
S-3
2 #
01
Ve
rsio
n2
.0
Te
lec
om
Eg
yp
t
Use
pu
rsu
an
t to c
om
pa
ny In
stru
ctio
ns - A
ll Rig
hts
Re
se
rve
d
Alc
ate
l-Lu
ce
nt - P
rop
rieta
ry
x
19
of 2
9
Attention: Use the same label for both fibre ends
29
-06
-20
15
Pa
rt
skipEMPTY
44
-ch
an
ne
l sta
tic filte
r DW
DM
co
nn
ec
tion
s
From:
SFD44#02 04
9550
9560
9570
9580
9590
9600
Ezb
et E
lbo
rg
Name
SFD44#02
A
0
IN
IN
OUT
Bay Port
TX
SlotShelf Label
skip
skip
20
1
A4
27/1 INV1830PSS-32#01_A/3/02/A1/n.a./B OUT< >SFD44#02_A/3/04/27/1/INV
0B OUT 1,5 SFD44#02 A 3 041830PSS-32#01 A 3 02 A1 n.a.
27/1 INV1830PSS-32#01_A/3/02/A1/n.a./A OUT< >DMSMF010_A/3/06/27/1/INV
0A OUT 1,5 DMSMF010 A 3 061830PSS-32#01 A 3 02 A1 n.a.
302 AHPLG 2 INV INV03 25/1SFD44#01 A1,5
Shelf Card Slot Port Name Row
The following connections are to be made using cable type:
Inventory connections
Name
LAN cable with RJ11 connectors
Length [m]
To: DCM, SFD441830PSS-32#01
Row Bay
pa
ge
18
30
PS
S-3
2 #
01
Ve
rsio
n2
.0
Te
lec
om
Eg
yp
t
Attention: Use the same label for both fibre ends
29
-06
-20
15
Use
pu
rsu
an
t to c
om
pa
ny In
stru
ctio
ns - A
ll Rig
hts
Re
se
rve
d
Alc
ate
l-Lu
ce
nt - P
rop
rieta
ry
x
0
Inv
en
tory
co
nn
ec
tion
s
20
of 2
9
From:
Pa
rt
Ezb
et E
lbo
rg
31830PSS-32#01 A
1830PSS-32#01 A 3
Bay PortSlotShelf Label
1830PSS-32#01_A/3/02/AHPLG/2/INV< >SFD44#01_A/3/03/25/1/INV
0
1830PSS-32#01_A/3/02/AHPLG/5/INV< >DMSMF010_A/3/06/27/1/INV02 AHPLG 5 INV 1,5 DMSMF010
0
INV
A 3 06 27/1 INV
26/11830PSS-32#01 A 3 02 AHPLG 4 INV1830PSS-32#01_A/3/02/AHPLG/4/INV< >SFD44#02_A/3/04/26/1/INV
01,5 SFD44#02 A 3 04
26/1 INV1830PSS-32#01_A/3/02/A1/n.a./B OUT< >SFD44#02_A/3/04/26/1/INV
0B OUT 1,5 SFD44#02 A 3 041830PSS-32#01 A 3 02 A1 n.a.
1830PSS-32#01 A 3 02 A2 n.a. A OUT 1,5 DMSMF010 A 3 06 4 INV1830PSS-32#01_A/3/02/A2/n.a./A OUT< >DMSMF010_A/3/06/4/INV
0
1830PSS-32#01 A 3 02 A2 n.a. B OUT 1,5 SFD44#02 A 3 04 n.a. INV1830PSS-32#01_A/3/02/A2/n.a./B OUT< >SFD44#02_A/3/04/n.a./INV
0
x
Ezbet Elborg 0 Telecom Egypt
Internal Connections 1830 PSS-32 # 01
Part 2 01 page 21 of 29 Version 2.0
Alcatel-Lucent - Proprietary
Use pursuant to company Instructions - All Rights ReservedA4
Management connections
HK: 3AL17957HLAA; ALARMS: 1AC013280001 + DB15 (part of 8DG59719AA); PHONE: 1AB229830003 + RJ45
Name Row Bay Shelf Conn.
E1
29-06-2015
Attention: For detailed information see Installation Guide Version 8DG61259AAAAJZZA R6.0
Slot Conn. Name Row Bay Shelf Block
1830PSS-32#01 3ACRAFT
4002
HK
E2
VOIP IP PHONE A 3 07 RJ45
OAMP DCN/SWITCH … … … … …
…Existing DDF … … …
……
…
…ALARM Existing DDF …
RL
…
20
1
A4
skipOUT
skip
skip
4IN
skip
OUT
skip
3IN
OUT
skip
skip
2IN
skip
OUT1
IN
skip
1830PSS-32#01 A 3 02 EMPTY
skip
OUT
skip
4IN
OUT
skip
skip
3IN
skip
OUT
skip
2IN
skip
OUT
IN
1830PSS-32#01 A 3 02 EMPTY
1
1
2
3
4
Te
lec
om
Eg
yp
t
18
30
PS
S-3
2 #
01
Ve
rsio
n2
.02
9-0
6-2
01
5
Uwaga: użyj jednakowych etykiet na obu końcach kabla
A 5
16
OUT 10 ODF
8 1830PSS-32#01_A/3/02/16/IN< >ODF_A/5/01/Rear/8
01 Rear 7 1830PSS-32#01_A/3/02/16/OUT< >ODF_A/5/01/Rear/7
1830PSS-32#01_A/3/02/16/OUT< >ODF_A/5/01/Rear/7
IN 10 ODF A 5 01 Rear
1830PSS-32#01_A/3/02/16/IN< >ODF_A/5/01/Rear/8
OUT 10 ODF A 5 01 Rear 7
1830PSS-32#01_A/3/02/16/OUT< >ODF_A/5/01/Rear/7
22
of 2
9
IN 10 ODF A 01 Rear 8
1830PSS-32#01_A/3/02/16/IN< >ODF_A/5/01/Rear/8
OUT 10 ODF A 5 01 Rear 7
1830PSS-32#01_A/3/02/16/OUT< >ODF_A/5/01/Rear/5
IN 10 ODF A 5 01 Rear 8
1830PSS-32#01_A/3/02/16/IN< >ODF_A/5/01/Rear/6
pa
ge
OUT 10 ODF A 01 Rear 5
1830PSS-32#01_A/3/02/17/OUT< >0_0/0/0/0/
IN 10 ODF A 5 01 Rear 6
0 0
5
0 1830PSS-32#01_A/3/02/17/IN< >0_0/0/0/0/
0
OUT 0 0 0 0
0
5
1830PSS-32#01_A/3/02/17/OUT< >_///
IN 0 0 0 0
1830PSS-32#01_A/3/02/17/IN< >_///
OUT
01 Rear 3 1830PSS-32#01_A/3/02/17/OUT< >ODF_A/5/01/Rear/3
IN
01 Rear 4 1830PSS-32#01_A/3/02/17/IN< >ODF_A/5/01/Rear/4
OUT 10 ODF A
01 Rear 1 1830PSS-32#01_A/3/02/17/OUT< >ODF_A/5/01/Rear/1
IN 10 ODF A 5
01 Rear 2 1830PSS-32#01_A/3/02/17/IN< >ODF_A/5/01/Rear/2
OUT 10 ODF A 5
IN 10 ODF A 5
52
1830PSS-32#01 A 3 02 17
3
4
Bay Shelf Side Port EtykietaLenght [m] Name RowPort
11
G c
lien
t sig
na
ls 1
83
0P
SS
-32
#0
1 d
o O
DF
Ezb
et E
lbo
rg
From: 1830PSS-32#01 To:
1
x Use
pu
rsu
an
t to c
om
pa
ny In
stru
ctio
ns - A
ll Rig
hts
Re
se
rve
d
Alc
ate
l-Lu
ce
nt - P
rop
rieta
ry
Slot
1830PSS-32#01 A 3 02
11G client signals 1830PSS-32#01 do ODF
Typ kabla: OPTICAL JUMPER SM LC/SCS 10M/20
Pa
rt
ODF
Name Row Bay Shelf
20
1
A4
1 IN
3/11DPM12/Sh 02/Sl 15/LINE 2 OUT <=> ///LINE 2 OUT
2.0
29
-06
-20
15
Uwaga: użyj jednakowych etykiet na obu końcach kabla
9440
3/11DPM12/Sh 02/Sl 15/LINE 2 IN <=> ///
3/11DPM12/Sh 02/Sl 15/VA1 OUT <=> ///
LINE 2 IN
3/11DPM12/Sh 02/Sl 15/LINE1 IN <=> ///
Ve
rsio
n
VA1 OUT used
18
30
PS
S-3
2 #
01 3/11DPM12/Sh 02/Sl 15/12 OUT <=> ///
LINE1 IN used
3/11DPM12/Sh 02/Sl 15/12 IN <=> ///
12 OUT
3/11DPM12/Sh 02/Sl 15/11 OUT <=> ///
12 IN
3/11DPM12/Sh 02/Sl 15/11 IN <=> ///
11 OUT
02 3/11DPM12/Sh 02/Sl 15/10 OUT <=> ODF/02//
11 IN
02 3/11DPM12/Sh 02/Sl 15/10 IN <=> ODF/02//
10 OUT ODF A 5
10 IN ODF A 5
5 02 3/11DPM12/Sh 02/Sl 15/9 OUT <=> ODF/02//
3/11DPM12/Sh 02/Sl 15/9 IN <=> ODF/02//
Te
lec
om
Eg
yp
t
9 OUT ODF A
15 3/11DPM12/Sh 02/Sl 15/8 OUT <=> ODF/02/Rear/15
9 IN ODF A 5 02
16 3/11DPM12/Sh 02/Sl 15/8 IN <=> ODF/02/Rear/16
8 OUT 10 ODF A 5 02 Rear
13 3/11DPM12/Sh 02/Sl 15/7 OUT <=> ODF/02/Rear/13
8 IN 10 ODF A 5 02 Rear
14 3/11DPM12/Sh 02/Sl 15/7 IN <=> ODF/02/Rear/14
7 OUT 10 ODF A 5 02 Rear
11 3/11DPM12/Sh 02/Sl 15/6 OUT <=> ODF/02/Rear/11
23
of 2
9
7 IN 10 ODF A 02 Rear
12 3/11DPM12/Sh 02/Sl 15/6 IN <=> ODF/02/Rear/12
6 OUT 10 ODF A 5 02 Rear
9 3/11DPM12/Sh 02/Sl 15/5 OUT <=> ODF/02/Rear/9
pa
ge
6 IN 10 ODF A 02 Rear
10 3/11DPM12/Sh 02/Sl 15/5 IN <=> ODF/02/Rear/10
5 OUT 10 ODF A 5 02 Rear
7 3/11DPM12/Sh 02/Sl 15/4 OUT <=> ODF/02/Rear/7
5 IN 10 ODF A 5 02 Rear
8 3/11DPM12/Sh 02/Sl 15/4 IN <=> ODF/02/Rear/8
0
4 OUT 10 ODF A 02 Rear
5 3/11DPM12/Sh 02/Sl 15/3 OUT <=> ODF/02/Rear/5
4 IN 10 ODF A 5 02 Rear
6 3/11DPM12/Sh 02/Sl 15/3 IN <=> ODF/02/Rear/6
3 OUT 10 ODF A 5 02 Rear
3 3/11DPM12/Sh 02/Sl 15/2 OUT <=> ODF/02/Rear/3
3 IN 10 ODF A 5 02 Rear
4 3/11DPM12/Sh 02/Sl 15/2 IN <=> ODF/02/Rear/4
2 OUT 10 ODF A 02 Rear
1 3/11DPM12/Sh 02/Sl 15/1 OUT <=> ODF/02/Rear/1
2 IN 10 ODF A 5 02 Rear
1 OUT 10 ODF A 5 02
10 ODF A 5
5
5
1830 PSS-32 A 3 02 15
11
DP
M1
2 c
lien
t sig
na
ls to
OD
F
Ezb
et E
lbo
rg
From: 1830 PSS-32
Etykieta
5
5
02 Rear 2 3/11DPM12/Sh 02/Sl 15/1 IN <=> ODF/02/Rear/2
Rear
Name Row Bay Shelf Side Port
To: ODF
Name Row Bay Shelf Slot Wave Port Lenght [m]
x Use
pu
rsu
an
t to c
om
pa
ny In
stru
ctio
ns - A
ll Rig
hts
Re
se
rve
d
Alc
ate
l-Lu
ce
nt - P
rop
rieta
ry
11DPM12 client signals to ODF
The following connections are to be made using cable type: OPTICAL JUMPER SM LC/SCS 10M/20
Pa
rt
20
1
A4
1 IN
3/11DPM12/Sh 02/Sl 14/LINE 2 OUT <=> ///LINE 2 OUT
2.0
29
-06
-20
15
Uwaga: użyj jednakowych etykiet na obu końcach kabla
9440
3/11DPM12/Sh 02/Sl 14/LINE 2 IN <=> ///
3/11DPM12/Sh 02/Sl 14/VA1 OUT <=> ///
LINE 2 IN
3/11DPM12/Sh 02/Sl 14/LINE1 IN <=> ///
Ve
rsio
n
VA1 OUT used
18
30
PS
S-3
2 #
01 3/11DPM12/Sh 02/Sl 14/12 OUT <=> ///
LINE1 IN used
3/11DPM12/Sh 02/Sl 14/12 IN <=> ///
12 OUT
3/11DPM12/Sh 02/Sl 14/11 OUT <=> ///
12 IN
3/11DPM12/Sh 02/Sl 14/11 IN <=> ///
11 OUT
02 3/11DPM12/Sh 02/Sl 14/10 OUT <=> ODF/02//
11 IN
02 3/11DPM12/Sh 02/Sl 14/10 IN <=> ODF/02//
10 OUT ODF A 5
10 IN ODF A 5
5 02 3/11DPM12/Sh 02/Sl 14/9 OUT <=> ODF/02//
3/11DPM12/Sh 02/Sl 14/9 IN <=> ODF/02//
Te
lec
om
Eg
yp
t
9 OUT ODF A
31 3/11DPM12/Sh 02/Sl 14/8 OUT <=> ODF/02/Rear/31
9 IN ODF A 5 02
32 3/11DPM12/Sh 02/Sl 14/8 IN <=> ODF/02/Rear/32
8 OUT 10 ODF A 5 02 Rear
29 3/11DPM12/Sh 02/Sl 14/7 OUT <=> ODF/02/Rear/29
8 IN 10 ODF A 5 02 Rear
30 3/11DPM12/Sh 02/Sl 14/7 IN <=> ODF/02/Rear/30
7 OUT 10 ODF A 5 02 Rear
27 3/11DPM12/Sh 02/Sl 14/6 OUT <=> ODF/02/Rear/27
24
of 2
9
7 IN 10 ODF A 02 Rear
28 3/11DPM12/Sh 02/Sl 14/6 IN <=> ODF/02/Rear/28
6 OUT 10 ODF A 5 02 Rear
25 3/11DPM12/Sh 02/Sl 14/5 OUT <=> ODF/02/Rear/25
pa
ge
6 IN 10 ODF A 02 Rear
26 3/11DPM12/Sh 02/Sl 14/5 IN <=> ODF/02/Rear/26
5 OUT 10 ODF A 5 02 Rear
23 3/11DPM12/Sh 02/Sl 14/4 OUT <=> ODF/02/Rear/23
5 IN 10 ODF A 5 02 Rear
24 3/11DPM12/Sh 02/Sl 14/4 IN <=> ODF/02/Rear/24
0
4 OUT 10 ODF A 02 Rear
21 3/11DPM12/Sh 02/Sl 14/3 OUT <=> ODF/02/Rear/21
4 IN 10 ODF A 5 02 Rear
22 3/11DPM12/Sh 02/Sl 14/3 IN <=> ODF/02/Rear/22
3 OUT 10 ODF A 5 02 Rear
19 3/11DPM12/Sh 02/Sl 14/2 OUT <=> ODF/02/Rear/19
3 IN 10 ODF A 5 02 Rear
20 3/11DPM12/Sh 02/Sl 14/2 IN <=> ODF/02/Rear/20
2 OUT 10 ODF A 02 Rear
17 3/11DPM12/Sh 02/Sl 14/1 OUT <=> ODF/02/Rear/17
2 IN 10 ODF A 5 02 Rear
1 OUT 10 ODF A 5 02
10 ODF A 5
5
5
1830 PSS-32 A 3 02 14
11
DP
M1
2 c
lien
t sig
na
ls to
OD
F
Ezb
et E
lbo
rg
From: 1830 PSS-32
Etykieta
5
5
02 Rear 18 3/11DPM12/Sh 02/Sl 14/1 IN <=> ODF/02/Rear/18
Rear
Name Row Bay Shelf Side Port
To: ODF
Name Row Bay Shelf Slot Wave Port Lenght [m]
x Use
pu
rsu
an
t to c
om
pa
ny In
stru
ctio
ns - A
ll Rig
hts
Re
se
rve
d
Alc
ate
l-Lu
ce
nt - P
rop
rieta
ry
11DPM12 client signals to ODF
The following connections are to be made using cable type: OPTICAL JUMPER SM LC/SCS 10M/20
Pa
rt
x
…
…
…
…
PDU (Power Distribution Unit) with reference part nr. 1AF17443AAAA
Note: All infromation marked with "..." will be updated with As Built Document.
Ezbet Elborg 0 Telecom Egypt
Cable List Power Supply 1830 PSS-32 # 01
Part 2 01 page 25 of 29 Version 2.0
Alcatel-Lucent - Proprietary
Use pursuant to company Instructions - All Rights ReservedA4
A3/1A/-48V< >Input - Ve
A3/1A/RTN< >Input + Ve
GND< >GND
Input - Ve
Input + Ve
GND
3 07 n.a.
RED
BLUE
YE/GR
-48V
GND
3 2.5mm2 AA 3 A3/1A
RTN
BRTN DC BOX_…/…/ModB/RET< >PDU_A/3/BRTN
BLUE ARTN DC BOX_…/…/ModA/RET< >PDU_A/3/ARTN
3-48V_B DC BOX_…/…/ModB/…< >PDU_A/3/-48V_B
A 3
ABLUE
… … B60A
RET10m 70mm2
BLACK
-48V_A DC BOX_…/…/ModA/…< >PDU_A/3/-48V_A60A10m 70mm2
BLACK
RET
BLUE
BROWN
… … A
2,5
Row BayFuse/
sizeConn.
02
GND< >GND
+Bat2
BLACK
363 02
RED
AYE/GR
Slot
19
A1/63A/RTN< >+Bat1
A1/63A/-48V< >-Bat1
GND< >GND
B1/63A/RTN< >+Bat1
+Bat2
+Bat1
A 3 GNDA1/63A GND
-48V
10mm2
BLUE
-Bat1 B1/63A/-48V< >-Bat1
+Bat1
GND
...
BLUE
From: AC230V
-Bat1
A
DC BOX_…/DC BOX/ModB/RET< >PDU_A/3/BRTN
B1/63A/-48V< >-Bat2
N/A... ...... ... ... AC230V_.../.../Mod.../...< >AC Sockets_A/3/...3
Bay
Size
4mm2
Bay Conn.
To:
A1/63A/RTN< >+Bat2
A1/63A/-48V< >-Bat2
B1/63A/RTN< >+Bat2
-Bat2
DC BOXFrom:
…
…
Row
29-06-2015
Row
External AC power connections
Cable Type: Power Cable (See below for sizes)
PDU
External DC power connections
Cable Type: Power Cable (See below for sizes)
Label
AC Sockets
RowFuse/
size
DC BOX
RET
A
-48V_B
-48V_A
A 3DC BOX
10m
B…A
10m
…A
RETA
BRTNBROWN25mm2
DC BOX_…/DC BOX/ModB/…< >PDU_A/3/-48V_B
3
3
... AC230V_.../.../Mod.../...< >AC Sockets_A/3/...
DC BOX_…/DC BOX/ModA/…< >PDU_A/3/-48V_A
ARTN
Label
DC BOX_…/DC BOX/ModA/RET< >PDU_A/3/ARTN
Bay Mod
BayPower
Input
Power
Input
To:
Colour Row
Fuse/ Size
Length
1830PSS-32#01 / IP PHONE
Colour Row Bay
Internal DC power connections
-Bat2
2,5
BROWN
RTN
Shelf
Length
Length Size
Size Colour
BROWN
BLUE25mm2
Cable Type: Power Cable (See below for sizes)
From: PDU To:
10mm2
RED
-48V BLACK
3YE/GR
RTN
A
A 3
RTN
GND
-48V
-48V
RTN
B1/63A
Attention: For detailed information see Installation Guide Version 8DG61259AAAAJZZA 6.0
... 4mm2 N/A A... ... ... ...
x
Ezbet Elborg 0 Telecom Egypt
Cable List Grounding 1830 PSS-32 # 01
Part 2 01 page 26 of 29 Version 2.0
Alcatel-Lucent - Proprietary
Use pursuant to company Instructions - All Rights ReservedA4
29-06-2015
Label
RGRB_…/…/…< >BGRB_A/3/FRMGND
Label
Connector
Equipment
Name Input
FRMGND
1830PSS-32#02
03
Cabinet Grounding
Cable Type: VD CABLE 25mm2 YL/GN
From Room Ground Rail Bar To Bay Ground Rail Bar
N/A
Row Bay
… … …
Row BayConnector
A
Equipment Grounding
Cable Type: see below
From Bay Ground Rail Bar
Cable To equipment
Colour Type
YL/GR
16mm2YL/GR
GND
GND N/A
N/A
N/A
GND
GND
FRMGND
YL/GR 16mm2 1830PSS-32#01
YL/GR
Ezbet Elborg 0 Telecom Egypt
Appendix A - Floor Plan layout 1830 PSS-32 # 01
Part 2 01 page 27 of 29 Version 2.0
Alcatel-Lucent - Proprietary
Use pursuant to company Instructions - All Rights ReservedA4
29-06-2015
Storage Tray
01 ODF
Storage Tray
02 ODF
Storage Tray
03 ODF
Storage Tray
04 ODF
ODF RACK 2200x600x300 [HxWxD]
CABINET 600X2200X300MM [WxHxD] 21IN 47U WITHOUT DOOR
Ezbet Elborg 0 Telecom Egypt
Appendix B - ODF layout 1830 PSS-32 # 01
Part 2 01 page 28 of 29 Version 2.0
Alcatel-Lucent - Proprietary
Use pursuant to company Instructions - All Rights ReservedA4
29-06-2015
Storage Tray
Panel ODF
Storage Tray
Panel ODF
Storage Tray
Panel ODF
Panel ODF
Storage Tray
Ezbet Elborg 0 Telecom Egypt
Appendix C1 - HK and Rack alarm 1830 PSS-32 # 01
Part 2 01 page 29 of 29 Version 2.0
Alcatel-Lucent - Proprietary
Use pursuant to company Instructions - All Rights ReservedA4
29-06-2015
Office Data Manual (ODM)
Customer No:
Customer Name:
SAP Network ID:
0
Telecom Egypt
SITE ADRESS:
1660 SM #02
Initial Document
SITE NAME: Ezbet Elborg L2
Equipment Number : 02
Version 2.0
Document Purpose
Final Document Verification Date N/A
Document Engineer
Document Helpdesk Telephone Number
Technical Support Helpdesk Telephone Number
Technical Support Helpdesk Mail Address
SAP Network ID
AllView Number
For Installation instructions see : See Floor Layout
Technical Handbook Version Name
Technical Handbook Release Issue
Installation Handbook Version DateInstallation Handbook Release
Work Description
Alcatel-Lucent Document Control
Document Author
Name
Signed
Checked by Approved by
Name Name
Signed Signed
Post Installation As Built Verification
Alcatel-Lucent Representative Customer Representative
Name Name
Date Date
Signed Signed
Ezbet Elborg L2
Document Information Sheet 1660 SM # 02
Part 2 02 page 1 Version 2.0
Alcatel-Lucent - Proprietary
Use pursuant to company Instructions - All Rights ReservedR5.x_Va3 A4
8DG 15642 BAAA
5,5
8DG 15642 AAAA
BASE: DASH:
29-06-2015
N/A
Initial Document
Wojciech Mroczek
Alcatel-Lucent Document Number
1660 SM
Egypt
Telecom Egypt
PO#14 Domietta
Ezbet Elborg L2
5,5
Wojciech Mroczek
Installation of 1660SM#02 shelf in new rack.
DOCUMENT CHANGE HISTORY
I - Initial ODM # - New
F - Final ODM * - Removed
& - Transferred (moved)
% - Changed
Ezbet Elborg L2
Survey of Changes 1660 SM # 02
Part 2 02 page 2 Version 2.0
Alcatel-Lucent - Proprietary
Use pursuant to company Instructions - All Rights ReservedA4
Date
1.0 I Installation of 1660SM#02 shelf in new rack. Wojciech Mroczek 12-06-2015
29-06-2015
29-06-2015
Version Status Reason for Change / Re Issue Engineer
2.0 I Update ODM. Wojciech Mroczek
Part Number Description Page
2 2 1
2 2 2
2 2 3
2 2 4
2 2 5
2 2 6
2 2 7
2 2 8
2 2 9
2 2 10
2 2 11
2 2 12
2 2 13
2 2 14
2 2 15
2 2 16
2 2 17
2 2 18
2 2 19
2 2 20
2 2 21
2 2 22
2 2 23
Ezbet Elborg L2
Index 1660 SM # 02
Part 2 02 page 3 Version 2.0
Alcatel-Lucent - Proprietary
Use pursuant to company Instructions - All Rights ReservedA4
29-06-2015
Document Information Sheet
Survey of Changes
Index
System Diagram
Material Specification Hardware
Site Materials Specification
Front View Rack Layout
Front View Subrack Layout
Circuit pack placement
SFP and Modules
SFP and Modules
XFP and Modules
Cable List 48V DC Power Supply
Cable List Grounding
STM-64 connections 1660SM to ODF
1GbEth connections 1660SM to ODF
STM-1 connections 1660SM to ODF
External connections of 1660SM
Synchronization for 1660SM
External connections of 1660SM
Appendix D
Appendix E
Appendix F
Row Bay Shelf
Ezbet Elborg L2
System Diagram 1660 SM # 02
Part 2 02 page 4 Version 2.0
Alcatel-Lucent - Proprietary
Use pursuant to company Instructions - All Rights ReservedA4
SL
T2
3S
LT
40
MATRIXE
GETH-AGR
P16S1-4E
CO-64
Blank
ACCESS AREA
Blank
Blank
A12OS1SE
Blank
Blank
Blank
Blank
Blank
Blank
BASIC AREA
Front View Rack Layout
1660SM
29-06-2015
A 4 02
Blank
SL
T7
Blank
Blank
Blank
SL
T1
SL
T2
SL
T3
SL
T4
SL
T5
SL
T6
SL
T8
SL
T9
SL
T1
3S
LT
14
SL
T1
5S
LT
16
SL
T1
7S
LT
18
SL
T1
9S
LT
20
Blank
SL
T2
1
Blank
Blank
Blank
MATRIXE
Blank
CO-64
Blank
Blank
Blank
Blank
Blank
0
ISA-ES16
Blank
Blank
Blank
Blank
SL
T2
4S
LT
25
SL
T2
6S
LT
27
SL
T2
8S
LT
29
SL
T3
0S
LT
31
SL
T3
8S
LT
39
SL
T3
2S
LT
33
SL
T3
4S
LT
35
1660 SM
SL
T3
6S
LT
37
H
Check off
3AL35060AAXX ETSI ONE RACK WITH TRU
8DG09119AAAA DOOR ASSEMBLIES
3AL78817AA** SERVICES I/F
3AL78836AD** EQUICO E DCC ENH
3AL79266AA** CAPS ESD COM. PART OMSN
3AN49399AA** DUMMY PLATE W 30
3CA08540AA** 19"/21" ADAPTER KIT
3AN49400AA** DUMMY PLATE W 35
1AB162710015 CIRCUIT BREAKER 40A 72VCC
3AL81202AA** KIT T_BUS UPGRADE FOR ISA APPLIC
3AL81639AA** KIT-CABLING ETHERNET
3AL91653AAAA INST. KIT 1660SM SUBRACK WITH FANS
3AN50125AA** 120OHM KIT FOR CABLE SUPPORT
3AL89561AB** ASSEMBLED FANS UNIT
8DG15411AAAA ETSI TRAY WITH AIR DEFLECTOR FOR ASSEMBLED FAN UNIT
1AB162710005 CIRCUIT BREAKER 10A 72VDC
3AL89794AB** 1660SM SUBRACK WITH INTEGRATED FAN SHELF
8DG15611AA** MATRIX ENHANCED
8DG15663AMAA SWP-1660SM_SDH R.5.5 A8
8DG16038AMAA SWPL-1660SM_SDH R.5.5 A8
3AL78830AE** CONTROL AND GENERAL I/F (2 WIRES / 960W / 25A / WITH FAN SUPERVISION)
1AB147830012 256MB COMPACT FLASH CARD (-40/+85C)
3AL81922AAAA 1660SM DIRECT SHIPM.
1AB074610019 CONN.RJ45 M. 8 WIRES IDC CAT.6
3AN49397AA** DUMMY PLATE W 20
3AL89857AAAA SFP DUMMY PLUG KIT
8DG15701AA** PORT 16XSTM1 - 4XSTM4 DCC ENH
8DG15540ACAA ESWL-OMSN METRO VERS. "A" TDM LP
8DG15432AA** STM64 PORT XFP PLUGGABLE
8DG15540ACAA ESWL-OMSN METRO VERS. "A" TDM LP
3AL91880AA** OPTICAL ACCESS 12XSTM1 SLIM
1AB194670007 OPTO TRX SFP S-1.1 DDM -40/+85
3AL91721AAAA XFP-E ADAPTER
1AB214540001 XFP I-64.1/10GBE BASE L
1AF00398AAAA TELEPHONE HANDSET
8DG15235AA** 4XGE SFP ES-16 ACCESS
8DG15540ABAA ESWL-OMSN METRO VERS. "A" ETH LP
1AB187280031 OPTO TRX SFP 1GBE LX DDM
8DG16021ACAA SWPL-ES16B ENH R.2.4B1 PLUS
3AL81915BA** ISA-ES16 ENH SERIES
8DG15540ABAA ESWL-OMSN METRO VERS. "A" ETH LP
Ezbet Elborg L2
Material Specification Hardware 1660 SM # 02
Part 2 02 page 5 Version 2.0
Alcatel-Lucent - Proprietary
Use pursuant to company Instructions - All Rights ReservedA4
2
1
1
6
1
2
1
1
1
1
1
1
1
1
1
1
1
2
1
1
1
31
2
1
2
1
2
1
8
1
16
Ordercode Comcode Description Qty
29-06-2015
Note : The Installer shall use this sheet to check that all materials have been delivered
1
1
8
2
40
2
2
1
1
H
Check off
Rack accessories
300507449 TAPE VELCRO 19MM WIDE X L=5M
Power cables 16mm2 /1660SM/
1AC029050002 CABLE POWER PVC BLACK 2X16MM2
GND cable 16mm2 /1660SM/
1AC053180008 CABLE POWER LS0H GREEN/YELLOW 16MM2
1AB032050044 Lug - tubular tulip B8-S16-22
Alarm cables OPTINEX TRU to DDF
1AB200670003 CLER ALA HE5-9M 15 M
Internal cable for FAN-1660SM CONGI [HK+ALARM]
3AL18034CNAA CLEE 2 Q HF HE5-15MC/15M
HK 1660SM
3AL17956HLAA DF CORD 4Q HF HE5-15M-C 25 M
VDS 1660SM
1AB200480001 DF CORD 33P HF HE5-50M 25 M
SYNCHRONIZATION CABLE 120OHM
1AB200560001 CLER 4P HF 1.0/2.3 BAL 25 m
FUN DDF
1AB352380001 FUN2000AC FRAME-OPEN RACK DDF 10122264
TB for E1, HK, VDS, alarm TRU
1AD021330001 Half Cover for Compax IDC TB
1AC014270015 TB 8 pairs COMPAX 1D cable side
TB for E3/STM-1e
1AD033710001 COMPAX MODULE 8 COAX 1.5/5.6
E1 1660SM
1AB199770002 CLER 2X4 QUARTESHE5-37M 15M
Handset support
3AL17213AAAB Support Hand set - Kit to fixing
E3/STM-1e 1660SM
1AB002130002 Socket 1,6/5,6 Fem. coax straight - crimp.
1AB009720030 Plug - Coax 1,0/2,3 Push Pull - Straight
1AC000800009 4P COAX HCX4 391 313
3AN240200005 CLIPPEUR 1660SM STM-34 KIT
Fibers to internal or LINE ODF
1AB102910004 Optical jumper FCsSCs0DB15M/28
1AB346850008 OPTICAL JUMPER SM LC/SCS 10M/20
Protection pipe
1AC044110001 Sheath - (green) Ringed for 20 opt jump
Installation kit
1AD041540001 Installation of Station S9 - Set screw
ODF 36 ports
1AD082730006 PLATEAU 36 RACCORDS 1UD 19P/ETSI
1AD082730004 STORING TRAY 36 FO 1UR 19/ETSI
3CT01050AAAA Records - optical SCspc - Set of 2
Ezbet Elborg L2
Site Materials Specification 1660 SM # 02
Part 2 02 page 6 Version 2.0
Alcatel-Lucent - Proprietary
Use pursuant to company Instructions - All Rights ReservedA4
10
12
20
Ordercode Comcode Description Qty
1
1
1
1
1
1
1
7
7
1
30
46
Note : The Installer shall use this sheet to check that all materials have been delivered
29-06-2015
1
2
2
20
Row A Bay 4 Shelf 02
01 TRU
02 1660SM #02 L2
L1: slot 25, dir. Sawama Gharb
L2: slot 26, dir. Shatora
L3: slot 31, dir. N. Kady
03 FAN UNIT
05 FAN UNIT
Ezbet Elborg L2
Front View Rack Layout 1660 SM # 02
Part 2 02 page 7 Version 2.0
Alcatel-Lucent - Proprietary
Use pursuant to company Instructions - All Rights ReservedA4
Front View Rack Layout
1660SM
29-06-2015
ETSI ONE RACK WITH TRU 2200x600x300
TRU
MA
TR
YC
A A
EQ
UIC
O A
CO
NG
I A
SE
RV
ICE
22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21
Fan
Row Bay 02
System name:
1 2 3 4 5 6 7 8 9 10 12 13 14 15 16 17 18 19 20 21
22 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 41
Ezbet Elborg L2
Front View Subrack Layout 1660 SM # 02
Part 2 02 page 8 Version 2.0
Alcatel-Lucent - Proprietary
Use pursuant to company Instructions - All Rights ReservedA4
Bla
nk
CO
NG
I
MA
TR
IXE
Bla
nk
Shelf
Front View Subrack Layout
Bla
nk
Bla
nk
Bla
nk
Bla
nk
FANS
SE
RV
ICE
CO
NG
I
A 4
11
Bla
nk
1660SM
Bla
nk
Bla
nk
29-06-2015
Bla
nk
Bla
nk
A12O
S1S
E
Bla
nk
CO
-64
Bla
nk
Bla
nk
Bla
nk
MA
TR
IXE
PQ
2/E
QC
Bla
nk
23
Bla
nk
Bla
nk
GE
TH
-AG
R
P16S
1-4
E
CO
-64
0
Bla
nk
Bla
nk
Bla
nk
40
Bla
nk
Bla
nk
Bla
nk
ISA
-ES
16
Bla
nk
Bla
nk
Bla
nk
Row Bay Shelf 02
System name:
Ezbet Elborg L2
Circuit pack placement 1660 SM # 02
Part 2 02 page 9 Version 2.0
Alcatel-Lucent - Proprietary
Use pursuant to company Instructions - All Rights ReservedA4
31 Blank
32 Blank
t.b.d t.b.d
t.b.d t.b.d
t.b.d t.b.d
#N/A #N/A
3AL81915 BA-- t.b.d
t.b.d
t.b.d t.b.d
t.b.d t.b.d
29 Blank
30 Blank
27 Blank
28 Blank
t.b.d
t.b.d t.b.d
t.b.d t.b.d
t.b.d t.b.d
t.b.d t.b.d
t.b.d
26 Blank
24 Blank
25 CO-64
t.b.d
3AL78836AD-- t.b.d
21 Blank Blank t.b.d
22 PQ2/EQC EQUICO E DCC ENH
MATRIX ENHANCED23
t.b.d
MATRIXE 8DG15611AA--
18 Blank Blank t.b.d
19 Blank
20 Blank
t.b.dBlank
Blank
16 Blank Blank t.b.d
Blank
8DG 15235 AA-- t.b.d17 GETH-AGR
14 A12OS1SE OPTICAL ACCESS 12xSTM1 SLIM
15 Blank
t.b.d
3AL 91880 AA-- t.b.d
t.b.d t.b.d
CONTROL AND GENERAL INTERFACE
t.b.dBlank13 Blank
12 CONGI
3AL78830AE-- t.b.d
Blank
10 CONGI CONTROL AND GENERAL INTERFACE
Blank
9 Blank
8
t.b.d
Blank
6 Blank Blank
Blank
t.b.dSERVICES I/F11 SERVICE
Blank
7
t.b.d
Blank Blank
2 Blank Blank
3 Blank Blank
4 Blank
5 Blank Blank
Blank
8DG 15432 AA-- t.b.d
t.b.d
t.b.d t.b.d
t.b.d t.b.d
t.b.d
t.b.d
t.b.d t.b.d
8DG15701AA-- t.b.d
t.b.d
3AL78817AA--
t.b.d
t.b.dt.b.d
t.b.d
t.b.d t.b.d
3AL78830AE-- t.b.d
1660SM
A 4
t.b.d
Card Description
34 CO-64
33 P16S1-4E
1
35
36 ISA-ES16
37 Blank
39 Blank
38 Blank
40 MATRIXE
MATRIX ENHANCED
t.b.d t.b.d
8DG15611AA-- t.b.d
29-06-2015
Slot App. Code Part Number Clei Code
t.b.d
Blank
4xGE SFP ES-16 ACCESS CARD
t.b.d
t.b.d
8DG 15432 AA--
Blank
Blank
Blank
16xSTM1 - 4xSTM4 DCC ENH
STM64 PORT XFP PLUGGABLE
#N/A
t.b.d
CIRCUT PACKS PLACEMENT
ISA-ES16 BOARD
Blank
Blank
Blank
Blank
Blank
Blank
STM64 PORT XFP PLUGGABLE
Blank
Ezbet Elborg L2
SFP and Modules 1660 SM # 02
Part 2 02 page 10 Version 2.0
Alcatel-Lucent - Proprietary
Use pursuant to company Instructions - All Rights ReservedA4
t.b.d
OPTO TRX SFP S-1.1 DDM -40/+85 1AB 194670007 t.b.d
t.b.dSS-1.1 OPTO TRX SFP S-1.1 DDM -40/+85 1AB 194670007
OPTO TRX SFP S-1.1 DDM -40/+85 1AB 194670007
Comcode Clei Code
1AB 194670007
A12OS1SE
t.b.d
4
OPTO TRX SFP S-1.1 DDM -40/+85 1AB 194670007 t.b.d
3 SS-1.1
SS-1.1 OPTO TRX SFP S-1.1 DDM -40/+85
OPTO TRX SFP S-1.1 DDM -40/+85 1AB 194670007
t.b.d
t.b.d
t.b.d
t.b.d
t.b.d
9 SS-1.1 OPTO TRX SFP S-1.1 DDM -40/+85 1AB 194670007 t.b.d
8 SS-1.1 OPTO TRX SFP S-1.1 DDM -40/+85 1AB 194670007
7 SS-1.1 OPTO TRX SFP S-1.1 DDM -40/+85 1AB 194670007 t.b.d
6 SS-1.1 OPTO TRX SFP S-1.1 DDM -40/+85 1AB 194670007
5 SS-1.1 OPTO TRX SFP S-1.1 DDM -40/+85 1AB 194670007 t.b.d
4 SS-1.1 OPTO TRX SFP S-1.1 DDM -40/+85 1AB 194670007
3 SS-1.1 OPTO TRX SFP S-1.1 DDM -40/+85 1AB 194670007 t.b.d
OPTO TRX SFP S-1.1 DDM -40/+85 1AB 194670007
Mod.
Pos.
Module
App. CodeModule Description
1 SS-1.1 OPTO TRX SFP S-1.1 DDM -40/+85 1AB 194670007
Comcode Clei Code
2 SS-1.1
14
10 SS-1.1
12 SS-1.1
11
1AB 194670007 t.b.d
P16S1-4E
Card
Pos.
Card
Pos.
332 SS-1.1
29-06-2015
t.b.d
Mod.
Pos.
Module
App. CodeModule Description
1
SS-1.1 OPTO TRX SFP S-1.1 DDM -40/+85
4 SS-1.1 OPTO TRX SFP S-1.1 DDM -40/+85
t.b.d12 SS-1.1 OPTO TRX SFP S-1.1 DDM -40/+85 1AB 194670007
SS-1.1
Comcode Clei Code
OPTO TRX SFP S-1.1 DDM -40/+85
1AB 194670007 t.b.d
P16S1-4E
Card
Pos.
Mod.
Pos.
Module
App. CodeModule Description Comcode Clei Code
1AB 194670007 t.b.d
2 SS-1.1 OPTO TRX SFP S-1.1 DDM -40/+85 1AB 194670007 t.b.d
1 SS-1.1 OPTO TRX SFP S-1.1 DDM -40/+85
333 SS-1.1 OPTO TRX SFP S-1.1 DDM -40/+85 t.b.d
4 SS-1.1 OPTO TRX SFP S-1.1 DDM -40/+85 1AB 194670007 t.b.d
1 SS-1.1 OPTO TRX SFP S-1.1 DDM -40/+85
1AB 194670007
A12OS1SE
Card
Pos.
Mod.
Pos.
Module
App. CodeModule Description
3 SS-1.1
1AB 194670007 t.b.d
2 SS-1.1 OPTO TRX SFP S-1.1 DDM -40/+85 1AB 194670007 t.b.d
t.b.d
1AB 194670007
OPTO TRX SFP S-1.1 DDM -40/+85
1AB 194670007
1AB 194670007
OPTO TRX SFP S-1.1 DDM -40/+85 1AB 194670007
1AB 194670007
SS-1.1
t.b.d
8 SS-1.1 OPTO TRX SFP S-1.1 DDM -40/+85 1AB 194670007 t.b.d
SS-1.1 OPTO TRX SFP S-1.1 DDM -40/+85
5
14
1AB 194670007 t.b.d
6
t.b.d
9 SS-1.1 OPTO TRX SFP S-1.1 DDM -40/+85 1AB 194670007
SS-1.1 OPTO TRX SFP S-1.1 DDM -40/+85 t.b.d
7
11 SS-1.1 OPTO TRX SFP S-1.1 DDM -40/+85
t.b.d
t.b.d
10
Ezbet Elborg L2
SFP and Modules 1660 SM # 02
Part 2 02 page 11 Version 2.0
Alcatel-Lucent - Proprietary
Use pursuant to company Instructions - All Rights ReservedA4
29-06-2015
17
1 1GBE LX OPTO TRX SFP 1GBE LX DDM
3 1GBE LX OPTO TRX SFP 1GBE LX DDM 1AB187280031 t.b.d
4 1GBE LX OPTO TRX SFP 1GBE LX DDM 1AB187280031 t.b.d
Comcode Clei Code
1AB187280031 t.b.d
2 1GBE LX OPTO TRX SFP 1GBE LX DDM 1AB187280031 t.b.d
2 1GBE LX
t.b.d
t.b.d
GETH-AGR
Card
Pos.
Mod.
Pos.
Module
App. CodeModule Description
1AB187280031
t.b.d1AB187280031
OPTO TRX SFP 1GBE LX DDM17
1 1GBE LX OPTO TRX SFP 1GBE LX DDM 1AB187280031 t.b.d
4 1GBE LX OPTO TRX SFP 1GBE LX DDM 1AB187280031
3 1GBE LX OPTO TRX SFP 1GBE LX DDM
Ezbet Elborg L2
XFP and Modules 1660 SM # 02
Part 2 02 page 12 Version 2.0
Alcatel-Lucent - Proprietary
Use pursuant to company Instructions - All Rights ReservedA4
38 1 SS-16.1 OPTO TRX SFP S-16.1 DDM -5/+85 1AB 196370006 t.b.d
37 1 SS-16.1 OPTO TRX SFP S-16.1 DDM -5/+85 1AB 196370006 t.b.d
36 1 SS-16.1 OPTO TRX SFP S-16.1 DDM -5/+85 1AB 196370006 t.b.d
31 1 SS-16.1 OPTO TRX SFP S-16.1 DDM -5/+85 1AB 196370006 t.b.d
30 1 SS-16.1 OPTO TRX SFP S-16.1 DDM -5/+85 1AB 196370006 t.b.d
29 1 SS-16.1 OPTO TRX SFP S-16.1 DDM -5/+85 1AB 196370006 t.b.d
28 1 SS-16.1 OPTO TRX SFP S-16.1 DDM -5/+85 1AB 196370006 t.b.d
Module
App. CodeModule Description Comcode Clei Code
27 1 SS-16.1 OPTO TRX SFP S-16.1 DDM -5/+85 1AB 196370006 t.b.d
CO-64
Card
Pos.
Mod.
Pos.
Module
App. CodeModule Description Comcode Clei Code
1AB214540001 t.b.d
1 XI-64.1 XFP I-64.1/10GBE BASE L 1AB214540001 t.b.d
29-06-2015
25/26
34/35
35 1 SS-16.1
1 XI-64.1 XFP I-64.1/10GBE BASE L
OPTO TRX SFP S-16.1 DDM -5/+85 1AB 196370006 t.b.d
O-16ES
Card
Pos.
Mod.
Pos.
x
…
…
Ezbet Elborg L2
Cable List 48V DC Power Supply 1660 SM # 02
Part 2 02 page 13 Version 2.0
Alcatel-Lucent - Proprietary
Use pursuant to company Instructions - All Rights ReservedA4
A 4 03
1
A 4M2-2
M8-1
M2-1
M8-2
N1
TRU_M8< >1660SM_03/2/N2/FAN POWER
Bay Shelf
TRU_M2< >1660SM_03/1/N1/FAN POWER
Slot
N22
Label
From TRU to Fan Unit Shelf
TRU To: Fan Unit Shelf
Row Bay Power-Output Row
Cable Type: Power Cord 48V (delivered with shelf)
12
To:
M7-2
M1-2
M1-1
M7-1
Cable Type: CA-CORD PLUG ALIM. part of kit - 3AL91653AAAA
From : DC BOX TRU
To 1660SM Shelf
Label
DC BOX_…/DC BOX/ModB/…< >TRU_A/4/b-
DC BOX_…/DC BOX/ModB/RET< >TRU_A/4/b+
4
BayPower
InputLength
BLUE
RowRow Bay Mod Fuse/ Size
DC BOXa+
16mm2
Size Colour
a-BROWN
A
From Power Distribution Frame to TRU
BayPower-Output Row
Cable Type: Power Cable (See below for sizes)
… ADC BOX_…/DC BOX/ModA/RET< >TRU_A/4/a+
DC BOX_…/DC BOX/ModA/…< >TRU_A/4/a-
DC BOX
10m
B...A
10m
...A
RET
RET
b-16mm2
+Bat.A 4
+Bat.
-Bat.
BLUE
BROWN
Slot
TRU
29-06-2015
b+
From TRU to 1660 SM
Row LabelShelf
Attention: For detailed information see Technical Handbook Version 8DG 15642 AAAA R5,5
…
TRU_M1< >1660SM_02/10/POWER
Bay
TRU_M7< >1660SM_02/12/POWER
4A-Bat.
10
02
Conn.
x
Ezbet Elborg L2
Cable List Grounding 1660 SM # 02
Part 2 02 page 14 Version 2.0
Alcatel-Lucent - Proprietary
Use pursuant to company Instructions - All Rights ReservedA4
YL/GR
29-06-2015
YL/GR
Label
FRMGND
YL/GR 1660SM#01 GND N/A
YL/GR
Equipment Grounding
Cable Type: see below
From: Bay Ground Rail Bar
Cable To: equipment
Colour TypeEquipment
Name Input
Connector Label
… EARTH BAR ... A 04 FRMGND RGRB_…/EARTH BAR/...< >BGRB_A/4/FRMGND
Cabinet Grounding
Cable Type: Power Cab. 1x16mm² Yel Green
From: EARTH BAR To: Bay Ground Rail Bar
Row Bay Connector Row Bay
20
2
A4
Attention: Use the same label for both fibre ends
x Use
pu
rsu
an
t to c
om
pa
ny In
stru
ctio
ns - A
ll Rig
hts
Re
se
rve
d
Alc
ate
l-Lu
ce
nt - P
rop
rieta
ry
STM-64
ODF
0
34/35 1
connections 1660SM to ODF
The following connections are to be made using cable type: OPTICAL JUMPER SM LC/SCS 10M/20
Pa
rt
ST
M-6
4 c
on
ne
ctio
ns
16
60
SM
to O
DF
Ezb
et E
lbo
rg L
2
From: 1660SM To: ODF
Name Row Bay Shelf Slot Port Conn. Length [m] Name Row Bay Shelf Side Port Label
1660SM A 4 02 25/26 1IN 10 A 5 01 Front 3 1660SM_A/4/02/25/26/1/IN < >ODF_A/5/01/Front/3
IN 10 ODF
OUT 10 ODF A
5 01 Front 7 1660SM_A/4/02/34/35/1/IN < >ODF_A/5/01/Front/7
5 01 Front 4 1660SM_A/4/02/25/26/1/OUT< >ODF_A/5/01/Front/4
OUT 10 ODF A 51660SM A 4 02
IN 0
1660SM_A/4/02/34/35/1/OUT< >ODF_A/5/01/Front/8
01 Front 8
A
1660SM 0 0 0 35 11660SM_0/0/0/35/1/OUT< >0_0/0/0/0/6
0 0 0 0 5 1660SM_0/0/0/35/1/IN < >0_0/0/0/0/5
OUT 0 0 0 0 0 0 6
29
-06
-20
15
pa
ge
15
16
60
SM
# 0
2
Ve
rsio
n2
.0
20
2
A4
Attention: Use the same label for both fibre ends
x Use
pu
rsu
an
t to c
om
pa
ny In
stru
ctio
ns - A
ll Rig
hts
Re
se
rve
d
Alc
ate
l-Lu
ce
nt - P
rop
rieta
ry
1GbEth
ODF
1660SM A 4
connections 1660SM to ODF
The following connections are to be made using cable type: OPTICAL JUMPER SM LC/SCS 10M/20
Pa
rt
1G
bE
th c
on
ne
ctio
ns
16
60
SM
to O
DF
Ezb
et E
lbo
rg L
2
From: 1660SM To: ODF
Name Row Bay Shelf Slot Port Conn. Length [m] Name Row Bay Shelf Side Port Label
1660SM A 4 02 17
1IN 10 A 5 02 Rear 34 1660SM_A/4/02/17/1/IN < >ODF_A/5/02/Rear/34
OUT 10 ODF A 5 02 Rear 33 1660SM_A/4/02/17/1/OUT< >ODF_A/5/02/Rear/33
2IN 10 ODF A 5 02 Rear 36 1660SM_A/4/02/17/2/IN < >ODF_A/5/02/Rear/36
OUT 10 ODF A 5 02 Rear 35 1660SM_A/4/02/17/2/OUT< >ODF_A/5/02/Rear/35
3IN 10 ODF A 5 03 Rear 2 1660SM_A/4/02/17/3/OUT< >ODF_A/5/03/Rear/2
OUT 10 ODF A 5 03 Rear 1 1660SM_A/4/02/17/3/OUT< >ODF_A/5/03/Rear/1
4IN 10 ODF A 5 03 Rear 4 1660SM_A/4/02/17/4/OUT< >ODF_A/5/03/Rear/4
OUT 10 ODF A 5 03 Rear 3 1660SM_A/4/02/17/4/OUT< >ODF_A/5/03/Rear/3
02 17
1IN
OUT4
1660SM_A/4/02/17/1/IN < >_///
OUT 1660SM_A/4/02/17/1/OUT < >_///
pa
ge 2
IN 1660SM_A/4/02/17/2/IN < >_///
OUT 1660SM_A/4/02/17/2/OUT < >_///
16
3IN 1660SM_A/4/02/17/3/OUT < >_///
OUT
IN
1660SM_A/4/02/17/3/OUT < >_///
1660SM_A/4/02/17/4/OUT < >_///
1660SM_A/4/02/17/4/OUT < >_///
0 1660SM_A/4/02/28/1/IN < >0_0/0/04/0/2
1660SM A 4 02 28
1IN 0
04
0 0 04 0 2
0
OUT 0 0 0 0
0 1 1660SM_A/4/02/28/1/OUT< >0_0/0/04/0/1
16
60
SM
# 0
2
2IN 0 0 0 04 0 4 1660SM_A/4/02/28/2/IN < >0_0/0/04/0/4
3 1660SM_A/4/02/28/2/OUT< >0_0/0/04/0/3
3IN 0 0 0 0
OUT
OUT 0 0 0 0
00 0 0 0 04
0
04 0 6 1660SM_A/4/02/28/3/OUT< >0_0/0/04/0/6
04 0 5 1660SM_A/4/02/28/3/OUT< >0_0/0/04/0/5
04
0 04 0 8 1660SM_A/4/02/28/4/OUT< >0_0/0/04/0/8
1
OUT 0 0 0 04
IN 0 0
04
0 7 1660SM_A/4/02/28/4/OUT< >0_0/0/04/0/7
1660SM A 4 02 29
10 1660SM_A/4/02/29/1/IN < >0_0/0/04/0/10
Ve
rsio
n
OUT 0 0 0 0
IN
2IN 0 0 0
00 0 0 0
04 0 9 1660SM_A/4/02/29/1/OUT< >0_0/0/04/0/9
04
0 04 0 12 1660SM_A/4/02/29/2/IN < >0_0/0/04/0/12
0
OUT 0 0 0 0
0 11 1660SM_A/4/02/29/2/OUT< >0_0/0/04/0/11
2.0
3IN 0 0
04
0 04 0 14 1660SM_A/4/02/29/3/OUT< >0_0/0/04/0/14
0
OUT 0 0 0 0
0
0 13 1660SM_A/4/02/29/3/OUT< >0_0/0/04/0/13
4IN 0 0 04 0 16 1660SM_A/4/02/29/4/OUT< >0_0/0/04/0/16
0 15 1660SM_A/4/02/29/4/OUT< >0_0/0/04/0/15
29
-06
-20
15
OUT 0 0 0 0 04
20
2
A4
Attention: Use the same label for both fibre ends
31 1660SM_A/4/02/14/12/OUT< >ODF_A/5/04/Rear/31
29
-06
-20
15
32 1660SM_A/4/02/14/11/OUT< >ODF_A/5/04/Rear/32
OUT 10 ODF A 5 04 Rear12
IN 10 ODF A 5 04 Rear
OUT 10 ODF A 5 04 Rear 29 1660SM_A/4/02/14/11/OUT< >ODF_A/5/04/Rear/29
A 5 04 Rear 30 1660SM_A/4/02/14/10/OUT< >ODF_A/5/04/Rear/30
04 Rear 27 1660SM_A/4/02/14/10/OUT< >ODF_A/5/04/Rear/27
2.0
11IN 10 ODF
04 Rear 28 1660SM_A/4/02/14/9/OUT< >ODF_A/5/04/Rear/28
OUT 10 ODF A 510
IN 10 ODF A 5
5 04 Rear 25 1660SM_A/4/02/14/9/OUT< >ODF_A/5/04/Rear/25
04 Rear 26 1660SM_A/4/02/14/8/OUT< >ODF_A/5/04/Rear/26
Ve
rsio
n
OUT 10 ODF A
Rear 23 1660SM_A/4/02/14/8/OUT< >ODF_A/5/04/Rear/23
9IN 10 ODF A 5
OUT 10 ODF A 5 04
5 04 Rear 24 1660SM_A/4/02/14//OUT< >ODF_A/5/04/Rear/24
04 Rear 21 1660SM_A/4/02/14/7/OUT< >ODF_A/5/04/Rear/21
8IN 10 ODF A
04 Rear 22 1660SM_A/4/02/14//OUT< >ODF_A/5/04/Rear/22
OUT 10 ODF A 5
Rear 19 1660SM_A/4/02/14/6/OUT< >ODF_A/5/04/Rear/19
7IN 10 ODF A 5
Rear 20 1660SM_A/4/02/14//OUT< >ODF_A/5/04/Rear/20
OUT 10 ODF A 5 04
1660SM_A/4/02/14/5/OUT< >ODF_A/5/04/Rear/17
16
60
SM
# 0
2
6IN 10 ODF A 5 04
ODF A 5 04 Rear 17
04 Rear 18 1660SM_A/4/02/14/5/IN < >ODF_A/5/04/Rear/18
OUT 10
Rear 15 1660SM_A/4/02/14/4/OUT< >ODF_A/5/04/Rear/15
5IN 10 ODF A 5
Rear 16 1660SM_A/4/02/14/4/OUT< >ODF_A/5/04/Rear/16
OUT 10 ODF A 5 04
13 1660SM_A/4/02/14/3/OUT< >ODF_A/5/04/Rear/13
4IN 10 ODF A 5 04
14 1660SM_A/4/02/14/3/OUT< >ODF_A/5/04/Rear/14
OUT 10 ODF A 5 04 Rear
17
3IN 10 ODF A 5 04 Rear
OUT 10 ODF A 5 04 Rear 11 1660SM_A/4/02/14/2/OUT< >ODF_A/5/04/Rear/11
A 5 04 Rear 12 1660SM_A/4/02/14/2/IN < >ODF_A/5/04/Rear/12
04 Rear 9 1660SM_A/4/02/14/1/OUT< >ODF_A/5/04/Rear/9
pa
ge 2
IN 10 ODF
04 Rear 10 1660SM_A/4/02/14/1/IN < >ODF_A/5/04/Rear/10
OUT 10 ODF A 51
IN 10 ODF A 5
04 Rear 7 1660SM_A/4/02/33/4/OUT< >ODF_A/5/04/Rear/7
1660SM A 4 02 14
Rear 8 1660SM_A/4/02/33/4/OUT< >ODF_A/5/04/Rear/8
OUT 10 ODF A 5
5 1660SM_A/4/02/33/3/OUT< >ODF_A/5/04/Rear/5
4IN 10 ODF A 5 04
10 ODF A 5 04 Rear
5 04 Rear 6 1660SM_A/4/02/33/3/OUT< >ODF_A/5/04/Rear/6
04 Rear 3 1660SM_A/4/02/33/2/OUT< >ODF_A/5/04/Rear/3
3IN 10 ODF A
Rear 4 1660SM_A/4/02/33/2/IN < >ODF_A/5/04/Rear/4
OUT 10 ODF A 5
1 1660SM_A/4/02/33/1/OUT< >ODF_A/5/04/Rear/1
2IN 10 ODF A 5 04
2 1660SM_A/4/02/33/1/IN < >ODF_A/5/04/Rear/2
OUT 10 ODF A 5 04 Rear
10 ODF A 5 04 Rear
A 4 02 33
1IN
OUT
Bay Shelf Side Port Label
ODF
Name Row Bay Shelf Slot Port Conn. Length [m] Name
STM-1 connections 1660SM to ODF
The following connections are to be made using cable type: OPTICAL JUMPER SM LC/SCS 10M/20
Pa
rt
ST
M-1
co
nn
ec
tion
s 1
66
0S
M to
OD
F
Ezb
et E
lbo
rg L
2
From: 1660SM
x Use
pu
rsu
an
t to c
om
pa
ny In
stru
ctio
ns - A
ll Rig
hts
Re
se
rve
d
Alc
ate
l-Lu
ce
nt - P
rop
rieta
ry
To:
Row
1660SM
20
2
A4
For more details about Aux. plug pin-out see Appendix B, C
Slot Port Length [m]
Existing DDF … …
Slot
A 4 02 11
Row Bay/Frame
S2 … …/…
Shelf
…
Termination
blockPort
1660SM_A/4/03/10/C2< >FAN SHELF_A/1/…/M2-M3
Aux. Channels connections
Cable:
034
15
C4
NameRow
Length [m] Name
Name
C2 1,5 FAN SHELF
Port
M2-M3
Bay Shelf
… … 1660SM_A/4/02/12/C2< >Existing DDF_…/…/…/…/…
Label
1660SM_A/4/02/11/S2< >Existing DDF_…/…/…/…/…
Slot Port
Cable:
C2
Port
12
1660SM
15
15
Block
Bay
3AL18034CNAA - CLEE 2 Q HF HE5-15MC/15M
1660SM To: FAN SHELF
3AL17956HLAA - DF CORD 4Q HF HE5-15M-C 25 M
Existing DDF
Label
1AB200480001 - DF CORD 33P HF HE5-50M 25 M
Termination
blockPort Label
VDS - Aux. Channels connections
1660SM
Pa
rt
Ezb
et E
lbo
rg L
2
From:
Row
From:
Name Row Bay
Use
pu
rsu
an
t to c
om
pa
ny In
stru
ctio
ns - A
ll Rig
hts
Re
se
rve
d
Alc
ate
l-Lu
ce
nt - P
rop
rieta
ry
18
x
Row Bay
2.0
29
-06
-20
15
16
60
SM
# 0
2
A 10
Row Bay
Ve
rsio
n
Cable:
Shelf Slot Port
To: TRU 6/6
Port
From: 1660SM
Name
Row Bay/Frame
From:
Slot
1660SM
Row
Name
1660SM A
Attention: Use the same label for both cable ends
A 4 … …/…
Length [m]Name
Slot
1660SM
Row Bay Shelf
02
03 05 1
Name Connector
…IN
Row BayLength [m]
4
Ex
tern
al c
on
ne
ctio
ns
of 1
66
0S
M
pa
ge
Name
1660SM
Cable:
From:
Aux. Channels connections
Aux. Channels connections
Cable: 1AB200670004 - CLER ALA HE5-9M 25 M
Housekeeping - Aux. Channels connections
1660SM_A/4/03//IN< >ALARM TRU_…/…/05/1ALARM TRU …
Bay Shelf
1660SM
1AB200460001 - CLEE 5P HE5-9M/9F
Label
A 1
01 Pos.1
Shelf Port
10 C3 RACK ALARM
Length [m] Name Label
1660SM A 4 02 1660SM_A/4/02/10/C3< >RACK ALARM_…/02/01/Pos.1… 02
20
2
A4
1660SM_A/4/02/11/J3< >Existing DDF_…/…/…/…/…Existing DDF … …/…
Sy
nc
hro
niz
atio
n fo
r 16
60
SM
pa
ge
Name
1660SM
Bay Shelf
… …
Name Port
Attention: Use the same label for both cable ends
Termination
block
16
60
SM
# 0
2
Ve
rsio
n2
.02
9-0
6-2
01
5
Use
pu
rsu
an
t to c
om
pa
ny In
stru
ctio
ns - A
ll Rig
hts
Re
se
rve
d
Alc
ate
l-Lu
ce
nt - P
rop
rieta
ry
19
x
Pa
rt
Ezb
et E
lbo
rg L
2
From:
Row
1660SM
Telephone handset connections
From: 1660SM
1660SM
15
Row Bay/FrameLength [m] Label
1102
15
J3
J4
Slot Port
I/O 2 MHz Synchronous interfaces -CLER 4P HF 1.0/2.3 BAL 25 m - 1AB200560001
1660SM_A/4/02/11/J7< >Existing DDF_…/…/…/…/…… …/… … …
1660SM_A/4/02/11/J4< >Existing DDF_…/…/…/…/……
4A
…
Existing DDF
… …/…15 Existing DDF
J7
J8
J7
J8
J5
J6
15 Existing DDF … …/… … … 1660SM_A/4/02/11/J8< >Existing DDF_…/…/…/…/…
XX YY 1660SM_A/4/02/11/J5< >_XX/YY//
XX YY 1660SM_A/4/02/11/J6< >_XX/YY//
XX YY 1660SM_A/4/02/11/J7< >_XX/YY//
XX YY 1660SM_A/4/02/11/J8< >_XX/YY//
Name Row Bay Shelf Slot Port Length [m] Name
For more details about Aux. plug pin-out see Appendix D, E
Label
PJ777 Phone
Row Bay Panel Port
A 4 02 11 A 4 1660SM_A/4/02/11/PJ777< >Phone_A/4//
20
2
A4
4A 02
A 4
FAN SHELF A 4
To: EQUIPMENT
A
TRU
Bay Shelf Port Slot
1660SM
Row Bay
29
-06
-20
15
1660SM_A/4/02/10/HK< >FAN SHELF_A/4//N3HK N3
Ezb
et E
lbo
rg L
2
1660SM
Connection TRU to Extension Alarm Unit
The following connections are to be made using cable type:
Row Length [m]
Connection 1660SM to OfficeAlarmBay
Name Name LabelPort
From:
Slot
Use
pu
rsu
an
t to c
om
pa
ny In
stru
ctio
ns - A
ll Rig
hts
Re
se
rve
d
Alc
ate
l-Lu
ce
nt - P
rop
rieta
ry
20
x
Pa
rt
Ex
tern
al c
on
ne
ctio
ns
of 1
66
0S
M
Attention: Use the same label for both cable ends
16
60
SM
# 0
2
Ve
rsio
n2
.0p
ag
e
1660SM
1660SM_A/4/02/10/RACK< >TRU_A/4//M2
Q2 FAN SHELF
A 4 M2RACK
1660SM_A/4/02/10/Q2< >FAN SHELF_A/4//N3
10b2 IN
A 4 N3
1660SM_A/4/02/10/10b2 IN< >_///
10b2 OUT
10bT
HK02 1660SM_A/4/02/12/HK< >_///
_////< >_///
_////< >_///
10
1660SM_A/4/02/10/10bT< >_///
1660SM_A/4/02/10/10b2 OUT< >_///
12
3EC 40591 AA--
_////< >_///
From: TRU To: EXTENXION ALARM UNIT
Name Row Bay RU Slot Port Length [m] Name Row Bay Slot Port
N/A M1 N/A EXT ALMTRU A 4 4
NOTE : ESPAL CABLE IS PROVIDED TOGETHER WITH TRU
FOR MORE DETAILS ABOUT PLUGS PIN-OUT SEE APPENDIX B
Connection Extension Alarm Unit to Equipment
4 N/A M1 N/A
Label
From: EXTENSION ALARM UNIT To: EQUIPMENT
Name Row Bay RU Slot Port Length [m] Name
M2 FAN SHELF
LabelCableRow Bay Slot Port
M3 1660
EXT ALM/A/4/M2< >FAN SHELF/A/SDH/1/M1A SDH 1 M1
M4
EXT ALM/A/4/M3< >1660/A/SDH/10/RACK LAMPA SDH 10 RACK LAMP
M5
A
A
M7
AM6
4 4 N/A
3AL 79457 AAAA
A
A
The following connections are to be made using cable type: 3AL18034CNAA - CLEE 2 Q HF HE5-15MC/15M, ALARM CORD 3AL34964AAAA part of fit 3AL91653AAAA
M8
EXT ALM A
Ezbet Elborg L2
Appendix D 1660 SM # 02
Part 2 02 page 21 Version 2.0
Alcatel-Lucent - Proprietary
Use pursuant to company Instructions - All Rights ReservedA4
"HK" connector C2 mounted on the “Control and General I/F unit (CONGI)” (slot 10 and 12.)
"RACK" connector C3 mounted on the “Control and General I/F unit (CONGI)” (slot 10).
"Q2" connector C4 mounted on the “Control and General I/F unit (CONGI)”.(slot 10)
29-06-2015
Ezbet Elborg L2
Appendix E 1660 SM # 02
Part 2 02 page 22 Version 2.0
Alcatel-Lucent - Proprietary
Use pursuant to company Instructions - All Rights ReservedA4
G.703, RS 232 and V11 Aux. Channels connections
29-06-2015
Ezbet Elborg L2
Appendix F 1660 SM # 02
Part 2 02 page 23 Version 2.0
Alcatel-Lucent - Proprietary
Use pursuant to company Instructions - All Rights ReservedA4
G.703, RS 232 and V11 Aux. Channels connections
29-06-2015