REPORT Technical Report: (8513)362-0134
Page 1 of 20 JAN 08, 2014
BUREAU TEST REPORT VERITAS
MONDAY BEAUTY LTD 2810, 28/F PAULY CENTRE, 51 HUNG TO ROAD, KWUN TONG, HONG KONG
ATTN:
CC:
SUNNY YU I EAGLE I DOROTHY I JOVI /GARY [email protected] [email protected] [email protected] [email protected] [email protected]
LAB LOCATION: LAB NUMBER:
DATE IN:
MOD. LOG IN: DATE OUT: REVISED DATE: WORKING DAYS: PAGE:
SHENZHEN (8513)362-0134
DEC 30,2013
I JAN 08,2014 I 7 20F 20
OVERALL RATING
PASS FAIL DATA
TESTING FOR CANDLE I FILLED CANDLE (V1)
CPSD - 09400 - US
Sample Description: 16CT CANDLE WITH DECORATION (2 ASSORTED STYLE) Manufacturer: I P.O. No.: I Buyer: OWN NAME Style: I Country of Origin: CHINA Country of Destination: USA Color: I SKU Number: G24706 Re-test: Yes: I I No: I X I Char!le Vendor: Yes: I X I Previous Report No.: I
X
No: I I
llUREAU VEHITAS
REMARK:
-See enclosed protocol for test results.
-As per vendor request, only performance test was conducted in this report.
(8513)362-0134 Page 3 of 20
NOTE: If there are questions or concerns regarding above report, please contact the appropriate Jab persons.
Technical questions & concerns:
General Enquiries:
Mealson Huang I Lester Luo (+86)755-86000151 ( Ext 6224/6663) [email protected] [email protected]
Ada Zhu/ Annie Luo (+86)755-86000151 (Ext6265/6238) [email protected] [email protected]
BUREAU VERITAS SHENZHEN CO., LTD
JASON WONG MANAGER- HARDLINES DIVISION
# Califomia Proposition 65
Candlcholdcr
supplemental
Applicable section from Protocol CPSDAN-PTCL-06572-US
CPSD-IIL-PTCL-09425-US
I'
testing
X
X
; 1 to dctennine if X
BV Lab Number:
Technician Name:
Test Date:
Reviewed By/Date:
X X
X X
X X
NT
NT
NT
(8513)362-0134
AMY
DEC31-JAN 08,2014
ADEM/JAN 08,2014
Pagc4 of20
** Candle- FPLA
Candles with pesticides or claims to control or mitigate disease vectors- (e.g., Lyme's disease or West Nile Virus)
16 CFR 501.7
EPA Registmtion Requirement I FIFRA 25 (b) Exemption/40 CFR 152/ CPSD-HL-
09400-STIP
Tapered candles and irregularly shaped decorative candles, which are either hand dipped or molded, do not need to be labeled with the diameter of the candle. The candles must be labeled with count and length or height in inches to meet the requirements offPLA.
{See corresponding Table T-0041 at the end ofthis
" (such as i i vectors -e.g., Lyme's disease or West Nile Virus) it must be EPA registered. l.The label must include an EPA registration number. 2. Tiw vendor must provide proof of EPA registration - Lab will review documentation.
If the candle is not registered, it must comply with ALL of below labeling exemptions of FlfRA & 40 CFR 152: 1. It does not bear a claim to control or mitigate disease vectors (label can have genernllabeliug- repels bugs; repels mosquitos; or have a picture of a dead bug) 2. The active ingredients are listed in the FIFRA 25(f)(l) list 3. The product contains inert ingredients from the approved FIFRA list (Paraffin) (Colorants are not listed);
'"' 4. It
13V Lab Number: (8513)362-0134
Technician Name: AMY Test Date: DEC 31-JAN 08,2014
Reviewed By/Date: ADEM/JAN 08, 2014
Page 5 of20
X X X NT
X X X NT
Fire safety warning ASTM F2058-07
section 6.3
Text Only Options: Shall consist oft he safety alert symbol (Sec image appendix "0-0012 ASTM F2058-07 4.1 Safety Alert Symbol" at the end of protocol) followed immediately by the word "\V ARN1NG" in uppercase boldfhee letters.
The following fire safety warning statements or practical equivalents shall appear in this order:
Bum within sight Keep away from things that catch fire Keep away from Children
These may appear in stacked fommt or paragraph fonn.
Abbreviated text only fire safety wamings arc pcmlissiblc for candles with warning panels 21 em' or less in size and for individually wrnpped taper candles.
X
BV Lab Number: (8513)362-0134
Technician Name: AMY Test Date: DEC 31-JAN 08,2014
Reviewed By/Date: ADEWJAN 08,2014
Page 6 of20
X X NT
BUREAU VEIUTAS TEST PROTOCOL FOR CPSJl ~ 09400 ~ US
CANllLE I Fll,LED CANDLE lVI \E~;ftiiiii:fiO"Q-p_-4;} 717 ;;I ""'-'' f%L:tt <t:;I:;ISPJ.k'' 'iiSitilfiltiOJi'-nJVretli'Ud L% 17!:># ,;_;:::;:~:-~tti-ft&::D~~:2i'V1¢£$fii'Jli'fJilJfiffiY:t'i%?1f:S:Yllki?Y
Text and Pictogmm Option;
fire safety warning
Lead in metal wick- metal-cored wicks
ASTM F2058-07 Section 6.4
16CFR 1500.17(a)(13)
Shall consist of the safety alert symbol followed immediately by the following pictograms:
{Sec corresponding Graphics G-0013 at cod of this protocol}
The following fire safety warning statements or practical equivalents shall appear in this order;
Bum within sight Keep away from things that catch fire Keep away from Children
These may appear in stacked format or paragraph form.
Abbreviated text and pictogram fire safety warnings nrc permissible for candles with warning panels 21 em' or less in size a11d for individually wrapped taper candles. The warning shall consist solely of the safety alert symbol followed by the bum within sight pictogram and the fire safety warning statement "Bum withi11 sight" or its practicol equivalent.
The outer container or wrapper of candles with metal-cored wicks (manufactured or imported on or after Oct. 15, 2003) must be labeled "Confom1s to 16 CFR 1500.17(a)(l))."
X
X
BV Lab Number;
Technician Name:
Test Date:
Reviewed By/Date:
X X
X X
(8513)362-0134
AMY DEC 31-JAN 08,2014
ADEM/JAN 08,2014
Page 7 of20
NT
NT
Claim verification- level2
.. Lead in metal wick
Flash point of liquid fragrance
CPSD-GB-08612-MTHD
16CFR 1500.3(c)(6)(iii) 116
CFR 1500.43(a)/ Ci'SD-AN-00036-
MTIID
Record each objective (factual) claim which can be substantiated by the testing within tbe protocols and rate accordingly.
Record testing that extend beyond existing net quantity I dimensional testing on this protocol.
Record all other objective (fh.ctual) and subjective (opinion) claims as "NT' and rate as "DATA".
Record infonnation evaluated between the graphic imagery and the product.
X
X
BY Lab Number: (8513)362-0134
Technician Name: AMY Test Date: DEC 31-JAN 08,2014
Reviewed By/Date: ADEM/JAN 08, 2014
Page 8 of20
X X NT
X X NT
X X NT
DEC 3 I -JAN 08,2014 g•"''• ' ' ; :,
78~1l
BY Lab Number:
Technician Name:
Test Date:
Reviewed By/Date·
(8513)362-0134
AMY
ADEM/JAN 08 2014
~ Page 9 of20 '
BUREAU VERITAS TEST PROTOCOl, FOR CPSD- 09400- US
I ~~S,',7,"'""':'•~I 1.ervn
I
1 ~~;;;~~~~ ~il.- 1 at the two .
• Polarity of fragrance CPSD-AN-00030-
X X NT I MTHD Note: -Raw material fragrance must be submitted if gel candle is rec~:h•ed.
I j '"""" ''"''""'" m;l,
• l· ifdoimod 1 Roport' ' ; '"" '"""'· X X NT I MTHD
Thl"' i '_"pplie<." oil ' \foe candles. Containe~ constructed of noncombustible materials
Safety requirements for plastic are exempt from this test. . containers (including tea light
ASTM F2417-ll X X X NT I
cup) SC\:tions 4.5 & 5.4 Must have a total burn time less than or equal to 300 s with
no si1Jglc bum time event exceeding 30 s when the containers are tested in accordance with the method in
I ""''" , .. !:~~~;~ ~I·R 1500.4• I ~::~~~:;',:;~::~:~;:"'"; I ; t of no greater
X X X NT I " li """"
Dimensions ''"".'"'' ffieOMO I I R<p'"-"''"" ' ; •boll moellobd doim'
t.i'l'!Io I X X NT I
CPSD-IIL-01056- I Soffidoo< \oog'" "' HgO<mg (Mm. W' Dimensions - length- wick MTIID J Standard X X NT I
'"'""" Weight MTIID I S<oode<d
1 Rop:rt ?~~~~::;~~;~)boll""" Iobei doio" (If X X NT I
m'"'""
Pe<t. '"""'"'Y MTHD I y;,.,l 1 Sholl moo<lohd cloio'".
X X NT I
BUREAU VERITAS TEST PROTOCOL FOR CPSD- 09400- US
CANDLE I FILLED CANDLE (Vi\
BV Lab Number:
Technician Name:
Test Date:
Reviewed lly/Date:
(8513)362-0134
AMY
DEC 31-JAN 08,2014
ADEM/JAN 08, 2014
Page 10 of20
l!E:\'•iiiii~110lf<Pi0:Z0f0'tiiif4'%S?$Wf?Si:~¥t0st1+:;;i 3 JZ.ifCJtilii'OilU!J\1£t!IO~f20 ;?${!t;i&i05k,s£ <fe~!?ff,tt:2&[;r:i?'t!flte'i'firdi:~;L :\t:i¢S;g~f!:~f:'WJ:0~5::4 ¥1Ysliit± t:i'\Sffii'£ }3'Sfirf2 %')(':')';;i%"'-RilS'U!fMflt3Cc\~i 0ii0~'¥3JRlldil Yi<lj2t;le;;G CPSO-HL-01057- Report actual.
Wick analysis- dimensions and MTIID I Visual/ CPSD-IIL-01056- X X NT
shape MTIID I Standard measure
Wick analysis- construction, type, CI'SD-HL-0!057- Report actuaL X X NT
defects, etc. MTHD I Visual
Wick analysis- number of wicks CPSD-JIL-01057- Report actuaL
X X NT MTIID I Visual
WORKMANSHIP
16 CFR 1500.48 I Shall have no sharp points I edges, other than those required Sharp points and sharp edges 1500.49 modified
for function. X X NT Modification= Expm1dcd scope to other products Shall have no discemible surface degradation, including
Defects CI'SD-HL-01057- crazing, shivering, denting, bubbles, crncks, stains,
X X NT MTJID/ Visual dcfomtations, chips, frncturcs, heavy lines, waves, shear marks, scratches, scuff marks, indentations, or blisters.
CPSD-HL-01057-Shall have no components missing, malfonned, and/or
Workmanship MTHD I Visual fractured. X X NT
Aesthetic Evaluation CPSD-IIL-01057- Shall be free ofbubbles, cracks, chips, or dents except when
X X NT MTIID I Visual they arc intended as part oft he design I pattcm. PERFORMANCE Candles are bumcd for 8-hour c clcs Ulltil end of useful life.
BV Lab Number: (8513)362-0134
Technician Name: AMY
Test Date: DEC 31-JAN 08,2014
Reviewed By/Date: ADEM/JAN 08,2014
iiiDli'D:Di ,,, 0 I' II f20
BUREAU VERITAS TEST PROTOCOL FOR
.... f •. ~CPSD:0940-1 Tl,,, ~·'~:', · ;·~.::J::;::'"" ""''"" intended tO be-bumed •
The 76.2-mm (3.0-in.) maximum allowable flame height requirement for all candles excluding Easter, Paschal, sacramental, altar and outdoor candles.
ASTMF2417-11 M
Safety requirement for !lame scctions4.1 &5.2 The 95.3-mm (3.75-in.) maximum allowable flamo height Af MAX: 1-3/81N
height modified I CPSD-HL-requirement for Easter, Pasclml, sacmmcntal, and altar X X X MIN: liN PASS Candles. "' MAX:l-3/81N
09401-MTHD MIN:I-l/81N Maximum allowable flmnc height requirement for tcalight/ birthday candles is 2-in. Results for outdoor candles shall be reported as data only.
Modificatio11"' flame height requirement for tealights I I
Thi.' ~."'"'' i :~;~,:;.:::';~::1:11 · I I '""mbl" with the e~cePtion 1 Paschal, and sacramental candles specifically designed to be used during the service at the
ASTMF2417-ll place
Safety requirements for secondary sections 4.2 & 5.2 I of worship.
ignition CPSD-HL-09401-X X X M PASS
Shall be tested in accordance with 5.2 of this specification, MTHD no secondary ignition shall occur.
Rec~rd th.e candle as passing the secondary ignition
' if no secondary ignition is observed during the lt;,liog.
Safety requirements fur end of useful life
ASTM F2417-ll sections 4.3 & 5.21 CPSD-HL-09401-
MTHD
Record votive and filled (including tealights) candle or tea light ensembles as passing the end ofuscfi.lllife requirement when tested in accordance with the test method in 5.2 if the candle or tea light ensemble meets the definition in 3.2.6 and docs not break or crack the container, does not exhibit excessive flame height, and docs not exhibit secondary ignition as detailed in this specification.
Record the freestanding candle as passing the end of useful life requirement when tested in accordance with the test method in 5.2 if the candle meets the definition in 3.2.6 and the fl3me does not impinge on the snpporting surface, docs not exhibit excessive flame height, docs not exhibit secondary ignition as detailed in this specification, and docs not tip over on its own accord when tested on a level surface in accordance with 5.2.
X
BV Lab Number:
Technician Name:
Test Date:
Reviewed By/Date:
X X NA
(8513)362-0134
AMY DEC 31-JAN 08,2014
ADEM/JAN 08, 2014
Page 12 of20
Safety requirement for stability
Actual use- functionality- not covered by other tests
ASTM F2417-11 sections 4.4, 5.2 & 5.3
I CPSD-lll-09400-MTIID
Actual usc I CPSD-llL-01058-MTIID
arc nom1ally used without the aid of a device to keep them upright, filled candles (including tealights), and ensembles. Candles requiring a holder to keep them \lpright and votive candles arc excluded unless they are incorporated in an ensemble. Easter, Paschal, sacramental, and altar candles specifically designed for use during the service at the place of worship are also excluded from the requirements of this section.
Cm1dlcs that do not require a holder to keep them upright, shaH not tip over when placed on a minimum 10" incline.
Rotation around vertical axis is required for items that are not symmetrical in all 360° around its vertical axis.
Candles must remain stable when tested on a level Sllrfacc in
X
llV lab Number: (8513)362-0134
Technician Name: AMY
Test Date: DEC 31-JAN 08,2014
Reviewed By/Date: ADEM/JAN 08,2014
Page 13 of20
X X NA
X X M PASS
I' • • . ' ; ~
1&:tU
Buming Characteristics I Abnonnalities
Afterglow
Bunting time
ASTMF2417-ll section 5.2 modified I
CPSD-IIL-09401-MTIID
CPSD-HL-09401-MTHD
m1y characteristic nonnal and/or expected performance ofthc product, such as the ejection of component material, the creation of!mzardous conditiOIJS, etc.) during bum performance testing including:
-Flaring. -Sparking. -Popping. -Explosion of material that was embedded in the candle. - Noxious odours. - Soot build-up - Visual smoke - Ovcrnow
Modification= additional criteria not covered in ASTM F2417.
(Report claimed & actual length ofbum time in hours)
llV Lab Number: (8513)362-0134
Technician Name: AMY Test Dale: DEC 31-JAN 08,2014 Reviewed By/Date: ADEM/JAN 08, 2014
Page 14 of20
X X M PASS
X X M PASS
C:/ X X R: A: 14MINUTES
H:\5MINUTES
BV Lab Number: (8513)362-0134
TeehnicianName: AMY
Test Date: DEC 31-JAN 08,2014
Reviewed Ry/Date: ADEM/JAN 08, 2014
~ Page 15 f20 0
BUREAU VERITAS TEST PROTOCOL JIOR
CPSD- 09400- US
. ·c··.· .. ~:.,.,,.~ · oootirem•t.;d"""'";,"" ·
Report the material type, maximum temperature and location.
UL 153 12th Edition Surface tcmpcmturc shall not exceed listed material limits:
# Container temperature- filled Table 125.1 modified Max. Temp: Metal- 125 °F J Glass and other materials -140 X NA I candles and tealights J CPSD-HL- 'F
09401.01-MTHD Note: Filled J container type candles only.
Modification= Expanded scope to other products
'if.~~·::t;"""'· Sholl oo< <eO<k oc # Cm1dle holder- nammability test
CPSD-HL-09402- o·i;~~r~0o;:~e X NA I MTHD
. ~~ndii[o;~~: w;,.," ; " '.~~?.""' "" .. inside knuckle ofthc article. The11 scratch an "X" across the entire inside bottom surface ofthe article. AI! scratches arc to be made using suflicient pressure to penetrate the surface of the glass.
Glass properties- effectiveness of ASTM F2179-02 After using either method, fill each article with water at the
' annealing- filled glass holders (R2007) section4.1 same room temperature as the glass. Wait 15 minutes, then X NA I only modified empty the water and examine each piece for fractures.
Report the number of fractures, if any, for each test. If no breakage occurs- Break it to verity whether it's annealed or tempered glass. Note: CPSD-llL-09404-MTHD is a Modified method from ASTM F2179-02
I. r}g1~i_tabl: material which ca~ produce a # Sustained direct flame contact MT~?.:,;.~~o h· , foreseeable usc. X NOT REQUESTED I
BUREAU VERITAS TEST PROTOCOL FOR CPSD- 09400- US
CANDLE I FILLED CANDLE lVI \
llV Lab Number:
Technician Name:
Test Date:
Reviewed By/Date:
(8513)362-0134
AMY DEC 31-JAN 08,2014
ADEM/JAN 08, 2014
Page 16 of20
<EV_Iilf•'Ri16Il¥;}(4\G'):J?Ji[~-;~%i;2~i;;;,YXtkd;-10'$l SA:tif(iiti'Oif:'lil\l.I!Ui'ii'd -it' Ti'i!Ai:s :x'3i'J:-'%i3!£%%~EB:~'&:%1!Hfitf1ii'%$i@'i18!06:?.d&f!~tr.\G"&"#iN0?>4 ;":'f-Starl. f'iiSta·r:-:· §:ii~ffif~$ 4!:!-%£:/'FiR'WU1iS!b\S;\t?i: :!026f'":~lfilfiir' !i[!fi!V:'ii!£0§
Glass properties- thennal shockfilled glass holders only
Resistance to corrosion
ASTM F2179-02 (R2007) Section 4.21
ASTM Cl49-05
ASTM 8117-11 modified I CPSD-llL-
01010-MTHD
Determine 1he cold-water bath temperature based on the available tap water 1cmpemture, and adjust the tcmpcmturc of the hot water bath to be 90° F higher than the cold water.
Once the temperature of the hot water bath has been established, place the samples in the hot water bath for 5 minutes.
Remove the samples from the hot water bath and place them into the cold-water bath with a time lapse of no more than 15 seconds. llc sure to empty the bot water out ofthe sample containers.
Maintain the samples in the cold-water bath for 30 seconds. Dry the containers and visually inspect for cmcking or fractmcs. Report findings. Any cracking or fmctures is considered a failure. [Applicable to samples I sample components constructed of metal or samples with metallic coatings that can be exposed to the environment]
Shall withstand 24 hours in I% salt spray (fog) with no noticeable oxidation I corrosion/ visual changes.
Modification = I% salt spray (fog).
X NA
X NA
#
Result Key: c R M NM NA NT
Rating Key: PASS FAIL
Additional Charge For This Test Mandatory Requirement By Request Only
Claimed Recorded Meets Docs Not Meet Not Applicable Not Tested
Pass Fail
BV Lab Number: (8513)362-0134 Technician Name: AMY
Test Date: DEC 31-JAN 08,2014
Reviewed By/Date: ADEM/JAN 08,2014 Page 17 of20
Jma eA 1cndix T-0041 16 CFR 501.7-FPJ,A-Candlcs.JPG
G-0012 ASTJ\1 F2058-07 4,1 Safely Alert Symbol.bmp
G-0013ASTM F2058-07 4.2-4.4 .. bmp
FPLA,CANDLES
CANDLE-· R·rorilim.M:Iillf
F'(ll~-_11/ ~IJ! · W:U_W_ei~t' Oi)o/
T_e_~ligl:l~ \=!01,1Q~:Ofio/
T~pe! {_I_q~~lar !.Jeigh~ ._o-~Y:
-Votivii;fGircutar; 'Hcl~t x Difttttehr
-V otiv:i). -q~;egt:il)lt< He:igl;tt'"cii!ly;
Pifiar /.CircUlar Hei~t-xl)iameter
:P;i\M ;sq1,1are :Fi:eight x Wiclih
'(IJS f;tatiil.afcl & Metric fo~·,ill-'¢6nq1~-s)
A"& Figure 1 Acceptable Safety Alert Symbols
® ~ @ "Bum within "Ke~p_aww "Ke'ejlfNfi1'J
sight" pictogr&u fmm things fmm.children" that catch fnll" piclograrn piclogr>lln
13V Lab Number:
Technician Name: Test Date;
Reviewed By/Date:
(8513)362-0134
AMY DEC 31-JAN 08,2014 ADEM/JAN 08,2014
Page 18 of20
6 additional for filled candles (for ASTM f2179) I 0 additional Tea Light Cups for tea light candles l n l
and
BV Lab Number: (8513)362-0134
Technician Name: AMY
Test Date: DEC 31-JAN 08,2014
Reviewed By/Date: ADEM/JAN 08, 2014
Client Approval: Creation Date: Last Revision Date: Pricing Review Date:
Technical Review Oat~::
Page 19 of20
I MAY 06,2013 MAY 13,2013
~UHEAU
VERITAS
Technical Report: (8513)362-0134
EXHIBIT # 01
Page 20 of 20 JAN 08, 2014