Specification Sheet AquaMaster Electronic Water Meter
Sizes 2 to 12
Integral or Remote Electronic Display Unit All user display requirements in a single unit
Submersible sensor and Electronic Display Unit Facilitates installation in all locations
including flooded pits.
Buriable sensor Eliminates chamber and ensures fast, low cost
installation
Wetted materials
Lining Elastomer (UKWFBS Listed)
Electrodes Stainless steel 316 L
Pressure LimitationsAs flange rating
Temperature LimitationsMedia (water) 14 - 158F
Ambient -4 - 140FStorage -22 - 158F
Conductivity> 50mS/cm
End Connections
FlangedANSI B 16.5 1.5 Class 150
Description
AquaMasters Principle of OperationIt measures flow of water in pipes by using Faradays princi-
ple of magnetic induction: a conductor (water) movingthrough a magnetic field will induce an electric current pro-portional to the velocity of the conductor. Water volume
through the meter can then be easily calculated.
Widest flow range, highest accuracy(up to 1500:1 turndown) Measures minimal night and peak day flows
Lowest cost of ownership
Rugged construction with no moving parts Ensures long, maintenance free life
Fit and Flow Foolproof installation; no on-site setup
Battery operation 3 year life
No external power supply required, facilitatesinstallation in remote locations
Operational temperature limits of the battery forspecified battery life: 32 - 122F
AC powered with optional battery backup Continuous measurement even during power-down
7/28/2019 4 y 6 pulgadas ABB AQUA MASTER.pdf
2/2
Meter Sizes, Flow Rates and Accuracies
ABB Water Meters, Inc.
www.abb.com/metering
United States Canada Caribbean Mexico
P. O. Box 1852 1200 Aerowood Drive -#35 P. O. Box 225 Calle Union 30Ocala, FL 34478-1852 Mississauga, Ontario L4W 2S7 Carretera 112 KM 2.3 Col. Tlatilco
352-732-4670 FAX 352-368-1950 905-238-9622 Isabela, PR 00662 Del. AzcapotalcoOutside Florida: 800-874-0890 800-670-5368 787-872-2006 CP 02860 MexicoInside Florida: 800-356-6829 FAX 905-238-5640 FAX 787-872-5427 52 53 56 3866
E-mail: [email protected] E-mail: [email protected] FAX 52 53 56 10 17
The companys policy is one of continuous productimprovement and the right is reserved to modify thespecifications contained herein without notice. Theseproducts have been manufactured with current tech-nology and in accordance with applicable AWWAStandards.
2001 ABB Water Meters, Inc. All rights reserved.
Flow Direction
>5 x pipe dia.
minimum
>2 x pipe dia.
minimum
45
Maximum
Sensor
Electrodes
Mounting
95% - 102%(GPM)
98% - 102%(GPM)
99.75% -
100.25%
(GPM)
95% - 102%(GPM)
98% - 102%(GPM)
99.50% -
100.50%
(GPM)
2 219 177 7.80 0.17 0.40 3.3 0.40 1.0 10
3 756 609 13.00 0.44 1.1 9 1.1 2.6 26
4 1,268 1,022 16.25 0.7 1.6 13 1.6 4.0 40
6 2,838 2,287 13.00 1.7 4.0 33 4.0 10 99
8 3,658 2,948 7.80 2.8 7 55 7 17 165
10 5,855 4,718 7.80 4.4 11 88 11 26 264
12 8,015 6,460 6.50 7 16 132 16 40 396
Low Flow Accuracy AC Powered
MetersMax.
Flow
(GPM)
Size
(in.)
Cont.
Flow
(GPM)
Pressure
Drop (PSI)
at Cont.Flow
Low Flow Accuracy Battery Powered
Meters (Inc. standby battery)
AM-Meter/03-01
Installation
Pipe Conditions
Nominal Dimensions
Meter Dimensions Approx.
Size A B Weight (lbs)2 7.0 7.9 22
3 8.6 7.9 404 9.1 9.8 53
6 11.1 11.8 978 15.8 13.8 112
10 17.3 17.7 132
12 18.9 19.7 154
BA