Via Nobili, 2 40062 Molinella (Bologna) - Italy DELPHI ITALIA AUTOMOTIVE SYSTEMS S.r.l. "Stabilimento Molinella"
Telefono (0039) 051.6906111 - Fax (0039) 051.6906287 - E-mail: [email protected]
"SANTANA"UNITÀ A/C A TETTOROOF TOP A/C UNIT
- CONFIGURATORE SISTEMA / SYSTEM CONFIGURATOR
- CARATTERISTICHE TECNICHE / TECHNICAL CHARACTERISTICS
2
INDICECARATTERISTICHE TECNICHE
CONFIGURATORE SISTEMA
- RACCORDI E TUBI GAS
- RACCORDI COMPRESSORE
- KIT RISCALDAMENTO (A031085)
- KIT RICIRCOLO ARIA (A031077)
- SANTANA XL (C/F + RIC)
- COMANDI
- PROLUNGHE ELETTRICHE
p. 3
p. 6
p. 8
p. 10
p.11
p.12
p.13
p.14
p.16
INDEXTECHNICAL CHARACTERISTICS
SYSTEM CONFIGURATOR
- FITTINGS AND GAS HOSES
- COMPRESSOR CONNECTION
- HEATING KIT (A031085)
- AIR RECIRCULATION KIT (A031077)
- SANTANA XL (C/F + RIC)
- CONTROLS
- ELECTRICAL EXTENSION
p. 3
p. 6
p. 8
p. 10
p.11
p.12
p.13
p.14
p.16
3
CARATTERISTICHE TECNICHE / TECHNICAL CHARACTERISTICSCodiceCode
TensioneVoltage
(V)
Potenza FrigoriferaCooling Capacity
(Kw)
Portata ariaAir flow(m³/h)
Corrente AssorbitaCurrent Absorption
(A)
PesoWeight
(Kg)
LarghezzaWidth
(L)
TettoRoof(R)
SANTANA LU003FF120E 12
MAX 18 4000
110
90
1600 mm R6000 mmU003FF106E 24 65
SANTANA XLU003FF121E 12 110
1800 mm R10000 mmU003FF107E 24 65
Pressione statica / Static pressure: 0 mmH2O - Tensione alimentazione / Supply voltage: 13 V DC
2150 mm
(L)
mm
NOTE:- Funzionamento in negativo dei comandi
manuali ed elettronici.
NOTE:- Electrical is configured for negative
switching.1A
200 mm (R) mm
4
FC
V
E V
- DESCRIZIONE PRODOTTOIl GRUPPO è composto: dalle unità evaporatore "E", dai ventilatori "V", dai condensatori elettroventilati "C", dalfiltro essiccatore "F", dai relativi tubi preformati di collegamento e dal cablaggio elettrico. Al GRUPPO dovrà es-sere abbinato un diffusore aria, come suggerito nel configuratore di sistema in abbinamento ai comandi proposti,secondo le scelte del cliente.A completamento dell’impianto, sul veicolo dovranno essere acquistati ed installati: il compressore, eventuali sup-porti, la cinghia di traino, la puleggia motore aggiuntiva (se non predisposta sul veicolo), nonchè l’impianto elet-trico, i tubi flessibili e relative valvole di carica (non forniti con il presente prodotto - da richiedere all’ufficioVendite DELPHI-DIAVIA in base al modello di veicolo in esame).
- PRODUCT DESCRIPTION The ASSEMBLY is made up of: the evaporating units "E", fans "V", electrically cooled condensers "C", receiverdrier filter "F", pre-shaped connection hosing and electrical wiring.The ASSEMBLY must be used in combination with an air vent as suggested in the system configurator, combinedwith proposed controls as required by the costomer.To complete the unit, the following must be purchased and installed in the vehicle: compressor, any supports,transmission belt, additional drive pulley (if not arranged on the vehicle) and the electrical wiring, the hoses andcharge valves (not supplied with the present product - to be requested to the DELPHI-DIAVIA Sales officespecifying the vehicle model required).
CARATTERISTICHE TECNICHE / TECHNICAL CHARACTERISTICS2A
C
5
3A
INDICAZIONI PER IL MONTAGGIO SUL TETTO / TEMPLATE FOR ROOF INSTALLATION
AB Bx
Y
Y
A BOCCA ASPIRAZIONE / SUCTION OPENING
B APERTURE MANDATA ARIA / DISCHARGE AIR LOUVERS
C APERTURE IMPIANTO ELETTRICO E TUBI GAS / HOSES AND WIRING OPENINGS
X FORI CONDOTTI SCARICO CONDENSA / CONDENSATE DRAINAGE HOLES
Y PUNTI DI FISSAGGIO / FIXING POINTS
450mm
740m
mx
Y
Y
C C
6
CONFIGURATORE SISTEMA
1B
SYSTEM CONFIGURATOR
Nelle pagine seguenti sono riportate indicazioni generali di configurazioni del sistema per differentiapplicazioni e/o caratteristiche del veicolo.
The following pages give general suggestions of system configuration for different applicationsand/or vehicle characteristics
7
CONFIGURATORE SISTEMA / SYSTEM CONFIGURATOR
2B
HVAC
IMP
IAN
TO
ELE
TTR
ICO
TM21
TM31
ELE
TR
IC W
IRIN
G
COMANDOCONTROL
DISTRIBUZIONE ARIAAIR DISTRIBUTION
GRIGLIA ASPIRAZIONE CON FILTROAIR INLET WITH FILTER
TU
BI G
AS
GA
S H
OS
ES
TUBI GASGAS HOSES
PROLUNGHE ELETTRICHEWIRING EXTENSIONS
RACCORDIFITTINGS
KIT RISCALDAMENTOHEATING KIT
ADATTATORIFLANGE FITTINGS
KIT RICIRCOLO ARIAAIR RECIRCULATION KIT
OPTIONAL
OPTIONAL
8
CONFIGURATORE SISTEMA / SYSTEM CONFIGURATOR
RACCORDI E TUBI GAS / FITTINGS AND GAS HOSES
1C
9
CONFIGURATORE SISTEMA / SYSTEM CONFIGURATOR
RACCORDI E TUBI GAS / FITTINGS AND GAS HOSES
2C
10
RACCORDI COMPRESSORE / COMPRESSOR FITTINGS
Raccordo a Blocchetto Raccordo 45°
Raccordo 90° Raccordo 180° (Diritto)
Block Connection Connection 45°
Connection 90° Connection 180° (Splice)
3C
11
CONFIGURATORE SISTEMA / SYSTEM CONFIGURATOR
KIT RISCALDAMENTO / HEATING KIT (A031085)
1D
OPTIONAL CodiceCode
TensioneVoltage
(V)
Potenza CalorificaHeating Capacity
(Kw)
Kit RiscaldamentoHeating Kit A031085 12 / 24 MAX 18
- Il kit è comprensivo di manicotti econnessioni interne al gruppo.
- E’ sprovvisto dei tubi acqua direttial motore e della pompa acqua.
- In the kit are included water rub-ber hoses and internal water fittin-gs.
- Not included water rubber hosesfrom the R.T.U. to the engine andthe water pump.
12
CONFIGURATORE SISTEMA / SYSTEM CONFIGURATOR
KIT RICIRCOLO ARIA / AIR RECIRCULATION KIT (A031077)
1E
OPTIONAL CodiceCode
TensioneVoltage
(V)
Kit Ricircolo AriaAir Recirculation Kit A031077 12 / 24
NOTE:- Funzionamento in negativo.
NOTE:- Electrical is configured for negative
switching.
13
CONFIGURATORE SISTEMA / SYSTEM CONFIGURATOR
SANTANA XL (C/F + RIC)
1F
NOTE:- Funzionamento in negativo.
NOTE:- Electrical is configured for negative
switching.
CodiceCode
TensioneVoltage
(V)
Potenza FrigoriferaCooling Capacity
(Kw)
Portata ariaAir flow(m³/h)
Corrente AssorbitaCurrent Absorption
(A)
PesoWeight
(Kg)
LarghezzaWidth
(L)
TettoRoof(R)
SANTANA XL U003CF071E 24 MAX 18 4000 65 90 1800 mm R10000 mm
Pressione statica / Static pressure: 0 mmH2O - Tensione alimentazione / Supply voltage: 13 V DC
14
CONFIGURATORE SISTEMA / SYSTEM CONFIGURATOR
COMANDI / CONTROLS
1G
15
CONFIGURATORE SISTEMA / SYSTEM CONFIGURATOR
2G
MANUALEMANUAL
MANUALEMANUAL
MANUALEMANUAL
MANUALEMANUAL
MANUALEMANUAL
AUTOMATICOAUTOMATIC
AC 12V A031068 A031063 A031022 / / A04003
AC 24V A031070 A031066 A031022 / / A04004
HVAC 12V / / / A031002/1 A031003/1 A04014
HVAC 24V / / / A031073 A031072 A04006
Nota:- Per i dettagli dei collegamenti elettrici fare riferimento al manuale di montaggio.
Note:- For the details of the electric connections see the fitting manual.
Ventilazione Riscaldamento AC on/off REC on/offVentilation (Potenziometro + valvola acqua)
Heating(Potentiometer + water valve)
16
CONFIGURATORE SISTEMA / SYSTEM CONFIGURATOR
PROLUNGHE ELETTRICHE1H
ELECTRICAL EXTENSIONLunghezza
LengthSezione Cavi
Section CablesCodiceCode
PROLUNGA DI POTENZA MAXIMAXI POWER EXTENSION 13 m 35 mm2 0282503/0
PROLUNGA DI POTENZA MIDIMIDI POWER EXTENSION
13 m 25 mm2 0282504/0
PROLUNGA DI POTENZA MINIMINI POWER EXTENSION
8 m 16 mm2 0282505/0
PROLUNGA DI SEGNALESIGNAL EXTENSION
13 m 9 X 0,5 mm2 0282506/0
(I)DELPHI ITALIA mira ad un costante miglioramento dei propri prodotti. La Casa si riserva il diritto di apportare in qualunque momento e senza preavvisomodifiche ai modelli e ai componenti descritti in questa pubblicazione per ragioni di natura tecnica o commerciale. Per ulteriori informazioni rivolgersi alservizio assistenza DELPHI.
(GB)DELPHI ITALIA focuses on constant upgrading of its products. The Manufacturer reserves the right to modify the models and components described inthe present publication at any time for technical or commercial reasons and without prior notice. For further information, contact DELPHI technical ser-vices.
MOD. SCHDV237 V / ’10(2010)
SALE AND SERVICEVENDITA E SERVIZIO
Questa pubblicazione è stata curata da DELPHI ITALIA-Diavia
Stabilimento Molinella Via Nobili, 2 40062 Molinella (Bologna)-Italy Telefono (0039) 051.6906111 Fax (0039) 051.6906287
DELPHI ITALIA AUTOMOTIVE SYSTEMS S.r.l.
Ufficio Fitting Instructions - Stabilimento Molinella
This publication has been edited by DELPHI ITALIA-DiaviaFitting Instructions Office - Factory Molinella
E-mail: [email protected]