TABLAS TECNICAS 5
CONDUCTORES HOMOGENEOS DE ALUMINIO NORMA UNE 21.018ALL ALUMINIUM CONDUCTORS ( AAC ) STANDARD UNE 21.018CONDUCTEURS HOMOGENES D´ ALUMINIUM NORME UNE 21.018
DENOMINACIÓNCODE WORDDÉSIGNATION
SECCIÓNSECTIONSECTION
DIÁMETRO EXTERIOROV. DIAMETERDIAMÉTRE EXT.
CALIBRE AUXIMERESISTENCIA ELÉCTRICAELECTRICAL RESISTANCERÉSISTANCE ÉLECTRIQUE
L-28L-40L-56L-80L-110
L-145L-180L-280L-400L-450L-550L-630
27,8
43,154,6
75,5117,0148,1
188,1279,3381,4454,5547,3
638,3
6,458,409,45
11,2514,00
15,7517,7521,7025,3827,7230,4232,85
( mm )2
AUXIME CALIBERCALIBRE AUXIME
( mm ) ( / Km )Ω
101010
10
1515
152025252535
1,02850,66410,52470,38070,24580,19420,15290,10320,07580,06350,05270,0452
CONDUCTORES HOMOGENEOS DE ALUMINIO NORMA BS 215ALL ALUMINIUM CONDUCTORS ( AAC ) STANDARD BS 215CONDUCTEURS HOMOGENES D´ ALUMINIUM NORME BS 215
DENOMINACIÓNCODE WORDDÉSIGNATION
SECCIÓNSECTIONSECTION
DIÁMETRO EXTERIOROV. DIAMETERDIAMÉTRE EXT.
CALIBRE AUXIMERESISTENCIA ELÉCTRICAELECTRICAL RESISTANCERÉSISTANCE ÉLECTRIQUE
( mm )2
AUXIME CALIBERCALIBRE AUXIME
( mm ) ( / Km )ΩMIDGEANTFLYEARWINGWASPBEETLE
HORNETCHAFERCOCKROACHBUTTERFLYCENTIPEDE
22506075100100150200250300400
6,189,3010,2011,3413,1713,35
16,2518,9021,1023,2526,46
1,22700,54190,45050,36440,27020,27040,18250,13490,10830,089160,06944
1010101010101520
202025
255
TABLAS TECNICAS 6
CONDUCTORES HOMOGENEOS DE ALUMINIO NORMA ASTM B-231ALL ALUMINIUM CONDUCTORS ( AAC ) STANDARD ASTM B-231CONDUCTEURS HOMOGENES D´ ALUMINIUM NORME ASTM B-231
DENOMINACIÓNCODE WORDDÉSIGNATION
SECCIÓNSECTIONSECTION
DIÁMETRO EXTERIOROV. DIAMETERDIAMÉTRE EXT.
CALIBRE AUXIMERESISTENCIA ELÉCTRICAELECTRICAL RESISTANCERÉSISTANCE ÉLECTRIQUE
( mm )2
AUXIME CALIBERCALIBRE AUXIME
( mm ) ( / Km )ΩPEACHBELLROSE
IRISPANSYPOPPYASTERPHLOXOXLIPSNEEZEWORTHVALERIANDAISYLAURELPEONYTULIPDAFFODILCANNAGOLDENTUFT
COSMOSSYRINGAZINNIAHYACINTHDAHLIAMISTLETOEMEADOWSWEETORCHIDHEUCHERAVERBENAFLAGVIOLETNASTURTIUMPETUNIACATTAILARBUTUSLILAC
13,2121,1233,5442,4953,5267,3484,91107,4127,6126,4135,3135,2151,9170,5177,6202,1228,1241,2241,0253,3252,9282,4281,1303,2322,2330,0354,0354,5362,1362,3380,8381,0402,1402,9
FUCHSIA 408,7
4,655,887,418,349,3610,5011,7913,2614,4014,5514,8815,0515,9516,9017,2518,40
19,5520,1020,1620,6020,6521,75
21,7722,6123,31
23,5924,4324,4824,7124,75
25,3425,3826,0426,1026,25
20ºC2,17021,36380,85700,68010,53900,42750,33920,26890,22730,22730,21330,21330,18970,16910,16260,14310,12640,11930,11930,11380,11380,10220,10220,094820,089470,087470,081230,081230,079530,079530,075850,075850,071560,071560,07116
101010
101010
1010
1515151515151515
202020202020202020202020
2525
2525252525
256
TABLAS TECNICAS 7
CONDUCTORES HOMOGENEOS DE ALUMINIO NORMA ASTM B-231ALL ALUMINIUM CONDUCTORS ( AAC ) STANDARD ASTM B-231CONDUCTEURS HOMOGENES D´ ALUMINIUM NORME ASTM B-231
DENOMINACIÓNCODE WORDDÉSIGNATION
SECCIÓNSECTIONSECTION
DIÁMETRO EXTERIOROV. DIAMETERDIAMÉTRE EXT.
CALIBRE AUXIMERESISTENCIA ELÉCTRICAELECTRICAL RESISTANCERÉSISTANCE ÉLECTRIQUE
2
AUXIME CALIBERCALIBRE AUXIME
( mm ) ( / Km )Ω20ºCHELIOTROPE
( mm )408,5 26,28 0,07116
ANEMONECROCUS
COCKCOMBSNAPDRAGONMAGNOLIAGOLDENRODHAWKWEEDCAMELLIABLUEBELLLARKSPURMARIGOLDHAWTHORNNARCISSUSCOLUMBINECARNATIONGLADIOLUSCOREOPSISJESSAMINE
444,3442,8455,7457,4483,7484,5505,3506,0522,4524,9563,6603,8645,,3684,5725,0766,5805,4885,8
27,3727,3627,7227,8128,5628,6229,1929,2529,6829,7930,8731,9533,0334,0235,0136,0036,9038,70
0,065060,065060,063320,063320,59650,059650,056890,056890,055050,05505
0,051120,047700,044720,042090,039760,037660,035790,03251
25
25
2525252525
25252525
35
3535353535
4040
257
TABLAS TECNICAS 8
CONDUCTORES DE ALEACION DE ALUMINIO NORMA UNE 21.018 TABLA 3ALUMINIUM ALLOY CONDUCTORS ( AA.A.) STANDARD UNE 21.018CONDUCTEURS D´ALLIAGE D´ ALUMINIUM NORME UNE 21.018
DENOMINACIÓNCODE WORDDÉSIGNATION
SECCIÓNSECTIONSECTION
DIÁMETRO EXTERIOROV. DIAMETERDIAMÉTRE EXT.
CALIBRE AUXIMERESISTENCIA ELÉCTRICAELECTRICAL RESISTANCERÉSISTANCE ÉLECTRIQUE
( mm )2
AUXIME CALIBERCALIBRE AUXIME
( mm ) ( / Km )Ω20ºCD-28D-40D-56D-60D-110D-145D-180D-280D-400D-450D-550D-630
27,843,154,675,5117,0148,1188,1279,3381,4454,5547,3638,3
6,758,409,4511,2514,0015,7517,7521,7025,3827,7230,4232,85
1,18270,76370,60340,43780,28270,22340,17580,11870,08720,07310,0607
0,0520
1015
1515
20
25252535
101010
CONDUCTORES DE ALEACION DE ALUMINIO NORMA BS-3242 TABLA 3ALUMINIUM ALLOY CONDUCTORS ( AA.A.C.) STANDARD BS-3242CONDUCTEURS D´ALLIAGE D´ ALUMINIUM NORME BS-3242
DENOMINACIÓNCODE WORDDÉSIGNATION
SECCIÓNSECTIONSECTION
DIÁMETRO EXTERIOROV. DIAMETERDIAMÉTRE EXT.
CALIBRE AUXIMERESISTENCIA ELÉCTRICAELECTRICAL RESISTANCERÉSISTANCE ÉLECTRIQUE
2
AUXIME CALIBERCALIBRE AUXIME
( mm ) ( / Km )Ω20ºC( mm )ALMONDCEDARPIR
HAZELOAKASHELMUPAS
30,1035,4747,8459,87118,9180,7211,0362,10
7,027,628,859,9013,9517,40
18,8024,71
1,09400,92810,6880
0,54980,27690,18300,15680,0915
1010101015152025
258
TABLAS TECNICAS 9
CONDUCTORES DE ALEACION DE ALUMINIO NORMA NF-C 34125ALUMINIUM ALLOY CONDUCTORS ( AA.A.C.) STANDARD NF-C 34125CONDUCTEURS D´ALLIAGE D´ ALUMINIUM NORME NF-C 34125
DENOMINACIÓNCODE WORDDÉSIGNATION
SECCIÓNSECTIONSECTION
DIÁMETRO EXTERIOROV. DIAMETERDIAMÉTRE EXT.
CALIBRE AUXIMERESISTENCIA ELÉCTRICAELECTRICAL RESISTANCERÉSISTANCE ÉLECTRIQUE
2
AUXIME CALIBERCALIBRE AUXIME
( mm ) ( / Km )Ω20ºC( mm )ASTER 34,4
ASTER 54,6ASTER 75,5ASTER 117ASTER 148ASTER 181,6ASTER 228ASTER 288ASTER 366ASTER 570
34,36
54,5575,54116,98148,01181,62227,83288,34366,22570,22
7,509,4511,2514,0015,7517,5019,6022,0524,8531,05
0,9580,6030,4380,2830,2240,1830,1460,115
0,0905
0,0583
101010
10
151515
20202540
CONDUCTORES DE ALEACION DE ALUMINIO NORMA ASTM B-399ALUMINIUM ALLOY CONDUCTORS ( AA.A.C.) STANDARD ASTN B-399CONDUCTEURS D´ALLIAGE D´ ALUMINIUM NORME ASTM B-399
DENOMINACIÓNCODE WORDDÉSIGNATION
SECCIÓNSECTIONSECTION
DIÁMETRO EXTERIOROV. DIAMETERDIAMÉTRE EXT.
CALIBRE AUXIMERESISTENCIA ELÉCTRICAELECTRICAL RESISTANCERÉSISTANCE ÉLECTRIQUE
2
AUXIME CALIBERCALIBRE AUXIME
( mm ) ( / Km )Ω20ºC( mm )AKRONALTONAMESAZUSA
ANAHEIMAMHERSTALLIANCEBUTTECANTONCAIRODARIENELGINFLINT
GREELEY
15,5224,70
39,1962,4478,5599,30125,09158,59199,89236,38283,67331,04374,52469,62
5,046,368,0110,1111,34
12,7514,3116,3018,3019,9021,8023,5525,1328,14
2,16141,35760,85330,53640,42550,33790,26580,21140,16750,14210,1181
0,10130,089240,07129
1010
10
101010
15151520
20
20
2525
ASTER 851 850,66 37,95 0,0391ASTER 1144 1143,51 44,00 0,0292 45
259
TABLAS TECNICAS 10
CONDUCTORES DE ALEACION DE ALUMINIO CON ALMA DE ACERO NORMA UNE 21.018 TABLA 4ALUMINIUM ALLOY CONDUCTORS STEEL REINFORCED STANDARD UNE 21.018CONDUCTEURS D´ALLIAGE D´ ALUMINIUM AVEC AME D´ACIER NORME UNE 21.018
DENOMINACIÓNCODE WORDDÉSIGNATION
SECCIÓNSECTIONSECTION
DIÁMETRO EXTERIOROV. DIAMETERDIAMÉTRE EXT.
CALIBRE AUXIMERESISTENCIA ELÉCTRICAELECTRICAL RESISTANCERÉSISTANCE ÉLECTRIQUE
2
AUXIME CALIBERCALIBRE AUXIME
( mm ) ( / Km )Ω20ºC( mm )
151010
10
201515
DA-30DA-56DA-78DA-110DA-145DA-180DA-280
31,154,678,6
116,2147,1181,6279,3
7,149,4511,3414,0015,7517,5021,70
1,32600,70560,49000,35250,27850,22560,1467
CONDUCTORES DE ALEACION DE ALUMINIO CON ALMA DE ACERO NORMA NFC-34125 TABLA AALUMINIUM ALLOY CONDUCTORS STEEL REINFORCED STANDARD NFC-34125CONDUCTEURS D´ALLIAGE D´ ALUMINIUM AVEC AME D´ACIER NORME NFC-34125
DENOMINACIÓNCODE WORDDÉSIGNATION
SECCIÓNSECTIONSECTION
DIÁMETRO EXTERIOROV. DIAMETERDIAMÉTRE EXT.
CALIBRE AUXIMERESISTENCIA ELÉCTRICAELECTRICAL RESISTANCERÉSISTANCE ÉLECTRIQUE
2
AUXIME CALIBERCALIBRE AUXIME
( mm ) ( / Km )Ω20ºC( mm )
151010
10
20
1515
PHLOX 37,7PHLOX 59,7PHLOX 75,5
PHLOX 116,2PHLOX 147,1PASTEL 147,1PHLOX 181,6PASTEL 181,6PHLOX 288
PHLOX 228PASTEL 228
PASTEL 288PASTEL 299
37,6959,6975,54116,24147,11147,11181,63181,62227,82227,82288,35288,35299,44
8,310,011,2514,015,7515,7517,517,519,619,6
22,0522,0522,5
1,1700,8800,6950,5800,4660,2790,3780,2270,300
0,1800,2370,1420,162
151520
202020
PHLOX 94,1 94,07 12,8 0,642 10PASTEL 411,67PETUNIA 612 611,89
26,4
32,20,103 25
0,0651 35
260
TABLAS TECNICAS 11
CONDUCTORES DE ALUMINIO - ACERO (L.A.) NORMA UNE 21.018ALUMINIUM CONDUCTORS STEEL REINFORCED (A.C.S.R.) STANDARD UNE 21.018CONDUCTEURS D´ ALUMINIUM - D´ACIER NORME UNE 21.018
DENOMINACIÓNCODE WORDDÉSIGNATION
SECCIÓNSECTIONSECTION
DIÁMETRO EXTERIOROV. DIAMETERDIAMÉTRE EXT.
CALIBRE AUXIMERESISTENCIA ELÉCTRICAELECTRICAL RESISTANCERÉSISTANCE ÉLECTRIQUE
2
AUXIME CALIBERCALIBRE AUXIME
( mm ) ( / Km )Ω20ºC( mm )
151010
10
201515
CONDUCTORES DE ALUMINIO - ACERO AWG-MCM A NORMA ASTM B-232ALUMINIUM CONDUCTORS STEEL REINFORCED AWG-MCM STANDARD ASTM B-232CONDUCTEURS D´ ALUMINIUM - ACIER AWG-MCM NORME ASTM B-232
DENOMINACIÓNCODE WORDDÉSIGNATION
SECCIÓNSECTIONSECTION
DIÁMETRO EXTERIOROV. DIAMETERDIAMÉTRE EXT.
CALIBRE AUXIMERESISTENCIA ELÉCTRICAELECTRICAL RESISTANCERÉSISTANCE ÉLECTRIQUE
2
AUXIME CALIBERCALIBRE AUXIME
( mm ) ( / Km )Ω20ºC( mm )
LA-30LA-56LA-78LA-110LA-145LA-180LA-280LA-380LA-455LA-545
LA-635RAIL
31,154,678,6116,2147,1181,6281,1381,0454,5547,3636,6517,3
7,149,4511,3414,0015,7517,5021,8025,3827,7230,4232,8529,61
1,07490,61360,42610,30660,24220,19620,11940,08570,07180,0596
0,05110,0594
2525253525
GROUSEPETRELMINORCALEGHORNGUINEA
DOTTERELDORKINGBRAHMACOCHIN
54,6681,7188,84108,00
127,23
141,56152,81194,57169,47
9,3211,7012,2013,4514,6015,4016,0018,1216,95
0,6798
0,52170,47930,39470,33400,30020,27820,25200,2513
101010101515151515
261
TABLAS TECNICAS 12
CONDUCTORES DE ALUMINIO - ACERO NORMA BS-215ALUMINIUM CONDUCTORS STEEL REINFORCED (A.C.S.R.) STANDARD BS-215CONDUCTEURS D´ ALUMINIUM - D´ACIER NORME BS-215
DENOMINACIÓNCODE WORDDÉSIGNATION
SECCIÓNSECTIONSECTION
DIÁMETRO EXTERIOROV. DIAMETERDIAMÉTRE EXT.
CALIBRE AUXIMERESISTENCIA ELÉCTRICAELECTRICAL RESISTANCERÉSISTANCE ÉLECTRIQUE
2
AUXIME CALIBERCALIBRE AUXIME
( mm ) ( / Km )Ω20ºC( mm )
101010
10
151510
CONDUCTORES DE ALUMINIO - ACERO AWG-MCM NORMA IEC 1089ALUMINIUM CONDUCTORS STEEL REINFORCED AWG-MCM (ACSR) STANDARD IEC 1089CONDUCTEURS D´ ALUMINIUM - ACIER AWG-MCM NORME IEC 1089
DENOMINACIÓNCODE WORDDÉSIGNATION
SECCIÓNSECTIONSECTION
DIÁMETRO EXTERIOROV. DIAMETERDIAMÉTRE EXT.
CALIBRE AUXIMERESISTENCIA ELÉCTRICAELECTRICAL RESISTANCERÉSISTANCE ÉLECTRIQUE
2
AUXIME CALIBERCALIBRE AUXIME
( mm ) ( / Km )Ω20ºC( mm )
15151520
GOPHERWEASELFERRETRABBITBEAVERHORSEDOG
TIGERWOLFDINGOLYNX
CARACALPANTHER
JAGUARBEARZEBRAMOOSE
30,6236,88
49,4861,7097,5
116,20118,5161,7194,9167,5
194,5261,5222,3326,1484,5597,0
7,087,779,0010,0511,9713,9514,1516,5218,1316,75
19,5318,0521,0019,3023,4528,6231,77
226,2
1,09300,90770,67660,54260,38250,39360,27330,22020,18280,18150,15760,15630,13630,13670,10430,06740,0548
1520202025
35
ZAMBEZEZIGOLO
595,0222,4
31,819,4
0,05110,1510
3520
262
TABLAS TECNICAS 13
CONDUCTORES DE ALUMINIO - ACERO NORMA NF-C 34120ALUMINIUM CONDUCTORS STEEL REINFORCED STANDARD NF-C 34120CONDUCTEURS D´ ALUMINIUM - ACIER NORME NF-C 34120
DENOMINACIÓNCODE WORDDÉSIGNATION
SECCIÓNSECTIONSECTION
DIÁMETRO EXTERIOROV. DIAMETERDIAMÉTRE EXT.
CALIBRE AUXIMERESISTENCIA ELÉCTRICAELECTRICAL RESISTANCERÉSISTANCE ÉLECTRIQUE
2
AUXIME CALIBERCALIBRE AUXIME
( mm ) ( / Km )Ω20ºC( mm )
151010
10
151515
1515202020
CANNA 37,7CANNA 59,7CANNA 75,5CANNA 116,2CROCUS 116,12CANNA 147,1CROCUS 147,1CANNA 181,6CROCUS 181,6CANNA 228CROCUS228CANNA 288CROCUS 288CROCUS 297CROCUS 412
37,6959,6975,54116,24116,24147,11147,11181,62181,62227,82227,82288,35288,35297,21411,67
8,3010,0011,2514,0014,0015,7515,7517,5017,5019,6019,6022,0522,0522,4526,40
CROCUS 612 611,76 32,20 0,05660,04050,0303
CROCUS 865 865,39 38,10CROCUS 1185 1184,48 44,70
1,0200,7660,6050,3060,3060,2430,2430,1970,1970,1570,1570,1240,1240,13050,0898
4540
35252020
CONDUCTORES DE LUMINIO COMPACTADO - ACERO NORMA UNE 21.018COMPACT-ROUNDALUMINIUM CONDUCTORS STEEL REINFORCED STANDARD UNE 21.018CONDUCTEURS D´ ALUMINIUM COMPACTE- ACIER NORME UNE 21.018
DENOMINACIÓNCODE WORDDÉSIGNATION
SECCIÓNSECTIONSECTION
DIÁMETRO EXTERIOROV. DIAMETERDIAMÉTRE EXT.
CALIBRE AUXIMERESISTENCIA ELÉCTRICAELECTRICAL RESISTANCERÉSISTANCE ÉLECTRIQUE
2
AUXIME CALIBERCALIBRE AUXIME
( mm ) ( / Km )Ω20ºC( mm )LAC - 40
LAC - 56LAC - 80
44,8378,6499,22
7,8210,4111,68
0,85070,42450,3367
101010
263
TABLAS TECNICAS 14
CONDUCTORES DE ALUMINIO - ACERO AWG-MCM NORMA ASTM B-232ALUMINIUM CONDUCTORS STEEL REINFORCED AWG-MCM ( A.C.S.R. ) STANDARD ASTM B-232CONDUCTEURS D´ ALUMINIUM - ACIER AWG-MCM NORME ASTM B-232
DENOMINACIÓNCODE WORDDÉSIGNATION
SECCIÓNSECTIONSECTION
DIÁMETRO EXTERIOROV. DIAMETERDIAMÉTRE EXT.
CALIBRE AUXIMERESISTENCIA ELÉCTRICAELECTRICAL RESISTANCERÉSISTANCE ÉLECTRIQUE
2
AUXIME CALIBERCALIBRE AUXIME
( mm ) ( / Km )Ω20ºC( mm )
TURKEYSWAN
SWANATESPARROWSPARATEROBINRAVENQUAILPIGEONPENGUINWAXWINGPARTRIDGEOSTRICHMERLINLINNETORIOLE
CHICKADEEBRANTIBISLARK
PELICANFLICKERHAWKHEN
OSPREYPARAKEET
DOVEEAGLE
PEACOCKSQUAB
WOODDUCKTEAL
KINGBIRDROOK
GROSBEAKSCOTEREGRETSWIFT
FLAMINGOGANNETSTILT
15,5224,7126,4739,2042,0949,4862,4478,5699,31
125,09142,5156,9176,9179,7198,4210,3212,1
227,7234,0247,8255,8273,0280,8297,6298,2318,9328,5347,9345,9355,6378,7376,7340,9365,0374,3397,9396,1332,0381,0393,2410,2
5,046,366,538,018,249,0
10,1111,3412,7514,3115,4516,2817,2817,3518,3118,8318,8519,6219,8820,4420,7021,4921,7722,4022,3523,2223,5524,2724,1924,5125,2725,2423,9024,8425,1525,9025,9023,6625,3825,7626,32
2,11351,32781,3133
0,83430,82510,66210,52430,41600,33040,26180,21190,21000,18670,16800,16630,16540,14210,14170,14110,14010,1184011780,11710,11650,10140,10100,10070,1001
0,092850,092520,091860,091860,088910,088250,087930,087600,087600,089240,084320,083990,07841
1010101010101010101515151515152020202020202020202020202020252525202525252520252525
264
TABLAS TECNICAS 15
CONDUCTORES DE ALUMINIO - ACERO AWG-MCM NORMA ASTM B-232ALUMINIUM CONDUCTORS STEEL REINFORCED AWG-MCM ( A.C.S.R. ) STANDARD ASTM B-232CONDUCTEURS D´ ALUMINIUM - ACIER AWG-MCM NORME ASTM B-232
DENOMINACIÓNCODE WORDDÉSIGNATION
SECCIÓNSECTIONSECTION
DIÁMETRO EXTERIOROV. DIAMETERDIAMÉTRE EXT.
CALIBRE AUXIMERESISTENCIA ELÉCTRICAELECTRICAL RESISTANCERÉSISTANCE ÉLECTRIQUE
2
AUXIME CALIBERCALIBRE AUXIME
( mm ) ( / Km )Ω20ºC( mm )
STARLINGREDWINGCUCKOODRAKECOOTTERN
CONDORMALLARDRUDDYCANARYCATBIRD
RAILCARDINALTANAGERORTOLANCURLEWBLUEJAYFINCH
BUNTINGGRACKLESKYLARKBITTERN
PHEASANTDIPPERMARTIN
BOBOLINKPLOVER
NUTHATCHPARROTLAPWINGFALCONCHUKARBLUEBIRD
KIWITHRASHER
421,0444,5454,5468,0413,1431,6454,5495,6487,2515,4498,1517,3547,3537,3560,2593,6604,4636,6647,7679,7554,0689,1726,8731,4772,1775,4818,7817,0863,1863,1908,6976,71181,61147,31235,3
26,6827,4327,7228,1126,3927,0327,7228,9628,7429,5228,9829,6130,4230,1030,8131,6831,9832,8533,1233,9733,4634,1735,1035,1936,1736,2437,2437,2038,2538,2239,2642,7044,7644,1045,79
0,078080,077760,070870,070540,071520,071190,070540,069880,062340,062340,059710,059380,059060,055770,054790,054460,050850,050850,047570,047240,044620,044620,044290,041990,041670,039700,039370,037400,037400,035760,035430,031820,026280,026280,02461
2525252525252525252525252525353535353535353535353535404040404045454545
265
TABLAS TECNICAS 16
CONDUCTORES DE ALUMINIO - ACERO RECUBIERTO DE ALUMINIO ( LARL ) NORMA UNE 21.058ALUMINIUM CONDUCTORS ALU-CLAD STEEL REINFORCED ( A.C.S.R./AW) STANDARD UNE 21.058CONDUCTEURS D´ ALUMINIUM - ACIER RECOUVERT D´ALUMINIUM NORME UNE 21.058
DENOMINACIÓNCODE WORDDÉSIGNATION
SECCIÓNSECTIONSECTION
DIÁMETRO EXTERIOROV. DIAMETERDIAMÉTRE EXT.
CALIBRE AUXIMERESISTENCIA ELÉCTRICAELECTRICAL RESISTANCERÉSISTANCE ÉLECTRIQUE
2
AUXIME CALIBERCALIBRE AUXIME
( mm ) ( / Km )Ω20ºC( mm )
LARL 30LARL 56LARL 78LARL 125 (PENGUIN)LARL 180LARL 280 (HAWK)LARL 380(GULL)LARL 455 (CONDOR)LARL 510 (RAIL)LARL 545 (CARDINAL)LARL 600 (BLUEJAY)LARL 820 (PLOVER)
31,154,678,6125,1181,6281,1381,0454,5516,8547,3603,0817,0
7,149,4511,3414,3117,5021,8025,3827,7229,5930,4231,9637,21
1,01750,58080,40330,25680,18180,1131
0,08200,06880,05850,05710,05020,0385
101010151520252525253540
CONDUCTORES DE LUMINIO - ACERO RECUBIERTO DE ALUMINIO ( LARL ) NORMA ASTM B-549ALUMINIUM CONDUCTORS ALU-CLAD STEEL REINFORCED ( A.C.S.R./AW) STANDARD ASTM B-549CONDUCTEURS D´ ALUMINIUM - ACIER RECOUVERT D´ALUMINIUM NORME ASTM B-549
DENOMINACIÓNCODE WORDDÉSIGNATION
SECCIÓNSECTIONSECTION
DIÁMETRO EXTERIOROV. DIAMETERDIAMÉTRE EXT.
CALIBRE AUXIMERESISTENCIA ELÉCTRICAELECTRICAL RESISTANCERÉSISTANCE ÉLECTRIQUE
2
AUXIME CALIBERCALIBRE AUXIME
( mm ) ( / Km )Ω20ºC( mm )SWAN/AWSWANATE/AWSPARROW/AWSPARATE/AWROBIN/AWRAVEN/AWQUAIL/AWPIGEON/AWPENGUIN/AWWAXWING/AWPARTRIDGE/AWMERLIN/AWLINNET/AW
24,6726,5039,8042,2049,5662,4678,7899,17125,1142,6157,2179,9198,4
6,356,538,038,269,0210,1111,3512,7514,3015,4716,3117,3718,31
1,2851,251
0,80780,78610,63980,50760,40120,31980,25350,20880,20240,16550,1607
10101010101010101515151515
266
TABLAS TECNICAS 17
CONDUCTORES DE ALUMINIO - ACERO RECUBIERTO DE ALUMINIO ( LARL ) NORMA ASTM B-549ALUMINIUM CONDUCTORS ALU-CLAD STEEL REINFORCED ( A.C.S.R./AW) STANDARD ASTM B-549CONDUCTEURS D´ ALUMINIUM - ACIER RECOUVERT D´ALUMINIUM NORME ASTM B-549
DENOMINACIÓNCODE WORDDÉSIGNATION
SECCIÓNSECTIONSECTION
DIÁMETRO EXTERIOROV. DIAMETERDIAMÉTRE EXT.
CALIBRE AUXIMERESISTENCIA ELÉCTRICAELECTRICAL RESISTANCERÉSISTANCE ÉLECTRIQUE
2
AUXIME CALIBERCALIBRE AUXIME
( mm ) ( / Km )Ω20ºC( mm )
ORIOLE/AWCHICKADEE/AWBRANT/AWIBIS/AWLARK/AWPELICAN/AWFLICKER/AWHAWK/AWHEN/AWOSPREY/AWPARAKEET/AWDOVE/AWEAGLE/AWPEACOCK/AWSQUAB/AWTEAL/AWKINGBIRD/AWROOK/AWGROSBEAK/AWEGRET/AWFLAMINGO/AWGANNET/AWSTARLING/AWREDWING/AWTERN/AWCUCKOO/AWCONDOR/AWDRAKE/AWMALLARD/AWRUDDY/AWCANARY/AWRAIL/AWCARDINAL/AWORTOLAN/AWCURLEW/AWBLUEJAY/AWFINCH/AWBUNTING/AWGRACKLE/AW
210,3212,6227,6234,0248,4255,2273,1281,3298,1297,6318,7328,0347,8346,5356,3376,4340,3364,1374,7395,8381,8392,7421,6445,0430,6455,1455,6468,6494,8487,4515,2516,9546,0560,4692,1603,3635,8645,8680,7
18,8218,8719,6119,8920,4720,6821,4321,7922,4322,3323,2223,5524,2124,2124,5425,2523,8824,8225,1525,8824,4025,7626,7027,4627,0027,7427,7628,1428,9628,7329,5129,5930,3830,8131,6531,9832,8433,0733,86
0,15730,14000,13730,13600,13320,11670,11440,11330,11100,1001
0,098070,097030,095120,090190,090970,087670,087500,085830,084910,083370,081860,081040,075460,074150,070050,068670,068610,067920,066700,061880,060670,058370,057220,053840,052790,052690,049310,046690,04603
202020202020202020202020202020252525252525252525252525252525252525353535353535
267
TABLAS TECNICAS 18
CONDUCTORES DE ALUMINIO - ACERO RECUBIERTO DE ALUMINIO ( LARL ) NORMA ASTM B-549ALUMINIUM CONDUCTORS ALU-CLAD STEEL REINFORCED ( A.C.S.R./AW) STANDARD ASTM B-549CONDUCTEURS D´ ALUMINIUM - ACIER RECOUVERT D´ALUMINIUM NORME ASTM B-549
DENOMINACIÓNCODE WORDDÉSIGNATION
SECCIÓNSECTIONSECTION
DIÁMETRO EXTERIOROV. DIAMETERDIAMÉTRE EXT.
CALIBRE AUXIMERESISTENCIA ELÉCTRICAELECTRICAL RESISTANCERÉSISTANCE ÉLECTRIQUE
2
AUXIME CALIBERCALIBRE AUXIME
( mm ) ( / Km )Ω20ºC( mm )
BITTERN/AWPHEASANT/AWDIPPER/AWMARTIN/AW
BOBOLINK/AWPLOVER/AW
NUTHATCH/AWPARROT/AWLAPWING/AWFALCON/AW
689,1726,5731,7771,7774,9817,5818,1864,6860,1907,8
34,1635,1035,2036,1736,2537,2137,2438,2538,1539,24
0,043800,043150,041210,040620,038910,038350,036880,036260,035070,03452
35353535354040404040
268
TABLAS TECNICAS 19
CONDUCTORES DE COBRE PARA LINEAS ELÉCTRICAS AÉREAS NORMA UNE 21.012 1° R.COPPER STRANDS STANDARD UNE 21.021 1° R.CONDUCTEURS DE CUIVRE POUR LIGNES DE DISTRIBUTION D´ ÉNERGIE NORME UNE 21.012 1° R.
DENOMINACIÓNCODE WORDDÉSIGNATION
SECCIÓNSECTIONSECTION
DIÁMETRO EXTERIOROV. DIAMETERDIAMÉTRE EXT.
CALIBRE AUXIMERESISTENCIA ELÉCTRICAELECTRICAL RESISTANCERÉSISTANCE ÉLECTRIQUE
2
AUXIME CALIBERCALIBRE AUXIME
( mm ) ( / Km )Ω20ºC( mm )C 10C 16C 25C 35C 50C 70C 95C 120C 150C 185C 235C 300C 400
10,015,925,234,950,070,394,8121,2147,1184,5236,0304,2389,1
4,055,106,427,569,1510,8512,6014,2515,7517,6419,6522,6825,65
1,841,16
0,7340,5290,3720,2640,1960,1530,1260,101
0,07890,06150,0480
10101010101010151515202025
PLETINAS DE COBRECOPPER PLATEEPLAGE EN CUIVRE
DENOMINACIÓNCODE WORDDÉSIGNATION
SECCIÓNSECTIONSECTION
2( mm )
BARRAS DE COBRECOPPER BARTIGE EN CUIVRE
SECCIÓNSECTIONSECTION
2( mm )
Ø
( mm )
PESOWEIGHTPOIDS
PESOWEIGHTPOIDS
( Kg )( Kg )25 x 530 x 330 x 530 x 1040 x 340 x 540 x 1050 x 550 x 1060 x 560 x 1080 x 580 x 10100 x 5100 x 10
124,089,5149299119199399249499299599399799499999
1,110,7961,332,661,061,773,552,224,442,665,333,557,114,448,89
810121416
50,378,5113,0153,9201,0
0,4470,699
11,3981,79
269
TABLAS TECNICAS 20
10 20 30 4050 100 150 200 250 3001000
1200
1400
1600
1800
2000
3000
4000
5000
6000
7000
e = 4 mm
e = 6 mm
e = 8 mm
e = 9 mm
e = 10 mm
TUBOS DE ALUMINIO ( ) / TUBOS DE COBRE ( )
Ø TUBO ( mm )
INTE
NSID
AD (
A )
e = 6 mme = 8 mm
e= 10 mm
ALUMINIUM TUBES COPPER TUBESTUBES ALUMINIUM TUBES CUIVRE
270
TABLAS TECNICAS 21
15 16 17 18 19 20 25 30 35 40 45400
450
500
550
600
2000
1800
1600
1400
1200
1000
800
INTE
NSID
AD (
A )
Ø CABLE ( mm )2
CABLES DE ALUMINIO ( ) / CABLES DE COBRE ( )ALUMINIUM CABLES COPPER CABLESCABLES ALUMINIUM CABLES CUIVRE
ALEACION DE ALUMINIO
ALUMINIO - ACERO
COBRE
271
1
2
3
4
5
6/7
9
10
11
12
13
14/15
TABLAS
TABLES
TABLEAUX
PÀGINA
PAGE
PAGE
INDICE - TABLAS TECNICASINDEX - TECHNICAL TABLESINDEX - TABLEAUX TECHNIQUES
DATOS COMPARATIVOS ENTRE EL COBRE Y EL ALUMINIO
TUBOS EN ALEACIÓN DE ALUMINIO ALU ALLOY TUBE TUBE EN ALLIAGE D´ ALUMINIUM TUBO I P S ( Al ) STANDARD I P S TUBE TUBE I P S AMERICAIN TUBO DE COBRE COPPER TUBE TUBE CUIVRE CONDUCTORES HOMOGENEOS DE ALUMINIO NORMA UNE 21.018 ALL ALUMINIUM CONDUCTORS (AAC ) STANDARD UNE 21.018 CONDUCTEURS HOMOGENES D´ALUMINIUM NORME UNE 21.018 CONDUCTORES HOMOGENEOS DE ALUMINIO NORMA ASTM B-231 ALL ALUMINIUM CONDUCTORS ( AAC ) STANDARD ASTM B-231 CONDUCTEURS HOMOGENES D´ALUMINIUM NORME ASTM B-231 CONDUCTORES DE ALEACIÓN DE ALUMINIO NORMA UNE 21.018 TABLA 3 ALUMINIUM ALLOY CONDUCTORS ( AA.A. ) STANDARD UNE 21.018 CONDUCTEURS D´ALLIAGE D´ALUMINIUM NORME UNE 21.0188 CONDUCTORES DE ALEACIÓN DE ALUMINIO NORMA BS-3242 TABLA 3 ALUMINIUM ALLOY CONDUCTORS ( AA.A.C. ) STANDARD BS-3242 CONDUCTEURS D´ALLIAGE D´ALUMINIUM NORME BS-3242 CONDUCTORES DE ALEACIÓN DE ALUMINIO NORMA NF-C 34125 / ASTM B-399 ALUMINIUM ALLOY CONDUCTORS ( AA.A.C.) STANDARD NF-C 34125 / ASTM B-399 CONDUCTEURS D´ALLIAGE D´ALUMINIUM NORME NF-C 34125 / ASTM B-399 CONDUCTORES DE ALEACIÓN DE Al CON ALMA DE ACERO N. UNE 21.018/ NFC-34125 ALUMINIUM ALLOY CONDUCTORS STEEL REINFORCED STANDARD UNE 21.018 / NFC-34125 CONDUCTEURS D´ALLIAGE D´Al AVEC AME D´ACIER NORME UNE 21.018 / NFC-34125 CONDUCTORES DE ALUMINIO - ACERO ( L.A. ) NORMA UNE 21.018 ALUMINIUM CONDUCTORS STEEL REINFORCED ( A.C.S.R. ) STANDARD UNE21.18 CONDUCTEURS D´ALUMINIUM - D´ACIER NORME UNE 21.018 CONDUCTORES DE ALUMINIO - ACERO AWG-MCM A NORMA ASTM B-232 ALUMINIUM CONDUCTORS STEEL REINFORCED AWG-MCM ASTM B-232 CONDUCTEURS D´ALUMINIUM - D´ACIER AWG-MCM NORME ASTM B-232
CONDUCTORES DE ALUMINIO - ACERO NORMA BS-215 / AWG-MCM NORMA IEC 1089 ALUMINIUM CONDUCTORS STEEL REINFORCED ( A.C.S.R. ) STANDARD BS-215 / IEC 1089 CONDUCTEURS D´ALUMINIUM - D´ACIER NORME BS-215 / AWG-MCM NORME IEC 1089 CONDUCTORES DE ALUMINIO - ACERO NORMA NF-C 34120 ALUMINIUM CONDUCTORS STEEL REINFORCED STANDARD NF-C 34120 CONDUCTEURS D´ALUMINIUM - D´ACIER NORME NF-C 34120 CONDUCTORES DE ALUMINIO COMPACTADO - ACERO NORMA UNE 21.018
CONDUCTEURS D´ALUMINIUM COMPACTE - ACIER NORME UNE 21.018 COMPACT- ROUND ALUMINIUM CONDUCTORS STEEL REINFORCED STANDARD UNE 21.018
CONDUCTORES DE ALUMINIO - ACERO AWG-MCM NORMA ASTM B-232
CONDUCTEURS D´ALUMINIUM - ACIER AWG-MCM NORME ASTM B-232 ALUMINIUM CONDUCTORS STEEL REINFORCED AWG-MCM ( A.C.S.R ) STANDARD ASTM B-232
251
252
253
254
255
256257
258
258
259
260
261
261
262
263
263
264265
COMPARATIVE DATA FROM COPPER AND ALUMINIUM LES DONNÉES COMPARATIVES DE CUIVRE ET ALUMINIUM
19
20
21
TABLAS
TABLES
TABLEAUX
PÀGINA
PAGE
PAGE
INDICE - TABLAS TECNICASINDEX - TECHNICAL TABLESINDEX - TABLEAUX TECHNIQUES
CONDUCTORES DE Al - ACERO RECUBIERTO DE Al ( LARL ) NORMA UNE 21.058 ALU CONDUCTORS ALU-CLAD STEEL REINFORCED ( A.C.S.R./AW ) STANDARD UNE 21.058 CONDUCTEURS D¨ALUMINIUM - ACIER RECOUVERT D´ALUMINIUM NORME UNE 21.058
CONDUCTORES DE Al - ACERO RECUBIERTO DE Al ( LARL ) NORMA ASTM B-549 ALU CONDUCTORS ALU-CLAD STEEL REINFORCED ( A.C.S.R./AW ) STANDARD ASTM B-549 CONDUCTEURS D¨ALUMINIUM - ACIER RECOUVERT D´ALUMINIUM NORME ASTM B-549
161718
CONDUCTORES DE Cu PARA LINEAS ELÉCTRICAS AÉREAS NORMA UNE 21.012 1º R. COPPER STRANDS STANDARD UNE 21.021 1º R. CONDUCTEURS DE Cu POUR LIGNES DE DISTRIBUTION D´ ÉNERGIE NORMA UNE 21.012 1º R. PLETINAS DE COBRE / BARRAS DE COBRE COPPER PLATEE / COPPER BAR PLAGE EN CUIVRE / TIGE EN CUIVRE TUBOS DE ALUMINIO - INTENSIDAD ( A ) / TUBOS DE COBRE INTENSIDAD ( A ) ALUMINIUM TUBES - INTENSITY ( A ) / COPPER TUBES - INTENSITY ( A ) TUBES ALUMINUM - INTENSITÉ ( A ) / TUBES CUIVRE - INTENSITÉ ( A ) CABLES DE ALUMINIO - INTENSIDAD ( A ) / CABLES DE COBRE INTENSIDAD ( A ) ALUMINIUM CABLES - INTENSITY ( A ) / COPPER CABLES - INTENSITY ( A ) CABLES ALUMINUM - INTENSITÉ ( A ) / CABLES CUIVRE - INTENSITÉ ( A )
266
267268
269
269
270
271
TABLAS TECNICAS 1
DATOS COMPARATIVOS ENTRE EL COBRE Y EL ALUMINIO
CARACTERISTICAS COBRE ALUMINIO UNIDADES
SIMBOLO .................................................................................................................... Cu Al
PESO ESPECIFICO A 20°C............................................................................... 8,89 2,71 Kg / dm 3
CARGA DE ROTURA ( DURO )........................................................................ 37 - 45 15 - 20 Kg / mm 2
CARGA DE ROTURA ( recocido )................................................................ 25 - 30 10 - 15 Kg / mm 2
ALARGAMIENTO ( DURO )................................................................................. 0,5 - 1,5 1,2 - 2 %
ALARGAMIENTO ( RECOCIDO )....................................................................... 24 - 33 3 - 9 %MÓDULO DE ELASTICIDAD ............................................................................. 12.000 - 13.000 6.000 - 7.000 Kg / mm 2
CONDUCTIBILIDAD A 20°C ( DURO )........................................................ 56 35 m / mm2
CONDUCTIBILIDAD A 20°C ( RECOCIDO )............................................... 58 36
Ω
Ωm / mm2Ω
COEFICIENTE DE TEMPERATURA A 20°C............................................ 0,0039 0,00390
COEFICIENTE DE TRANSMISIÓN DE CALOR ....................................... 0,9 0,4 cal / cm°Cs
COEFICIENTE DE TRANSMISIÓN DE CALOR ...................................... 3,76 2,09 w / cm °CPUNTO DE FUSIÓN ............................................................................................. 1.083 658 °CCALOR LATENTE DE FUSIÓN ........................................................................ 43,3 100 cal / gCALOR ESPECIFICO ( 1 - 100°C ) ............................................................. 0,09 0,22 cal / g °CCOEFICIENTE DE DILATACIÓN LINEAL ( 20 - 100 °C ) ........... 17,10 -6 23,10 -6
DATOS COMPARATIVOS PARA 2 CONDUCTORES DE IGUAL RESISTENCIA ELECTRICA
RELACIÓN DE SECCIONES .................................................................................. 1 1,61RELACIÓN DE DIÁMETROS ................................................................................RELACIÓN DE PESOS .............................................................................................CARGA DE ROTURA ................................................................................................
MÓDULO ELASTICO .................................................................................................COEFICIENTE DE DILATACIÓN ......................................................................... 1
1111 1,27
0,500,56 - 0,75
0,561,35
DATOS COMPARATIVOS PARA 2 CONDUCTORES DE IGUAL ELEVACIÓN DE TEMPERATURA
RELACIÓN DE SECCIONES .................................................................................
RELACIÓN DE DIÁMETROS ............................................................................RELACIÓN DE PESOS ............................................................................................
CALENTAMIENTO .....................................................................................................
1 1,391,180,43
0,83
11
1
251
TABLAS TECNICAS 2
TUBOS EN ALEACIÓN DE ALUMINIOALU ALLOY TUBETUBE EN ALLIAGE D´ALUMINIUM
DIAMETRO EXTERIOROUTER DIAMETER
DIAMÉTRE EXTÉRIEUR
DIAMETRO INTERIORINNER DIAMETER
DIAMÉTRE INTÉRIEUR( mm )( mm )
SECCIÒNCROSS SECTION
SECTION2( mm )
DIÀMETRODIAMETERDIAMÈTRE
30304050606063707075808090100120140150160170180200250
30304050606063707075808090
100120140150160170180200250
2622304054504764606574708090
106123135148145164184227
175,94326,73549,78706,86537,21863,931382,31631,46
1021,021099,55725,711178,1
1335,181492,252484,97
3511,53357,62902,86185,04322,84825,58616,6
252
TABLAS TECNICAS 3
TUBO I P S ( Al )
TUBE I P S AMERICAINSTANDARD I P S TUBE
DIAMETRO EXTERIOROUTER DIAMETER
DIAMÉTRE EXTÉRIEUR
DIAMETRO INTERIORINNER DIAMETER
DIAMÉTRE INTÉRIEUR( mm )( mm )
SECCIÒNCROSS SECTION
SECTION2( mm )
DIÀMETRODIAMETERDIAMÈTRE
1/81/43/81/23/41
1 1/41 1/22
2 1/23
3 1/24
4 1/256810
10,313,717,221,326,633,442,248,360,373,088,9101,6114,3127,0141,3168,2219,0273,0
7,29,5
12,515,920,926,934,740,652,363,577,788,9101,6114,5128,6155,6203,2254,5
1/81/43/81/23/41
1 1/41 1/22
2 1/23
3 1/24
4 1/256810
43,276,8107,0159,3216,0304,5447,6532,1703,01019,01458,01903,02154,02380,02689,03231,05263,07675,0
TUBO EXTRA GRUESO ( Al ) - EXTRA HEAVY PIPE SIZE - TUBE GROS
10,313,717,221,326,633,442,248,360,373,088,9101,6114,3127,0141,3168,2219,0273,0
5,27,5
10,713,818,724,132,337,949,058,873,585,297,0
108,9122,3146,0193,0247,7
61,9103,8141,2208,3287,8417,0576,0696,0961,0
1477,01967,02393,02870,03342,03941,05476,08230,010384,0
253
TABLAS TECNICAS 4
TUBO DE COBRE
TUBE CUIVRECOPPER TUBE
DIAMETRO EXTERIOROUTER DIAMETER
DIAMÉTRE EXTÉRIEUR
DIAMETRO INTERIORINNER DIAMETER
DIAMÉTRE INTÉRIEUR( mm )( mm )
SECCIÒNCROSS SECTION
SECTION2( mm )
DIÀMETRODIAMETERDIAMÈTRE
1/43/81/23/41
1 1/41 1/22
2 1/23
3 1/24
4 1/256
20263035404550606070708080100120
20263035404550606070708080100120
1620253035404550556065767090110
113,1176,7216,0255,0294,0334,0373,0865,0451,0
1025,0530,0490,01180,01492,01800,0
TUBO DE COBRE U.S. ASTMSTANDARD U.S. COPPER TUBETUBE CUIVRE ASTM AMERICAIN
DIAMETRO EXTERIOROUTER DIAMETER
DIAMÉTRE EXTÉRIEUR
DIAMETRO INTERIORINNER DIAMETER
DIAMÉTRE INTÉRIEUR( mm )( mm )
SECCIÒNCROSS SECTION
SECTION2( mm )
DIÀMETRODIAMETERDIAMÈTRE
13,7117,1521,33
26,6733,4042,1748,2660,3273,0288,9101,6114,3127,0141,3
168,27
9,5312,5415,8820,8826,9734,7540,6452,3763,5077,7788,90101,60114,30128,60155,57
76,8107,
159,3216,0304,5447,6532,1703,01019,01458,01903,02154,02380,02689,03231,0
254