Manual de funcionamiento
Level Plus®
Transmisores magnetoestrictivos de nivel de líquidos con tecnología Temposonics®
CHAMBERED
Índice
1. Información de contacto ...................................................................................................................................... 32. Términos y definiciones ....................................................................................................................................... 33. Introducción .................................................................................................................................................... 5
3.1 Objetivo y uso de este manual ................................................................................................................................................................... 53.2 Símbolos y advertencias empleados ......................................................................................................................................................... 5
4. Instrucciones de seguridad................................................................................................................................... 54.1 Uso previsto .............................................................................................................................................................................................. 54.2 Uso incorrecto previsible ........................................................................................................................................................................... 64.3 Instalación, puesta en servicio y funcionamiento ...................................................................................................................................... 6
5. Resumen del producto ........................................................................................................................................ 65.1 Componentes ............................................................................................................................................................................................ 65.2 Precisión ................................................................................................................................................................................................... 85.3 Garantía ..................................................................................................................................................................................................... 85.4 Número de identificación del modelo ........................................................................................................................................................ 95.5 Almacenamiento ........................................................................................................................................................................................ 95.5 Datos técnicos ......................................................................................................................................................................................... 11
6. Instalación y montaje ........................................................................................................................................126.1 Capacitación ............................................................................................................................................................................................ 126.2 Herramientas ........................................................................................................................................................................................... 126.3 Pasos para la instalación ......................................................................................................................................................................... 126.4 Montaje ................................................................................................................................................................................................... 12
7. Conexiones eléctricas ........................................................................................................................................137.1 Información básica .................................................................................................................................................................................. 137.2 Recomendaciones de seguridad .............................................................................................................................................................. 137.3 Topologías industriales ............................................................................................................................................................................ 137.4 Recomendaciones de cables ................................................................................................................................................................... 147.5 Conducto eléctrico ................................................................................................................................................................................... 147.6 Conexión a tierra ..................................................................................................................................................................................... 157.7 Barreras de seguridad ............................................................................................................................................................................. 15
8. Puesta en servicio ............................................................................................................................................168.1 Capacitación ............................................................................................................................................................................................ 168.2 Herramientas ........................................................................................................................................................................................... 168.3 Software de configuración ....................................................................................................................................................................... 168.4 Pasos para la puesta en servicio ............................................................................................................................................................. 16
9. Mantenimiento ................................................................................................................................................179.1 Capacitación ............................................................................................................................................................................................ 179.2 Herramientas ........................................................................................................................................................................................... 179.3 Inspección ............................................................................................................................................................................................... 179.4 Mantenimiento preventivo ....................................................................................................................................................................... 17
10. Reparación ...................................................................................................................................................1710.1 Política de autorización de devolución de material (RMA, por sus siglas en inglés) .............................................................................. 1710.2 Capacitación .......................................................................................................................................................................................... 1710.3 Herramientas ......................................................................................................................................................................................... 1710.4 Solución de problemas .......................................................................................................................................................................... 1810.5 Software de configuración ..................................................................................................................................................................... 18
11. Piezas de repuesto ..........................................................................................................................................1812. Interfaz ........................................................................................................................................................18
12.1 Modbus ................................................................................................................................................................................................. 1812.2 DDA ....................................................................................................................................................................................................... 1812.3 HART® .................................................................................................................................................................................................. 18
13. Información de la agencia .................................................................................................................................1913.1 Resumen de aprobaciones .................................................................................................................................................................... 1913.2 Certificados ........................................................................................................................................................................................... 2113.3 FM (NEC) ............................................................................................................................................................................................... 2113.4 FMC (CEC) ............................................................................................................................................................................................. 3113.5 ATEX y IECEx ......................................................................................................................................................................................... 45
Level Plus® CON COMPARTIMIENTOSManual de funcionamiento
I 3 I
1. Información de contacto
Estados Unidos
GeneralTel: +1-919-677-0100Fax: +1-919-677-2343Correo electrónico: [email protected]://www.mtssensors.com
Dirección postal y dirección de envíoMTS Systems CorporationDivisión de Sensores3001 Sheldon DriveCary, Carolina del Norte, 27513, EE. UU.
Atención al clienteTel: +1-800-633-7609Fax: +1-800-498-4442Correo electrónico: [email protected]
Soporte técnico y aplicacionesSoporte técnico para emergencias 24 horasTel: +1-800-633-7609Correo electrónico: [email protected]
Alemania
GeneralTel: +49-2351-9587-0Fax: +49-2351-56491Correo electrónico: [email protected]://www.mtssensors.com
Dirección postal y dirección de envíoMTS Sensor Technologie, GmbH & Co. KGAuf dem Schüffel 958513 Lüdenscheid, Alemania
Soporte técnico y aplicacionesTel: +49-2351-9587-0Correo electrónico: [email protected]://www.mtssensors.com
2. Términos y definiciones
6A Aceites pesados“Aceites crudos generalizados”, corrección volumétrica a 60 °F (15.5 °C) contra gravedad API.
6C ModReferencia de temperatura ajustable para definir el VCF.
6C Químico“Factores de corrección del volumen (VCF, por sus siglas inglés)” para aplicaciones individuales y especiales, corrección volumétrica a 60 °F (15.5 °C) contra coeficientes de dilatación térmica.
Aceites ligeros 6B“Productos generalizados”, corrección volumétrica a 60 °F (15.5 °C) contra gravedad API.
C
Capacidad de trabajo El volumen máximo de líquido que el usuario desea que contenga su recipiente; por lo general, es el 80% del volumen máximo del recipiente antes de que desborde.
D
DDA (Direct Digital Access, acceso digital directo)Protocolo digital de marca registrada desarrollado por MTS para usar en áreas intrínsecamente seguras.
Densidad Masa dividida por el volumen de un objeto a una temperatura específica. El valor de la densidad debe ingresarse en lb/ft3
Desplazamiento de esperaValor de desplazamiento que representa el volumen adicional en un esfera en relación a una geometría esférica no uniforme; el valor se usa para calcular el volumen junto con el radio de la esfera.
G
GOVI (Gross Observed Volume of the Interface, gross volumen bruto observado de la interfaz)El volumen total del tanque ocupado por el líquido de la interfaz. El GOVI solo se obtiene midiendo dos líquidos, y se calcula restando el volumen del producto al volumen de líquido total del tanque (GOVT – GOVP).
GOVP (Gross Observed Volume of the Product, volumen bruto observado del producto)El volumen total del tanque ocupado por el líquido del producto. Si se mide un solo líquido, es también el volumen total del líquido del tanque (GOVT). Si se miden dos líquidos, es el volumen total del líquido del tanque menos el volumen del líquido de la interfaz (GOVT – GOVI).GOVT (Total Gross Observed Volume, volumen bruto observado total)El volumen total del líquido del tanque. Si se mide un solo líquido, es igual
Level Plus® CON COMPARTIMIENTOSManual de funcionamiento
I 4 I
al volumen del producto (GOVP). Si se miden dos líquidos, es igual al volumen de los líquidos del producto y la interfaz (GOVP + GOVI).
GOVU (Gross Observed Volume Ullage, volumen bruto observado de merma)La diferencia entre la capacidad de trabajo del tanque y el volumen total en el tanque (capacidad de trabajo – GOVT).
Gravedad API Medida que compara cuán pesado o ligero es el líquido de petróleo en comparación con el agua. Los valores permitidos son de 0 a 100 grados API para (6A) y de 0 a 85 grados API para (6B).
Gravedad específica La proporción de densidad de un líquido respecto a la densidad del agua en las mismas condiciones.
H
HART® Protocolo de comunicación bidireccional que ofrece acceso a información entre los instrumentos de campo inteligentes y los sistemas principales.
I
Ignífugo Tipo de protección que consiste en una carcasa que aloja en su interior aquellas piezas que podrían causar la ignición de una atmósfera con gases explosivos; que puede soportar la presión generada por la explosión interna de una mezcla explosiva, y que evita la transmisión de dicha explosión a una atmósfera con gases explosivos alrededor de la carcasa.
Interfaz Adj..; La interfaz gráfica de usuario (GUI, por sus siglas inglés) de software que permite al usuario acceder a los protocolos de software (HART®, DDA, MODBUS).
Interfaz Sustantivo; Medición del nivel de un líquido cuando ese líquido se encuentra por debajo de otro.
M
Masa Propiedad de un cuerpo que hace que tenga peso en un campo gravitacional. Se calcula multiplicando la densidad a la temperatura de referencia por el factor de corrección del volumen (densidad × VCF).
Método de corrección de temperatura Uno de los cinco métodos de corrección del producto que se usan para corregir el volumen del producto en el tanque debido a cambios en la temperatura a partir de 60 °F (15.5 °C), incluyendo 6A, 6B, 6C, 6C Mod y la tabla personalizada.
MODBUS Protocolo de comunicaciones en serie publicado por Modicon en 1979 para usar con sus controladores lógicos programables (PLC, por sus siglas en inglés). Se ha convertido en un protocolo de comunicaciones estándar en la industria, y es ahora el medio disponible más común para conectar dispositivos electrónicos industriales.
Modo de cálculo de volumen Uno de los dos métodos que se usan para calcular mediciones de volumen a partir de mediciones de nivel, incluida la esfera y la tabla de ajuste.
N
NEMA Tipo 4X La carcasa de un producto está pensada para el uso en espacios cerrados y al aire libre, sobre todo para brindar un grado de protección contra corrosión, polvo y lluvia acarreados por el viento, salpicaduras y agua dirigida por una manguera; así como para resistir los daños provocados por la formación de hielo en la carcasa. No están pensadas para brindar protección contra condiciones tales como la condensación interior o el congelamiento interno.
NPT Estándar estadounidense que define las roscas cónicas de tubería que se usan para unir las tuberías y sus accesorios.
NSVP (Net Standard Volume of the Product, volumen neto estándar del producto)El volumen, corregido en función de la temperatura, del producto líquido del tanque; exige que el transmisor tenga capacidad de medición de temperatura. El NSVP se calcula multiplicando el volumen del producto líquido por el factor de corrección del volumen según la temperatura (GOVP × VCF).
R
Radio de esfera El radio interno de la esfera que contiene el líquido; el valor se usa para calcular el volumen junto con el desplazamiento de esfera.
Level Plus® CON COMPARTIMIENTOSManual de funcionamiento
I 5 I
Resistente a explosiones Tipo de protección que consiste en una carcasa que aloja en su interior aquellas piezas que podrían causar la ignición de una atmósfera con gases explosivos; que puede soportar la presión generada por la explosión interna de una mezcla explosiva, y que evita la transmisión de dicha explosión a una atmósfera con gases explosivos alrededor de la carcasa.
S Seguridad intrínseca Tipo de protección basada en la restricción de la energía eléctrica, dentro de un aparato con cables interconectados expuestos a una atmósfera potencialmente explosiva, a un nivel por debajo del nivel que puede causar ignición como resultado de chispas o calor.
T
Tabla de ajuste Tabla de medición que correlaciona la altura de un recipiente con el volumen contenido en esa altura. El transmisor puede contener hasta 100 puntos.
TEC (Thermal Expansion Coefficient, coeficiente de dilatación térmica)Valor que correlaciona el cambio en la temperatura de un objeto con el cambio en su volumen. Los valores permitidos son de 270.0 a 930.0. Las unidades de TEC están en 10 E-6/Deg F.
Temperatura de referencia La temperatura a la cual se produce la medición de densidad; los valores permitidos son de 32 °F a 150 °F (0 °C a 66 °C).
V
VCF (Volume Correction Factors, factor de corrección del volumen) Una tabla de medición que correlaciona los puntos de temperatura con factores de corrección para la dilatación/contracción de líquidos. El transmisor puede contener hasta 50 puntos.
3. Introducción
3.1 Objetivo y uso de este manual
Importante:Antes de iniciar el funcionamiento del equipo, lea este documento atentamente y respete la información de seguridad.
El contenido de este documento técnico y sus distintos anexos tiene como fin brindar información sobre el montaje, la instalación y la puesta en servicio por parte de personal de servicio calificado conforme con IEC 60079-14 y las reglamentaciones locales, o por técnicos de servicio capacitados de MTS.
3.2 Símbolos y advertencias empleados
El propósito de las advertencias es cuidar su seguridad personal y evitar daños al producto descrito o a los dispositivos conectados. En este documento, la información de seguridad y las advertencias para evitar peligros que podrían afectar la vida y la salud del personal o causar daños materiales se resaltan por medio del pictograma que precede a dicha información, y que se define a continuación.
Símbolo Significado
AVISO Este símbolo se usa para señalar situaciones que pueden producir daños materiales o lesiones personales.
4. Instrucciones de seguridad
4.1 Uso previsto
El transmisor de nivel de líquidos está diseñado para medir el nivel de líquidos contenido por una estructura, así como la temperatura del líquido. El producto solo se puede usar para las aplicaciones que se definen en los puntos 1 a 4 y solo junto con dispositivos y componentes de terceros recomendados o aprobados por MTS Sensors. Como requisito previo de un funcionamiento seguro y adecuado, el producto requiere un correcto transporte, almacenamiento, montaje y puesta en servicio. Además debe ser operado con extremo cuidado.
1. La aplicación no excede las especificaciones de desempeño del producto que se indican en el capítulo 5.5
2. El producto solo puede instalarse en áreas peligrosas según lo especificado en las certificaciones de aprobación en el capítulo 13, con las condiciones de uso especiales definidas en el capítulo 13, o en áreas seguras.
3. Los líquidos que se miden son compatibles con las piezas humedecidas seleccionadas del producto.
4. Para lograr un correcto funcionamiento y recibir la aprobación de seguridad, se deben usar flotadores de MTS.
Level Plus® CON COMPARTIMIENTOSManual de funcionamiento
I 6 I
Uso incorrecto previsible ConsecuenciaMala conexión con el sensor
Posible daño al sistema electrónico; consulte el capítulo 7 para obtener información sobre las conexiones eléctricas
Instalación inadecuada Daños físicos; consulte el capítulo 6 para obtener información sobre la instalación
Instalación en áreas peligrosas no aprobadas
Posibles chispasConsulte el capítulo 13 para obtener información sobre la agencia
Temperatura del proceso fuera de rango
Degradación de la señal, posible daño en el sensor; consulte el capítulo 5.5 para ver las especificaciones
Suministro de energía fuera de rango
Ausencia de comunicación, posible daño en el sensor; consulte el capítulo 5.5 para ver las especificaciones
Presión del proceso fuera de rango
Posible daño en el sensor; consulte el capítulo 5.5 para ver las especificaciones
Compatibilidad química inadecuada
Posible daño en el sensor; el cliente debe seleccionar un material humedecido compatible con el líquido del tanque
Modificar sensor Garantía nula, aprobación de material peligroso nula; el cliente debe comunicarse con la fábrica para unidades personalizadas
Conexión a tierra inadecuada
Posible daño en el sensor, protección total en riesgo; consulte el capítulo 7.6 para obtener información sobre la conexión a tierra
Tabla 1: Uso incorrecto previsible
4.3 Instalación, puesta en servicio y funcionamiento
1. Utilice equipos de protección personal adecuados, como casco, zapatos de seguridad, ropa ignífuga, lentes de seguridad y protección auditiva.
2. Respete las especificaciones detalladas en el documento técnico. 3. Se recomienda la participación de dos (2) personas para llevar
a cabo una correcta instalación, puesta en servicio y reparación del transmisor de nivel.
4. Asegúrese de que el equipo usado en un entorno peligroso se seleccione e instale en conformidad con las reglamentaciones que rigen la instalación geográfica y la planta. Instale únicamente equipos que cumplan con los tipos de protección relevantes para las clases, divisiones, zonas, categorías, grupo de gas y código de temperatura aplicables.
5. Proteja el sensor contra daños mecánicos durante la instalación y el funcionamiento.
6. No use productos dañados y evite el uso accidental. Marque los productos dañados como defectuosos.
7. Conecte el sensor cuidadosamente y preste atención a la polaridad de las conexiones. MTS recomienda no realizar conexiones mientras la corriente está conectada.
4.2 Uso incorrecto previsible 8. Antes de encender el equipo, asegúrese de no poner en riesgo la seguridad de las personas al encender el transmisor de nivel o iniciar el proceso.
9. Realice el mantenimiento preventivo regularmente para evitar riesgos de seguridad
10. Asegúrese de que no haya alambres de cable sueltos o que sobresalgan de la conexión del bloque de terminales y que pudieran hacer cortocircuito y ocasionar problemas.
11. Asegúrese de que no haya alambres de cables ni blindaje en contacto con la carcasa del módulo electrónico.
5. Resumen del producto
El transmisor de nivel de líquido Level Plus® CON COMPARTIMIENTOS es un transmisor magnetoestrictivo multifuncional continuo que brinda nivel de producto y nivel de interfaz al usuario a través de Modbus, DDA, Analógico (4 a 20 mA) o HART. La tecnología magnetoestrictiva es una de las tecnologías de nivel más precisas y repetibles disponibles hasta la fecha.
MTS es responsable de la invención y el suministro de la tecnología magnetoestrictiva y ha brindado servicios a la industria de los niveles a lo largo de más de 35 años.
Industrias• Petróleo• Gas de petróleo líquido• Farmacéutica• Alimentos y bebidas• Química• Minería
5.1 Componentes
El transmisor de nivel de líquidos Level Plus® CON COMPARTIMIENTOS tiene tres componentes principales: una carcasa, tubería externa y el sistema electrónico. Cambiar los componentes del transmisor permite personalizar el transmisor para prácticamente cualquier aplicación.
CarcasasLos transmisores Level Plus® CON COMPARTIMIENTOS están disponibles con dos configuraciones de carcasas: carcasas con cavidad individual o doble, según se muestra a continuación. Los orificios del conducto en las carcasas de cavidad individual (opciones D, L) y con montaje electrónico estándar (7,8) son orificios NPT de 3/4" para aprobaciones FM y FMC y orificios M20 para aprobaciones ATEX y IECEx. Los orificios del conducto en las carcasas de cavidad individual (opciones D, L) y con montaje electrónico de 90 grados (3,4,5,6) son NPT de 3/4" para todas las aprobaciones y se suministra un adaptador M20 para aprobaciones ATEX y IECEx. El orificio del conducto en las carcasas de cavidad doble (opción E) siempre requiere de un montaje electrónico de 90 grados (3,4,5,6) y cuenta con orificio NPT de 3/4" para aprobaciones FM y FMC y orificio M20 para aprobaciones ATEX y IECEx.
Level Plus® CON COMPARTIMIENTOSManual de funcionamiento
I 7 I
Fig. 1: Carcasa con cavidad individual
Fig. 2: Carcasa con cavidad doble
1
1
2
2
3
3
4
4
A A
B B
C C
D D
REV ECO # DESCRIPTION
TITLE
SIZE DWG NO. REV
PRODUCT LINESCALE:
BY DATE
SHEET OF
UNLESS OTHERWISE SPECIFIEDTOLERANCES
0 PLACESMM
1 PLACEMM
ANGLES� � �� 0.5 � 0.1
- THREAD DEPTHS ARE TO MIN. FULL THDS- DRILL DEPTHS ARE TO FULL DIA.- REMOVE BURRS AND SHARP EDGES- DO NOT SCALE PRINT- MACHINED SURFACE FINISH 3.2uM [125 uIn]
PROPRIETARY DATATHE INFORMATION AND DESIGN(S) DISCLOSEDHEREIN ARE THE PROPERTY OF MTS SYSTEMSCORPORATION AND MAY NOT BE USED,REPRODUCED OR DISCLOSED IN ANY FORMEXCEPT AS GRANTED IN WRITING BY MTSSYSTEMS CORPORATION. THIS RESTRICTIONEXCLUDES INFORMATION THAT IS IN THE PUBLIC DOMAIN OR WAS LEGITIMATELY IN THEPRIOR POSSESSION OF THE RECIPIENT.
mMTS SYSTEMS CORPORATIONSENSORS DIVISION3001 SHELDON DRIVE, CARY, NC 27513
METRIC
FIRST ANGLE C LL drawing
1 1
DRAWN BY:
114 mm(4.5 in.)
127 mm(5 in.)
124 mm(4.9 in.)
132 mm(5.2 in.)
87 mm(3.4 in.)
109 mm(4.3 in.)
75 mm(3 in.)
206 mm(8.1 in.)
127 mm(5 in.)
117 mm(4.6 in.)
145 mm(5.7 in.)
1
1
2
2
3
3
4
4
A A
B B
C C
D D
REV ECO # DESCRIPTION
TITLE
SIZE DWG NO. REV
PRODUCT LINESCALE:
BY DATE
SHEET OF
UNLESS OTHERWISE SPECIFIEDTOLERANCES
0 PLACESMM
1 PLACEMM
ANGLES� � �� 0.5 � 0.1
- THREAD DEPTHS ARE TO MIN. FULL THDS- DRILL DEPTHS ARE TO FULL DIA.- REMOVE BURRS AND SHARP EDGES- DO NOT SCALE PRINT- MACHINED SURFACE FINISH 3.2uM [125 uIn]
PROPRIETARY DATATHE INFORMATION AND DESIGN(S) DISCLOSEDHEREIN ARE THE PROPERTY OF MTS SYSTEMSCORPORATION AND MAY NOT BE USED,REPRODUCED OR DISCLOSED IN ANY FORMEXCEPT AS GRANTED IN WRITING BY MTSSYSTEMS CORPORATION. THIS RESTRICTIONEXCLUDES INFORMATION THAT IS IN THE PUBLIC DOMAIN OR WAS LEGITIMATELY IN THEPRIOR POSSESSION OF THE RECIPIENT.
mMTS SYSTEMS CORPORATIONSENSORS DIVISION3001 SHELDON DRIVE, CARY, NC 27513
METRIC
FIRST ANGLE C LL drawing
1 1
DRAWN BY:
114 mm(4.5 in.)
127 mm(5 in.)
124 mm(4.9 in.)
132 mm(5.2 in.)
87 mm(3.4 in.)
109 mm(4.3 in.)
75 mm(3 in.)
206 mm(8.1 in.)
127 mm(5 in.)
117 mm(4.6 in.)
145 mm(5.7 in.)
Fig. 3: Carcasa de acero inoxidable con cavidad individual
1
1
2
2
3
3
4
4
A A
B B
C C
D D
TITLE
SIZE DWG NO. REV
PRODUCT LINESCALE: SHEET OF
UNLESS OTHERWISE SPECIFIEDTOLERANCES
0 PLACESMM
1 PLACEMM
ANGLES� � �� 0.5 � 0.1
- THREAD DEPTHS ARE TO MIN. FULL THDS- DRILL DEPTHS ARE TO FULL DIA.- REMOVE BURRS AND SHARP EDGES- DO NOT SCALE PRINT- MACHINED SURFACE FINISH 3.2uM [125 uIn]
PROPRIETARY DATATHE INFORMATION AND DESIGN(S) DISCLOSEDHEREIN ARE THE PROPERTY OF MTS SYSTEMSCORPORATION AND MAY NOT BE USED,REPRODUCED OR DISCLOSED IN ANY FORMEXCEPT AS GRANTED IN WRITING BY MTSSYSTEMS CORPORATION. THIS RESTRICTIONEXCLUDES INFORMATION THAT IS IN THE PUBLIC DOMAIN OR WAS LEGITIMATELY IN THEPRIOR POSSESSION OF THE RECIPIENT.
mMTS SYSTEMS CORPORATIONSENSORS DIVISION3001 SHELDON DRIVE, CARY, NC 27513
METRIC
FIRST ANGLE C
1 1
DRAWN BY:
REV ECO# DESCRIPTION BY DATE
178 mm(7 in.)
135 mm(5.30 in.)
135 mm(5.3 in.)
152 mm(6 in.)
1
1
2
2
3
3
4
4
A A
B B
C C
D D
TITLE
SIZE DWG NO. REV
PRODUCT LINESCALE: SHEET OF
UNLESS OTHERWISE SPECIFIEDTOLERANCES
0 PLACESMM
1 PLACEMM
ANGLES� � �� 0.5 � 0.1
- THREAD DEPTHS ARE TO MIN. FULL THDS- DRILL DEPTHS ARE TO FULL DIA.- REMOVE BURRS AND SHARP EDGES- DO NOT SCALE PRINT- MACHINED SURFACE FINISH 3.2uM [125 uIn]
PROPRIETARY DATATHE INFORMATION AND DESIGN(S) DISCLOSEDHEREIN ARE THE PROPERTY OF MTS SYSTEMSCORPORATION AND MAY NOT BE USED,REPRODUCED OR DISCLOSED IN ANY FORMEXCEPT AS GRANTED IN WRITING BY MTSSYSTEMS CORPORATION. THIS RESTRICTIONEXCLUDES INFORMATION THAT IS IN THE PUBLIC DOMAIN OR WAS LEGITIMATELY IN THEPRIOR POSSESSION OF THE RECIPIENT.
mMTS SYSTEMS CORPORATIONSENSORS DIVISION3001 SHELDON DRIVE, CARY, NC 27513
METRIC
FIRST ANGLE C
1 1
DRAWN BY:
REV ECO# DESCRIPTION BY DATE
178 mm(7 in.)
135 mm(5.30 in.)
135 mm(5.3 in.)
152 mm(6 in.)
Configuraciones de tubería externaLa tubería externa se fabrica en distintas configuraciones. El transmisor CON COMPARTIMIENTOS está disponible en tubería rígida. Para conocer otras opciones de tubería, consulte otras opciones de MTS como Tank Slayer®, RefineMe®, SoClean® o USTDII. Flotadores USTDII
1
1
2
2
3
3
4
4
A A
B B
C C
D D
REV ECO # DESCRIPTION
TITLE
SIZE DWG NO. REV
PRODUCT LINESCALE:
BY DATE
SHEET OF
UNLESS OTHERWISE SPECIFIEDTOLERANCES
0 PLACESMM
1 PLACEMM
ANGLES� � �� 0.5 � 0.1
- THREAD DEPTHS ARE TO MIN. FULL THDS- DRILL DEPTHS ARE TO FULL DIA.- REMOVE BURRS AND SHARP EDGES- DO NOT SCALE PRINT- MACHINED SURFACE FINISH 3.2uM [125 uIn]
PROPRIETARY DATATHE INFORMATION AND DESIGN(S) DISCLOSEDHEREIN ARE THE PROPERTY OF MTS SYSTEMSCORPORATION AND MAY NOT BE USED,REPRODUCED OR DISCLOSED IN ANY FORMEXCEPT AS GRANTED IN WRITING BY MTSSYSTEMS CORPORATION. THIS RESTRICTIONEXCLUDES INFORMATION THAT IS IN THE PUBLIC DOMAIN OR WAS LEGITIMATELY IN THEPRIOR POSSESSION OF THE RECIPIENT.
mMTS SYSTEMS CORPORATIONSENSORS DIVISION3001 SHELDON DRIVE, CARY, NC 27513
METRIC
FIRST ANGLE C Marketing
1 1
DRAWN BY:
***NO REVISIONS SHALL BE MADE WITHOUT THE NOTIFICATION TO APPROVAL AGENCY(S).***
Order length
304.8mm (12 in)
Pipe diameter16mm (0.625 in)
Tip of transmitter
Tank Flange
1 in NPT Adjustablecompression fitting, male
127mm [5 in ]
Order Length
Pipe diameter (0.625 in. dia)constructed of 316l stainless steel
Sanitary process connection (sanitary cap)
74 mm (2.9 in.) minInactive zone
Order Length
54 mm (2.1 in.)minimum
Fig. 4: Carcasa de acero inoxidable con cavidad individual
Los transmisores CON COMPARTIMIENTOS ofrecen numerosos flotadores para distintas aplicaciones, por ejemplo, de acero inoxidable o de aleación Hastelloy, tanto para nivel del producto como para nivel de la interfaz. Para poder detectar con precisión el nivel de la interfaz, es necesario que haya una diferencia en la gravedad específica de al menos 0.05 pulgadas entre los líquidos del producto y de la interfaz. Para obtener información detallada sobre los flotadores, consulte el Catálogo de accesorios, (número de pieza de MTS 551103).
Para obtener asistencia para seleccionar un flotador específico para su aplicación, comuníquese con Soporte Técnico, con la siguiente información:• La gravedad específica de líquidos que se está midiendo• Temperatura del proceso• Tamaño de abertura del proceso• Presión del recipiente
Level Plus® CON COMPARTIMIENTOSManual de funcionamiento
I 8 I
Los transmisores CON COMPARTIMIENTOS deben usarse con un flotador que tenga un peso equilibrado y esté hecho de acero inoxidable o aleación Hastelloy® C. Esto permite que el flotador se mantenga en contacto con la tubería para evitar la acumulación de una carga electrostática. Para obtener información detallada sobre los flotadores, consulte el Catálogo de accesorios, (número de pieza de MTS 551103).
Sistema electrónico internoTodos los transmisores cuentan con dos componentes electrónicos, que son un elemento sensor y un conjunto de tablero. Todos los transmisores CON COMPARTIMIENTOS tienen elementos sensores rígidos. El conjunto de tablero está compuesto por tres tableros electrónicos y una pantalla.
El transmisor CON COMPARTIMIENTOS tiene una función de sensor de temperatura opcional. El dispositivo sensor de temperatura es un termómetro digital montado dentro del conjunto de la tubería externa del transmisor. El transmisor CON COMPARTIMIENTOS se puede pedir con 1, 5, 12 o 16 puntos de temperatura.
PantallaTodos los transmisores de nivel de líquidos de la Serie LP se envían con un lápiz (pieza de MTS n.º 404108) para manejar la pantalla. Para carcasas con cavidad individual y doble, el lápiz está diseñado para permitir la programación de la unidad sin tener que retirar la carcasa. Al utilizar el lápiz, asegúrese de alinear el lápiz con el contorno que rodea a los botones en esa misma orientación. En caso de no alinear correctamente el lápiz, la pantalla podría no funcionar adecuadamente. La contraseña para acceder al menú es 27513. Para obtener detalles adicionales, consulte el Manual de la interfaz de Modbus (pieza de MTS n.º 551700), el Manual de la interfaz de DDA (pieza de MTS n.º 551701) y el Manual de la interfaz de HART® (pieza de MTS n.º 551702).
Fig. 5: Lápiz (pieza de MTS n.º 404108)
AccesoriosMTS también ofrece una serie de pantallas, carcasas, convertidores y otros accesorios; consulte el Catálogo de accesorios, (número de pieza de MTS 551103).
5.2 Precisión
Para los transmisores magnetoestrictivos, la precisión inherente se mide en términos de ausencia de linealidad. La ausencia de linealidad es una medición de cualquier imperfección en la guía de onda que se refleja en la linealidad de la salida del transmisor. Las tolerancias de MTS reflejan una ausencia de linealidad máxima de ±1 mm. MTS puede lograr estas tolerancias tan estrictas gracias a la fabricación de todas sus guías de onda a partir de una aleación patentada y de la verificación del 100% de los transmisores antes del envío.
5.3 Garantía
Importante:Comuníquese con Soporte Técnico o con Atención al Cliente para recibir asistencia si sospecha que el transmisor no funciona correctamente. Soporte Técnico puede ayudarlo con información relativa a la solución de problemas, la sustitución de piezas y la autorización de devolución de material (RMA, por sus siglas en inglés) si es necesario.
Todos los transmisores Level Plus® tienen una garantía limitada de dos años a partir de la fecha de envío desde la fábrica. Se puede comprar una garantía extendida adicional. Todas las devoluciones de transmisores deben estar obligatoriamente acompañadas de un número de autorización de devolución de material (RMA, por sus siglas en inglés). Todas las unidades usadas en un proceso deben limpiarse en conformidad con los estándares de la OSHA antes de devolverlas a la fábrica. Además, una hoja de datos de seguridad del material (MSDS, por sus siglas en inglés) debe acompañar al transmisor que se usó en cualquier proceso.
Fig. 6: Pantalla
Level Plus® CON COMPARTIMIENTOSManual de funcionamiento
I 9 I
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22
L P C
a b c d e f g h i j k l m n o p
a Modelo de sensor
L P C Transmisor de nivel CON COMPARTIMIENTOS
b Salida
M Modbus
D DDA
3 1 circuito con HART®
6 1 circuito con HART® y SIL 2
d Montaje del sistema electrónico
3 Carcasa curva de 90°, arriba izquierda
4 Carcasa curva de 90°, arriba derecha
5 Carcasa curva de 90°, abajo izquierda
6 Carcasa curva de 90°, abajo derecha
7 Montaje superior
8 Montaje inferior
f Materiales de construcción (piezas humedecidas)*
1 Acero inoxidable 316L
e Tubería del sensor
B Tubería con diámetro externo de 5/8"
R Tubería con diámetro externo de 1/2"
Y Tubería con diámetro externo de 10 mm
c Tipo de carcasa
D Cavidad individual con pantalla
E Cavidad doble con pantalla
L Cavidad individual de acero inoxidable c/pantalla
*/ Comuníquese con la fábrica para otros materiales
5.4 Número de identificación del modelo
g Tipo de conexión del proceso
X Ninguno
h Tamaño de conexión del proceso
X Ninguno
i Cantidad de TD (termómetros digitales)
0 Ninguno
j Colocación de los TD
X Ninguno
l Método de protección
F Resistente a explosiones/ignífugo (solo para carcasas tipo D, E o L)
I Seguridad intrínseca
X Sin aprobación
m Grupo de gas
A Grupo A (no disponible con organismo acreditado “C = CEC (FMC)” y método de protección “F = ignífugo/resistente a explosiones”)
B Grupo B
C Grupo C
D Grupo D
3 IIC (solo seguridad intrínseca)
4 IIB + H2 (solo resistente a explosiones/ignífugo)
X Ninguno
(continúa en la página siguiente…)
k Organismo acreditado
B INMETRO
C CEC (FMC)
E ATEX
F NEC (FM)
I IEC
K KC
N NEPSI
T CML/TIIS
P CCOE
X None
Level Plus® CON COMPARTIMIENTOSManual de funcionamiento
I 10 I
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22
L P T
a b c d e f g h i j k l m n o p
n Unidad de medida
M Milímetros (métrico)
U Pulgadas (típico en EE. UU.)
p Especial
S Producto estándar
o Longitud (sin espacios decimales) *
X X X X X Tubería rígida: 12 a 144 in (código 01200 a 14400)
X X X X X Tubería rígida: 305 a 3658 mm (código 00305 a 03658)
AVISO
Accesorios tales como flotadores, cables y pantallas remotas deben pedirse por separado. Todos los accesorios se muestran en el Catálogo de accesorios (pieza de MTS n.º 551103).
*/ Comuníquese con la fábrica para longitudes superiores
Level Plus® CON COMPARTIMIENTOSManual de funcionamiento
I 11 I
5.5 Datos técnicos
Salida de nivel
Variable medida Nivel del producto
Señal de salida/Protocolo Modbus RTU, DDA, Analógico (4…20 mA), HART®
Longitud del pedido305 mm (12 in) a 3658 mm (144 in) (la longitud del pedido es igual al rango de medición más la zona inactiva / comuníquese con la fábrica para longitudes superiores)
Precisión inherente ±1 mm (0.039 in)
Repetibilidad 0.001% F.S. o 0.381 mm (0.015 in), la cifra que resulte mayor * (en cualquier dirección)
Salida de temperatura
Variable medida Temperaturas promedio y de múltiples puntos (Modbus, DDA)Temperatura de punto individual (Analógico, HART®)
Precisión de temperatura (Modbus, DDA) Rango ±0.2 °C (0.4 °F) −40…−20 °C (−40…−4 °F),Rango ±0.1 °C (0.2 °F) −20…+70 °C (−4…+158 °F),Rango ±0.15 °C (0.3 °F) +70…+100 °C (+158…+212 °F),Rango ±0.5 °C (0.9 °F) +100…+105 °C (+ 212 …221 °F)
Precisión de temperatura (Analógico, HART®) Rango ±0.28 °C (0.5 °F) −40…+105 °C (−40…+221 °F)
Sistema electrónico
Voltaje de entrada 10.5…28 V CC
A prueba de errores Alto, escala completa (Modbus, DDA)Bajo, 3.5 mA predeterminado o alto, 22.8 mA (Analógico, HART®)
Protección de polaridad inversa Diodo de serie
EMC EN 61326-1, EN 61326-2-3, EN 61326-3-2, EN 61000-6-2, EN 61000-6-3, EN 61000-4-2, EN 61000-4-3, EN 61000-4-4, EN 61000-4-5, EN 61000-4-6, EN 61000-4-8, EN 61000-4-11
Ambiental
Clasificación de la carcasa NEMA tipo 4X, IP65
Humedad 0…100% de humedad relativa, sin condensación
Temperaturas de funcionamiento Sistema electrónico: −40…+71 °C (−40…+160 ºF)Elemento sensor: −40…+125 °C (−40…+257 °F) (comuníquese con la fábrica para rangos de temperatura específicos)
Materiales Acero inoxidable 316L, aluminio con recubrimiento epóxico
Instalación en campo
Dimensiones de la carcasa Cavidad individual: 145 mm (5.7 in) de an. × por 127 mm (5 in) de prof. × 109 mm (4.3 in) de al. Cavidad doble: 117 mm (4.6 in) de an. × por 127 mm (5 in) de prof. × 206 mm (8.1 in) de al.Cavidad individual de acero inoxidable: 178 mm (7.1 in) de an. × por 135 mm (5.3 in) de prof. × 153 mm (6 in) de al.
Montaje
Manguera flexible 1 in. Accesorio MNPT o BSPP ajustable, montaje en brida
Cableado
Conexiones Cable blindado de 4 alambres o par trenzado
Conexiones eléctricas
Cavidad individual o doble ¾ in. Orificio del conducto FNPT, M20 para versión ATEX/IECEx
NEMA Tipo 4X ½ in. Orificio del conducto FNTP
Pantalla
Variables medidas Nivel del producto, nivel de la interfaz y temperatura
*/ Solo con flotadores recomendados por MTS
Level Plus® CON COMPARTIMIENTOSManual de funcionamiento
I 12 I
Inactive Zone74 mm (2.9 in.)
Inactive Zone54 mm (2.1 in.)
Orderlength
MeasuringRange
127 mm(5 in.)
(Circle one)4 mA or 20 mA
Setpoint
(Circle one)4 mA or 20 mA
Setpoint
Order LengthStandard
74 mm (2.9 in.)Standard
Level Plus
145 mm(5.7 in.)
PressureBarrier
ElectronicHead 155 mm
(6.1 in.)Protection
MethodI or X
195 mm(7.7 in.)
Protection Method
F
6. Instalación y montaje
6.1 Capacitación
Advertencia: Cuando el tubo/manguera del transmisor de nivel Serie LP se instala o se quita del tanque, se produce una liberación de vapores inflamables. Tome todas las precauciones necesarias al instalar o quitar el transmisor de nivel debido a la liberación de vapores inflamables.
La instalación solo debe ser realizada por personal de servicio calificado de conformidad con IEC 60079-14 y las reglamentaciones locales, o por técnicos de servicio capacitados por MTS. MTS ofrece capacitación para la instalación, puesta en servicio, mantenimiento y reparación a través de la web o en persona. MTS también ofrece servicios directos de fábrica para estas mismas funciones. Comuníquese con MTS para hablar sobre capacitación o servicios directos de fábrica antes de empezar.
6.2 Herramientas
• Pinzas tipo Channel-lock• Destornillador con cabezal común y destornillador plano• Pueden ser necesarias herramientas adicionales según el fabricante
de MLG
6.3 Pasos para la instalación
PrecauciónSe recomienda que el ensamblaje y el montaje de este transmisor no sea realizado por una sola persona. Para garantizar un ensamblaje adecuado y seguro del transmisor CON COMPARTIMIENTOS, se recomienda la participación de por lo menos dos (2) personas. También se recomienda usar guantes. Para las áreas de trabajo se requiere el uso de EPP, como zapatos de seguridad, lentes de seguridad, casco y ropa ignífuga.
1. Consulte la Sección 4.3 antes de empezar. 2. Realice los pasos 1-9 de la sección 8.4.1 para Modbus o DDA.
Realice los pasos 1-8 de la sección 8.4.2 para Analógico. 3. El transmisor CON COMPARTIMIENTOS debe recibirse instalado
en la cámara del MLG (medidor de nivel magnético). La instalación típica emplea un soporte de montaje o abrazaderas de manguera para asegurar la fijación del transmisor CON COMPARTIMIENTOS al MLG. Comuníquese con el fabricante de MLG para obtener detalles sobre la instalación.
6.4 Montaje
El método de montaje del transmisor depende del MLG en el que se esté empleando. El montaje típico del transmisor CON COMPARTIMIENTOS es directamente al MLG.
Fig. 7: Montaje del transmisor CON COMPARTIMIENTOS, brida inferior
PrecauciónAl montar el transmisor de nivel a un MLG, se debe mantener un espaciado mínimo de 5 pulgadas entre el cabezal de la carcasa y la barrera de presión. La carcasa y la barrera de presión se identifican en la siguiente representación.
PrecauciónNo se debe superar la recomendación de temperatura ambiente de Ta= -40 °C (-40 °F) a 71 °C (160 °F), como consecuencia del montaje del transmisor de nivel al MLG y la exposición a la temperatura del proceso.
Montaje directoEn la mayoría de las aplicaciones, el transmisor CON COMPARTIMIENTOS se puede montar directamente al MLG mediante abrazaderas de manguera. Consulte al fabricante de MLG para obtener más detalles.
Level Plus® CON COMPARTIMIENTOSManual de funcionamiento
I 13 I
Fig. 10: Montaje del transmisor CON COMPARTIMIENTOS, bridas superior e inferior
(Circle one)
PressureBarrier
ElectronicHead
4 mA or 20 mA
Setpoint
Order LengthStandard
(Circle one)4 mA or 20 mA
Setpoint
74 mm (2.9 in.)Standard
74 mm (2.9 in.)
54 mm (2.1 in.)
114 mm(4.5 in.)
145 mm(5.7 in.)
127 mm(5 in.)Level Plus
7. Conexiones eléctricas
7.1 Información básica
Una típica conexión intrínsecamente segura para un transmisor Level Plus® CON COMPARTIMIENTOS incluye barreras de seguridad de protección, un suministro de energía y un dispositivo de lectura o monitoreo. Consulte la información de la agencia en el capítulo 13.
Una típica conexión resistente a explosiones/ignífuga para un transmisor Level Plus® CON COMPARTIMIENTOS incluye un suministro de energía y un dispositivo de lectura o monitoreo. Todo el cableado se encuentra en un conducto aprobado con aislamiento, según se especifique en el código eléctrico local. Consulte la Información de la agencia en el capítulo 13.
7.2 Recomendaciones de seguridad
Asegúrese de: 1. Respetar siempre los códigos de electricidad nacionales y locales
aplicables y observar la polaridad cuando haga conexiones eléctricas. 2. Nunca realizar conexiones eléctricas al transmisor CON
COMPARTIMIENTOS con la energía conectada. 3. Asegúrese de que no haya alambres de cable sueltos o que
sobresalgan de la conexión del bloque de terminales y que pudieran hacer cortocircuito y ocasionar problemas.
4. Asegúrese de que no haya alambres de cables ni blindaje en contacto con la carcasa del módulo electrónico.
5. La carcasa del módulo electrónico se conecta a tierra a través de circuitos internos y está eléctricamente aislada de la carcasa resistente a explosiones.
7.3 Topologías industriales
Hay cuatro topologías, que se describen e ilustran a continuación. Sin embargo, MTS no recomienda la topología de cadena margarita.
De punto a puntoLa topología de punto a punto está compuesta por un solo dispositivo en el circuito, como se muestra en la Fig. 8. Esta topología no suele utilizarse con una red en bus, ya que esta no se beneficia al colocar múltiples dispositivos en bucle.
PLC
Fig. 8: Topología de punto a punto
Bus con engranaje de espuelaLa topología de bus con engranaje de espuela tiene un cable troncal principal que conecta cada dispositivo a través de su propio engranaje con una caja de conexiones, según se muestra en la Fig. 9. Las topologías de espuela y de árbol también se pueden usar juntas para formar una topología híbrida.
Fig. 9: Topología de bus con engranaje de espuela
PLC
Level Plus® CON COMPARTIMIENTOSManual de funcionamiento
I 14 I
Alineación de árbolLa topología de árbol es muy similar a la topología de espuela, con la diferencia de que la primera tiene una caja de empalme común para todos los transmisores, como se muestra en la Fig. 11. Las topologías de espuela y de árbol también se pueden usar juntas para formar una topología híbrida.
Fig. 11: Topología de árbol
PLC
Cadena margaritaLa topología de cadena margarita emplea un único cable que se conecta a todos los transmisores, con el cable interconectado en cada dispositivo de campo. Al usar esta topología, asegúrese de que el cableado permita que un transmisor pueda desconectarse sin desconectar el circuito completo, como se muestra en la Fig. 12. MTS no sugiere usar la topología de cadena margarita.
Fig. 12: Topología de cadena margarita
PLC
Fig. 13: Instalación del conducto eléctrico
Tabla 2: Especificaciones y parámetros de cables
7.4 Recomendaciones de cables
Consulte la “Tabla 2” a continuación para los requisitos generales de tipos de cable para el transmisor Level Plus® CON COMPARTIMIENTOS.
Especificaciones de cable
7.5 Conducto eléctrico
Parámetro EspecificacionesTamaño mínimo de cable
Ø 0.51…1.6 mm (24…14 AWG)
Tipo de cableDe par individual blindado o de par múltiple con blindaje general; mínimo de 0.25 mm (0.010 in) de grosor del aislamiento
Capacitancia Menos de 98 pF/m (30 pF/ft)
AVISO
1. Apriete la cubierta de la carcasa (tanto la cubierta frontal como la trasera, en caso de cavidad doble) hasta que tope con la junta toroidal.
2. Use únicamente la entrada de los conductos laterales. 3. En áreas de mucha humedad, use el acople de sellado de conductos
tipo respiradero de drenaje para minimizar la intrusión de humedad. 4. Para instalaciones en divisiones, se requiere un sello de conducto
aprobado a una proximidad máxima de 457 mm (18 in) de la carcasa. 5. Para instalaciones en zonas, se requiere un sello de conducto
aprobado a una proximidad máxima de 50 mm (2 in) de la carcasa.
Conduit sealing fitting
NPT or BSPP FittingDo not over-tightencompression fitting!
Interface float(ordered
separately)
Product float(ordered
separately)
View shown withcover removed
Plugged entryDo not use(see notes)
3/4 NPT or M20 conduit accessUse NPT conduit fitting only!
Conduit(flexible or rigid)
Conduit fromcontrol room
Level Plus®
Do not remove cover with circuit energized in hazardous locations!
Follow safe work procedures.
Level Plus® CON COMPARTIMIENTOSManual de funcionamiento
I 15 I
7.6 Conexión a tierra
7.6.1 Conexión segura a tierra
Advertencia:Conectar el transmisor a tierra a través de una conexión de conducto roscado no cumple con los requisitos de seguridad de conexión a tierra del sensor.
Existen dos métodos para proporcionar una conexión a tierra del sistema electrónico. Cualquiera de los métodos debe dar como resultado una resistencia de menos de 1 Ohm. Consulte la “Tabla 3” para obtener referencias de barreras de seguridad.
• Instale una conexión a tierra a través del conducto y conéctela directamente a la lengüeta de conexión a tierra ubicada dentro de la carcasa.
• Instale una conexión a tierra directamente a la lengüeta de conexión a tierra ubicada en la parte externa de la carcasa.
7.6.2 Conexión a tierra de blindaje
Advertencia:La conexión a tierra del blindaje no cumple con los requisitos de seguridad de conexión a tierra del sensor.
El desempeño del sensor en cuanto a inmunidad ante fuentes externas de picos de tensión, explosión, RF, emisiones radiadas y otros ruidos depende de una buena conexión a tierra para el blindaje del cable de comunicaciones. El blindaje del cable de comunicaciones debe ser de tipo trenzado y conectarse a la lengüeta de tierra interna de la carcasa del sensor.
Se extiende en un conducto metálico continuoCuando se instala dentro de un conducto metálico continuo dedicado, el conducto proporciona un nivel de protección blindada contra interferencias externas y un nivel de conexión a tierra para la carcasa del sensor. En este caso un cable blindado tipo aluminio con un cable de drenaje conectado a la lengüeta de tierra interna puede ser suficiente. Compartir el conducto metálico con otros cables resultará en una pérdida de eficacia en el desempeño del cable de comunicación y en una posible degradación en el desempeño del sensor. En este caso se recomienda un cable blindado tipo trenzado conectado a la lengüeta de tierra interna. En todos los casos, acoplar en paralelo el cable de comunicaciones con cualquier cable que genere ruidos dentro de un conducto o con cables que generen ruidos cerca del conducto puede degradar el desempeño del sensor.
Se extiende sin un conductoEn algunas aplicaciones poco frecuentes, o cuando no es necesaria la seguridad, es posible que no haya un conducto metálico. El blindaje del cable de comunicaciones debe ser de tipo trenzado y conectarse a la lengüeta de tierra interna de la carcasa del sensor. Alternativamente, se puede usar una glándula para cable aprobada por EMC para la conexión a tierra del blindaje. Comuníquese con MTS para obtener información antes de usar una de estas glándulas para cable.
NECLas corrientes no deseadas (circuitos a tierra) constituyen una violación de NEC y un peligro para la seguridad.
7.7 Barreras de seguridad
Consulte la Tabla 3 para obtener los parámetros de entidad y la Tabla 4 para obtener ejemplos de barreras de seguridad.
Parámetros de entidad
Suministro digital(1 por LT)
Ui = 28 V CC
Ii = 100 mA
Ci = 0.0 µF
Li = O mH
Pi = 700 mW
Comunicación digital(2 por LT)
Ui = 8.6 V CC
Ii = 10 mA
Ci = 0.0 µF
Li = 0.0 mH
Pi = 21.5 mW
Analógico(1 por circuito)
Ui = 28 V CC
Ii = 120 mA
Ci = 0 µF
Li = 5 µH
Pi = 840 mW
Tabla 3: Referencias de parámetros de entidad de la barrera de seguridad
Tabla 4: Referencias de parámetros de entidad de la barrera de seguridad
Proveedor STAHL STAHL STAHL
Tipo9001/01-280-100-101
9001/51-280-110-141
9001/01-086-010-101
Voltaje máximo 28 V CC 28 V CC 8.6 V CCCorriente máxima(cada canal) 100 mA 110 mA 10 mA
Potencia máxima(cada canal) 700 mW 770 mW 21.5 mW
Cantidad de canales 1 1 1
Interfaz Modbus/DDA HART® Modbus/DDA
Level Plus® CON COMPARTIMIENTOSManual de funcionamiento
I 16 I
8. Puesta en servicio
8.1 Capacitación
La puesta en servicio solo debe ser realizada por personal de servicio calificado de conformidad con IEC 60079-14 y las reglamentaciones locales, o por técnicos de servicio capacitados por MTS. MTS ofrece capacitación para la instalación, puesta en servicio, mantenimiento y reparación a través de la web o en persona. MTS también ofrece servicios directos de fábrica para estas mismas funciones. Comuníquese con MTS para hablar sobre capacitación o servicios directos de fábrica antes de empezar.
8.2 Herramientas
• Pinzas tipo Channel-lock• Convertidor RS485 a USB (pieza de MTS n.º 380114)
[Modbus y DDA]• PC con Windows• Fuente de alimentación con regulación lineal• Software de configuración de MTS• Convertidor HART® a USB (pieza de MTS n.º 380068)
8.3 Software de configuración
MTS ofrece software de configuración que se envía con el transmisor de nivel y que también está disponible para descargar desde www.mtssensors.com. El software de configuración se debe usar para la instalación, puesta en servicio y solución de problemas. Para obtener más detalles sobre cómo usar el software de configuración, consulte el Manual de la interfaz de Modbus (pieza de MTS n.º 551700), el Manual de la interfaz de DDA (pieza de MTS n.º 551701) y el Manual de la interfaz de HART® (pieza de MTS n.º 551702).
8.4 Pasos para la puesta en servicio
8.4.1 Modbus o DDA
1. Consulte la Sección 4.3 antes de empezar. 2. Retire el transmisor de nivel del contenedor de envío. 3. Móntelo en el MLG y pruebe la unidad con un flotador del MLG. 4. Conecte la energía, el convertidor RS485 a USB y la PC. 5. Abra el software de configuración de MTS. 6. Establezca la comunicación. 7. Para la interfaz DDA: configure la dirección. Predeterminada 192. 8. Para la interfaz Modbus: configure la dirección
(dirección predeterminada 247). 9. Desconecte la electricidad y la comunicación.
10. Instalación completa en la Sección 6.4. 11. Pídale a un técnico calificado que realice una medición manual.
Introduzca la medición manual en el software de configuración de MTS y realice la calibración.
12. Almacene todas las configuraciones como copia de respaldo según el nombre de la planta y el número del tanque.
8.4.2 HART®
1. Consulte la Sección 4.3 antes de empezar. 2. Retire el transmisor de nivel del contenedor de envío. 3. Móntelo en el MLG y pruebe con un flotador del MLG. 4. Conecte la energía, el convertidor HART® a USB y la PC. 5. Abra el software de configuración de MTS. 6. Establezca la comunicación. 7. Configure/actualice los puntos de referencia de 4 y 20 mA. 8. Desconecte la electricidad y la comunicación. 9. Instalación completa en la Sección 6.4.
10. Pídale a un técnico calificado que realice una medición manual. Introduzca la medición manual en el software de configuración de MTS y realice la calibración.
11 Almacene todas las configuraciones como copia de respaldo según el nombre de la planta y el número del tanque.
AVISO
Para obtener detalles adicionales, consulte el Manual de la interfaz de Modbus (pieza de MTS n.º 551700), el Manual de la interfaz de DDA (pieza de MTS n.º 551701) y el Manual de la interfaz de HART® (pieza de MTS n.º 551702).
Level Plus® CON COMPARTIMIENTOSManual de funcionamiento
I 17 I
9. Mantenimiento
9.1 Capacitación
El mantenimiento solo debe ser realizado por personal de servicio calificado de conformidad con IEC 60079-14 y las reglamentaciones locales, o por técnicos de servicio capacitados por MTS. MTS ofrece capacitación para la instalación, puesta en servicio, mantenimiento y reparación a través de la web o en persona. MTS también ofrece servicios directos de fábrica para estas mismas funciones. Comuníquese con MTS para hablar sobre capacitación o servicios directos de fábrica antes de empezar.
9.2 Herramientas
• Pinzas tipo Channel-lock• Destornillador con cabezal común y destornillador plano
9.3 Inspección
A continuación encontrará algunos elementos que deben inspeccionarse de forma regular para garantizar que el transmisor de nivel y el entorno circundante estén en condiciones de funcionamiento óptimas.
• La etiqueta de área peligrosa está adherida y legible• La aprobación de área peligrosa es correcta para la instalación• No hay modificaciones no autorizadas visibles• Las conexiones eléctricas están debidamente ajustadas• El estado de la junta toroidal de la carcasa es satisfactorio• No ingresa agua (polvo blanco)• No hay daños visibles a los cables• El sellado del conducto o la glándula para cable es satisfactorio• La conexión a tierra es satisfactoria• Los hilos de la carcasa de cavidad doble o individual no están dañados• Ni la carcasa ni la junta toroidal están dañadas ni quebradas• No hay corrosión en piezas visibles• Las placas de circuito impreso están limpias y sin daños
9.4 Mantenimiento preventivo
Los transmisores de nivel Level Plus® generalmente no requieren mantenimiento preventivo, pero pueden requerirlo según la aplicación. Para aplicaciones de fines generales en las que no hay acumulación potencial en la manguera flexible o en el flotador, no hay necesidad de mantenimiento preventivo, aunque se recomienda hacer inspecciones de rutina. Para aplicaciones de servicio intensivo en las que hay una acumulación potencial en la manguera flexible o en el flotador, se requiere un mantenimiento preventivo.
10. Reparación
10.1 Política de autorización de devolución de material (RMA, por sus siglas en inglés)
Todos los transmisores Level Plus® tienen una garantía limitada de dos años a partir de la fecha de envío desde la fábrica. Todas las devoluciones de transmisores deben estar obligatoriamente acompañadas de un número de autorización de devolución de material (RMA, por sus siglas en inglés). Todas las unidades usadas en un proceso deben limpiarse en conformidad con los estándares de la OSHA antes de devolverlas a la fábrica. Además, una hoja de datos de seguridad del material (MSDS, por sus siglas en inglés) debe acompañar al transmisor que se usó en cualquier proceso.
10.2 Capacitación
La reparación solo debe ser realizada por personal de servicio calificado de conformidad con IEC 60079-14 y las reglamentaciones locales, o por técnicos de servicio capacitados por MTS. MTS ofrece capacitación para la instalación, puesta en servicio, mantenimiento y reparación a través de la web o en persona. MTS también ofrece servicios directos de fábrica para estas mismas funciones. Comuníquese con MTS para hablar sobre capacitación o servicios directos de fábrica antes de empezar.
10.3 Herramientas
• Pinzas tipo Channel-lock• Destornillador con punta Phillips y destornillador• Destornillador con cabezal común y destornillador plano• Convertidor RS485 a USB (pieza de MTS n.º 380114) [Modbus y DDA]• PC con Windows• Fuente de alimentación con regulación lineal• Convertidor HART® a USB (pieza de MTS n.º 380068)
Importante:Comuníquese con Soporte Técnico o con Atención al Cliente para recibir asistencia si sospecha que el transmisor no funciona correctamente. Soporte Técnico puede ayudarlo con información relativa a la solución de problemas, la sustitución de piezas y la autorización de devolución de material (RMA, por sus siglas en inglés) si es necesario.
Level Plus® CON COMPARTIMIENTOSManual de funcionamiento
I 18 I
10.4 Solución de problemas
10.5 Software de configuración
MTS ofrece software de configuración que se envía con el transmisor de nivel y que también está disponible para descargar desde www.mtssensors.com. Para obtener más detalles sobre cómo usar el software de configuración (para la instalación, puesta en servicio y solución de problemas), consulte el Manual de la interfaz de Modbus (pieza de MTS n.º 551700), el Manual de la interfaz de DDA (pieza de MTS n.º 551701) y el Manual de la interfaz de HART® (pieza de MTS n.º 551702).
Síntoma Posible causa AcciónNo hay comunicación con el transmisor
No hay electricidad Revisar el voltaje en el transmisor
Cableado incorrecto Plano de instalación de referencia, capítulo 13
Dirección equivocada El ajuste predeterminado de DDA es ‘192 ’, el ajuste predeterminado de Modbus es ‘247 ’
Software incorrecto Confirme que el software sea correcto
Protocolo incorrecto Confirme que el software y el transmisor tengan el mismo protocolo
Error deimán faltanteo alarma de salida
No se reconoce el flotador
Confirme que el flotador esté en su sitio
El flotador está en una zona muerta
Eleve el flotador para ver si el error desaparece
Número erróneo de flotadores seleccionado
Confirme que la cantidad de flotadores en el transmisor y la cantidad de flotadores que el transmisor intenta verificar sea la misma.
Error de nivel de desenca-denamiento
Se debe ajustar la ganancia
Consultar a la fábrica
Daño en SE Consultar a la fábrica
El nivel de desencadenamiento mínimo es demasiado alto
Consultar a la fábrica
Modo de cálculo de volumen
No se ingresó tabla de ajuste
Ingresar tabla de ajuste
Nivel fuera del rango de la tabla de ajuste
Ingresar puntos adicionales en la tabla de ajuste
Tabla de ajuste incorrecta
Verificar las entradas de valores
Error de VCF No se ingresó tabla VCF
Ingresar tabla VCF
Tabla VCF incorrecta Verificar las entradas de valores de VCF
Tabla 5: Referencia de solución de problemas
11. Piezas de repuesto
A continuación, se encuentra la lista de piezas de repuesto de la Serie LP para la pantalla, el módulo electrónico, el elemento sensor y la manguera flexible. Comuníquese con Soporte Técnico de MTS si tiene cualquier pregunta.
12. Interfaz
El transmisor CON COMPARTIMIENTOS está disponible con múltiples opciones de salida, incluidas Modbus, DDA y HART®. Este Manual de funcionamiento e instalación incluye todas estas salidas. Cada salida tiene un Manual de interfaz especializado, que debería ser consultado para obtener información adicional sobre la salida específica. Para SIL, consulte el Manual de seguridad de SIL, pieza de MTS n.º 551851.
12.1 Modbus
MTS ofrece Modbus RTU en una red semidúplex RS485. Para obtener información adicional, consulte el Manual de la interfaz de Modbus (pieza de MTS n.º 551700).
12.2 DDA
MTS ofrece DDA (acceso digital directo) en una red semidúplex RS485. Para obtener información adicional, consulte el Manual de la interfaz de DDA, pieza de MTS n.º 551701.
12.3 HART®
MTS ofrece HART® en una señal de 4 a 20 mA. Para obtener información adicional, consulte el Manual de la interfaz de HART®, pieza de MTS n.º 551702.
Elemento sensorCambie el tercer dígito del número de modelo de T a E. Por ejemplo, el elemento sensor para el número de modelo LPTME1N11B5FFIAU50000S es LPEME1N11B5FFIAU50000S.
Manguera flexibleCambie el tercer dígito del número de modelo de T a P. Por ejemplo, la manguera flexible de reemplazo para el número de modelo LPTME1N11B5FFIAU50000S es LPPME1N11B5FFIAU50000S.
Pieza de repuesto Número de pieza
Pantalla 254732
Salida Carcasa Número de pieza
HART® bucle individual A, B, C, D, E 254731-1
HART® bucle doble A, B, C, D, E 254731-2
Modbus A, B, C, D, E 254731-3
DDA A, B, C, D, E 254731-4
HART® bucle individual L 254731-5
HART® bucle doble L 254731-6
Modbus L 254731-7
DDA L 254731-8
SIL bucle individual A, B, C, D, E 254850-1
SIL bucle doble A, B, C, D, E 254850-2
SIL bucle individual L 254850-5
SIL bucle doble L 254850-6
Level Plus® CON COMPARTIMIENTOSManual de funcionamiento
I 19 I
Organismo acreditado
Método de protección Clasificación Estándar
C = CEC I = Seguridad intrínseca Clase I, división 1, grupos ABCD T4Clase I, zona 0/1, Ex ia IIC T4Ta = -50 °C a 71 °C IP65
CAN C22.2 No. 157-92:2012CSA C22.2 No. 1010.1:2004CAN/CSA C22.2 No. 60079-0:2011CAN/CSA C22.2 No. 60079-11:2014CAN/CSA C22.2 No. 60529:2005
F = A prueba de explosión/ignífugo
Clase I, división 1, grupos BCD T6…T3Ex db IIB+H2 T6…T3 Ga/GbTa = -40 °C a 71 °C IP65
CSA C22.2 No. 0.4-04:R2013CSA C22.2 No. 0.5:R2012CSA C22.2 No. 0-10:R2015CSA C22.2 No. 30:R2012CAN/CSA C22.2 No. 60079-0:2015CAN/CSA C22.2 No. 60079-1:2016CAN/CSA 622.2 N.o. 60079-26:2016CAN/CSA C22.2 No. 61010.1:2012CSA C22.2 No. 60529:R2010
E = ATEX I = Seguridad intrínseca II 1/2 G Ex ia IIC T4Ta = -50 °C a 71 °C IP65
EN 60079-0:2012EN 60079-11:2012EN 60529:1991 + A1:2000
F = Ignífugo II 1/2 G Ex db IIB+H2 T6…T3 Ga/GbTa = -40 °C a 71 °C IP65
EN 60079-0:2012+A11:2013EN 60079-1:2014EN 60079-26:2015EN 60529:1991 + A2:2013
F = NEC I = Seguridad intrínseca Clase I, división 1, grupos ABCD T4Clase I, zona 0/1, AEx ia IIC T4Ta = -50 °C a 71 °C IP65
FM 3600:2011FM 3610:2010FM 3810:2005ANSI/ISA 60079-0:2013ANSI/ISA 60079-11:2014ANSI/IEC 60529:2004
F = A prueba de explosión/Ignífuga
Clase I, división 1, grupos ABCD T6…T3Clase I, división 1, grupos BCD T6…T3Clase I, zona 0/1, AEx db IIB+H2 T6…T3 Ga/GbTa = -40 °C a 71 °C IP65
FM 3600:2011FM 3615:2006FM 3810:2005ANSI/ISA 60079-0:2013ANSI/UL 60079-1:2015ANSI/UL 60079-26:2017ANSI/IEC 60529:2004
I = IEC I = Seguridad intrínseca Ex ia IIC T4 Ga/GbTa = -50 °C a 71 °C IP65
IEC 60079-0:2011IEC 60079-11:2011
F = Ignífugo Ex db IIB+H2 T6…T3 Ga/GbTa = -40 °C a 71 °C IP65
IEC 60079-0:2007-10IEC 60079-1:2007-04IEC 60079-26:2014-10IEC 60529:2013
B = INMETRO I = Seguridad intrínseca Ex ia IIC T4 Ga/GbTa = -50 °C a 71 °C IP65
ABNT NBR IEC 60079-0ABNT NBR IEC 60079-11ABNT NBR IEC 60529
F = Ignífugo Ex db IIB+H2 T6…T3 Ga/GbTa = -40 °C a 71 °C IP65
ABNT NBR IEC 60079-0ABNT NBR IEC 60079-1ABNT NBR IEC 60079-26ABNT NBR IEC 60529
(continúa en la página siguiente…)
13. Información de la agencia
13.1 Resumen de aprobaciones
El organismo de notificación se designa mediante el decimotercer dígito del número de modelo y el método de protección en el decimocuarto. Estos dos dígitos del número de modelo especifican la aprobación de área potencialmente peligrosa que se proporciona con el transmisor de nivel seleccionado. A continuación se muestra la información de aprobación detallada para las aprobaciones NEC, CEC, IEC y ATEX. Además, MTS cuenta con aprobaciones bajo INMETRO, NEPSI, KC, CCoE y CML (Japón). Comuníquese con MTS si tiene cualquier pregunta acerca de la aprobación necesaria de protección contra riesgos.
Tabla 6: Aprobaciones de agencia, parte 1
Level Plus® CON COMPARTIMIENTOSManual de funcionamiento
I 20 I
Tabla 7: Aprobaciones de agencia, parte 2
Organismo acreditado
Método de protección Clasificación Estándar
N = NEPSI I = Seguridad intrínseca Ex ia IIC T4 Ga/GbTa = -50 °C a 71 °C IP65
GB 3836.1-2010GB 3836.4-2010GB 3836.20-2010
F = Ignífugo Ex db IIB+H2 T6…T3 Ga/GbTa = -40 °C a 71 °C IP65
GB 3836.1-2010GB 3836.2-2010
C = CCoE/PESO
I = Seguridad intrínseca Ex ia IIC T4 Ga/GbTa = -50 °C a 71 °C IP65
IEC 60079-0:2011IEC 60079-11:2011Reglas de petróleo 2002
F = Ignífugo Ex db IIB+H2 T6…T3 Ga/GbTa = -40 °C a 71 °C IP65
IEC 60079-0:2007-10IEC 60079-1:2007-04IEC 60079-26:2014-10IEC 60529:2013Reglas de petróleo 2002
T = CML/TIIS I = Seguridad intrínseca Ex ia IIC T4 Ga/GbTa = -50 °C a 71 °C IP65
IEC 60079-0:2011IEC 60079-11:2011
F = Ignífugo Ex db IIB+H2 T6…T3 Ga/GbTa = -40 °C a 71 °C IP65
IEC 60079-0:2007-10IEC 60079-1:2007-04IEC 60079-26:2014-10IEC 60529:2013
K = KC I = Seguridad intrínseca PENDIENTE PENDIENTEF = Ignífugo PENDIENTE PENDIENTE
Level Plus® CON COMPARTIMIENTOSManual de funcionamiento
I 21 I
13.2 Certificados
Copias para descargar de todos los certificados locales se pueden encontrar en www.mtssensors.com y se pueden descargar en la página de inicio específica del producto. Si tiene alguna dificultad para obtener los certificados desde la web, comuníquese con Soporte Técnico de MTS y ellos se los enviarán de forma electrónica.
13.3 FM (NEC)
13.3.1 Seguridad intrínseca
13.3.1.1 Condiciones específicas para un uso seguro 1. La carcasa del aparato contiene aluminio y se considera que esto
constituye un riesgo potencial de ignición por impacto o fricción. Se debe tener cuidado durante la instalación y el uso para evitar impactos o fricción. (cuando se instala con aprobación de Ga)
2. La temperatura ambiente máxima permitida del transmisor de nivel digital/analógico Level Plus® es de 71 ºC. Para evitar los efectos producidos por la temperatura del proceso y otros efectos térmicos, se debe tener cuidado para garantizar que el ambiente circundante y el ambiente dentro de la carcasa del transmisor no supere los 71 °C
3. Algunos modelos contienen piezas no metálicas en la carcasa. Para evitar el riesgo de chispas electrostáticas sobre la superficie no metálica, la superficie se debe limpiar solo con un paño húmedo.
13.3.1.2 Etiquetas
1
1
2
2
A A
B B
REV ECO # DESCRIPTION
TITLE
SIZE DWG NO. REV
PRODUCT LINESCALE:
BY DATE
SHEET OF
UNLESS OTHERWISE SPECIFIEDTOLERANCES
0 PLACESMM
1 PLACEMM
ANGLES
0.5 0.1
- THREAD DEPTHS ARE TO MIN. FULL THDS- DRILL DEPTHS ARE TO FULL DIA.- REMOVE BURRS AND SHARP EDGES- DO NOT SCALE PRINT- MACHINED SURFACE FINISH 3.2uM [125 uIn]
PROPRIETARY DATATHE INFORMATION AND DESIGN(S) DISCLOSEDHEREIN ARE THE PROPERTY OF MTS SYSTEMSCORPORATION AND MAY NOT BE USED,REPRODUCED OR DISCLOSED IN ANY FORMEXCEPT AS GRANTED IN WRITING BY MTSSYSTEMS CORPORATION. THIS RESTRICTIONEXCLUDES INFORMATION THAT IS IN THE PUBLIC DOMAIN OR WAS LEGITIMATELY IN THEPRIOR POSSESSION OF THE RECIPIENT.
mMTS SYSTEMS CORPORATIONSENSORS DIVISION3001 SHELDON DRIVE, CARY, NC 27513
METRIC
FIRST ANGLE 551629-1 B
1 2
DRAWN BY: NJ
A NJ
***NO REVISIONS SHALL BE MADE WITHOUT THE NOTIFICATION TO APPROVAL AGENCY(S).***
INTRINSICALLY SAFECL. I, Div. 1, GR. ABCDCL. I, Zone 0/1, AEx ia IIC T4Ta = -50°C to +71°C ; IP65when connected in accordance with FM approved installa on drawing # 651543-1
WARNING: REFER TO INSTALLATION DRAWING FOR CAUTION/WARNINGS
Model No: Serial No: Date :
MTS Systems CorporationSensors Division3001 Sheldon Dr.Cary, NC 27513
Level Plus Transmitter
USE MTS LOGO ARTWORK
10 POINT SIZE
8 POINT TEXT SIZE
4.5 POINT TEXT SIZE
MTS TO PRINTMODEL NO.SERIAL NO.
DATE CODE.
ENTITY PARAMETERS:SEE PRINT REFERENCE CHART
4.5 POINT TEXT SIZE
FM APPROVED
USE FM LOGO ARTWORK
US
LEVEL
1:1
7570 RELEASE TO PRODUCTION
(ACP) LABEL, LP, IS US - DIGITAL
NOTES:1. STANDARD LETTERING UNIVERS 55 OR ITC GARAMOND BOOK.2. DIMENSIONS IN BRACKETS [ ] ARE IN INCHES.3. MATERIAL: 3M 7883 METALLIZED POLYESTER FOIL W/GAS RESISTANT INK.
P/N 551629-1 Rev B
10/24/14
86.30 [3.40]
1.78 [.07]
34.69 [1.37]
1.78 [.07]
69.85 [2.75]
R3.30 [.13]
28.70 [1.13]
15.80 [.62]
12/02/14NJB 7847 IP RATING WAS 66
®
Fig. 14: Etiqueta FM de seguridad intrínseca, Modbus o DDA, carcasa NEMA
Fig. 15: Etiqueta FM de seguridad intrínseca, HART®, carcasa NEMA
Fig. 16: Etiqueta FM de seguridad intrínseca, Modbus o DDA, carcasa con cavidad individual o doble
Fig. 17: Etiqueta FM de seguridad intrínseca, HART®, carcasa con cavidad individual o doble
1
1
2
2
A A
B B
TITLE
SIZE DWG NO. REV
PRODUCT LINESCALE: SHEET OF
UNLESS OTHERWISE SPECIFIEDTOLERANCES
0 PLACESMM
1 PLACEMM
ANGLES� � �� 0.5 � 0.1
- THREAD DEPTHS ARE TO MIN. FULL THDS- DRILL DEPTHS ARE TO FULL DIA.- REMOVE BURRS AND SHARP EDGES- DO NOT SCALE PRINT- MACHINED SURFACE FINISH 3.2uM [125 uIn]
PROPRIETARY DATATHE INFORMATION AND DESIGN(S) DISCLOSEDHEREIN ARE THE PROPERTY OF MTS SYSTEMSCORPORATION AND MAY NOT BE USED,REPRODUCED OR DISCLOSED IN ANY FORMEXCEPT AS GRANTED IN WRITING BY MTSSYSTEMS CORPORATION. THIS RESTRICTIONEXCLUDES INFORMATION THAT IS IN THE PUBLIC DOMAIN OR WAS LEGITIMATELY IN THEPRIOR POSSESSION OF THE RECIPIENT.
mMTS SYSTEMS CORPORATIONSENSORS DIVISION3001 SHELDON DRIVE, CARY, NC 27513
METRIC
FIRST ANGLE A 551642- C
1 1
DRAWN BY: NJ
***NO REVISIONS SHALL BE MADE WITHOUT THE NOTIFICATION TO APPROVAL AGENCY(S).***
MTS Systems CorporationSensors Division3001 Sheldon Drive, Cary, N.C. 27513
INTRINSICALLY SAFECL. I, Div. 1, GR. ABCDCL. I, Zone 0/1, AEx ia IIC T4Ta = -50°C TO +71°C ; IP65WARNING: SUBSTITUTION OF COMPONENTS MAY IMPAIR INTRINSIC SAFETYREFER TO INSTALLATION DRAWING FOR CAUTION/WARNINGS
INSTALL PER DRAWING # 651544-1SUPPLY VOLTAGE: 28 VDC
Level Plus Transmitter
35.05 [1.38]
"L1"∆ "L2"
17.53 [.69]
7.5 POINT SIZEMTS TO PRINTMODEL NO.
SERIAL NO./DATE CODE
"D1"
4.0 POINT TEXT SIZE(TYP.)
8.97 [.35] 3.47 [.1
(ACP) LABEL, LP, IS US - ANALOG
FM LOGO ARTWORK4.5 POINT TEXT SIZE
R
FM
USE MTS LOGO ARTWORK14.0 POINT SIZE
LEVEL
1:1
APPROVED
�
P/N 551642-X Rev C
NOTES:1. STANDARD LETTERING UNIVERS 55 OR ITC GARAMOND BOOK.2. MATERIAL TO BE SCREEN PRINTED ALUMINUM WITH SATIN BACKGROUND AND BLACK TEXT OR LASER ETCHED ALUMINUM.3. ∆ INDICATES CRITICAL DIMENSIONS.4. DIMENSIONS IN BRACKETS [ ] ARE IN INCHES5. MATERIAL: .8 [.03] THICK ALUMINUM6. REFER TO TABLE 1 FOR "L1" & "L2" DIMENSIONS.
SEE TABLE 1 FOR DASH #.
TABLE 1DASH
# HOUSING "L1" "L2" "D1"
-1 ADALET85.85 [3.38]
69.85 [2.75]
Ø2.35 [.09]x2
-2LIMATHE
RM65 [2.56]
58 [2.28]
Ø 3.05 [.12] x2
C 8256 ADDED "D1" MS 2/22/17B 7847 IP RATING WAS 66 NJ 12/2/14A 7570 RELEASE FOR PRODUCTION NJ 10/24/14
REV ECO# DESCRIPTION BY DATE
1
1
2
2
A A
B B
TITLE
SIZE DWG NO. REV
PRODUCT LINESCALE: SHEET OF
UNLESS OTHERWISE SPECIFIEDTOLERANCES
0 PLACESMM
1 PLACEMM
ANGLES���� 0.5 � 0.1
- THREAD DEPTHS ARE TO MIN. FULL THDS- DRILL DEPTHS ARE TO FULL DIA.- REMOVE BURRS AND SHARP EDGES- DO NOT SCALE PRINT- MACHINED SURFACE FINISH 3.2uM [125 uIn]
PROPRIETARY DATATHE INFORMATION AND DESIGN(S) DISCLOSEDHEREIN ARE THE PROPERTY OF MTS SYSTEMSCORPORATION AND MAY NOT BE USED,REPRODUCED OR DISCLOSED IN ANY FORMEXCEPT AS GRANTED IN WRITING BY MTSSYSTEMS CORPORATION. THIS RESTRICTIONEXCLUDES INFORMATION THAT IS IN THE PUBLIC DOMAIN OR WAS LEGITIMATELY IN THEPRIOR POSSESSION OF THE RECIPIENT.
mMTS SYSTEMS CORPORATIONSENSORS DIVISION3001 SHELDON DRIVE, CARY, NC 27513
METRIC
FIRST ANGLE A 551634- C
1 1DRAWN BY: NJ
***NO REVISIONS SHALL BE MADE WITHOUT THE NOTIFICATION TO APPROVAL AGENCY(S).***
MTS Systems CorporationSensors Division3001 Sheldon Drive, Cary, N.C. 27513
INTRINSICALLY SAFECL. I, Div. 1, GR. ABCDCL. I, Zone 0/1, AEx ia IIC T4Ta = -50°C TO +71°C ; IP65WARNING: SUBSTITUTION OF COMPONENTS MAY IMPAIR INTRINSIC SAFETYREFER TO INSTALLATION DRAWING FOR CAUTION/WARNINGS
INSTALL PER DRAWING # 651543-1SUPPLY VOLTAGE: 28 VDC
Level Plus Transmitter
35.05 [1.38]
"L1"∆ "L2"
17.53 [.69]
7.5 POINT SIZEMTS TO PRINTMODEL NO.
SERIAL NO./DATE CODE
"D1"
4.0 POINT TEXT SIZE(TYP.)
8.97 [.35] 3.47 [.14]
(ACP) LABEL, LP, IS US - DIGITAL
FM LOGO ARTWORK4.5 POINT TEXT SIZE
R
FM
USE MTS LOGO ARTWORK14.0 POINT SIZE
LEVEL
1:1
NOTES:1. STANDARD LETTERING UNIVERS 55 OR ITC GARAMOND BOOK.2. MATERIAL TO BE SCREEN PRINTED ALUMINUM WITH SATIN BACKGROUND AND BLACK TEXT OR LASER ETCHED ALUMINUM.3. ∆ INDICATES CRITICAL DIMENSIONS.4. DIMENSIONS IN BRACKETS [ ] ARE IN INCHES.5. MATERIAL: .8 [0.03] THICK ALUMINUM6. REFER TO TABLE 1 FOR "L1" & "L2" DIMENSIONS.
APPROVED
�
P/N 551634-X Rev C
SEE TABLE 1 FOR DASH #.
TABLE 1DASH
# HOUSING "L1" "L2" "D1"
-1 ADALET85.85[3.38]
69.85 [2.75]
Ø2.35 [.09]x2
-2 LIMATHERM65
[2.56]58
[2.28]Ø 3.05 [.12] x2
C 8256 ADDED "D1" MS 2/22/1766 SAW GNITAR PI7487B NJ 12/2/14
A 7570 RELEASE FOR PRODUCTION NJ 10/24/14ETADYBNOITPIRCSED#OCEVER
1
1
2
2
A A
B B
REV ECO # DESCRIPTION
TITLE
SIZE DWG NO. REV
PRODUCT LINESCALE:
BY DATE
SHEET OF
UNLESS OTHERWISE SPECIFIEDTOLERANCES
0 PLACESMM
1 PLACEMM
ANGLES
0.5 0.1
- THREAD DEPTHS ARE TO MIN. FULL THDS- DRILL DEPTHS ARE TO FULL DIA.- REMOVE BURRS AND SHARP EDGES- DO NOT SCALE PRINT- MACHINED SURFACE FINISH 3.2uM [125 uIn]
PROPRIETARY DATATHE INFORMATION AND DESIGN(S) DISCLOSEDHEREIN ARE THE PROPERTY OF MTS SYSTEMSCORPORATION AND MAY NOT BE USED,REPRODUCED OR DISCLOSED IN ANY FORMEXCEPT AS GRANTED IN WRITING BY MTSSYSTEMS CORPORATION. THIS RESTRICTIONEXCLUDES INFORMATION THAT IS IN THE PUBLIC DOMAIN OR WAS LEGITIMATELY IN THEPRIOR POSSESSION OF THE RECIPIENT.
mMTS SYSTEMS CORPORATIONSENSORS DIVISION3001 SHELDON DRIVE, CARY, NC 27513
METRIC
FIRST ANGLE 551629-1 B
1 2
DRAWN BY: NJ
A NJ
***NO REVISIONS SHALL BE MADE WITHOUT THE NOTIFICATION TO APPROVAL AGENCY(S).***
INTRINSICALLY SAFECL. I, Div. 1, GR. ABCDCL. I, Zone 0/1, AEx ia IIC T4Ta = -50°C to +71°C ; IP65when connected in accordance with FM approved installa on drawing # 651543-1
WARNING: REFER TO INSTALLATION DRAWING FOR CAUTION/WARNINGS
Model No: Serial No: Date :
MTS Systems CorporationSensors Division3001 Sheldon Dr.Cary, NC 27513
Level Plus Transmitter
USE MTS LOGO ARTWORK
10 POINT SIZE
8 POINT TEXT SIZE
4.5 POINT TEXT SIZE
MTS TO PRINTMODEL NO.SERIAL NO.
DATE CODE.
ENTITY PARAMETERS:SEE PRINT REFERENCE CHART
4.5 POINT TEXT SIZE
FM APPROVED
USE FM LOGO ARTWORK
US
LEVEL
1:1
7570 RELEASE TO PRODUCTION
(ACP) LABEL, LP, IS US - DIGITAL
NOTES:1. STANDARD LETTERING UNIVERS 55 OR ITC GARAMOND BOOK.2. DIMENSIONS IN BRACKETS [ ] ARE IN INCHES.3. MATERIAL: 3M 7883 METALLIZED POLYESTER FOIL W/GAS RESISTANT INK.
P/N 551629-1 Rev B
10/24/14
86.30 [3.40]
1.78 [.07]
34.69 [1.37]
1.78 [.07]
69.85 [2.75]
R3.30 [.13]
28.70 [1.13]
15.80 [.62]
12/02/14NJB 7847 IP RATING WAS 66
®
651544-1
551641-1
Level Plus® CON COMPARTIMIENTOSManual de funcionamiento
I 22 I
13.3.1.3 Plano de instalación
Fig. 18: Diagrama de instalación FM de seguridad intrínseca, Modbus y DDA, página 1
11
22
33
44
55
66
77
88
AA
BB
CC
DD
REV
ECO
#D
ESCR
IPTION
TITLE
SIZED
WG
NO
.R
EV
PRO
DU
CT LIN
ESC
ALE:
BYD
ATE
SHEET
OF
UN
LESS OTH
ERW
ISE SPECIFIED
TOLER
ANC
ES0 PLAC
ESM
M1 PLAC
EM
MAN
GLES
0.5
0.1
- THR
EAD
DEPTH
S ARE TO
MIN
. FULL TH
DS
- DR
ILL DEPTH
S ARE TO
FULL D
IA.
- REM
OV
E BU
RR
S AND
SHAR
P E
DG
ES- D
O N
OT SC
ALE PRIN
T- M
ACH
INED
SUR
FACE
FINISH
3.2uM [125 uIn]
PRO
PRIETAR
Y DATA
THE IN
FOR
MATIO
N AN
D D
ESIG
N(S) D
ISCLO
SEDH
ERE
IN AR
E THE PR
OPER
TY OF M
TS SYSTEMS
CO
RPO
RATIO
N AN
D M
AY NO
T BE USED
,R
EPRO
DU
CED
OR
DISC
LOSED
IN A
NY FO
RM
EXCEPT AS G
RAN
TED IN
WR
ITING
BY MTS
SYSTEMS C
OR
POR
ATIO
N. TH
IS RESTR
ICTIO
NEXC
LUD
ES INFO
RM
ATION
THA
T IS IN TH
E PU
BLIC D
OM
AIN O
R W
AS LEGITIM
ATELY IN TH
EPR
IOR
POSSES
SION
OF TH
E REC
IPIENT.
mM
TS SYSTEMS C
OR
POR
ATION
SENSO
RS D
IVISION
3001 SHELD
ON
DR
IVE, CAR
Y, NC
27513
METRIC
FIRST
ANG
LED
651543-1
1 2
DR
AWN
BY: M
S
***NO
REVISIO
NS SH
ALL BE MAD
E WITH
OU
T THE N
OTIFIC
ATION
TO APPR
OVAL AG
ENC
Y(S).**
G
C 7898 UPDATED TEMPERATURE ON NOTE 12 TO 71 C M
S 2/23/15D 8037 ADDED W
IRING CHART MS 11/3/15
E 8183 ADDED CL I Zone 0/1 MS 8/18/16
F 8256 UPDATED WIRING CHART ON SHEET 2 M
S 1/30/17G 8482 UPDATED BEND RADIUS TO 15" M
S 5/17/18
24 VDC
COMM
ON- >
Rx /Tx+
Rx /Tx-
GROUND
EARTH GROUND(SEE NOTE 4)
EARTH GROUND(SEE NOTE 4)
Rx/Tx-
Rx/Tx+
GND
+24V
SAFETY BARRIER SAFETY BARRIER
SAFETY BARRIER
NO
TES:1.ALL N
ATION
AL AND
LOC
AL CO
DES AN
D R
EGU
LATION
S MU
ST BE ADH
ERED
TO W
HEN
INSTALLIN
G TH
E LEVEL SENSO
R IN
HAZAR
DO
US EN
VIRO
NM
ENTS.
SEAL ALL CO
ND
UITS W
ITHIN
457 MM
(18"). 2.LO
OP C
ABLE MU
ST BE 24 AWG
TO 14 AW
G (.511M
M² to 1.6M
M²)
SHIELD
ED TW
ISTED PAIR
CABLE W
ITH SH
IELD. C
ABLE CAPAC
ITANC
E MU
ST BE LESS TH
AN 30 pF PER
FOO
T (98 pF PER M
). CABLE SH
IELD IS C
ON
NEC
TED TO
SYSTEM G
RO
UN
D IN
NO
N-H
AZARD
OU
S AREA. SEE IN
STALLATION
MAN
UAL FO
R
ADD
ITION
AL CABLE IN
FOR
MATIO
N.
3.THE R
ESISTANC
E BETWEEN
EARTH
GR
OU
ND
AND
THE IN
TRIN
SICALLY SAFE G
RO
UN
D M
UST BE LESS TH
AN 1 O
HM
. 4.TH
E TRAN
SDU
CER
FRAM
E SHALL BE G
RO
UN
DED
TO EAR
TH G
RO
UN
D D
IREC
TLY OR
THR
OU
GH
THE EQ
UIPM
ENT O
N W
HIC
H IT IS M
OU
NTED
. 5. C
ON
TRO
L EQU
IPMEN
T CO
NN
ECTED
TO ASSO
CIATED
APPARATU
S MU
ST N
OT U
SE OR
GEN
ERATE M
OR
E THAN
250 VRM
S OR
VDC
6.ASSOC
IATED APPAR
ATUS M
ANU
FACTU
RER
'S INSTALLATIO
N D
RAW
ING
MU
ST BE FO
LLOW
ED W
HEN
INSTALLIN
G TH
IS EQU
IPMEN
T. 7.O
NLY U
SE NEC
(e.g FM) APPR
OVED
BARR
IERS.
8.ENTITY PAR
AMETER
S: SU
PPLY: Rx/Tx-: R
x/Tx+: U
i = 28VDC
Ui= 8.6V U
i= 8.6V Ii = 100m
A Ii = 10mA Ii = 10m
A C
i = 0 µF Ci = 0 µF C
i = 0 µF Li = 0 µH
Li = 0 µH Li = 0 µH
Pi = 0.7 W Pi= 0.0215 W
P i= 0.0215 W 9.TH
E ENTITY C
ON
CEPT ALLO
WS IN
TERC
ON
NEC
TION
OF IN
TRIN
SICALLY SAFE APPAR
ATUS
WITH
ASSOC
IATED APPAR
ATUS W
HEN
THE FO
LLOW
ING
IS TRU
E: Vm
ax or Ui ≥ Voc, Vt or U
o; Im
ax or Ii ≥ Isc, It or Io; Pm
ax or Pi ≥ Po; C
a ≥ Ci + C
cable; La ≥ Li + Lcable. 10.D
UAL-C
AVITY ENC
LOSU
RES:
CU
STOM
ER C
ON
NEC
TION
S WILL BE M
ADE AT TER
MIN
AL BLOC
K ON
POW
ER SID
E O
F HO
USIN
G (N
OT TO
TERM
INAL BLO
CK O
N IN
TERC
ON
NEC
T BOAR
D).
11.INSTALLATIO
N SH
OU
LD BE IN
ACC
OR
DAN
CE W
ITH AN
SI/ISA RP12.06.01 "IN
STALLATION
OF
INTR
INSIC
ALLY SAFE SYSTEMS FO
R H
AZARD
OU
S (CLASSIFIED
) LOC
ATION
S" AN
D TH
E NATIO
NAL ELEC
TRIC
AL CO
DE (AN
SI/NFPA 70).
12.THE M
AXIMU
M PER
MITTED
AMBIEN
T TEMPER
ATUR
E OF TH
E LEVEL PLUS D
IGITAL/AN
ALOG
LEVEL TR
ANSM
ITTER IS 71 °C
. TO AVO
ID TH
E EFFECTS O
F PRO
CESS TEM
PERATU
RE AN
D
OTH
ER TH
ERM
AL EFFECTS C
ARE SH
ALL BE TAKEN TO
ENSU
RE TH
E SUR
RO
UN
DIN
G AM
BIENT
AND
THE AM
BIENT IN
SIDE TH
E TRAN
SMITTER
HO
USIN
G D
OES N
OT EXC
EED 71°C
13.CAU
TION
: FLEXIBLE GAU
GES H
AVE A MIN
IMU
M BEN
D R
ADIU
S OF 381M
M(15")
14.WAR
NIN
G: TH
E APPARATU
S ENC
LOSU
RE C
ON
TAINS ALU
MIN
UM
AND
IS CO
NSID
ERED
TO C
ON
STITUTE A PO
TENTIAL R
ISK OF IG
NITIO
N BY IM
PACT O
R FR
ICTIO
N. C
ARE M
UST BE TAKEN
IN
TO AC
CO
UN
T DU
RIN
G IN
STALLATION
AND
USE TO
PREVEN
T IMPAC
T OR
FRIC
TION
15.WAR
NIN
G: SU
BSTITUTIO
N O
F CO
MPO
NEN
TS MAY IM
PAIR IN
TRIN
SIC SAFETY.
16.WAR
NIN
G: TO
PREVEN
T IGN
ITION
OF FLAM
MABLE O
R C
OM
BUSTIBLE ATM
OSPH
ERES,
DISC
ON
NEC
T POW
ER BEFO
RE SER
VICIN
G
17.WAR
NIN
G: TH
E EQU
IPMEN
T CO
NTAIN
S NO
N-M
ETALLIC EN
CLO
SUR
E PARTS, TO
PREVEN
T TH
E RISK O
F ELECTR
OSTATIC
SPARKIN
G. TH
E NO
N-M
ETALLIC SU
RFAC
E SHO
ULD
ON
LY BE C
LEANED
WITH
A DAM
P CLO
TH.
NON HAZARDOUS LOCATIONHAZARDOUS LOCATION
AGEN
CY C
ON
TRO
LLED D
RAW
ING
(US). N
O C
HAN
GES W
ITHO
UT PR
IOR
AGEN
CY APPR
OVAL
EARTH TERMINAL
(ACP) INSTALLATIN DWG LP DIGITAL
INTRINSICALLY SAFE FOR US
LEVEL
FM
APPROVED US
N/A
INTRINSICALLY SAFECL. I, DIV. 1, GR. ABCDCL. I Zone 0/1 AEx ia IIC T4 Ta =
-50 to 71°C ; IP65
Level Plus® CON COMPARTIMIENTOSManual de funcionamiento
I 23 I
Fig. 19: Diagrama de instalación FM de seguridad intrínseca, Modbus y DDA, página 2
DETAIL ASCALE 1.60 : 1
DETAIL CSCALE 3 : 1
DETAIL DSCALE 1.2
DETAIL ESCALE 1 : 1
A
C
D
E
11
22
33
44
55
66
77
88
AA
BB
CC
DD
REV
ECO
#D
ESCR
IPTION
TITLE
SIZED
WG
NO
.R
EV
PRO
DU
CT LIN
ESC
ALE:
BYD
ATE
SHEET
OF
UN
LESS OTH
ERW
ISE SPECIFIED
TOLER
ANC
ES0 PLAC
ESM
M1 PLAC
EM
MAN
GLES
0.5
0.1
- THR
EAD
DEPTH
S ARE TO
MIN
. FULL TH
DS
- DR
ILL DEPTH
S ARE TO
FULL D
IA.
- REM
OV
E BU
RR
S AND
SHAR
P E
DG
ES- D
O N
OT SC
ALE PRIN
T- M
ACH
INED
SUR
FACE
FINISH
3.2uM [125 uIn]
PRO
PRIETAR
Y DATA
THE IN
FOR
MATIO
N AN
D D
ESIG
N(S) D
ISCLO
SEDH
ERE
IN AR
E THE PR
OPER
TY OF M
TS SYSTEMS
CO
RPO
RATIO
N AN
D M
AY NO
T BE USED
,R
EPRO
DU
CED
OR
DISC
LOSED
IN A
NY FO
RM
EXCEPT AS G
RAN
TED IN
WR
ITING
BY MTS
SYSTEMS C
OR
POR
ATIO
N. TH
IS RESTR
ICTIO
NEXC
LUD
ES INFO
RM
ATION
THA
T IS IN TH
E PU
BLIC D
OM
AIN O
R W
AS LEGITIM
ATELY IN TH
EPR
IOR
POSSES
SION
OF TH
E REC
IPIENT.
mM
TS SYSTEMS C
OR
POR
ATION
SENSO
RS D
IVISION
3001 SHELD
ON
DR
IVE, CAR
Y, NC
27513
METRIC
FIRST
ANG
LED
651543-1
2 2
DR
AWN
BY: M
S
***NO
REVISIO
NS SH
ALL BE MAD
E WITH
OU
T THE N
OTIFIC
ATION
TO APPR
OVAL AG
ENC
Y(S).**
G
C 7898 UPDATED TEMPERATURE ON NOTE 12 TO 71 C M
S 2/23/15D 8037 ADDED W
IRING CHART MS 11/3/15
E 8183 ADDED CL I Zone 0/1 MS 8/18/16
F 8256 UPDATED WIRING CHART ON SHEET 2 M
S 1/30/17G 8482 UPDATED BEND RADIUS TO 15" M
S 5/17/18
+24V GNDEARTHTX/RX+TX/RX-
GND+24V
TX/RX-TX/RX+EARTH
GND+24V
TX/RX-
TX/RX+
EARTH
FIGU
RE 1
SING
LE CAVITY & N
EMA H
OU
SING
FIGU
RE 2
DU
AL CAVITY H
OU
SING
NO
TES: 1. TH
E CU
STOM
ER SH
OU
LD C
ON
NEC
T THE O
UTSID
E GR
OU
ND
LUG
TO TH
E SAFETY EARTH
ING
GR
OU
ND
SYSTEM W
ARN
ING
: C
ON
DU
IT SEALS REQ
UIR
ED W
ITHIN
457 MM
(18") OF H
OU
SING
.
(ACP) INSTALLATIN DWG LP DIGITAL
INTRINSICALLY SAFE FOR US
+24V GND EARTH Tx/Rx+ Tx/Rx-
WIRE COLOR
SIGNALRED
24 V PWR
BLACK 0 V PW
RBLUE
N/AW
HITERX TX +
GREENRX TX -
DRAIN WIRE
EARTH GROUND
WIRING CHART (FOR NEM
A GAUGE)
PIN #SIGNAL
PIN 124 V PW
RPIN 2
0 V PWR
PIN 3N/A
PIN 4RX TX+
PIN 5RX TX-
PIN 6EARTH GROUND
PIN WIRING CHART (FOR NEM
A GAUGE)
LEVEL
Level Plus® CON COMPARTIMIENTOSManual de funcionamiento
I 24 I
Fig. 20: Diagrama de instalación FM de seguridad intrínseca, HART®, página 1
11
22
33
44
55
66
77
88
AA
BB
CC
DD
REV
ECO
#D
ESCR
IPTION
TITLE
SIZED
WG
NO
.R
EV
PRO
DU
CT LIN
ESC
ALE:
BYD
ATE
SHEET
OF
UN
LESS OTH
ERW
ISE SPECIFIED
TOLER
ANC
ES0 PLAC
ESM
M1 PLAC
EM
MAN
GLES
0.5
0.1
- THR
EAD
DEPTH
S ARE TO
MIN
. FULL TH
DS
- DR
ILL DEPTH
S ARE TO
FULL D
IA.
- REM
OV
E BU
RR
S AND
SHAR
P E
DG
ES- D
O N
OT SC
ALE PRIN
T- M
ACH
INED
SUR
FACE
FINISH
3.2uM [125 uIn]
PRO
PRIETAR
Y DATA
THE IN
FOR
MATIO
N AN
D D
ESIG
N(S) D
ISCLO
SEDH
ERE
IN AR
E THE PR
OPER
TY OF M
TS SYSTEMS
CO
RPO
RATIO
N AN
D M
AY NO
T BE USED
,R
EPRO
DU
CED
OR
DISC
LOSED
IN A
NY FO
RM
EXCEPT AS G
RAN
TED IN
WR
ITING
BY MTS
SYSTEMS C
OR
POR
ATIO
N. TH
IS RESTR
ICTIO
NEXC
LUD
ES INFO
RM
ATION
THA
T IS IN TH
E PU
BLIC D
OM
AIN O
R W
AS LEGITIM
ATELY IN TH
EPR
IOR
POSSES
SION
OF TH
E REC
IPIENT.
mM
TS SYSTEMS C
OR
POR
ATION
SENSO
RS D
IVISION
3001 SHELD
ON
DR
IVE, CAR
Y, NC
27513
METRIC
FIRST
ANG
LED
651544-1LEVEL
1 2
DR
AWN
BY: M
S
***NO
REVISIO
NS SH
ALL BE MAD
E WITH
OU
T THE N
OTIFIC
ATION
TO APPR
OVAL AG
ENC
Y(S).**
G
C 7898 UPDATED TEMPERATURE ON NOTE 12 TO 71 C M
S 2/23/15D 8037 ADDED W
IRING CHART MS 11/3/15
E 8183 ADDED CL I Zone 0/1 MS 8/18/16
F 8256 UPDATED WIRING CHART ON SHEET 2 M
S 1/30/17G 8482 UPDATED BEND RADIUS TO 15" M
S 5/17/18
NO
N H
AZARD
OU
S LOC
ATION
HAZAR
DO
US LO
CATIO
N
NO
TES: 1. ALL N
ATION
AL AND
LOC
AL CO
DES AN
D R
EGU
LATION
S MU
ST BE ADH
ERED
TO W
HEN
INSTALLIN
G TH
E MTS LP SEN
SOR
IN H
AZARD
OU
S ENVIR
ON
MEN
TS. SEAL ALL C
ON
DU
ITS WITH
IN 457 M
M (18").
2. LOO
P CABLE M
UST BE 24 AW
G TO
14 AWG
(.511MM
² to 1.6MM
²) SH
IELDED
TWISTED
PAIR C
ABLE WITH
SHIELD
. CABLE C
APACITAN
CE M
UST
BE LESS THAN
30 pF PER FO
OT (98 pF PER
m). C
ABLE SH
IELD IS C
ON
NEC
TED TO
SYSTEM G
RO
UN
D IN
NO
N-H
AZARD
OU
S AREA. SEE IN
STALLATION
MAN
UAL FO
R
ADD
ITION
AL CABLE IN
FOR
MATIO
N.
3. THE R
ESISTANC
E BETWEEN
EARTH
GR
OU
ND
AND
THE IN
TRIN
SICALLY SAFE G
RO
UN
D M
UST BE LESS TH
AN 1 O
HM
. 4. TH
E TRAN
SDU
CER
FRAM
E SHALL BE G
RO
UN
DED
TO EAR
TH G
RO
UN
D D
IREC
TLY OR
THR
OU
GH
THE EQ
UIPM
ENT O
N W
HIC
H IT IS M
OU
NTED
. 5. C
ON
TRO
L EQU
IPMEN
T CO
NN
ECTED
TO ASSO
CIATED
APPARATU
S MU
ST N
OT U
SE OR
GEN
ERATE M
OR
E THAN
250 VRM
S OR
VDC.
6. ASSOC
IATED APPAR
ATUS M
ANU
FACTU
RER
'S INSTALLATIO
N D
RAW
ING
MU
ST BE FO
LLOW
ED W
HEN
INSTALLIN
G TH
IS EQU
IPMEN
T 7. O
NLY U
SE NEC
(e.g FM) APPR
OVED
BARR
IERS.
8. APPRO
VED LO
OP SEPAR
ATION
METH
OD
S: *R
UN
LOO
PS IN SEPAR
ATE CABLES
*RU
N LO
OPS IN
SEPARATE G
RO
UN
DED
SHIELD
S 9. EN
TITY PARAM
ETERS EAC
H LO
OP:
Ui = 28 VD
C Ii = 120 m
A C
i = 0 µF Li = 5 µH Pi = 840 m
W 10. D
UAL-C
AVITY ENC
LOSU
RES:
CU
STOM
ER C
ON
NEC
TION
S WILL BE M
ADE AT TER
MIN
AL BLOC
K ON
POW
ER SID
E O
F HO
USIN
G (N
OT TO
TERM
INAL BLO
CK O
N IN
TERC
ON
NEC
T BOAR
D)
11 INSTALLATIO
N SH
OU
LD BE IN
ACC
OR
DAN
CE W
ITH AN
SI/ISA RP12.06.01 "IN
STALLATION
OF
INTR
INSIC
ALLY SAFE SYSTEMS FO
R H
AZARD
OU
S (CLASSIFIE
D) LO
CATIO
NS"
AND
THE N
ATION
AL ELECTR
ICAL C
OD
E (ANSI/N
FPA 70). 12.TH
E MAXIM
UM
PERM
ITTED AM
BIENT TEM
PERATU
RE O
F THE LEVEL PLU
S DIG
ITAL/ANALO
G
LEVEL TRAN
SMITTER
IS 71 °C. TO
AVOID
THE EFFEC
TS OF PR
OC
ESS TEMPER
ATUR
E AND
O
THER
THER
MAL EFFEC
TS CAR
E SHALL BE TAKEN
TO EN
SUR
E THE SU
RR
OU
ND
ING
AMBIEN
T AN
D TH
E AMBIEN
T INSID
E THE TR
ANSM
ITTER H
OU
SING
DO
ES NO
T EXCEED
71°C 13.C
AUTIO
N: FLEXI BLE G
AUG
ES HAVE A M
INIM
UM
BEND
RAD
IUS O
F 381MM
(15") 14. W
ARN
ING
: THE APPAR
ATUS EN
CLO
SUR
E CO
NTAIN
S ALUM
INU
M AN
D IS C
ON
SIDER
ED TO
CO
NSTITU
TE A POTEN
TIAL RISK O
F IGN
ITION
BY IMPAC
T OR
FRIC
TION
. CAR
E MU
ST BE TAKEN
INTO
ACC
OU
NT D
UR
ING
INSTALLATIO
N AN
D U
SE TO PR
EVENT IM
PACT O
R FR
ICTIO
N 15.W
ARN
ING
: SUBSTITU
TION
OF C
OM
PON
ENTS M
AY IMPAIR
INTR
INSIC
SAFETY. 16.W
ARN
ING
: TO PR
EVENT IG
NITIO
N O
F FLAMM
ABLE O
R C
OM
BUSTIBLE ATM
OSPH
ERES.
DISC
ON
NEC
T POW
ER BEFO
RE SER
VICIN
G.
17.WAR
NIN
G: TH
E EQU
IPMEN
T CO
NTAIN
S NO
N-M
ETALLIC EN
CLO
SUR
E PARTS, TO
PREVEN
T TH
E RISK O
F ELECTR
OSTATIC
SPARKIN
G. TH
E NO
N-M
ETALLIC SU
RFAC
E SHO
ULD
ON
LY BE C
LEANED
WITH
A DAM
P CLO
TH.
EARTH
GR
OU
ND
LUG
NO
TE 3
AGEN
CY C
ON
TRO
LLED D
RAW
ING
(US). N
O C
HAN
GES W
ITHO
UT PR
IOR
AGEN
CY APPR
OVAL
24 VDC
CO
NTR
OL
INPU
T 1
CO
NTR
OL
INPU
T 2
APPRO
VED SAFETY
BARR
IER
APPRO
VED SAFETY
BARR
IER
LOO
P VOLTAG
E
SHIELD
SHIELD
LOO
P 1+
LOO
P 1-
LOO
P 2+
LOO
P 2-
FM
APPROVED US
(ACP) INSTALLATIN DWG LP ANALOG
INTRINSICALLY SAFE FOR US
SING
LE OR
DU
AL CAVITY
NEM
A HO
USIN
G
F
INTRINSICALLY SAFECL. I, DIV. 1, GR. ABCDCL. I Zone 0/1 AEx ia IIC T4 Ta =
-50 to 71°C ; IP65
EARTH
GR
OU
ND
(SEE NO
TE 4)
EARTH
GR
OU
ND
(SEE NO
TE 4)
Level Plus® CON COMPARTIMIENTOSManual de funcionamiento
I 25 I
Fig. 21: Diagrama de instalación FM de seguridad intrínseca, HART®, página 2
DETAIL D
SCALE 3
DETAIL E
SCALE 1.60
DETAIL F
SCALE 1.2
DETAIL H
SCALE 1 : 1
D
E
F
H
11
22
33
44
55
66
77
88
AA
BB
CC
DD
REV
ECO
#D
ESCR
IPTION
TITLE
SIZED
WG
NO
.R
EV
PRO
DU
CT LIN
ESC
ALE:
BYD
ATE
SHEET
OF
UN
LESS OTH
ERW
ISE SPECIFIED
TOLER
ANC
ES0 PLAC
ESM
M1 PLAC
EM
MAN
GLES
0.5
0.1
- THR
EAD
DEPTH
S ARE TO
MIN
. FULL TH
DS
- DR
ILL DEPTH
S ARE TO
FULL D
IA.
- REM
OV
E BU
RR
S AND
SHAR
P E
DG
ES- D
O N
OT SC
ALE PRIN
T- M
ACH
INED
SUR
FACE
FINISH
3.2uM [125 uIn]
PRO
PRIETAR
Y DATA
THE IN
FOR
MATIO
N AN
D D
ESIG
N(S) D
ISCLO
SEDH
ERE
IN AR
E THE PR
OPER
TY OF M
TS SYSTEMS
CO
RPO
RATIO
N AN
D M
AY NO
T BE USED
,R
EPRO
DU
CED
OR
DISC
LOSED
IN A
NY FO
RM
EXCEPT AS G
RAN
TED IN
WR
ITING
BY MTS
SYSTEMS C
OR
POR
ATIO
N. TH
IS RESTR
ICTIO
NEXC
LUD
ES INFO
RM
ATION
THA
T IS IN TH
E PU
BLIC D
OM
AIN O
R W
AS LEGITIM
ATELY IN TH
EPR
IOR
POSSES
SION
OF TH
E REC
IPIENT.
mM
TS SYSTEMS C
OR
POR
ATION
SENSO
RS D
IVISION
3001 SHELD
ON
DR
IVE, CAR
Y, NC
27513
METRIC
FIRST
ANG
LED
651544-1LEVEL
2 2
DR
AWN
BY: M
S
***NO
REVISIO
NS SH
ALL BE MAD
E WITH
OU
T THE N
OTIFIC
ATION
TO APPR
OVAL AG
ENC
Y(S).**
G
C 7898 UPDATED TEMPERATURE ON NOTE 12 TO 71 C M
S 2/23/15D 8037 ADDED W
IRING CHART MS 11/3/15
E 8183 ADDED CL I Zone 0/1 MS 8/18/16
F 8256 UPDATED WIRING CHART ON SHEET 2 M
S 1/30/17G 8482 UPDATED BEND RADIUS TO 15" M
S 5/17/18
LOOP 2-
LOOP 2+
EARTH
LOOP 1-
LOOP 1+
NO
TES: 1. TH
E CU
STOM
ER SH
OU
LD C
ON
NEC
T THE O
UTSID
E GR
OU
ND
LUG
TO TH
E SAFETY EARTH
ING
GR
OU
ND
SYSTEM W
ARN
ING
: C
ON
DU
IT SEALS REQ
UIR
ED W
ITHIN
457 MM
(18") OF H
OU
SING
.
FIGU
RE 2
DU
AL CAVITY H
OU
SING
LOOP 1+ LOOP 1- EARTH LOOP 2+ LOOP 2-
FIGU
RE 1
SING
LE CAVITY & N
EMA H
OU
SING
LOOP 1+ LOOP 1- EARTH LOOP 2+ LOOP 2-
(ACP) IN
STALLATION
DW
G LP AN
ALGO
IN
TRIN
SICALLY SAFE ATEX/IEC
E
LOOP 1+ LOOP 1- EARTH LOOP 2+ LOOP 2-
F
PIN #SIGNAL
PIN 1LOOP 1-
PIN 2LOOP 1+
PIN 3LOOP 2-
PIN 4LOOP 2+
PIN 5N/A
PIN 6EARTH GROUND
WIRE COLOR
SIGNALRED
LOOP 1+BLACK
LOOP 1-BLUE
LOOP 2-W
HITELOOP 2+
GREENN/A
DRAIN WIRE
EARTH GROUND
PIN WIRING CHART (FOR NEM
A GAUGE)
WIRING CHART(FOR NEM
A GAUGE)
Level Plus® CON COMPARTIMIENTOSManual de funcionamiento
I 26 I
13.3.2 Resistente a explosiones/ignífugo
13.3.2.1 Condiciones específicas para un uso seguro
1. Advertencia: El equipo contiene una carcasa y piezas de proceso no metálicas con el fin de evitar que se generen chispas electrostáticas; la superficie no metálica solo se debe limpiar con un paño húmedo. La superficie pintada del equipo puede almacenar carga electrostática y convertirse en fuente de ignición en aplicaciones con una humedad relativa baja con <~30% de humedad relativa donde la superficie pintada está relativamente libre de contaminación (suciedad, polvo o aceite). La limpieza de la superficie pintada solo debe hacerse con un paño húmedo.
2. Los cables deben tener una clasificación de uso de > 5 °C por encima de la temperatura ambiente máxima.
3. Para mantener la clasificación de protección de IP65, se debe usar cinta Teflon™ (3 vueltas) o grasa para tubería. Consulte las instrucciones de instalación.
4. El equipo se puede instalar en la pared que separa un área de Zona 0 y el área menos peligrosa, Zona 1. En esta configuración, la conexión de proceso se instala en la Zona 0, mientras que la carcasa del transmisor se instala en la Zona 1. Consulte las instrucciones de instalación.
5. Los medidores flexibles cuentan con un radio mínimo de curvatura de 381 mm (15 in).
6. La trayectoria de la flama no es para reparación. 7. La clase de temperatura, el rango de temperatura ambiente y el
rango de temperatura del proceso aplicables del equipo son las que siguen: • T3 con rango de temperatura del proceso de −40 °C a +150 °C • T4 con rango de temperatura del proceso de −40 °C a +135 °C• T5 con rango de temperatura del proceso de −40 °C a +100 °C• T6 con rango de temperatura del proceso de −40 °C a +85 °C
El rango de temperatura ambiente es de −40 °C≤Ta≤71 °C 8. Durante el montaje del MLG (medidor de nivel magnético),
asegúrese de que el cabezal electrónico y la barrera de presión cuenten con un espaciado de al menos 5 pulgadas. Consulte el Manual de instalación para obtener más información.
1
1
2
2
A A
B B
REV ECO # DESCRIPTION
TITLE
SIZE DWG NO. REV
PRODUCT LINESCALE:
BY DATE
SHEET OF
UNLESS OTHERWISE SPECIFIEDTOLERANCES
0 PLACESMM
1 PLACEMM
ANGLES� � �� 0.5 � 0.1
- THREAD DEPTHS ARE TO MIN. FULL THDS- DRILL DEPTHS ARE TO FULL DIA.- REMOVE BURRS AND SHARP EDGES- DO NOT SCALE PRINT- MACHINED SURFACE FINISH 3.2uM [125 uIn]
PROPRIETARY DATATHE INFORMATION AND DESIGN(S) DISCLOSEDHEREIN ARE THE PROPERTY OF MTS SYSTEMSCORPORATION AND MAY NOT BE USED,REPRODUCED OR DISCLOSED IN ANY FORMEXCEPT AS GRANTED IN WRITING BY MTSSYSTEMS CORPORATION. THIS RESTRICTIONEXCLUDES INFORMATION THAT IS IN THE PUBLIC DOMAIN OR WAS LEGITIMATELY IN THEPRIOR POSSESSION OF THE RECIPIENT.
mMTS SYSTEMS CORPORATIONSENSORS DIVISION3001 SHELDON DRIVE, CARY, NC 27513
METRIC
FIRST ANGLE A 551474- A
1 1
DRAWN BY: MS
***NO REVISIONS SHALL BE MADE WITHOUT THE NOTIFICATION TO APPROVAL AGENCY(S).***A MS 7/28/16
Level Plus Transmitter�
MTS Systems CorporationSensors Division3001 Sheldon Drive, Cary, N.C. 27513
FM16US0242X
EXPLOSION PROOF FOR CL. I, DIV. 1, GR BCD T6...T3.
(B, C, D)
CL. I, ZONE 0/1, AEx db IIB+H2 T6...T3 Ga/GbTa = -40°C TO +71°C ; IP 65INPUT: 28V (120mA) maxOUTPUT: RS485 WARNING: DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE IS PRESENT. FOR ZONE INSTALLATIONS, A SEAL SHALL BE INSTALLED WITHIN 50mm OF THE ENCLOSURE. FOR DIVISION INSTALLATIONS A SEAL SHALL BE INSTALLED WITHIN 18 INCHESOF THE ENCLOSURE
INSTALL PER # 651552-1MAX. PRESSURE 1000 PSI (RIGID SENSOR)
MAX. PRESSURE 435 PSI (FLEX SENSOR)
7957 RELEASE FOR PRODUCTION
(ACP) LABEL, LP, XP US - DIGITAL
FM
LEVEL
1:1
APPROVED
P/N 551474-1 Rev A
R
!
Fig. 22: Resistente a explosiones, etiqueta FM, Modbus o DDA, opción de carcasa G, H o L
Fig. 23: Resistente a explosiones, etiqueta FM, Modbus o DDA, opción de carcasa D, E
Fig. 24: Resistente a explosiones, etiqueta FM, HART®, opción de carcasa G, H o L
Fig. 25: Resistente a explosiones, etiqueta FM, HART®, opción de carcasa D, E
1
1
2
2
A A
B B
REV ECO # DESCRIPTION
TITLE
SIZE DWG NO. REV
PRODUCT LINESCALE:
BY DATE
SHEET OF
UNLESS OTHERWISE SPECIFIEDTOLERANCES
0 PLACESMM
1 PLACEMM
ANGLES� � �� 0.5 � 0.1
- THREAD DEPTHS ARE TO MIN. FULL THDS- DRILL DEPTHS ARE TO FULL DIA.- REMOVE BURRS AND SHARP EDGES- DO NOT SCALE PRINT- MACHINED SURFACE FINISH 3.2uM [125 uIn]
PROPRIETARY DATATHE INFORMATION AND DESIGN(S) DISCLOSEDHEREIN ARE THE PROPERTY OF MTS SYSTEMSCORPORATION AND MAY NOT BE USED,REPRODUCED OR DISCLOSED IN ANY FORMEXCEPT AS GRANTED IN WRITING BY MTSSYSTEMS CORPORATION. THIS RESTRICTIONEXCLUDES INFORMATION THAT IS IN THE PUBLIC DOMAIN OR WAS LEGITIMATELY IN THEPRIOR POSSESSION OF THE RECIPIENT.
mMTS SYSTEMS CORPORATIONSENSORS DIVISION3001 SHELDON DRIVE, CARY, NC 27513
METRIC
FIRST ANGLE A 551474- A
1 1
DRAWN BY: MS
***NO REVISIONS SHALL BE MADE WITHOUT THE NOTIFICATION TO APPROVAL AGENCY(S).***A MS 7/28/16
Level Plus Transmitter�
MTS Systems CorporationSensors Division3001 Sheldon Drive, Cary, N.C. 27513
FM16US0242X
EXPLOSION PROOF FOR CL. I, DIV. 1, GR. CL. I, ZONE 0/1, AEx db IIB+H2 T6...T3 Ga/GbTa = -40
ABCD T6...T3
°C TO +71°C ; IP 65INPUT: 28V (120mA) maxOUTPUT: RS485 WARNING: DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE IS PRESENT. FOR ZONE INSTALLATIONS, A SEAL SHALL BE INSTALLED WITHIN 50mm OF THE ENCLOSURE. FOR DIVISION INSTALLATIONS A SEAL SHALL BE INSTALLED WITHIN 18 INCHESOF THE ENCLOSURE
INSTALL PER # 651552-1MAX. PRESSURE 1000 PSI (RIGID SENSOR)
MAX. PRESSURE 435 PSI (FLEX SENSOR)
7957 RELEASE FOR PRODUCTION
(ACP) LABEL, LP, XP US - DIGITAL
FM
LEVEL
1:1
APPROVED
P/N 551474-2 Rev A
R
!
1
1
2
2
A A
B B
REV ECO # DESCRIPTION
TITLE
SIZE DWG NO. REV
PRODUCT LINESCALE:
BY DATE
SHEET OF
UNLESS OTHERWISE SPECIFIEDTOLERANCES
0 PLACESMM
1 PLACEMM
ANGLES� � �� 0.5 � 0.1
- THREAD DEPTHS ARE TO MIN. FULL THDS- DRILL DEPTHS ARE TO FULL DIA.- REMOVE BURRS AND SHARP EDGES- DO NOT SCALE PRINT- MACHINED SURFACE FINISH 3.2uM [125 uIn]
PROPRIETARY DATATHE INFORMATION AND DESIGN(S) DISCLOSEDHEREIN ARE THE PROPERTY OF MTS SYSTEMSCORPORATION AND MAY NOT BE USED,REPRODUCED OR DISCLOSED IN ANY FORMEXCEPT AS GRANTED IN WRITING BY MTSSYSTEMS CORPORATION. THIS RESTRICTIONEXCLUDES INFORMATION THAT IS IN THE PUBLIC DOMAIN OR WAS LEGITIMATELY IN THEPRIOR POSSESSION OF THE RECIPIENT.
mMTS SYSTEMS CORPORATIONSENSORS DIVISION3001 SHELDON DRIVE, CARY, NC 27513
METRIC
FIRST ANGLE A 551495- A
1 1
DRAWN BY: MS
***NO REVISIONS SHALL BE MADE WITHOUT THE NOTIFICATION TO APPROVAL AGENCY(S).***A MS 7/28/16
Level Plus TransmitterFM16US0242X
�
MTS Systems CorporationSensors Division3001 Sheldon Drive, Cary, N.C. 27513
EXPLOSION PROOF FOR CL. I, DIV. 1, GR.
(A, B, C, D)
BCD T6...T3CL. I, ZONE 0/1, AEx db IIB+H2 T6...T3 Ga/GbTa = -40°C TO +71°C ; IP 65INPUT: 28V (120mA) maxOUTPUT: 4-20mA WARNING: DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE IS PRESENT. FOR ZONE INSTALLATIONS, A SEAL SHALL BE INSTALLED WITHIN 50mm OF THE ENCLOSURE. FOR DIVISION INSTALLATIONS A SEAL SHALL BE INSTALLED WITHIN 18 INCHESOF THE ENCLOSURE
INSTALL PER # 651553-1MAX. PRESSURE 1000 PSI (RIGID SENSOR)MAX. PRESSURE 435 PSI (FLEX SENSOR)
7957 RELEASE FOR PRODUCTION
(ACP) LABEL, LP, XP US - ANALOG
FM
LEVEL
1:1
APPROVED
P/N 551495-1 Rev A
R
!
1
1
2
2
A A
B B
REV ECO # DESCRIPTION
TITLE
SIZE DWG NO. REV
PRODUCT LINESCALE:
BY DATE
SHEET OF
UNLESS OTHERWISE SPECIFIEDTOLERANCES
0 PLACESMM
1 PLACEMM
ANGLES� � �� 0.5 � 0.1
- THREAD DEPTHS ARE TO MIN. FULL THDS- DRILL DEPTHS ARE TO FULL DIA.- REMOVE BURRS AND SHARP EDGES- DO NOT SCALE PRINT- MACHINED SURFACE FINISH 3.2uM [125 uIn]
PROPRIETARY DATATHE INFORMATION AND DESIGN(S) DISCLOSEDHEREIN ARE THE PROPERTY OF MTS SYSTEMSCORPORATION AND MAY NOT BE USED,REPRODUCED OR DISCLOSED IN ANY FORMEXCEPT AS GRANTED IN WRITING BY MTSSYSTEMS CORPORATION. THIS RESTRICTIONEXCLUDES INFORMATION THAT IS IN THE PUBLIC DOMAIN OR WAS LEGITIMATELY IN THEPRIOR POSSESSION OF THE RECIPIENT.
mMTS SYSTEMS CORPORATIONSENSORS DIVISION3001 SHELDON DRIVE, CARY, NC 27513
METRIC
FIRST ANGLE A 551495- A
1 1
DRAWN BY: MS
***NO REVISIONS SHALL BE MADE WITHOUT THE NOTIFICATION TO APPROVAL AGENCY(S).***A MS 7/28/16
Level Plus TransmitterFM16US0242X
�
MTS Systems CorporationSensors Division3001 Sheldon Drive, Cary, N.C. 27513
EXPLOSION PROOF FOR CL. I, DIV. 1, GR.
(A, B, C, D)
BCD T6...T3CL. I, ZONE 0/1, AEx db IIB+H2 T6...T3 Ga/GbTa = -40°C TO +71°C ; IP 65INPUT: 28V (120mA) maxOUTPUT: 4-20mA WARNING: DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE IS PRESENT. FOR ZONE INSTALLATIONS, A SEAL SHALL BE INSTALLED WITHIN 50mm OF THE ENCLOSURE. FOR DIVISION INSTALLATIONS A SEAL SHALL BE INSTALLED WITHIN 18 INCHESOF THE ENCLOSURE
INSTALL PER # 651553-1MAX. PRESSURE 1000 PSI (RIGID SENSOR)MAX. PRESSURE 435 PSI (FLEX SENSOR)
7957 RELEASE FOR PRODUCTION
(ACP) LABEL, LP, XP US - ANALOG
FM
LEVEL
1:1
APPROVED
P/N 551495-1 Rev A
R
!
13.3.2.2 Etiquetas
Level Plus® CON COMPARTIMIENTOSManual de funcionamiento
I 27 I
13.3.2.3 Plano de instalación
Fig. 26: Resistente a explosiones, plano de instalación FM, Modbus y DDA, página 1
11
22
33
44
55
66
77
88
AA
BB
CC
DD
REV
ECO
#D
ESCR
IPTION
TITLE
SIZED
WG
NO
.R
EV
PRO
DU
CT LIN
ESC
ALE:
BYD
ATE
SHEET
OF
UN
LESS OTH
ERW
ISE SPECIFIED
TOLER
ANC
ES0 PLAC
ESM
M1 PLAC
EM
MAN
GLES
0.5
0.1
- THR
EAD
DEPTH
S ARE TO
MIN
. FULL TH
DS
- DR
ILL DEPTH
S ARE TO
FULL D
IA.
- REM
OV
E BU
RR
S AND
SHAR
P E
DG
ES- D
O N
OT SC
ALE PRIN
T- M
ACH
INED
SUR
FACE
FINISH
3.2uM [125 uIn]
PRO
PRIETAR
Y DATA
THE IN
FOR
MATIO
N AN
D D
ESIG
N(S) D
ISCLO
SEDH
ERE
IN AR
E THE PR
OPER
TY OF M
TS SYSTEMS
CO
RPO
RATIO
N AN
D M
AY NO
T BE USED
,R
EPRO
DU
CED
OR
DISC
LOSED
IN A
NY FO
RM
EXCEPT AS G
RAN
TED IN
WR
ITING
BY MTS
SYSTEMS C
OR
POR
ATIO
N. TH
IS RESTR
ICTIO
NEXC
LUD
ES INFO
RM
ATION
THA
T IS IN TH
E PU
BLIC D
OM
AIN O
R W
AS LEGITIM
ATELY IN TH
EPR
IOR
POSSES
SION
OF TH
E REC
IPIENT.
mM
TS SYSTEMS C
OR
POR
ATION
SENSO
RS D
IVISION
3001 SHELD
ON
DR
IVE, CAR
Y, NC
27513
METRIC
FIRST
ANG
LED
651553-1B
LEVEL1
2 D
RAW
N BY:
MS
***NO
REVISIO
NS SH
ALL BE MAD
E WITH
OU
T THE N
OTIFIC
ATION
TO APPR
OVAL AG
ENC
Y(S).***B
MS
10/22/15RELEASE TO PRODUCTION
8482UPDATED W
IRING DWG TO ANALOG
MS
5/17/18A
7957
EARTH GROUND
LOOP 2-
LOOP 2+
EARTH GROUND
LOOP 1-
LOOP 1+
ZONE 1
ZONE 0SEE NOTE 8
EARTH
GR
OU
ND
LUG
NO
TE 3
AGEN
CY C
ON
TRO
LLED D
RAW
ING
(US). N
O C
HAN
GES W
ITHO
UT PR
IOR
AGEN
CY APPR
OVAL
FM
APPROVED
(ACP) INSTALLATIN DWG LP ANALOG
EXPLOSION PROOF US
SING
LE OR
DU
AL CAVITY
FM US- FM
16US0242XEXPLOSION PROOFCL. I, DIV. 1, GR. ABCD T6...T3CL. I, DIV. 1, GR. BCD T6...T3CL. 1, ZN. 0/1, AEx db IIB+H2 T6...T3 Ga/GbTa =
-40°C to +71°C ; IP65
HAZARDOUS LOCATIONNON HAZARDOUS LOCATION
CO
ND
UIT SEAL
CO
ND
UIT
SEE NO
TE 1
CO
ND
UIT SEAL
5" [127mm
] Minim
um
NO
TES:1.ALL N
ATION
AL AND
LOC
AL CO
DES AN
D R
EGU
LATION
S MU
ST BE ADH
ERED
TO W
HEN
INSTALLIN
G TH
E LEVEL SENSO
R IN
HAZAR
DO
US EN
VIRO
NM
ENTS.
FOR
ZON
E INSTALLATIO
NS, A SEAL SH
ALL BE INSTALLED
WITH
IN 50m
m O
F THE
ENC
LOSU
RE. FO
R D
IVISION
INSTALLATIO
NS, A SEAL SH
ALL BE INSTALLED
WITH
IN 18 IN
CH
ES OF TH
E ENC
LOSU
RE.
2.DU
AL-CAVITY EN
CLO
SUR
ES: C
USTO
MER
CO
NN
ECTIO
NS W
ILL BE MAD
E AT TERM
INAL BLO
CK O
N PO
WER
SIDE
OF H
OU
SING
(NO
T TO TER
MIN
AL BLOC
K ON
INTER
CO
NN
ECT BO
ARD
). SEE FIGU
RE 2 O
N PAG
E 23. C
AUTIO
N: FLEXIBLE G
AUG
ES HAVE A M
INIM
UM
BEND
RAD
IUS O
F 381mm
(15")4.W
ARN
ING
: TO PR
EVENT IG
NITIO
N O
F FLAMM
ABLE OR
CO
MBU
STIBLE ATMO
SPHER
ES, D
ISCO
NN
ECT PO
WER
BEFOR
E SERVIC
ING
5.W
ARN
ING
: THE EQ
UIPM
ENT C
ON
TAINS N
ON
-METALLIC
ENC
LOSU
RE AN
D PR
OC
ESS PARTS, TO
PREVEN
T TH
E RISK O
F ELECTR
OSTATIC
SPARKIN
G. TH
E N ON
-METALLIC
SUR
FACE AN
D PR
OC
ESS PARTS SH
OU
LD O
NLY
BE CLEAN
ED W
ITH A D
AMP C
LOTH
. PAINTED SURFACE OF THE EQUIPMENT M
AY STORE ELECTROSTATIC CHARGE AND BECOM
E A SOURCE OF IGNITION IN APPLICATIONS WITH A LOW
RELATIVE HUMIDITY <
~30% RELATIVE
HUMIDITY W
HERE THE PAINTED SURFACE IS RELATIVELY FREE OF SURFACE CONTAMINATION
SUCH AS DIRT, DUST OR OIL. CLEANING OF THE PAINTED SURFACE SHOULD ONLY BE DONE W
ITH A DAMP CLOTH.
6. CABLES SH
ALL BE RATED
> 5C ABO
VE MAXIM
UM
AMBIEN
T TEMPER
ATUR
E. 7. TO
MAIN
TAIN TH
E ING
RESS PR
OTEC
TION
RATIN
G O
F IP65, TEFLON
TAPE (3 WR
APS) OR
PIPE DO
PE SHALL
BE USED
. REFER
TO IN
STALLATION
INSTR
UC
TION
S.8. TH
E EQU
IPMEN
T CAN
BE INSTALLED
IN TH
E BOU
ND
ARY W
ALL BETWEEN
A ZON
E 0 AREA AN
D TH
E LESS H
AZARD
OU
S AREA, ZO
NE 1. IN
THIS C
ON
FIGU
RATIO
N, TH
E PRO
CESS C
ON
NE C
TION
IS INSTALLED
IN
A ZON
E 0 AREA, W
HILE TH
E TRAN
SMITTER
HO
USIN
G IS IN
STALLED IN
A ZON
E 1 AREA.
9. THE APPLIC
ABLE TEMPER
ATUR
E CLASS O
F THE EQ
UIPM
ENT, AM
BIENT TEM
PERATU
RE R
ANG
E, AN
D M
AXIMU
M PR
OC
ESS TEMPER
ATUR
E OF TH
E EQU
IPMEN
T IS AS FOLLO
WS;
T3 WITH
PRO
CESS TEM
PERATU
RE R
ANG
E OF -40°C
to +150°C T4 W
ITH PR
OC
ESS TEMPER
ATUR
E RAN
GE O
F -40°C to +135°C
T5 WITH
PRO
CESS TEM
PERAT U
RE R
ANG
E OF -40°C
to +100°C T6 W
ITH PR
OC
ESS TEMPER
ATUR
E RAN
GE O
F -40°C to +85°C
AMBIEN
T TEMPER
ATUR
E RAN
GE -40°C Ta+71°C
10. WH
EN M
OU
NTIN
G O
N A M
AGN
ETIC LEVEL G
AUG
E MAKE SU
RE TH
E ELECTR
ON
IC H
EAD AN
D PR
ESSUR
E BAR
RIER
HAVE A M
INIM
UM
SPACIN
G O
F 5 INC
HES. SEE IN
STALLATION
MAN
UAL FO
R D
ETAIL11. FLAM
EPATHS AR
E NO
T FOR
REPAIR
Level Plus® CON COMPARTIMIENTOSManual de funcionamiento
I 28 I
Fig. 27: Resistente a explosiones, plano de instalación FM, Modbus y DDA, página 2
DETAIL D
SCALE 3
DETAIL E
SCALE 1.60
DETAIL F
SCALE 1.2
D
E
F
11
22
33
44
55
66
77
88
AA
BB
CC
DD
REV
ECO
#D
ESCR
IPTION
TITLE
SIZED
WG
NO
.R
EV
PRO
DU
CT LIN
ESC
ALE:
BYD
ATE
SHEET
OF
UN
LESS OTH
ERW
ISE SPECIFIED
TOLER
ANC
ES0 PLAC
ESM
M1 PLAC
EM
MAN
GLES
0.5
0.1
- THR
EAD
DEPTH
S ARE TO
MIN
. FULL TH
DS
- DR
ILL DEPTH
S ARE TO
FULL D
IA.
- REM
OV
E BU
RR
S AND
SHAR
P E
DG
ES- D
O N
OT SC
ALE PRIN
T- M
ACH
INED
SUR
FACE
FINISH
3.2uM [125 uIn]
PRO
PRIETAR
Y DATA
THE IN
FOR
MATIO
N AN
D D
ESIG
N(S) D
ISCLO
SEDH
ERE
IN AR
E THE PR
OPER
TY OF M
TS SYSTEMS
CO
RPO
RATIO
N AN
D M
AY NO
T BE USED
,R
EPRO
DU
CED
OR
DISC
LOSED
IN A
NY FO
RM
EXCEPT AS G
RAN
TED IN
WR
ITING
BY MTS
SYSTEMS C
OR
POR
ATIO
N. TH
IS RESTR
ICTIO
NEXC
LUD
ES INFO
RM
ATION
THA
T IS IN TH
E PU
BLIC D
OM
AIN O
R W
AS LEGITIM
ATELY IN TH
EPR
IOR
POSSES
SION
OF TH
E REC
IPIENT.
mM
TS SYSTEMS C
OR
POR
ATION
SENSO
RS D
IVISION
3001 SHELD
ON
DR
IVE, CAR
Y, NC
27513
METRIC
FIRST
ANG
LED
651553-1B
LEVEL2
2 D
RAW
N BY:
MS
***NO
REVISIO
NS SH
ALL BE MAD
E WITH
OU
T THE N
OTIFIC
ATION
TO APPR
OVAL AG
ENC
Y(S).***B
MS
5/17/18RELEASE TO PRODUCTION
8482UPDATED W
IRING DWG TO ANALOG
MS
5/17/18A
7957
LOOP 2-
LOOP 2+
EARTH
LOOP 1-
LOOP 1+
NO
TES: 1. TH
E CU
STOM
ER SH
OU
LD C
ON
NEC
T THE O
UTSID
E GR
OU
ND
LUG
TO TH
E SAFETY EARTH
ING
GR
OU
ND
SYSTEM W
ARN
ING
: FO
R ZO
NE IN
STALLATION
S, A SEAL SHALL BE IN
STALLED W
ITHIN
50mm
OF TH
E EN
CLO
SUR
E. FOR
DIVISIO
N IN
STALLATION
S, A SEAL SHALL BE IN
STALLED W
ITHIN
18 INC
HES O
F THE EN
CLO
SUR
E.
FIGU
RE 2
DU
AL CAVITY H
OU
SING
LOOP 1+ LOOP 1- EARTH LOOP 2+ LOOP 2-
FIGU
RE 1
SING
LE CAVITY H
OU
SING
(ACP) IN
STALLATION
DW
G LP AN
ALOG
IN
TRIN
SICALLY SAFE U
S
LOOP 1+ LOOP 1- EARTH LOOP 2+ LOOP 2-
Level Plus® CON COMPARTIMIENTOSManual de funcionamiento
I 29 I
11
22
33
44
55
66
77
88
AA
BB
CC
DD
REV
EC
O #
DESC
RIP
TION
TITLE
SIZED
WG
NO
.R
EV
PRO
DU
CT LIN
ESC
ALE:
BYD
ATE
SHEET
OF
UN
LES
S OTH
ER
WISE
SPEC
IFIED
TOLER
ANC
ES0 P
LACE
SM
M1 PLA
CE
MM
AN
GLE
S
0.5
0.1
- THR
EA
D D
EP
THS
AR
E TO
MIN
. FULL TH
DS
- DR
ILL DE
PTH
S A
RE
TO FU
LL DIA
.- R
EM
OV
E B
UR
RS
AN
D S
HA
RP
ED
GE
S- D
O N
OT S
CA
LE P
RIN
T- M
AC
HIN
ED
SU
RFA
CE
FINIS
H 3.2uM
[125 uIn]
PRO
PRIETA
RY D
ATA
THE
INFO
RM
ATIO
N A
ND
DE
SIG
N(S
) DIS
CLO
SE
DH
ER
EIN
AR
E TH
E P
RO
PE
RTY
OF M
TS S
YS
TEM
SC
OR
PO
RA
TION
AN
D M
AY
NO
T BE
US
ED
,R
EP
RO
DU
CE
D O
R D
ISC
LOS
ED
IN A
NY
FOR
ME
XC
EP
T AS
GR
AN
TED
IN W
RITIN
G B
Y M
TSS
YS
TEM
S C
OR
PO
RA
TION
. THIS
RE
STR
ICTIO
NE
XC
LUD
ES
INFO
RM
ATIO
N TH
AT IS
IN TH
E
PU
BLIC
DO
MA
IN O
R W
AS
LEG
ITIMA
TELY
IN TH
EP
RIO
R P
OS
SE
SS
ION
OF TH
E R
EC
IPIE
NT.
mM
TS SYS
TEMS
CO
RP
OR
ATIO
NS
ENSO
RS D
IVISIO
N3001 SH
ELDO
N D
RIVE
, CA
RY, N
C 27513
METRIC
FIRST
ANG
LED
651552-1A
1
2 D
RAW
N BY:
MS
***NO
RE
VISION
S SHALL BE
MA
DE
WITH
OU
T THE
NO
TIFICA
TION
TO A
PPRO
VAL AG
EN
CY(S).***
AM
S6/22/16
RELEASE TO PRO
DU
CTION
24 VDC
COM
MO
N-
Rx /Tx+
Rx /Tx-
EARTH G
ROU
ND
EARTH G
ROU
ND
ZON
E 1
ZON
E 0
SEE NO
TE 8
NO
N H
AZARDO
US LO
CATION
HAZARD
OU
S LOCATIO
N
AGEN
CY C
ON
TRO
LLED D
RAW
ING
(US). N
O C
HAN
GES W
ITHO
UT PR
IOR
AGEN
CY APPR
OVAL
EARTH TERM
INAL
(ACP) INSTALLATIO
N D
WG
LP DIG
ITAL EXPLO
SION
PROO
F US
7957
LEVEL
FM
APPROVED
N/A
EXPLOSIO
N PRO
OF
CL. I, DIV. 1, G
R. ABCD T6...T3
CL. I, DIV. 1, G
R. BCD T6...T3
CL. 1, ZN. 0/1, AEx db IIB+
H2 T6...T3 G
a/Gb
Ta = -40°C to +
71°C ; IP65
NO
TES:1.A
LL NATIO
NAL AN
D LO
CAL C
OD
ES AND
REG
ULATIO
NS M
UST BE AD
HER
ED TO
WH
EN IN
STALLING
THE LEVEL SEN
SOR
IN H
AZAR
DO
US EN
VIRO
NM
ENTS.
FOR
ZON
E INSTALLATIO
NS, A SEAL SH
ALL BE INSTALLED
WITH
IN 50m
m O
F THE
ENC
LOSU
RE
. FOR
DIVISIO
N IN
STALLA TION
S, A SEAL SHALL BE IN
STALLED W
ITHIN
18 INC
HES O
F THE EN
CLO
SUR
E.2.D
UAL-C
AVITY ENC
LOSU
RES:
CU
STOM
ER C
ON
NEC
TION
S WILL BE M
ADE AT TER
MIN
AL BLOC
K ON
POW
ER SID
E O
F HO
US
ING
(NO
T TO TER
MIN
AL BLO
CK O
N IN
TERC
ON
NEC
T BO
ARD
). SEE FIGU
RE 2 O
N PAG
E 23. C
AUTIO
N: FLEX
IBLE G
AUG
ES HAVE A M
INIM
UM
BEND
RAD
IUS O
F 381mm
(15")4.W
ARN
ING
: TO PR
EVENT IG
NITIO
N O
F FLAMM
ABLE OR
CO
MBU
STIBLE ATMO
SPHER
ES, D
ISCO
N NEC
T POW
ER BE
FOR
E SERVIC
ING
5.W
ARN
ING
: THE EQ
UIPM
ENT C
ON
TAINS
NO
N-M
ETALLIC E
NC
LOSU
RE
AND
PRO
CESS PAR
TS, TO PR
EVENT
THE R
ISK OF ELEC
TRO
STATIC SPAR
KING
. THE N
ON
-METALLIC
SUR
FAC
E AND
PRO
CES
S PARTS SH
OU
LD O
NLY
BE CLEAN
ED W
ITH A
DAM
P CLO
TH. PAIN
TED SU
RFACE OF TH
E EQU
IPMEN
T MAY STO
RE ELECTROSTATIC CH
ARG
E AN
D BECO
ME A SO
URCE O
F IGN
ITION
IN APPLICATIO
NS W
ITH A LO
W RELATIVE H
UM
IDITY <
~30%
RELATIVE H
UM
IDITY W
HERE TH
E PAINTED
SURFACE IS R
ELATIVELY FREE OF SU
RFACE CON
TAMIN
ATION
SUCH
AS DIRT, D
UST O
R OIL. CLEAN
ING
OF TH
E PAINTED
SURFACE SH
OU
LD O
NLY BE D
ON
E W
ITH A D
AMP CLO
TH.
6. CABLES SH
ALL BE RATED
> 5C ABO
VE MAXIM
UM
AMBIEN
T TEMPER
ATU
RE.
7. TO M
AINTAIN
THE IN
GR
ESS PR
OTEC
TION
RATIN
G O
F IP65, TEFLON
TAPE (3 WR
APS) OR
PIPE DO
PE SHALL
BE USED
. REFER
TO IN
STALLA
TION
INSTR
UC
TION
S.8. TH
E EQ
UIP
ME
NT C
AN BE IN
STALLED IN
THE BO
UN
DAR
Y WALL BETW
EEN A ZO
NE 0 A
REA AN
D TH
E LESS H
AZARD
OU
S AREA, ZO
NE 1. IN
THIS C
ON
FIGU
RATIO
N, TH
E PRO
CE
SS CO
NN
ECTIO
N IS IN
STALLED
IN
A ZON
E 0 AREA, W
HILE TH
E TR
ANS
MITTER
HO
US
ING
IS INSTALLED
IN A ZO
NE 1 AR
EA. 9. TH
E APPLIC
ABLE TEM
PERATU
RE C
LASS O
F THE
EQ
UIP
MEN
T, AM
BIEN
T TEMPER
ATUR
E RA
NG
E,
AND
MAX
IMU
M PR
OC
ESS TEM
PERATU
RE O
F THE EQ
UIPM
ENT IS AS FO
LLOW
S; T3 W
ITH P
RO
CESS TEM
PERATU
RE R
ANG
E OF -40°C
to +150°C T4 W
ITH P
RO
CESS TEM
PERATU
RE R
ANG
E OF -40°C
to +135°C T5 W
ITH P
RO
CESS TEM
PERATU
RE R
ANG
E OF -40°C
to +100°C T6 W
ITH P
RO
CESS TEM
PERATU
RE R
ANG
E OF -40°C
to +85°C AM
BIENT TEM
PERATU
RE
RAN
GE -40°C Ta+71°C
10. WH
EN M
OU
NTIN
G O
N A M
AG
NETIC
LEVEL G
AU
GE M
AKE S
UR
E TH
E ELEC
TRO
NIC
HEA
D AN
D PR
ESS
UR
E
BAR
RIE
R H
AVE
A MIN
IMU
M SP
AC
ING
OF 5 IN
CH
ES. S
EE IN
STALLATIO
N M
AN
UAL FO
R D
ETAIL
11. FLAM
EPA
THS A
RE N
OT FO
R R
EPA
IR
FM U
S- FM16U
S0242X
CON
DU
IT SEALCON
DU
IT
SEE NO
TE 1
CON
DU
IT SEAL
Fig. 28: Resistente a explosiones, plano de instalación FM, HART®, página 1
Level Plus® CON COMPARTIMIENTOSManual de funcionamiento
I 30 I
DETAIL F
SCALE 1.60 : 1
DETAIL G
SCALE 3 : 1
DETAIL H
SCALE 1.2
F
G
H
11
22
33
44
55
66
77
88
AA
BB
CC
DD
REV
ECO
#D
ESCR
IPTION
TITLE
SIZED
WG
NO
.R
EV
PRO
DU
CT LIN
ESC
ALE:
BYD
ATE
SHEET
OF
UN
LESS OTH
ERW
ISE SPECIFIED
TOLER
ANC
ES0 PLAC
ESM
M1 PLAC
EM
MAN
GLES
0.5
0.1
- THR
EAD D
EPTHS AR
E TO M
IN. FU
LL THD
S- D
RILL D
EPTHS AR
E TO FU
LL DIA.
- REM
OVE BU
RR
S AND
SHAR
P EDG
ES- D
O N
OT SC
ALE PRIN
T- M
ACH
INED
SUR
FACE FIN
ISH 3.2uM
[125 uIn]
PRO
PRIETAR
Y DATA
THE IN
FOR
MATIO
N AN
D D
ESIGN
(S) DISC
LOSED
HER
EIN AR
E THE PR
OPER
TY OF M
TS SYSTEMS
CO
RPO
RA TIO
N AN
D M
AY NO
T BE USED
,R
EPRO
DU
CED
OR
DISC
LOSED
IN AN
Y FOR
MEXC
EPT AS GR
ANTED
IN W
RITIN
G BY M
TSSYSTEM
S CO
RPO
RATIO
N. TH
IS RESTR
ICTIO
NEXC
LUD
ES INFO
RM
ATION
THAT IS IN
THE
PUBLIC
DO
MAIN
OR
WAS LEG
ITIMATELY IN
THE
PRIO
R PO
SSESSION
OF TH
E REC
IPIENT.
mM
TS SYSTEMS C
OR
POR
ATION
SENSO
RS D
IVISION
3001 SHELD
ON
DR
IVE, CAR
Y, NC
27513
METRIC
FIRST
ANG
LED
651552-1A
2
2 D
RAW
N BY:
MS
***NO
REVISIO
NS SH
ALL BE MAD
E WITH
OU
T THE N
OTIFIC
ATION
TO APPR
OVAL AG
ENC
Y(S).***A
MS
10/24/14RELEASE TO
PROD
UCTIO
N
+24V GNDEARTHTX/RX+TX/RX-
GND
+24V
TX/RX-
TX/RX+
EARTH
FIGU
RE 1
SING
LE CAVITY
FIGU
RE 2
DU
AL CAVITY H
OU
SING
NO
TES: 1. TH
E CU
STOM
ER SH
OU
LD C
ON
NEC
T THE O
UTSID
E GR
OU
ND
LUG
TO TH
E SAFETY EARTH
ING
GR
OU
ND
SYSTEM W
ARN
ING
: FO
R ZO
NE IN
STALLATION
S, A SEAL SHALL BE IN
STALLED W
ITHIN
50mm
OF TH
EEN
CLO
SUR
E. FOR
DIVISIO
N IN
STALLATION
S, A SEAL SHALL BE IN
STALLED W
ITHIN
18 INC
HES O
F THE EN
CLO
SUR
E.
(ACP) INSTALLATIO
N D
WG
LP DIG
ITAL EXPLO
SION
PROO
F U.S.A
+24V GND EARTH Tx/Rx+ Tx/Rx-
7957
Fig. 29: Resistente a explosiones, plano de instalación FM, HART®, página 2
Level Plus® CON COMPARTIMIENTOSManual de funcionamiento
I 31 I
13.4 FMC (CEC)
13.4.1 Seguridad intrínseca
13.4.1.1 Condiciones específicas para un uso seguro 1. La carcasa del aparato contiene aluminio y se considera que esto
constituye un riesgo potencial de ignición por impacto o fricción. Se debe tener cuidado durante la instalación y el uso para evitar impactos o fricción. (cuando se instala con aprobación de Ga)
2. La temperatura ambiente máxima permitida del transmisor de nivel digital/analógico Level Plus® es de 71 ºC. Para evitar los efectos producidos por la temperatura del proceso y otros efectos térmicos, se debe tener cuidado para garantizar que el ambiente circundante y el ambiente dentro de la carcasa del transmisor no supere los 71 °C.
3. Algunos modelos contienen piezas no metálicas en la carcasa. Para evitar el riesgo de chispas electrostáticas sobre la superficie no metálica, la superficie se debe limpiar solo con un paño húmedo.
13.4.1.2 Etiquetas
Fig. 30: Etiqueta FMC de seguridad intrínseca, Modbus y DDA, carcasa NEMA
Fig. 31: Etiqueta FMC de seguridad intrínseca, HART®, carcasa NEMA
Fig. 32: Etiqueta FMC de seguridad intrínseca, Modbus y DDA, carcasa con cavidad individual y doble
Fig. 33: Etiqueta FMC de seguridad intrínseca, HART®, carcasa con cavidad individual y doble
1
1
2
2
A A
B B
REV ECO # DESCRIPTION
TITLE
SIZE DWG NO. REV
PRODUCT LINESCALE:
BY DATE
SHEET OF
UNLESS OTHERWISE SPECIFIEDTOLERANCES
0 PLACESMM
1 PLACEMM
ANGLES���� 0.5 � 0.1
- THREAD DEPTHS ARE TO MIN. FULL THDS- DRILL DEPTHS ARE TO FULL DIA.- REMOVE BURRS AND SHARP EDGES- DO NOT SCALE PRINT- MACHINED SURFACE FINISH 3.2uM [125 uIn]
PROPRIETARY DATATHE INFORMATION AND DESIGN(S) DISCLOSEDHEREIN ARE THE PROPERTY OF MTS SYSTEMSCORPORATION AND MAY NOT BE USED,REPRODUCED OR DISCLOSED IN ANY FORMEXCEPT AS GRANTED IN WRITING BY MTSSYSTEMS CORPORATION. THIS RESTRICTIONEXCLUDES INFORMATION THAT IS IN THE PUBLIC DOMAIN OR WAS LEGITIMATELY IN THEPRIOR POSSESSION OF THE RECIPIENT.
mMTS SYSTEMS CORPORATIONSENSORS DIVISION3001 SHELDON DRIVE, CARY, NC 27513
METRIC
FIRST ANGLE 551629-2 D
LEVEL1 2
(ACP) LABEL, LP, IS CANADA-DIGITAL
DRAWN BY: NJ
***NO REVISIONS SHALL BE MADE WITHOUT THE NOTIFICATION TO APPROVAL AGENCY(S).***
C 8037 ADDED FRENCH TRANSLATION DR 10/12/15B 7847 IP RATING WAS 66 NJ 12/02/14
1:1
D 8183 ADDED CL I, ZONE0/1 MS 8/18/16
INTRINSICALLY SAFECL. I, Div. 1, GR. ABCD CL.I, ZONE 0/1, Ex ia IIC T4 Ta = -50°C to +71°C ; IP66
when connected in accordance with FM approved installation drawing # 651543-2lorsqu'il est connecté en conformité avec FM approuvé le plan d'installation # 651543-2
WARNING: REFER TO INSTALLATION DRAWING FOR CAUTION/WARNINGSAVERTISSEMENT : se référer au schéma d'installation à la prudence / AVERTISSEMENTS
MTS Systems CorporationSensors Division3001 Sheldon Dr.Cary, NC 27513
Model No: Modèle No:
Serial No:Numéro de série:
Date:
R
8 POINT TEXT SIZE
MTS TO PRINTMODEL NO.SERIAL NO.
DATE CODE.
ENTITY PARAMETERS:SEE PRINT REFERENCE CHART
4.5 POINT TEXT SIZE
FM APPROVED
USE FM LOGO ARTWORK
C
Level Plus Transmitter
NOTES:
1. STANDARD LETTERING UNIVERS 55 OR ITC GARAMOND BOOK.
2. DIMENSIONS IN BRACKETS [ ] ARE IN INCHES.
3. MATERIAL: 3M 7883 METALLIZED POLYESTER FOIL W/GAS RESISTANT
P/N: 551629-2 Rev D
®
1
1
2
2
A A
B B
ECO # DESCRIPTION
C 8037 ADDED FRENCH TRANSLATION DR 10/12/15
***NO REVISIONS SHALL BE MADE WITHOUT THE NOTIFICATION TO APPROVAL AGENCY(S).***
(ACP) LABEL, LP, IS CANADA-ANALOGMTS SYSTEMS CORPORATIONSENSORS DIVISION3001 SHELDON DRIVE, CARY, NC 27513
B 7847 IP RATING WAS 66 NJ 12/02/14
PRODUCT LINE
FIRST ANGLE
mANGLES���
SIZE
LEVEL1:1 METRICSCALE:
DRAWN BY:
DWG NO.
1
DATEBY
2OF
D551641-2REV
SHEET
- THREAD DEPTHS ARE TO MIN. FULL THDS- DRILL DEPTHS ARE TO FULL DIA.- REMOVE BURRS AND SHARP EDGES- DO NOT SCALE PRINT- MACHINED SURFACE FINISH 3.2uM [125 uIn]
1 PLACEMM
� 0.1
0 PLACESMM
� 0.5
THE INFORMATION AND DESIGN(S) DISCLOSEDHEREIN ARE THE PROPERTY OF MTS SYSTEMSCORPORATION AND MAY NOT BE USED,REPRODUCED OR DISCLOSED IN ANY FORMEXCEPT AS GRANTED IN WRITING BY MTSSYSTEMS CORPORATION. THIS RESTRICTIONEXCLUDES INFORMATION THAT IS IN THE PUBLIC DOMAIN OR WAS LEGITIMATELY IN THEPRIOR POSSESSION OF THE RECIPIENT.
PROPRIETARY DATA TOLERANCESUNLESS OTHERWISE SPECIFIED TITLE
REV
D 8183 ADDED CL. I Zone 0/1 MS 8/8/16
WARNING: REFER TO INSTALLATION DRAWING FOR CAUTION/WARNINGSAVERTISSEMENT : se référer au schéma d'installation à la prudence / AVERTISSEMENTS
INTRINSICALLY SAFECL. I, Div. 1, GR. ABCD CL.I Zone 0/1 Ex ia IIC T4 Ta = -50°C to +71°C ; IP65
when connected in accordance with FM approvedinstallation drawing # 651544-2 lorsqu'il est connecté en conformité avec FM approuvéedessin d'installation # 651544-2
MTS Systems CorporationSensors Division3001 Sheldon Dr.Cary, NC 27513
Model No: Modèle No:
Serial No:Numéro de série:
Date:
R
USE MTS LOGOARTWORK
10 POINT SIZE
8 POINT TEXT SIZE
4.5 POINT TEXT SIZE
MTS TO PRINTMODEL NO.SERIAL NO.DATE CODE
ENTITY PARAMETERS:SEE PRINT REFERENCE CHART
4.5 POINT TEXT SIZE
FM APPROVED
USE FM LOGO ARTWORK
C
Level Plus Transmitter
P/N: 551641-2 Rev D
NOTES:
1. STANDARD LETTERING UNIVERS 55 OR ITC GARAMOND BOOK.
2. DIMENSIONS IN BRACKETS [ ] ARE IN INCHES.
3. MATERIAL: 3M 7883 METALLIZED POLYESTER FOIL W/GAS RESISTANT INK.
1.78 [.07]
1.78 [.07]
28.70 [1.13]
15.80 [.62]
34.69 [1.37]
86.30 [3.40]
69.85 [2.75]
R3.30 [.13]
®
1
1
2
2
A A
B B
551704-LEVEL
METRIC
(ACP) LABEL, LP, IS CANADA-ANALOGMTS SYSTEMS CORPORATIONSENSORS DIVISION3001 SHELDON DRIVE, CARY, NC 27513
FIRST ANGLE E- THREAD DEPTHS ARE TO MIN. FULL THDS
- DRILL DEPTHS ARE TO FULL DIA.- REMOVE BURRS AND SHARP EDGES- DO NOT SCALE PRINT- MACHINED SURFACE FINISH 3.2uM [125 uIn]
mTHE INFORMATION AND DESIGN(S) DISCLOSEDHEREIN ARE THE PROPERTY OF MTS SYSTEMSCORPORATION AND MAY NOT BE USED,REPRODUCED OR DISCLOSED IN ANY FORMEXCEPT AS GRANTED IN WRITING BY MTSSYSTEMS CORPORATION. THIS RESTRICTIONEXCLUDES INFORMATION THAT IS IN THE PUBLIC DOMAIN OR WAS LEGITIMATELY IN THEPRIOR POSSESSION OF THE RECIPIENT.
PROPRIETARY DATA
NJDRAWN BY:
REV
SHEET
DWG NO.
1:1 11 OF
TITLEUNLESS OTHERWISE SPECIFIED
ANGLES���
SIZE
SCALE:PRODUCT LINE
1 PLACEMM
TOLERANCES0 PLACES
MM� 0.1� 0.5
***NO REVISIONS SHALL BE MADE WITHOUT THE NOTIFICATION TO APPROVAL AGENCY(S).***
MTS Systems Corp. Sensors Division3001 Sheldon Drive, Cary, N.C. 27513
INTRINSICALLY SAFE: CL. I, Div. 1, GR. ABCD, CL.I Zone 0/1 Ex ia IIC T4Ta = -50°C TO +71°C ; IP65
REFER TO INSTALLATION DWG #651544-2 FOR CAUTION/WARNINGS WARNING: SUBSTITUTION OF COMPONENTS MAY IMPAIR INTRINSIC SAFETY
Avertissement : Se référer au document DWG # 651544-2 précautions d'installations ATTENTION : La substitution de composants peut compromettre la sécurité intrinsèque
LPXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XX-XX 35.05 [1.38]
"L1"∆ "L2"
17.53 [.69]
8.97 [.35]
3.47 [.14] R
FM C
NOTES:
1. STANDARD LETTERING UNIVERS 55 OR ITC GARAMOND BOOK.
2. MATERIAL TO BE SCREEN PRINTED ALUMINUM WITH SATIN BACKGROUND AND BLACK TEXT OR LASER ETCHED ALUMINUM.
3. ∆ INDICATES CRITICAL DIMENSIONS.
4. DIMENSIONS IN BRACKETS [ ] ARE IN INCHES.
5. MATERIAL: .8 [.03] THICK ALUMINUM.
6. REFER TO TABLE 1 FOR "L1" & "L2" DIMENSIONS.
APPROVED
�Level Plus Transmitter
P/N 551704-X Rev E
4.0 POINT TEXT SIZE (TYP.)
SEE TABLE 1 FOR DASH #
FM LOGO ARTWORK4.5 POINT TEXT SIZE
7.5 POINT SIZE
USE MTS LOGO ARTWORK14.0 POINT SIZE
SERIAL NO./DATE CODEMTS TO PRINT MODEL NO.
"D1"
TABLE 1
DASH # HOUSING "L1" "L2" "D1"
-1 ADALET85.85 [3.38]
69.85 [2.75]
Ø2.35 [.09]x2
-2 LIMATHERM 65 [2.56] 58 [2.28] Ø 3.05 [.12] x2
E 8256 ADDED "D1" MS 2/22/17D 8183 ADDED CL 1 ZONE 0/1 MS 8/8/16C 8037 ADDED FRENCH TRANSLATION DR 10/12/15
66 SAW GNITAR PI7487B NJ 12/2/14ETADYBNOITPIRCSED#OCEVER
1
1
2
2
A A
B B
551702-
***NO REVISIONS SHALL BE MADE WITHOUT THE NOTIFICATION TO APPROVAL AGENCY(S).***
LEVELMETRIC
(ACP) LABEL, LP, IS CANADA-DIGITALMTS SYSTEMS CORPORATIONSENSORS DIVISION3001 SHELDON DRIVE, CARY, NC 27513
FIRST ANGLE E- THREAD DEPTHS ARE TO MIN. FULL THDS
- DRILL DEPTHS ARE TO FULL DIA.- REMOVE BURRS AND SHARP EDGES- DO NOT SCALE PRINT- MACHINED SURFACE FINISH 3.2uM [125 uIn]
mTHE INFORMATION AND DESIGN(S) DISCLOSEDHEREIN ARE THE PROPERTY OF MTS SYSTEMSCORPORATION AND MAY NOT BE USED,REPRODUCED OR DISCLOSED IN ANY FORMEXCEPT AS GRANTED IN WRITING BY MTSSYSTEMS CORPORATION. THIS RESTRICTIONEXCLUDES INFORMATION THAT IS IN THE PUBLIC DOMAIN OR WAS LEGITIMATELY IN THEPRIOR POSSESSION OF THE RECIPIENT.
PROPRIETARY DATA
NJDRAWN BY:
REV
SHEET
DWG NO.
1:1 11 OF
TITLEUNLESS OTHERWISE SPECIFIED
ANGLES���
SIZE
SCALE:PRODUCT LINE
1 PLACEMM
TOLERANCES0 PLACES
MM� 0.1� 0.5
MTS Systems Corp. Sensors Division3001 Sheldon Drive, Cary, N.C. 27513
INTRINSICALLY SAFE: CL. I, Div. 1, GR. ABCD, CL. I Zone 0/1 Ex ia IIC T4 Ta = -50°C TO +71°C ; IP65
REFER TO INSTALLATION DWG #651543-2 FOR CAUTION/WARNINGS WARNING: SUBSTITUTION OF COMPONENTS MAY IMPAIR INTRINSIC SAFETY
Avertissement : Se référer au document DWG # 651543-2 précautions d'installations ATTENTION : La substitution de composants peut compromettre la sécurité intrinsèque
LPXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XX-XX 35.05 [1.38]
"L1"∆ "L2"
17.53 [.69]
8.97 [.35]
3.47 [.14] R
FM C
NOTES:
1. STANDARD LETTERING UNIVERS 55 OR ITC GARAMOND BOOK.
2. MATERIAL TO BE SCREEN PRINTED ALUMINUM WITH SATIN BACKGROUND AND BLACK TEXT OR LASER ETCHED ALUMINUM.
3. ∆ INDICATES CRITICAL DIMENSIONS.
4. DIMENSIONS IN BRACKETS [ ] ARE IN INCHES.
5. MATERIAL: .8 [.03] THICK ALUMINUM.
6. REFER TO TABLE 1 FOR "L1" & "L2" DIMENSIONS.
APPROVED
�Level Plus Transmitter
P/N 551702-X Rev E
4.0 POINT TEXT SIZE (TYP.)
SEE TABLE 1 FOR DASH #
FM LOGO ARTWORK4.5 POINT TEXT SIZE
7.5 POINT SIZE
USE MTS LOGO ARTWORK14.0 POINT SIZE
SERIAL NO./DATE CODEMTS TO PRINT MODEL NO.
"D1"
TABLE 1
DASH # HOUSING "L1" "L2" "D1"
-1 ADALET85.85 [3.38]
69.85[2.75]
Ø2.35 [.09]x2
-2 LIMATHERM 65 [2.56] 58 [2.28] Ø 3.05 [.12] x2
E 8256 ADDED "D1" MS 2/22/17D 8183 ADDED CL 1 ZONE 0/1 MS 8/8/16C 8037 ADDED FRENCH TRANSLATION DR 10/12/15
66 SAW GNITAR PI7487B NJ 12/2/14ETADYBNOITPIRCSED#OCEVER
Level Plus® CON COMPARTIMIENTOSManual de funcionamiento
I 32 I
13.4.1.3 Plano de instalación
Fig. 34: Diagrama de instalación FMC de seguridad intrínseca, Modbus y DDA, página 1
11
22
33
44
55
66
77
88
AA
BB
CC
DD
REV
ECO
#D
ESCR
IPTION
TITLE
SIZED
WG
NO
.R
EV
PRO
DU
CT LIN
ESC
ALE:
BYD
ATE
SHEET
OF
UN
LESS OTH
ERW
ISE SPECIFIED
TOLER
ANC
ES0 PLAC
ESM
M1 PLAC
EM
MAN
GLES
0.5
0.1
- THR
EAD
DEPTH
S ARE TO
MIN
. FULL TH
DS
- DR
ILL DEPTH
S ARE TO
FULL D
IA.
- REM
OV
E BU
RR
S AND
SHAR
P E
DG
ES- D
O N
OT SC
ALE PRIN
T- M
ACH
INED
SUR
FACE
FINISH
3.2uM [125 uIn]
PRO
PRIETAR
Y DATA
THE IN
FOR
MATIO
N AN
D D
ESIG
N(S) D
ISCLO
SEDH
ERE
IN AR
E THE PR
OPER
TY OF M
TS SYSTEMS
CO
RPO
RATIO
N AN
D M
AY NO
T BE USED
,R
EPRO
DU
CED
OR
DISC
LOSED
IN A
NY FO
RM
EXCEPT AS G
RAN
TED IN
WR
ITING
BY MTS
SYSTEMS C
OR
POR
ATIO
N. TH
IS RESTR
ICTIO
NEXC
LUD
ES INFO
RM
ATION
THA
T IS IN TH
E PU
BLIC D
OM
AIN O
R W
AS LEGITIM
ATELY IN TH
EPR
IOR
POSSES
SION
OF TH
E REC
IPIENT.
mM
TS SYSTEMS C
OR
POR
ATION
SENSO
RS D
IVISION
3001 SHELD
ON
DR
IVE, CAR
Y, NC
27513
METRIC
FIRST
ANG
LED
651543-2
1 3
DR
AWN
BY: M
S
***NO
REVISIO
NS SH
ALL BE MAD
E WITH
OU
T THE N
OTIFIC
ATION
TO APPR
OVAL AG
ENC
Y(S).**
G
C 7898 UPDATED TEMPERATURE ON NOTE 12 TO 71 C M
S 2/23/15D 8037 ADDED W
IRING CHART MS 11/3/15
E 8183 ADDED CL I Zone 0/1 MS 8/18/16
F 8256 UPDATED WIRING CHART ON SHEET 2 M
S 1/30/17G 8482 UPDATED BEND RADIUS TO 15" M
S 5/17/18
24 VDC
COMM
ON- >
Rx/Tx+
Rx /Tx-
GROUND
EARTH GROUND(SEE NOTE 4) TERRE( Voir note 4 )
EARTH GROUND(SEE NOTE 4) TERRE( Voir note 4 )
Rx/Tx-
Rx/Tx+
GND
+24V
SAFETY BARRIER Barrière de sécurité
SAFETY BARRIER Barrière de sécurité
SAFETY BARRIER Barrière de sécurité
NO
TES: (FOR
NO
TES IN FR
ENC
H SEE PAG
E 3, NO
TES POU
R VO
IR EN
FRAN
ÇAIS PAG
E 3) 1.ALL N
ATION
AL AND
LOC
AL CO
DES AN
D R
EGU
LATION
S MU
ST BE ADH
ERED
TO W
HEN
INSTALLIN
G TH
E LEVEL SENSO
R IN
HAZAR
DO
US EN
VIRO
NM
ENTS.
SEAL ALL CO
ND
UITS W
ITHIN
457 MM
(18"). 2.LO
OP C
ABLE MU
ST BE 24 AWG
TO 14 AW
G (.511M
M² to 1.6M
M²)
SHIELD
ED TW
ISTED PAIR
CABLE W
ITH SH
IELD. C
ABLE CAPAC
ITANC
E MU
ST BE LESS TH
AN 30 pF PER
FOO
T (98 pF PER M
). CABLE SH
IELD IS C
ON
NEC
TED TO
SYSTEM G
RO
UN
D IN
NO
N-H
AZARD
OU
S AREA. SEE IN
STALLATION
MAN
UAL FO
R
ADD
ITION
AL CABLE IN
FOR
MATIO
N.
3.THE R
ESISTANC
E BETWEEN
EARTH
GR
OU
ND
AND
THE IN
TRIN
SICALLY SAFE G
RO
UN
D M
UST BE LESS TH
AN 1 O
HM
. 4.TH
E TRAN
SDU
CER
FRAM
E SHALL BE G
RO
UN
DED
TO EAR
TH G
RO
UN
D D
IREC
TLY OR
THR
OU
GH
THE EQ
UIPM
ENT O
N W
HIC
H IT IS M
OU
NTED
. 5. C
ON
TRO
L EQU
IPMEN
T CO
NN
ECTED
TO ASSO
CIATED
APPARATU
S MU
ST N
OT U
SE OR
GEN
ERATE M
OR
E THAN
250 VRM
S OR
VDC
6.ASSOC
IATED APPAR
ATUS M
ANU
FACTU
RER
'S INSTALLATIO
N D
RAW
ING
MU
ST BE FO
LLOW
ED W
HEN
INSTALLIN
G TH
IS EQU
IPMEN
T. 7.O
NLY U
SE CEC
APPRO
VED BAR
RIER
S. 8.EN
TITY PARAM
ETERS:
SU
PPLY: Rx/Tx- : R
x/Tx+ : U
i = 28VDC
Ui= 8.6V U
i= 8.6V Ii = 100m
A Ii = 10mA Ii = 10m
A C
i = 0 µF Ci = 0 µF C
i = 0 µF Li = 0 µH
Li = 0 µH Li = 0 µH
Pi = 0.7 W Pi= 0.0215 W
P i= 0.0215 W 9.TH
E ENTITY C
ON
CEPT ALLO
WS IN
TERC
ON
NEC
TION
OF IN
TRIN
SICALLY SAFE APPAR
ATUS
WITH
ASSOC
IATED APPAR
ATUS W
HEN
THE FO
LLOW
ING
IS TRU
E: Vm
ax or Ui ≥ Voc, Vt or U
o; Im
ax or Ii ≥ Isc, It or Io; Pm
ax or Pi ≥ Po; C
a ≥ Ci + C
cable; La ≥ Li + Lcable. 10.D
UAL-C
AVITY ENC
LOSU
RES:
CU
STOM
ER C
ON
NEC
TION
S WILL BE M
ADE AT TER
MIN
AL BLOC
K ON
POW
ER SID
E O
F HO
USIN
G (N
OT TO
TERM
INAL BLO
CK O
N IN
TERC
ON
NEC
T BOAR
D).
11.FOR
INSTALLATIO
N W
ITHIN
CAN
ADA SEE, C
ANAD
IAN ELEC
TRIC
AL CO
DE,
CSA N
o. C22.1.
12.THE M
AXIMU
M PER
MITTED
AMBIEN
T TEMPER
ATUR
E OF TH
E LEVEL PLUS D
IGITAL/AN
ALOG
LEVEL TR
ANSM
ITTER IS 71 °C
. TO AVO
ID TH
E EFFECTS O
F PRO
CESS TEM
PERATU
RE AN
D
OTH
ER TH
ERM
AL EFFECTS C
ARE SH
ALL BE TAKEN TO
ENSU
RE TH
E SUR
RO
UN
DIN
G AM
BIENT
AND
THE AM
BIENT IN
SIDE TH
E TRAN
SMITTER
HO
USIN
G D
OES N
OT EXC
EED 71°C
13.CAU
TION
: FLEXIBLE GAU
GES H
AVE A MIN
IMU
M BEN
D R
ADIU
S OF 381M
M(15")
14.WAR
NIN
G: TH
E APPARATU
S ENC
LOSU
RE C
ON
TAINS ALU
MIN
UM
AND
IS CO
NSID
ERED
TO C
ON
STITUTE A PO
TENTIAL R
ISK OF IG
NITIO
N BY IM
PACT O
R FR
ICTIO
N. C
ARE M
UST BE TAKEN
IN
TO AC
CO
UN
T DU
RIN
G IN
STALLATION
AND
USE TO
PREVEN
T IMPAC
T OR
FRIC
TION
15.WAR
NIN
G: SU
BSTITUTIO
N O
F CO
MPO
NEN
TS MAY IM
PAIR IN
TRIN
SIC SAFETY.
16.WAR
NIN
G: TO
PREVEN
T IGN
ITION
OF FLAM
MABLE O
R C
OM
BUSTIBLE ATM
OSPH
ERES,
DISC
ON
NEC
T POW
ER BEFO
RE SER
VICIN
G
17.WAR
NIN
G: TH
E EQU
IPMEN
T CO
NTAIN
S NO
N-M
ETALLIC EN
CLO
SUR
E PARTS, TO
PREVEN
T TH
E RISK O
F ELECTR
OSTATIC
SPARKIN
G. TH
E NO
N-M
ETALLIC SU
RFAC
E SHO
ULD
ON
LY BE C
LEANED
WITH
A DAM
P CLO
TH.
NON HAZARDOUS LOCATION NON ZONE DANGEREUSE
HAZARDOUS LOCATION ZONE DANGEREUSE
AGEN
CY C
ON
TRO
LLED D
RAW
ING
(CAN
ADA). N
O C
HAN
GES W
ITHO
UT PR
IOR
AGEN
CY APPR
OVAL
AGEN
CE D
ESSIN contrôlée ( C
ANAD
A ) . AUC
UN
CH
ANG
EMEN
T sans l'accord préalable AGEN
CE APPR
OBATIO
N
EARTH TERMINAL
BORNE DE TERRE
(ACP) INSTALLATIN DWG LP DIGITAL
INTRINSICALLY SAFE FOR CANADA
LEVEL
FM
APPROVED
C
N/A
INTRINSICALLY SAFE (INTRINSÈQUEMENT SÛR)
CL. I, DIV. 1, GR. ABCDCL. I Zone 0/1 Ex ia IIC T4 Ta =
-50 to 71°C ; IP65
Level Plus® CON COMPARTIMIENTOSManual de funcionamiento
I 33 I
Fig. 35: Diagrama de instalación FMC de seguridad intrínseca, Modbus y DDA, página 2
DETAIL ASCALE 1.60 : 1
DETAIL CSCALE 3 : 1
DETAIL DSCALE 1.2
DETAIL ESCALE 1 : 1
A
C
D
E
11
22
33
44
55
66
77
88
AA
BB
CC
DD
REV
ECO
#D
ESCR
IPTION
TITLE
SIZED
WG
NO
.R
EV
PRO
DU
CT LIN
ESC
ALE:
BYD
ATE
SHEET
OF
UN
LESS OTH
ERW
ISE SPECIFIED
TOLER
ANC
ES0 PLAC
ESM
M1 PLAC
EM
MAN
GLES
0.5
0.1
- THR
EAD
DEPTH
S ARE TO
MIN
. FULL TH
DS
- DR
ILL DEPTH
S ARE TO
FULL D
IA.
- REM
OV
E BU
RR
S AND
SHAR
P E
DG
ES- D
O N
OT SC
ALE PRIN
T- M
ACH
INED
SUR
FACE
FINISH
3.2uM [125 uIn]
PRO
PRIETAR
Y DATA
THE IN
FOR
MATIO
N AN
D D
ESIG
N(S) D
ISCLO
SEDH
ERE
IN AR
E THE PR
OPER
TY OF M
TS SYSTEMS
CO
RPO
RATIO
N AN
D M
AY NO
T BE USED
,R
EPRO
DU
CED
OR
DISC
LOSED
IN A
NY FO
RM
EXCEPT AS G
RAN
TED IN
WR
ITING
BY MTS
SYSTEMS C
OR
POR
ATIO
N. TH
IS RESTR
ICTIO
NEXC
LUD
ES INFO
RM
ATION
THA
T IS IN TH
E PU
BLIC D
OM
AIN O
R W
AS LEGITIM
ATELY IN TH
EPR
IOR
POSSES
SION
OF TH
E REC
IPIENT.
mM
TS SYSTEMS C
OR
POR
ATION
SENSO
RS D
IVISION
3001 SHELD
ON
DR
IVE, CAR
Y, NC
27513
METRIC
FIRST
ANG
LED
651543-2
2 3
DR
AWN
BY: M
S
***NO
REVISIO
NS SH
ALL BE MAD
E WITH
OU
T THE N
OTIFIC
ATION
TO APPR
OVAL AG
ENC
Y(S).**
G
C 7898 UPDATED TEMPERATURE ON NOTE 12 TO 71 C M
S 2/23/15D 8037 ADDED W
IRING CHART MS 11/3/15
E 8183 ADDED CL I Zone 0/1 MS 8/18/16
F 8256 UPDATED WIRING CHART ON SHEET 2 M
S 1/30/17G 8482 UPDATED BEND RADIUS TO 15" M
S 5/17/18
+24V GNDEARTHTX/RX+TX/RX-
GND+24V
TX/RX-TX/RX+EARTH
GND+24V
TX/RX-
TX/RX+
EARTH
FIGU
RE 1
SING
LE CAVITY & N
EMA H
OU
SING
(Seule cavité & NEM
A LOG
EMEN
T)FIG
UR
E 2D
UAL C
AVITY HO
USIN
G(C
avité double LOG
EMEN
T)
NO
TES: 1. TH
E CU
STOM
ER SH
OU
LD C
ON
NEC
T THE O
UTSID
E GR
OU
ND
LUG
TO TH
E SAFETY EARTH
ING
GR
OU
ND
SYSTEM Le client doit relier la m
asse LUG
à l'extérieur pour le système au sol SÉC
UR
ITÉ DE TER
RE
WAR
NIN
G:
CO
ND
UIT SEALS R
EQU
IRED
WITH
IN 457 M
M (18") O
F HO
USIN
G.
Étanchéité des conduits requis dans les 457 mm
( 18 " ) DU
LOG
EMEN
T
(ACP) INSTALLATIN DWG LP DIGITAL
INTRINSICALLY SAFE FOR CANADA
+24V GND EARTH Tx/Rx+ Tx/Rx-
PIN WIRING CHART (FOR NEM
A GAGUE)
WIRING CHART (FOR NEM
A GAUGE)
LEVEL
WIRE COLOR
SIGNALRED
24 V PWR
BLACK 0 V PW
RBLUE
N/AW
HITERX TX +
GREENRX TX -
DRAIN WIRE
EARTH GROUND
PIN #SIGNAL
PIN 124 V PW
RPIN 2
0 V PWR
PIN 3N/A
PIN 4RX TX+
PIN 5RX TX-
PIN 6EARTH GROUND
Level Plus® CON COMPARTIMIENTOSManual de funcionamiento
I 34 I
Fig. 36: Diagrama de instalación FMC de seguridad intrínseca, Modbus y DDA, página 3
11
22
33
44
55
66
77
88
AA
BB
CC
DD
REV
ECO
#D
ESCR
IPTION
TITLE
SIZED
WG
NO
.R
EV
PRO
DU
CT LIN
ESC
ALE:
BYD
ATE
SHEET
OF
UN
LESS OTH
ERW
ISE SPECIFIED
TOLER
ANC
ES0 PLAC
ESM
M1 PLAC
EM
MAN
GLES
0.5
0.1
- THR
EAD
DEPTH
S ARE TO
MIN
. FULL TH
DS
- DR
ILL DEPTH
S ARE TO
FULL D
IA.
- REM
OV
E BU
RR
S AND
SHAR
P E
DG
ES- D
O N
OT SC
ALE PRIN
T- M
ACH
INED
SUR
FACE
FINISH
3.2uM [125 uIn]
PRO
PRIETAR
Y DATA
THE IN
FOR
MATIO
N AN
D D
ESIG
N(S) D
ISCLO
SEDH
ERE
IN AR
E THE PR
OPER
TY OF M
TS SYSTEMS
CO
RPO
RATIO
N AN
D M
AY NO
T BE USED
,R
EPRO
DU
CED
OR
DISC
LOSED
IN A
NY FO
RM
EXCEPT AS G
RAN
TED IN
WR
ITING
BY MTS
SYSTEMS C
OR
POR
ATIO
N. TH
IS RESTR
ICTIO
NEXC
LUD
ES INFO
RM
ATION
THA
T IS IN TH
E PU
BLIC D
OM
AIN O
R W
AS LEGITIM
ATELY IN TH
EPR
IOR
POSSES
SION
OF TH
E REC
IPIENT.
mM
TS SYSTEMS C
OR
POR
ATION
SENSO
RS D
IVISION
3001 SHELD
ON
DR
IVE, CAR
Y, NC
27513
METRIC
FIRST
ANG
LED
651543-2
3 3
DR
AWN
BY: M
S
***NO
REVISIO
NS SH
ALL BE MAD
E WITH
OU
T THE N
OTIFIC
ATION
TO APPR
OVAL AG
ENC
Y(S).**
G
C 7898 UPDATED TEMPERATURE ON NOTE 12 TO 71 C M
S 2/23/15D 8037 ADDED W
IRING CHART MS 11/3/15
E 8183 ADDED CL I Zone 0/1 MS 8/18/16
F 8256 UPDATED WIRING CHART ON SHEET 2 M
S 1/30/17G 8482 UPDATED BEND RADIUS TO 15" M
S 5/17/18
NO
TES:1. La réglem
entation doit être respectée suivant les codes locaux et nationaux LO
RS D
'INSTALLATIO
N D
U C
APTEUR
DE N
IVEAU D
ANS D
ES ENVIR
ON
NEM
ENTS D
ANG
EREU
X.Sceller tous les conduits à m
oins de 457 mm
(18 " ). 2. Boucle de câble doit être de 24 AW
G à 14 AW
G (.511M
M2 à 1.6M
M2)
Paire Torsadée Blindée avec le bouclier. La capacité du câble devraÊtre inférieure à 30 pF PAR
PIED (98 pF PAR
M). Le blindage du câble est raccordé
À la terre EN ZO
NE N
ON
DAN
GER
EUSE. VO
IR m
anuel d'installationIN
FOR
MATIO
NS de câble supplém
entaire. 3. La résistance entre la TER
RE ET la zone IN
TRIN
SEQU
ED
oit être inférieure à 1 ohm.
4. Le boîtier du capteur doit être relié à la TERR
E directement ou par
L'équipement sur lequel il est m
onté. 5. Equipem
ent de comm
ande relié à l'appareil associé ne doit pas utiliser ou générer plus de 250 VRM
S OU
VDC
6 Le plan d'installation associé du fabricant de l'appareil doit être suivi lors de l'installation de cet équipement
7. UTILISER
UN
IQU
EMEN
T DES BAR
RIER
ES APPRO
UVÉES C
EC.
8. PARAM
ÈTRES :
SUPPLY: R
x/Tx- : Rx/Tx+ :
Ui = 28VD
C U
i= 8.6V Ui= 8.6V
Ii = 100mA Ii = 10m
A Ii = 10mA
Ci = 0 µF C
i = 0 µF Ci = 0 µF
Li = 0 µH Li = 0 µH
Li = 0 µHPi = 0.7 W
Pi= 0.0215 W Pi= 0.0215 W
9. Le concept de l'entité permet l'interconnexion de l'appareil de sécurité intrinsèque avec un appareil associé lorsque la suivante est vraie :
Vmax or U
i > Voc, Vt or Uo;
Imax or Ii > Isc, It or Io;
Pmax or Pi > Po;
Ca > C
i + Ccable;
La > Li + Lcable. 10. EN
CEIN
TES à cavité double : Les raccordements clients, seront effectués au bornier d'alim
entation sur le côté du LOG
EMEN
T boîtier (pas au bornier carte d'interconnexion) 11. Pour une IN
STALLATION
AU C
ANAD
A, suivre LE CO
DE C
ANAD
IEN D
E L'ÉLECTR
ICITÉ,
CSA N
o C22.1.
12. La TEMPÉR
ATUR
E AMBIAN
TE maxim
um autorisé pour le capteur LEVEL PLU
S version DIG
ITAL ou ANALO
GIQ
UE est de 71 C
°. Pour éviter les effets de la tem
pérature sur le processus des protections thermiques doivent être prises pour assurer la tem
pérature ambiante environnante et ainsi qu'à l'intérieur
du boîtier du capteur la température ne doit pas dépasser 71 C
° 13. ATTEN
TION
: Le flexible du capteur a un rayon minim
um de courbure de 381 m
m (15 ")
14. ATTENTIO
N : Le boîtier de l'appareil contient de l'alum
inium et est considéré
CO
NSTITU
ER U
N R
ISQU
E potentiel de générer des étincelles en cas de choc ou de frottement. VEU
ILLEZ EN TEN
IR C
OM
PTE LOR
S DE
L'INSTALLATIO
N ET U
TILISATION
POU
R ÉVITER
choc ou frottement
15. ATTENTIO
N : La substitution de com
posants peut comprom
ettre la sécurité intrinsèque. 16. ATTEN
TION
: Pour éviter l'inflamm
ation d'atmosphères inflam
mables ou com
bustibles,D
ÉBRAN
CH
EZ L'ALIMEN
TATION
AVANT D
'INTER
VENIR
17. ATTENTIO
N : l'équipem
ent contient DES PIEC
ES NO
N M
ETALLIQU
E, POU
R EVITER
LE RISQ
UE ÉLEC
TRO
STATIQU
E, étincelles. La surface non métallique doit SEU
LEMEN
T Être nettoyée avec un chiffon humid
(ACP) INSTALLATIN DWG LP DIGITAL
INT RINSICALLY SAFE FOR CANADA
LEVEL
Level Plus® CON COMPARTIMIENTOSManual de funcionamiento
I 35 I
Fig. 37: Diagrama de instalación FMC de seguridad intrínseca, HART®, página 1
11
22
33
44
55
66
77
88
AA
BB
CC
DD
REV
ECO
#D
ESCR
IPTION
TITLE
SIZED
WG
NO
.R
EV
PRO
DU
CT LIN
ESC
ALE:
BYD
ATE
SHEET
OF
UN
LESS OTH
ERW
ISE SPECIFIED
TOLER
ANC
ES0 PLAC
ESM
M1 PLAC
EM
MAN
GLES
0.5
0.1
- THR
EAD
DEPTH
S ARE TO
MIN
. FULL TH
DS
- DR
ILL DEPTH
S ARE TO
FULL D
IA.
- REM
OV
E BU
RR
S AND
SHAR
P E
DG
ES- D
O N
OT SC
ALE PRIN
T- M
ACH
INED
SUR
FACE
FINISH
3.2uM [125 uIn]
PRO
PRIETAR
Y DATA
THE IN
FOR
MATIO
N AN
D D
ESIG
N(S) D
ISCLO
SEDH
ERE
IN AR
E THE PR
OPER
TY OF M
TS SYSTEMS
CO
RPO
RATIO
N AN
D M
AY NO
T BE USED
,R
EPRO
DU
CED
OR
DISC
LOSED
IN A
NY FO
RM
EXCEPT AS G
RAN
TED IN
WR
ITING
BY MTS
SYSTEMS C
OR
POR
ATIO
N. TH
IS RESTR
ICTIO
NEXC
LUD
ES INFO
RM
ATION
THA
T IS IN TH
E PU
BLIC D
OM
AIN O
R W
AS LEGITIM
ATELY IN TH
EPR
IOR
POSSES
SION
OF TH
E REC
IPIENT.
mM
TS SYSTEMS C
OR
POR
ATION
SENSO
RS D
IVISION
3001 SHELD
ON
DR
IVE, CAR
Y, NC
27513
METRIC
FIRST
ANG
LED
651544-2LEVEL
1 3
DR
AWN
BY: M
S
***NO
REVISIO
NS SH
ALL BE MAD
E WITH
OU
T THE N
OTIFIC
ATION
TO APPR
OVAL AG
ENC
Y(S).**
G
C 7898 UPDATED TEMPERATURE ON NOTE 12 TO 71 C M
S 2/23/15D 8037 ADDED W
IRING CHART MS 11/3/15
E 8183 ADDED CL I Zone 0/1 MS 8/18/16
F 8256 UPDATED WIRING CHART ON SHEET 2 M
S 1/30/17G 8482 UPDATED BEND RADIUS TO 15" M
S 5/17/18
NO
N H
AZARD
OU
S LOC
ATION
NO
N ZO
NE D
ANG
EREU
SEH
AZARD
OU
S LOC
ATION
ZON
E DAN
GER
EUSE
NO
TES: (FOR
NO
TES IN FR
ENC
H SEE PAG
E 3, NO
TES POU
R VO
IR EN
FRAN
��
AIS PAGE 3)
1. ALL NATIO
NAL AN
D LO
CAL C
OD
ES AND
REG
ULATIO
NS M
UST BE AD
HER
ED TO
WH
EN IN
STALLING
THE M
TS LP SENSO
R IN
HAZAR
DO
US EN
VIRO
NM
ENTS.
SEAL ALL CO
ND
UITS W
ITHIN
457 MM
(18"). 2. LO
OP C
ABLE MU
ST BE 24 AWG
TO 14 AW
G (.511M
M² to 1.6M
M²)
SHIELD
ED TW
ISTED PAIR
CABLE W
ITH SH
IELD. C
ABLE CAPAC
ITANC
E MU
ST BE LESS TH
AN 30 pF PER
FOO
T (98 pF PER m
). CABLE SH
IELD IS C
ON
NEC
TED TO
SYSTEM G
RO
UN
D IN
NO
N-H
AZARD
OU
S AREA. SEE IN
STALLATION
MAN
UAL FO
R
ADD
ITION
AL CABLE IN
FOR
MATIO
N.
3. THE R
ESISTANC
E BETWEEN
EARTH
GR
OU
ND
AND
THE IN
TRIN
SICALLY SAFE G
RO
UN
D M
UST BE LESS TH
AN 1 O
HM
. 4. TH
E TRAN
SDU
CER
FRAM
E SHALL BE G
RO
UN
DED
TO EAR
TH G
RO
UN
D D
IREC
TLY OR
THR
OU
GH
THE EQ
UIPM
ENT O
N W
HIC
H IT IS M
OU
NTED
. 5. C
ON
TRO
L EQU
IPMEN
T CO
NN
ECTED
TO ASSO
CIATED
APPARATU
S MU
ST N
OT U
SE OR
GEN
ERATE M
OR
E THAN
250 VRM
S OR
VDC.
6. ASSOC
IATED APPAR
ATUS M
ANU
FACTU
RER
'S INSTALLATIO
N D
RAW
ING
MU
ST BE FO
LLOW
ED W
HEN
INSTALLIN
G TH
IS EQU
IPMEN
T 7. O
NLY U
SE CEC
APPRO
VED BAR
RIER
S. 8. APPR
OVED
LOO
P SEPARATIO
N M
ETHO
DS:
*RU
N LO
OPS IN
SEPARATE C
ABLES *R
UN
LOO
PS IN SEPAR
ATE GR
OU
ND
ED SH
IELDS
9. ENTITY PAR
AMETER
S EACH
LOO
P: U
i = 28 VDC
Ii = 120 mA
Ci = 0 µF
Li = 5 µH Pi = 840 m
W 10. D
UAL-C
AVITY ENC
LOSU
RES:
CU
STOM
ER C
ON
NEC
TION
S WILL BE M
ADE AT TER
MIN
AL BLOC
K ON
POW
ER SID
E O
F HO
USIN
G (N
OT TO
TERM
INAL BLO
CK O
N IN
TERC
ON
NEC
T BOAR
D)
11 FOR
INSTALLATIO
N W
ITHIN
CAN
ADA, SEE C
AN
ADIAN
ELECTR
ICAL C
OD
E, CSA N
o C22.1.
12.THE M
AXIMU
M PER
MITTED
AMBIEN
T TEMPER
ATUR
E OF TH
E LEVEL PLUS D
IGITAL/AN
ALOG
LEVEL TR
ANSM
ITTER IS 71 °C
. TO AVO
ID TH
E EFFECTS O
F PRO
CESS TEM
PERATU
RE AN
D
OTH
ER TH
ERM
AL EFFECTS C
ARE SH
ALL BE TAKEN TO
ENSU
RE TH
E SUR
RO
UN
DIN
G AM
BIENT
AND
THE AM
BIENT IN
SIDE TH
E TRAN
SMITTER
HO
USIN
G D
OES N
OT EXC
EED 71°C
13.CAU
TION
: FLEXIBLE GAU
GES H
AVE A MIN
IMU
M BEN
D R
ADIU
S OF 381M
M(15")
14. WAR
NIN
G: TH
E APPARATU
S ENC
LOSU
RE C
ON
TAINS ALU
MIN
UM
AND
IS CO
NSID
ERED
TO C
ON
STITUTE A PO
TENTIAL R
ISK OF IG
NITIO
N BY IM
PACT O
R FR
ICTIO
N. C
ARE M
UST BE TAKEN
IN
TO AC
CO
UN
T DU
RIN
G IN
STALLATION
AND
USE TO
PREVEN
T IMPAC
T OR
FRIC
TION
15.WAR
NIN
G: SU
BSTITUTIO
N O
F CO
MPO
NEN
TS MAY IM
PAIR IN
TRIN
SIC SAFETY.
16.WAR
NIN
G: TO
PREVEN
T IGN
ITION
OF FLAM
MABLE O
R C
OM
BUSTIBLE ATM
OSPH
ERES
. D
ISCO
NN
ECT PO
WER
BEFOR
E SERVIC
ING
. 17.W
ARN
ING
: THE EQ
UIPM
ENT C
ON
TAINS N
ON
-METALLIC
ENC
LOSU
RE PAR
TS, TO PR
EVENT
THE R
ISK OF ELEC
TRO
STATIC SPAR
KING
. THE N
ON
-METALLIC
SUR
FACE SH
OU
LD O
NLY
BE CLEAN
ED W
ITH A D
AMP C
LOTH
.
EARTH
GR
OU
ND
LUG
NO
TE 3
AGEN
CY C
ON
TRO
LLED D
RAW
ING
(Canada). N
O C
HAN
GES W
ITHO
UT PR
IOR
AGEN
CY APPR
OVAL
AGEN
CE D
ESSIN contrôlée ( C
ANAD
A ) . AUC
UN
CH
ANG
EMEN
T sans l'accord préalable AGEN
CE APPR
OBATIO
N
24 VDC
CO
NTR
OL
INPU
T 1
CO
NTR
OL
INPU
T 2
APPRO
VED SAFETY
BARR
IER sécurité approuvé BAR
RIÈR
ELO
OP VO
LTAGE
SHIELD
SHIELD
LOO
P 1+
LOO
P 1-
LOO
P 2+
LOO
P 2-
FM
APPROVED
C
(ACP) INSTALLATIN DWG LP ANALOG
INTRINSICALLY SAFE FOR CANADA
SING
LE OR
DU
AL CAVITY
NEM
A HO
USIN
G
F
INTRINSICALLY SAFECL. I, DIV. 1, GR. ABCDCL.I Zone 0/1 Ex ia IIC T4Ta =
-50 to 71°C ; IP65
APPRO
VED SAFETY
BARR
IER sécurité approuvé BAR
RIÈR
E
EARTH GROUND(SEE NOTE 4) TERRE( Voir note 4 )
EARTH GROUND(SEE NOTE 4) TERRE( Voir note 4 )
Level Plus® CON COMPARTIMIENTOSManual de funcionamiento
I 36 I
Fig. 38: Diagrama de instalación FMC de seguridad intrínseca, HART®, página 2
DETAIL D
SCALE 3
DETAIL E
SCALE 1.60
DETAIL F
SCALE 1.2
DETAIL H
SCALE 1 : 1
D
E
F
H
11
22
33
44
55
66
77
88
AA
BB
CC
DD
REV
ECO
#D
ESCR
IPTION
TITLE
SIZED
WG
NO
.R
EV
PRO
DU
CT LIN
ESC
ALE:
BYD
ATE
SHEET
OF
UN
LESS OTH
ERW
ISE SPECIFIED
TOLER
ANC
ES0 PLAC
ESM
M1 PLAC
EM
MAN
GLES
0.5
0.1
- THR
EAD
DEPTH
S ARE TO
MIN
. FULL TH
DS
- DR
ILL DEPTH
S ARE TO
FULL D
IA.
- REM
OV
E BU
RR
S AND
SHAR
P E
DG
ES- D
O N
OT SC
ALE PRIN
T- M
ACH
INED
SUR
FACE
FINISH
3.2uM [125 uIn]
PRO
PRIETAR
Y DATA
THE IN
FOR
MATIO
N AN
D D
ESIG
N(S) D
ISCLO
SEDH
ERE
IN AR
E THE PR
OPER
TY OF M
TS SYSTEMS
CO
RPO
RATIO
N AN
D M
AY NO
T BE USED
,R
EPRO
DU
CED
OR
DISC
LOSED
IN A
NY FO
RM
EXCEPT AS G
RAN
TED IN
WR
ITING
BY MTS
SYSTEMS C
OR
POR
ATIO
N. TH
IS RESTR
ICTIO
NEXC
LUD
ES INFO
RM
ATION
THA
T IS IN TH
E PU
BLIC D
OM
AIN O
R W
AS LEGITIM
ATELY IN TH
EPR
IOR
POSSES
SION
OF TH
E REC
IPIENT.
mM
TS SYSTEMS C
OR
POR
ATION
SENSO
RS D
IVISION
3001 SHELD
ON
DR
IVE, CAR
Y, NC
27513
METRIC
FIRST
ANG
LED
651544-2LEVEL
2 3
DR
AWN
BY: M
S
***NO
REVISIO
NS SH
ALL BE MAD
E WITH
OU
T THE N
OTIFIC
ATION
TO APPR
OVAL AG
ENC
Y(S).**
G
C 7898 UPDATED TEMPERATURE ON NOTE 12 TO 71 C M
S 2/23/15D 8037 ADDED W
IRING CHART MS 11/3/15
E 8183 ADDED CL I Zone 0/1 MS 8/18/16
F 8256 UPDATED WIRING CHART ON SHEET 2 M
S 1/30/17G 8482 UPDATED BEND RADIUS TO 15" M
S 5/17/18
LOOP 2-
LOOP 2+
EARTH
LOOP 1-
LOOP 1+
NO
TES: 1. TH
E CU
STOM
ER SH
OU
LD C
ON
NEC
T THE O
UTSID
E GR
OU
ND
LUG
TO TH
E SAFETY EARTH
ING
GR
OU
ND
SYSTEM Le client doit relier la m
asse LUG
à l'extérieur pour le système au sol SÉC
UR
ITÉ DE TER
RE
WAR
NIN
G:
CO
ND
UIT SEALS R
EQU
IRED
WITH
IN 457 M
M (18") O
F HO
USIN
G.
Étanchéité des conduits requis dans les 457 mm
( 18 " ) DU
LOG
EMEN
T.
FIGU
RE 2
DU
AL CAVITY H
OU
SING
LOOP 1+ LOOP 1- EARTH LOOP 2+ LOOP 2-
FIGU
RE 1
SING
LE CAVITY & N
EMA H
OU
SING
LOOP 1+ LOOP 1- EARTH LOOP 2+ LOOP 2-
LOOP 1+ LOOP 1- EARTH LOOP 2+ LOOP 2-
F
PIN WIRING CHART (FOR NEM
A GAUGE)
WIRING CHART(FOR NEM
A GAUGE)
(ACP) INSTALLATIN DWG LP ANALOG
INTRINSICALLY SAFE FOR CANADA
WIRE COLOR
SIGNALRED
LOOP 1+BLACK
LOOP 1-BLUE
LOOP 2-W
HITELOOP 2+
GREENN/A
DRAIN WIRE
EARTH GROUND
PIN #SIGNAL
PIN 1LOOP 1-
PIN 2LOOP 1+
PIN 3LOOP 2-
PIN 4LOOP 2+
PIN 5N/A
PIN 6EARTH GROUND
Level Plus® CON COMPARTIMIENTOSManual de funcionamiento
I 37 I
Fig. 39: Diagrama de instalación FMC de seguridad intrínseca, HART®, página 3
11
22
33
44
55
66
77
88
AA
BB
CC
DD
REV
ECO
#D
ESCR
IPTION
TITLE
SIZED
WG
NO
.R
EV
PRO
DU
CT LIN
ESC
ALE:
BYD
ATE
SHEET
OF
UN
LESS OTH
ERW
ISE SPECIFIED
TOLER
ANC
ES0 PLAC
ESM
M1 PLAC
EM
MAN
GLES
0.5
0.1
- THR
EAD
DEPTH
S ARE TO
MIN
. FULL TH
DS
- DR
ILL DEPTH
S ARE TO
FULL D
IA.
- REM
OV
E BU
RR
S AND
SHAR
P E
DG
ES- D
O N
OT SC
ALE PRIN
T- M
ACH
INED
SUR
FACE
FINISH
3.2uM [125 uIn]
PRO
PRIETAR
Y DATA
THE IN
FOR
MATIO
N AN
D D
ESIG
N(S) D
ISCLO
SEDH
ERE
IN AR
E THE PR
OPER
TY OF M
TS SYSTEMS
CO
RPO
RATIO
N AN
D M
AY NO
T BE USED
,R
EPRO
DU
CED
OR
DISC
LOSED
IN A
NY FO
RM
EXCEPT AS G
RAN
TED IN
WR
ITING
BY MTS
SYSTEMS C
OR
POR
ATIO
N. TH
IS RESTR
ICTIO
NEXC
LUD
ES INFO
RM
ATION
THA
T IS IN TH
E PU
BLIC D
OM
AIN O
R W
AS LEGITIM
ATELY IN TH
EPR
IOR
POSSES
SION
OF TH
E REC
IPIENT.
mM
TS SYSTEMS C
OR
POR
ATION
SENSO
RS D
IVISION
3001 SHELD
ON
DR
IVE, CAR
Y, NC
27513
METRIC
FIRST
ANG
LED
651544-2LEVEL
3 3
DR
AWN
BY: M
S
***NO
REVISIO
NS SH
ALL BE MAD
E WITH
OU
T THE N
OTIFIC
ATION
TO APPR
OVAL AG
ENC
Y(S).**
G
C 7898 UPDATED TEMPERATURE ON NOTE 12 TO 71 C M
S 2/23/15D 8037 ADDED W
IRING CHART MS 11/3/15
E 8183 ADDED CL I Zone 0/1 MS 8/18/16
F 8256 UPDATED WIRING CHART ON SHEET 2 M
S 1/30/17G 8482 UPDATED BEND RADIUS TO 15" M
S 5/17/18
NO
TES:1. La réglem
entation doit être respectée suivant les codes locaux et nationaux LO
RS D
'INSTALLATIO
N D
U C
APTEUR
DE N
IVEAU D
ANS D
ES ENVIR
ON
NEM
ENTS D
ANG
EREU
X.Sceller tous les conduits à m
oins de 457 mm
(18 " ). 2. Boucle de câble doit être de 24 AW
G à 14 AW
G (.511M
M2 à 1.6M
M2)
Paire Torsadée Blindée avec le bouclier. La capacité du câble devraÊtre inférieure à 30 pF PAR
PIED (98 pF PAR
M). Le blindage du câble est raccordé
À la terre EN ZO
NE N
ON
DAN
GER
EUSE. VO
IR m
anuel d'installationIN
FOR
MATIO
NS de câble supplém
entaire. 3. La résistance entre la TER
RE ET la zone IN
TRIN
SEQU
ED
oit être inférieure à 1 ohm.
4. Le boîtier du capteur doit être relié à la TERR
E directement ou par
L'équipement sur lequel il est m
onté. 5. Equipem
ent de comm
ande relié à l'appareil associé ne doit pas utiliser ou générer plus de 250 VRM
S OU
VDC
6 Le plan d'installation associé du fabricant de l'appareil doit être suivi lors de l'installation de cet équipement
7. UTILISER
UN
IQU
EMEN
T DES BAR
RIER
ES APPRO
UVÉES C
EC 8. approuvent les m
éthodes de séparation Loop: * BO
UC
LES RU
N dans des câbles séparés
* BOU
CLES R
UN
Shields terre séparés 9. Param
ètres d'entité chaque boucle: U
i = 28 VDC
Ii = 120 mA
Ci = 0 µF
Li = 5 µH Pi = 840 m
W 10. EN
CEIN
TES à cavité double : Les raccordements clients, seront effectués au bornier d'alim
entation sur le côté du LO
GEM
ENT boîtier (pas au bornier carte d'interconnexion)
11. Pour une INSTALLATIO
N AU
CAN
ADA, suivre LE C
OD
E CAN
ADIEN
DE L'ÉLEC
TRIC
ITÉ,C
SA No C
22.1. 12. La TEM
PÉRATU
RE AM
BIANTE m
aximum
autorisé pour le capteur LEVEL PLUS version D
IGITAL ou
ANALO
GIQ
UE est de 71 C
°. Pour éviter les effets de la température sur le processus des protections therm
iques doivent être prises pour assurer la tem
pérature ambiante environnante et ainsi qu'à l'intérieur du boîtier du capteur la
température ne doit pas dépasser 71 C
° 13. ATTEN
TION
: Le flexible du capteur a un rayon minim
um de courbure de 381m
m (15 ")
14. ATTENTIO
N : Le boîtier de l'appareil contient de l'alum
inium et est considéré
CO
NSTITU
ER U
N R
ISQU
E potentiel de générer des étincelles en cas de choc ou de frottement. VEU
ILLEZ EN TEN
IR
CO
MPTE LO
RS D
E L'INSTALLATIO
N ET U
TILISATION
POU
R ÉVITER
choc ou frottement
15. ATTENTIO
N : La substitution de com
posants peut comprom
ettre la sécurité intrinsèque. 16. ATTEN
TION
: Pour éviter l'inflamm
ation d'atmosphères inflam
mables ou com
bustibles,D
ÉBRAN
CH
EZ L'ALIMEN
TATION
AVANT D
'INTER
VENIR
17. ATTENTIO
N : l'équipem
ent contient DES PIEC
ES NO
N M
ETALLIQU
E, POU
R EVITER
LE RISQ
UE ÉLEC
TRO
STATIQU
E, étincelles. La surface non métallique doit SEU
LEMEN
T Être nettoyée avec un chiffon hum
id
F
(ACP) INSTALLATIN DWG LP ANALOG
INTRINSICALLY SAFE FOR CANADA
Level Plus® CON COMPARTIMIENTOSManual de funcionamiento
I 38 I
13.4.2 Resistente a explosiones/ignífugo
13.4.2.1 Condiciones específicas para un uso seguro
1. Advertencia: El equipo contiene piezas no metálicas de la carcasa y de proceso para evitar el riesgo de chispas electrostáticas. La superficie no metálica se debe limpiar solo con un paño húmedo. La superficie pintada del equipo puede almacenar carga electrostática y convertirse en fuente de ignición en aplicaciones con una humedad relativa baja con <~30% de humedad relativa donde la superficie pintada está relativamente libre de contaminación (suciedad, polvo o aceite). La limpieza de la superficie pintada solo debe hacerse con un paño húmedo.
2. Los cables deben tener una clasificación de uso de > 5 °C por encima de la temperatura ambiente máxima.
3. Para mantener la clasificación de protección de IP65, se debe usar cinta Teflon™ (3 vueltas) o grasa para tubería. Consulte las instrucciones de instalación.
4. El equipo se puede instalar en la pared que separa un área EPL Ga y el área menos peligrosa, EPL Gb. En esta configuración, la conexión de proceso se instala en EPL Ga, mientras que la carcasa del transmisor se instala en EPL Gb. Consulte las instrucciones de instalación.
5. Los medidores flexibles cuentan con un radio mínimo de curvatura de 381 mm (15 in).
6. La trayectoria de la flama no es para reparación. 7. La clase de temperatura, el rango de temperatura ambiente y el
rango de temperatura del proceso aplicables del equipo son las que siguen:• T3 con rango de temperatura del proceso de −40 °C a +150 °C• T4 con rango de temperatura del proceso de −40 °C a +135 °C• T5 con rango de temperatura del proceso de −40 °C a +100 °C• T6 con rango de temperatura del proceso de −40 °C a +85 °C• El rango de temperatura ambiente es −40 °C ≤ Ta ≤ 71 °C
8. Durante el montaje del MLG (medidor de nivel magnético), asegúrese de que el cabezal electrónico y la barrera de presión cuenten con un espaciado de al menos 5 pulgadas. Consulte el Manual de instalación para obtener más información.
Fig. 40: Resistente a explosiones, etiqueta FMC, Modbus o DDA opción de carcasa G, H o L
Fig. 41: Resistente a explosiones, etiqueta FMC, Modbus o DDA, opción de carcasa D, E
Fig. 42: Resistente a explosiones, etiqueta FMC, HART®, opción de carcasa G, H o L
Fig. 43: Resistente a explosiones, etiqueta FMC, HART®, opción de carcasa D, E
1
1
2
2
A A
B B
REV ECO # DESCRIPTION
TITLE
SIZE DWG NO. REV
PRODUCT LINESCALE:
BY DATE
SHEET OF
UNLESS OTHERWISE SPECIFIEDTOLERANCES
0 PLACESMM
1 PLACEMM
ANGLES� � �� 0.5 � 0.1
- THREAD DEPTHS ARE TO MIN. FULL THDS- DRILL DEPTHS ARE TO FULL DIA.- REMOVE BURRS AND SHARP EDGES- DO NOT SCALE PRINT- MACHINED SURFACE FINISH 3.2uM [125 uIn]
PROPRIETARY DATATHE INFORMATION AND DESIGN(S) DISCLOSEDHEREIN ARE THE PROPERTY OF MTS SYSTEMSCORPORATION AND MAY NOT BE USED,REPRODUCED OR DISCLOSED IN ANY FORMEXCEPT AS GRANTED IN WRITING BY MTSSYSTEMS CORPORATION. THIS RESTRICTIONEXCLUDES INFORMATION THAT IS IN THE PUBLIC DOMAIN OR WAS LEGITIMATELY IN THEPRIOR POSSESSION OF THE RECIPIENT.
mMTS SYSTEMS CORPORATIONSENSORS DIVISION3001 SHELDON DRIVE, CARY, NC 27513
METRIC
FIRST ANGLE A 551706-x A
1 1
DRAWN BY: MS
***NO REVISIONS SHALL BE MADE WITHOUT THE NOTIFICATION TO APPROVAL AGENCY(S).***A MS 7/28/16
MTS Systems CorporationSensors Division3001 Sheldon Drive, Cary, N.C. 27513
Level Plus Transmitter�
FM16CA0130X
INSTALL PER # 651552-2MAX. PRESSURE 1000 PSI (RIGID SENSOR)MAX. PRESSURE 435 PSI (FLEX SENSOR)INPUT: 28V (120mA)max OUTPUT: RS485
WARNING: DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE IS PRESENT. FOR ZONE INSTALLATIONS, A SEAL SHALL BE INSTALLED WITHIN 50mm OF THE ENCLOSURE. FOR DIVISION INSTALLATIONS A SEAL SHALL BE INSTALLED WITHIN 18 INCHESOF THE ENCLOSURE ATTENTION : NE PAS OUVRIR UNE ATMOSPHÈRE EXPLOSIVE PRESENT.POUR INSTALLATIONS DE ZONE, UN SORTIE EST INSTALLÉ DANS LES 50 mm DE L'ENCEINTE. POUR INSTALLATIONS DE DIVISION ALE SORTIE EST INSTALLÉ DANS LES 18 POUCES DE L'ENCEINTE
EXPLOSIONPROOF CL. I, DIV. 1, GR BCD T6...T3. Ex db IIB+H2 T6...T3 Ga/Gb Ta = -40°C to +71°C ; IP 65
7957 RELEASE FOR PRODUCTION
(ACP) LABEL, LP, XP CANADA - DIGITAL
R FM APPROVED
P/N 551706-1 REV A
LEVEL
1:1
!
C 1
1
2
2
A A
B B
REV ECO # DESCRIPTION
TITLE
SIZE DWG NO. REV
PRODUCT LINESCALE:
BY DATE
SHEET OF
UNLESS OTHERWISE SPECIFIEDTOLERANCES
0 PLACESMM
1 PLACEMM
ANGLES� � �� 0.5 � 0.1
- THREAD DEPTHS ARE TO MIN. FULL THDS- DRILL DEPTHS ARE TO FULL DIA.- REMOVE BURRS AND SHARP EDGES- DO NOT SCALE PRINT- MACHINED SURFACE FINISH 3.2uM [125 uIn]
PROPRIETARY DATATHE INFORMATION AND DESIGN(S) DISCLOSEDHEREIN ARE THE PROPERTY OF MTS SYSTEMSCORPORATION AND MAY NOT BE USED,REPRODUCED OR DISCLOSED IN ANY FORMEXCEPT AS GRANTED IN WRITING BY MTSSYSTEMS CORPORATION. THIS RESTRICTIONEXCLUDES INFORMATION THAT IS IN THE PUBLIC DOMAIN OR WAS LEGITIMATELY IN THEPRIOR POSSESSION OF THE RECIPIENT.
mMTS SYSTEMS CORPORATIONSENSORS DIVISION3001 SHELDON DRIVE, CARY, NC 27513
METRIC
FIRST ANGLE A 551706-x A
1 1
DRAWN BY: MS
***NO REVISIONS SHALL BE MADE WITHOUT THE NOTIFICATION TO APPROVAL AGENCY(S).***A MS 7/28/16
MTS Systems CorporationSensors Division3001 Sheldon Drive, Cary, N.C. 27513
Level Plus Transmitter�
FM16CA0130X
INSTALL PER # 651552-2MAX. PRESSURE 1000 PSI (RIGID SENSOR)MAX. PRESSURE 435 PSI (FLEX SENSOR)INPUT: 28V (120mA)max OUTPUT: RS485
WARNING: DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE IS PRESENT. FOR ZONE INSTALLATIONS, A SEAL SHALL BE INSTALLED WITHIN 50mm OF THE ENCLOSURE. FOR DIVISION INSTALLATIONS A SEAL SHALL BE INSTALLED WITHIN 18 INCHESOF THE ENCLOSURE ATTENTION : NE PAS OUVRIR UNE ATMOSPHÈRE EXPLOSIVE PRESENT.POUR INSTALLATIONS DE ZONE, UN SORTIE EST INSTALLÉ DANS LES 50 mm DE L'ENCEINTE. POUR INSTALLATIONS DE DIVISION ALE SORTIE EST INSTALLÉ DANS LES 18 POUCES DE L'ENCEINTE
EXPLOSIONPROOF CL. I, DIV. 1, GR. BCD T6...T3 Ex db IIB+H2 T6...T3 Ga/Gb Ta = -40°C to +71°C ; IP 65
7957 RELEASE FOR PRODUCTION
(ACP) LABEL, LP, XP CANADA - DIGITAL
R FM APPROVED
P/N 551706-2 REV A
LEVEL
1:1
!
C 1
1
2
2
A A
B B
REV ECO # DESCRIPTION
TITLE
SIZE DWG NO. REV
PRODUCT LINESCALE:
BY DATE
SHEET OF
UNLESS OTHERWISE SPECIFIEDTOLERANCES
0 PLACESMM
1 PLACEMM
ANGLES� � �� 0.5 � 0.1
- THREAD DEPTHS ARE TO MIN. FULL THDS- DRILL DEPTHS ARE TO FULL DIA.- REMOVE BURRS AND SHARP EDGES- DO NOT SCALE PRINT- MACHINED SURFACE FINISH 3.2uM [125 uIn]
PROPRIETARY DATATHE INFORMATION AND DESIGN(S) DISCLOSEDHEREIN ARE THE PROPERTY OF MTS SYSTEMSCORPORATION AND MAY NOT BE USED,REPRODUCED OR DISCLOSED IN ANY FORMEXCEPT AS GRANTED IN WRITING BY MTSSYSTEMS CORPORATION. THIS RESTRICTIONEXCLUDES INFORMATION THAT IS IN THE PUBLIC DOMAIN OR WAS LEGITIMATELY IN THEPRIOR POSSESSION OF THE RECIPIENT.
mMTS SYSTEMS CORPORATIONSENSORS DIVISION3001 SHELDON DRIVE, CARY, NC 27513
METRIC
FIRST ANGLE A 551708-x A
1 1
DRAWN BY: MS
***NO REVISIONS SHALL BE MADE WITHOUT THE NOTIFICATION TO APPROVAL AGENCY(S).***A MS 7/28/16
Level Plus TransmitterFM16CA0130X
�
MTS Systems CorporationSensors Division3001 Sheldon Drive, Cary, N.C. 27513
WARNING: DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE IS PRESENT. FOR ZONE INSTALLATIONS, A SEAL SHALL BE INSTALLED WITHIN 50mm OF THE ENCLOSURE. FOR DIVISION INSTALLATIONS A SEAL SHALL BE INSTALLED WITHIN 18 INCHESOF THE ENCLOSURE. ATTENTION : NE PAS OUVRIR UNE ATMOSPHÈRE EXPLOSIVE PRESENT POUR INSTALLATIONS DE ZONE, UN SORTIE EST INSTALLÉ DANS LES 50 mm DE L'ENCEINTE. POUR INSTALLATIONS DE DIVISION ALE SORTIE EST INSTALLÉ DANS LES 18 POUCES DE L'ENCEINTE
EXPLOSIONPROOF CL. I, DIV. 1, GR.Ex db IIB+H2 T6...T3 Ga/Gb Ta = -40°C to +71°C ; IP 65
INSTALL PER # 651553-2MAX. PRESSURE 1000 PSI (RIGID SENSOR)MAX. PRESSURE 435 PSI (FLEX SENSOR)INPUT: 28V (120mA)max OUTPUT: 4-20mA
7957 RELEASE FOR PRODUCTION
(ACP) LABEL, LP, XP CANADA - ANALOG
BCD T6...T3
FM APPROVED
P/N 551708-1 Rev A
LEVEL
1:1
R
!
C 1
1
2
2
A A
B B
REV ECO # DESCRIPTION
TITLE
SIZE DWG NO. REV
PRODUCT LINESCALE:
BY DATE
SHEET OF
UNLESS OTHERWISE SPECIFIEDTOLERANCES
0 PLACESMM
1 PLACEMM
ANGLES� � �� 0.5 � 0.1
- THREAD DEPTHS ARE TO MIN. FULL THDS- DRILL DEPTHS ARE TO FULL DIA.- REMOVE BURRS AND SHARP EDGES- DO NOT SCALE PRINT- MACHINED SURFACE FINISH 3.2uM [125 uIn]
PROPRIETARY DATATHE INFORMATION AND DESIGN(S) DISCLOSEDHEREIN ARE THE PROPERTY OF MTS SYSTEMSCORPORATION AND MAY NOT BE USED,REPRODUCED OR DISCLOSED IN ANY FORMEXCEPT AS GRANTED IN WRITING BY MTSSYSTEMS CORPORATION. THIS RESTRICTIONEXCLUDES INFORMATION THAT IS IN THE PUBLIC DOMAIN OR WAS LEGITIMATELY IN THEPRIOR POSSESSION OF THE RECIPIENT.
mMTS SYSTEMS CORPORATIONSENSORS DIVISION3001 SHELDON DRIVE, CARY, NC 27513
METRIC
FIRST ANGLE A 551708-x A
1 1
DRAWN BY: MS
***NO REVISIONS SHALL BE MADE WITHOUT THE NOTIFICATION TO APPROVAL AGENCY(S).***A MS 7/28/16
Level Plus TransmitterFM16CA0130X
�
MTS Systems CorporationSensors Division3001 Sheldon Drive, Cary, N.C. 27513
WARNING: DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE IS PRESENT. FOR ZONE INSTALLATIONS, A SEAL SHALL BE INSTALLED WITHIN 50mm OF THE ENCLOSURE. FOR DIVISION INSTALLATIONS A SEAL SHALL BE INSTALLED WITHIN 18 INCHESOF THE ENCLOSURE. ATTENTION : NE PAS OUVRIR UNE ATMOSPHÈRE EXPLOSIVE PRESENT POUR INSTALLATIONS DE ZONE, UN SORTIE EST INSTALLÉ DANS LES 50 mm DE L'ENCEINTE. POUR INSTALLATIONS DE DIVISION ALE SORTIE EST INSTALLÉ DANS LES 18 POUCES DE L'ENCEINTE
EXPLOSIONPROOF CL. I, DIV. 1, GR. BCD T6...T3Ex db IIB+H2 T6...T3 Ga/Gb Ta = -40°C to +71°C ; IP 65
INSTALL PER # 651553-2MAX. PRESSURE 1000 PSI (RIGID SENSOR)MAX. PRESSURE 435 PSI (FLEX SENSOR)INPUT: 28V (120mA)max OUTPUT: 4-20mA
7957 RELEASE FOR PRODUCTION
(ACP) LABEL, LP, XP CANADA - ANALOG
FM APPROVED
P/N 551708-2 Rev A
LEVEL
1:1
R
!
C
13.4.2.2 Etiquetas
Level Plus® CON COMPARTIMIENTOSManual de funcionamiento
I 39 I
13.4.2.3 Plano de instalación
Fig. 44: Resistente a explosiones, plano de instalación FMC, Modbus y DDA, página 1
11
22
33
44
55
66
77
88
AA
BB
CC
DD
REV
ECO
#D
ESCR
IPTION
TITLE
SIZED
WG
NO
.R
EV
PRO
DU
CT LIN
ESC
ALE:
BYD
ATE
SHEET
OF
UN
LESS OTH
ERW
ISE SPECIFIED
TOLER
ANC
ES0 PLAC
ESM
M1 PLAC
EM
MAN
GLES
0.5
0.1
- THR
EAD
DEPTH
S ARE TO
MIN
. FULL TH
DS
- DR
ILL DEPTH
S ARE TO
FULL D
IA.
- REM
OV
E BU
RR
S AND
SHAR
P E
DG
ES- D
O N
OT SC
ALE PRIN
T- M
ACH
INED
SUR
FACE
FINISH
3.2uM [125 uIn]
PRO
PRIETAR
Y DATA
THE IN
FOR
MATIO
N AN
D D
ESIG
N(S) D
ISCLO
SEDH
ERE
IN AR
E THE PR
OPER
TY OF M
TS SYSTEMS
CO
RPO
RATIO
N AN
D M
AY NO
T BE USED
,R
EPRO
DU
CED
OR
DISC
LOSED
IN A
NY FO
RM
EXCEPT AS G
RAN
TED IN
WR
ITING
BY MTS
SYSTEMS C
OR
POR
ATIO
N. TH
IS RESTR
ICTIO
NEXC
LUD
ES INFO
RM
ATION
THA
T IS IN TH
E PU
BLIC D
OM
AIN O
R W
AS LEGITIM
ATELY IN TH
EPR
IOR
POSSES
SION
OF TH
E REC
IPIENT.
mM
TS SYSTEMS C
OR
POR
ATION
SENSO
RS D
IVISION
3001 SHELD
ON
DR
IVE, CAR
Y, NC
27513
METRIC
FIRST
ANG
LED
651553-2B
LEVEL1
3 D
RAW
N BY:
MS
***NO
REVISIO
NS SH
ALL BE MAD
E WITH
OU
T THE N
OTIFIC
ATION
TO APPR
OVAL AG
ENC
Y(S).***B
MS
10/22/15RELEASE TO PRODUCTION
8482UPDATED W
IRING DWG TO ANALOG
MS
5/17/18A
7957
LOOP 2+
LOOP 2-
EARTH GROUND
LOOP 1+
LOOP 1-
EARTH GROUND
SEE NOTE 8EPL Ga
EPL Gb
NO
N H
AZARD
OU
S LOC
ATION
HAZAR
DO
US LO
CATIO
N
EARTH
GR
OU
ND
LUG
NO
TE 3
AGEN
CY C
ON
TRO
LLED D
RAW
ING
(Canada). N
O C
HAN
GES W
ITHO
UT PR
IOR
AGEN
CY APPR
OVAL
FM
APPROVED
C
(ACP) INSTALLATION DWG LP ANALOG
EXPLOSION PROOF CANADA
SING
LE OR
DU
AL CAVITY
FM Canada - FM
16CA0130X
EXPLOSION PROOFCL. I, DIV. 1, GR. BCD T6...T3Ex db IIB+H2 T6...T3 Ga/GbTa = -40°C to +71°C ; IP65
CO
ND
UIT SEAL
CO
ND
UIT
CO
ND
UIT SEAL
SEE NO
TE 1
NO
TES:1.ALL N
ATION
AL AND
LOC
AL CO
DES AN
D R
EGU
LATION
S MU
ST BE ADH
ERED
TO W
HEN
INSTALLIN
G TH
E LEVEL SENSO
R IN
HAZAR
DO
US EN
VIRO
NM
ENTS.
FOR
ZON
E INSTALLATIO
NS, A SEAL SH
ALL BE INSTALLED
WITH
IN 50m
m O
F THE
ENC
LOSU
RE. FO
R D
IVISION
INSTALLATIO
NS, A SEAL SH
ALL BE INSTALLED
WITH
IN 18 IN
CH
ES OF TH
E ENC
LOSU
RE.
2.DU
AL-CAVITY EN
CLO
SUR
ES: C
USTO
MER
CO
NN
ECTIO
NS W
ILL BE MAD
E AT TERM
INAL BLO
CK O
N PO
WER
SIDE
OF H
OU
SING
(NO
T TO TER
MIN
AL BLOC
K ON
INTER
CO
NN
ECT BO
ARD
). SEE FIGU
RE 2 O
N PAG
E 23. C
AUTIO
N: FLEXIBLE G
AUG
ES HAVE A M
INIM
UM
BEND
RAD
IUS O
F 381mm
(15")4.W
ARN
ING
: TO PR
EVENT IG
NITIO
N O
F FLAMM
ABLE OR
CO
MBU
STIBLE ATMO
SPHER
ES, D
ISCO
NN
ECT PO
WER
BEFOR
E SERVIC
ING
5.W
ARN
ING
: THE EQ
UIPM
ENT C
ON
TAINS N
ON
-METALLIC
ENC
LOSU
RE AN
D PR
OC
ESS PARTS, TO
PREVEN
T TH
E RISK O
F ELECTR
OSTATIC
SPARK IN
G. TH
E NO
N-M
ETALLIC SU
RFAC
E AND
PRO
CESS PAR
TS SHO
ULD
ON
LY BE C
LEANED
WITH
A DAM
P CLO
TH. PAINTED SURFACE OF THE EQUIPM
ENT MAY STORE ELECTROSTATIC CHARGE
AND BECOME A SOURCE OF IGNITION IN APPLICATIONS W
ITH A LOW RELATIVE HUM
IDITY <~30% RELATIVE
HUMIDITY W
HERE THE PAINTED SURFACE IS RELATIVELY FREE OF SURFACE CONTAMINATION
SUCH AS DIRT, DUST OR OIL. CLEANING OF THE PAINTED SURFACE SHOULD ONLY BE DONE W
ITH A DAMP CLOTH.
6. CABLES SH
ALL BE RATED
> 5C ABO
VE MAXIM
UM
AMBIEN
T TEMPER
ATUR
E. 7. TO
MAIN
TAIN TH
E ING
RESS PR
OTEC
TION
RATIN
G O
F IP65, TEFLON
TAPE (3 WR
APS) OR
PIPE DO
PE SHALL
BE USED
. REFER
TO IN
STALLATION
INSTR
UC
TION
S.8. TH
E EQU
IPMEN
T CAN
BE INSTALLED
IN TH
E BOU
ND
ARY W
ALL BETWEEN
A ZON
E 0 AREA AN
D TH
E LESS H
AZARD
OU
S AREA, ZO
NE 1. IN
THIS C
ON
FIGU
RATIO
N, TH
E PRO
CESS C
ON
NEC
TION
IS INSTALLED
IN
A ZON
E 0 AREA, W
HILE TH
E TRAN
SMITTER
HO
USIN
G IS IN
STALLED IN
A ZON
E 1 AREA.
9. THE APPLIC
ABLE TEMPER
ATUR
E CLASS O
F THE EQ
UIPM
ENT, AM
BIENT TEM
PERATU
RE R
ANG
E, AN
D M
AXIMU
M PR
OC
ESS TEMPER
ATUR
E OF TH
E EQU
IPMEN
T IS AS FOLLO
WS;
T3 WITH
PRO
CESS TEM
PERATU
RE R
ANG
E OF -40°C
to +150°C T4 W
ITH PR
OC
ESS TEMPER
ATUR
E RAN
GE O
F -40°C to +135°C
T5 WITH
PRO
CES S TEM
PERATU
RE R
ANG
E OF -40°C
to +100°C T6 W
ITH PR
OC
ESS TEMPER
ATUR
E RAN
GE O
F -40°C to +85°C
AMBIEN
T TEMPER
ATUR
E RAN
GE -40°C Ta+71°C
10. WH
EN M
OU
NTIN
G O
N A M
AGN
ETIC LEVEL G
AUG
E MAKE SU
RE TH
E ELECTR
ON
IC H
EAD AN
D PR
ESSUR
E BAR
RIER
HAVE A M
INIM
UM
SPACIN
G O
F 5 INC
HES. SEE IN
STALLATION
MAN
UAL FO
R D
ETAIL11. FLAM
EPATHS AR
E NO
T FOR
REPAIR
5"[127mm
] Minim
um
Level Plus® CON COMPARTIMIENTOSManual de funcionamiento
I 40 I
Fig. 45: Resistente a explosiones, plano de instalación FMC, Modbus y DDA, página 2
DETAIL D
SCALE 3
DETAIL E
SCALE 1.60
DETAIL F
SCALE 1.2
D
E
F
11
22
33
44
55
66
77
88
AA
BB
CC
DD
REV
ECO
#D
ESCR
IPTION
TITLE
SIZED
WG
NO
.R
EV
PRO
DU
CT LIN
ESC
ALE:
BYD
ATE
SHEET
OF
UN
LESS OTH
ERW
ISE SPECIFIED
TOLER
ANC
ES0 PLAC
ESM
M1 PLAC
EM
MAN
GLES
0.5
0.1
- THR
EAD
DEPTH
S ARE TO
MIN
. FULL TH
DS
- DR
ILL DEPTH
S ARE TO
FULL D
IA.
- REM
OV
E BU
RR
S AND
SHAR
P E
DG
ES- D
O N
OT SC
ALE PRIN
T- M
ACH
INED
SUR
FACE
FINISH
3.2uM [125 uIn]
PRO
PRIETAR
Y DATA
THE IN
FOR
MATIO
N AN
D D
ESIG
N(S) D
ISCLO
SEDH
ERE
IN AR
E THE PR
OPER
TY OF M
TS SYSTEMS
CO
RPO
RATIO
N AN
D M
AY NO
T BE USED
,R
EPRO
DU
CED
OR
DISC
LOSED
IN A
NY FO
RM
EXCEPT AS G
RAN
TED IN
WR
ITING
BY MTS
SYSTEMS C
OR
POR
ATIO
N. TH
IS RESTR
ICTIO
NEXC
LUD
ES INFO
RM
ATION
THA
T IS IN TH
E PU
BLIC D
OM
AIN O
R W
AS LEGITIM
ATELY IN TH
EPR
IOR
POSSES
SION
OF TH
E REC
IPIENT.
mM
TS SYSTEMS C
OR
POR
ATION
SENSO
RS D
IVISION
3001 SHELD
ON
DR
IVE, CAR
Y, NC
27513
METRIC
FIRST
ANG
LED
651553-2B
LEVEL2
3 D
RAW
N BY:
MS
***NO
REVISIO
NS SH
ALL BE MAD
E WITH
OU
T THE N
OTIFIC
ATION
TO APPR
OVAL AG
ENC
Y(S).***B
MS
10/22/15RELEASE TO PRODUCTION
8482UPDATED W
IRING DWG TO ANALOG
MS
5/17/18A
7957
LOOP 2-
LOOP 2+
EARTH
LOOP 1-
LOOP 1+
NO
TES: 1. TH
E CU
STOM
ER SH
OU
LD C
ON
NEC
T THE O
UTSID
E GR
OU
ND
LUG
TO TH
E SAFETY EARTH
ING
GR
OU
ND
SYSTEM W
ARN
ING
: W
HEN
INSTALLIN
G TH
E LEVEL SENSO
R IN
HAZAR
DO
US EN
VIRO
NM
ENTS.
FOR
ZON
E INSTALLATIO
NS, A SEAL SH
ALL BE INSTALLED
WITH
IN 50m
m O
F THE
ENC
LOSU
RE. FO
R D
IVISION
INSTALLATIO
NS, A SEAL SH
ALL BE INSTALLED
WITH
IN 18 IN
CH
ES OF TH
E ENC
LOSU
RE.
FIGU
RE 2
DU
AL CAVITY H
OU
SING
LOOP 1+ LOOP 1- EARTH LOOP 2+ LOOP 2-
FIGU
RE 1
SING
LE CAVITY H
OU
SING
LOOP 1+ LOOP 1- EARTH LOOP 2+ LOOP 2-
(ACP) INSTALLATION DWG LP ANALOG
EXPLOSION PROOF CANADA
Level Plus® CON COMPARTIMIENTOSManual de funcionamiento
I 41 I
Fig. 46: Resistente a explosiones, plano de instalación FMC, Modbus y DDA, página 3
11
22
33
44
55
66
77
88
AA
BB
CC
DD
REV
ECO
#D
ESCR
IPTION
TITLE
SIZED
WG
NO
.R
EV
PRO
DU
CT LIN
ESC
ALE:
BYD
ATE
SHEET
OF
UN
LESS OTH
ERW
ISE SPECIFIED
TOLER
ANC
ES0 PLAC
ESM
M1 PLAC
EM
MAN
GLES
0.5
0.1
- THR
EAD
DEPTH
S ARE TO
MIN
. FULL TH
DS
- DR
ILL DEPTH
S ARE TO
FULL D
IA.
- REM
OV
E BU
RR
S AND
SHAR
P E
DG
ES- D
O N
OT SC
ALE PRIN
T- M
ACH
INED
SUR
FACE
FINISH
3.2uM [125 uIn]
PRO
PRIETAR
Y DATA
THE IN
FOR
MATIO
N AN
D D
ESIG
N(S) D
ISCLO
SEDH
ERE
IN AR
E THE PR
OPER
TY OF M
TS SYSTEMS
CO
RPO
RATIO
N AN
D M
AY NO
T BE USED
,R
EPRO
DU
CED
OR
DISC
LOSED
IN A
NY FO
RM
EXCEPT AS G
RAN
TED IN
WR
ITING
BY MTS
SYSTEMS C
OR
POR
ATIO
N. TH
IS RESTR
ICTIO
NEXC
LUD
ES INFO
RM
ATION
THA
T IS IN TH
E PU
BLIC D
OM
AIN O
R W
AS LEGITIM
ATELY IN TH
EPR
IOR
POSSES
SION
OF TH
E REC
IPIENT.
mM
TS SYSTEMS C
OR
POR
ATION
SENSO
RS D
IVISION
3001 SHELD
ON
DR
IVE, CAR
Y, NC
27513
METRIC
FIRST
ANG
LED
651553-2B
LEVEL3
3 D
RAW
N BY:
MS
***NO
REVISIO
NS SH
ALL BE MAD
E WITH
OU
T THE N
OTIFIC
ATION
TO APPR
OVAL AG
ENC
Y(S).***B
MS
10/22/15RELEASE TO PRODUCTION
8482UPDATED W
IRING DWG TO ANALOG
MS
5/17/18A
7957
NO
TES:1. La réglem
entation doit être respectée suivant les codes locaux et nationaux LO
RS D
'INSTALLATIO
N D
U C
APTEUR
DE N
IVEAU D
ANS D
ES ENVIR
ON
NEM
ENTS D
ANG
EREU
X. PO
UR
INSTALLATIO
NS D
E ZON
E, UN
SOR
TIE EST INSTALLÉ D
ANS LES 50 m
m D
E L'ENC
EINTE.
POU
R IN
STALLATION
S DE D
IVISION
ALE SOR
TIE EST INSTALLÉ D
ANS LES 18 PO
UC
ES DE L'EN
CEIN
TE2. EN
CEIN
TES à cavité double : Les raccordements clients, seront effectués au bornier d'alim
entation sur le côté du LOG
EMEN
T boîtier (pas au bornier carte d'interconnexion) 3. ATTEN
TION
: LES INSTR
UM
ENTS FLEXIBLES AVEC
UN
RAD
IOD
E MIN
IMU
M D
E 381mm
(15 ")4. ATTEN
TION
: Pour éviter l'inflamm
ation d'atmosphères inflam
mables ou com
bustibles , D
ÉBRAN
CH
EZ L'ALIMEN
TATION
AVANT D
'INTER
VENIR
5. AVERTISSEM
ENT: L'ÉQ
UIPEM
ENT C
ON
TENU
E DES PIÈC
ES ET PRO
CÉD
ÉS NO
N-M
ETALLIQU
ES POU
R PR
ÉVENIR
LE RISQ
UE D
'ÉCLAIR
AGE ÉLEC
TRO
STATIQU
E. LA SUR
FACE ET LES PIÈC
ES DE PR
OC
ÉDU
RE N
ON
MÉTALLIQ
UES D
OIVEN
T SEULEM
ENT
EFFECTEZ U
N PAN
NEAU
DE PLAISIR
. LA SUR
FACE PEIN
TÉE DE L'ÉQ
UIPEM
ENT PEU
T CO
NSER
VER LE C
HAR
GE ÉLEC
TRO
STATIQU
E ET D
EVENIR
UN
E SOU
RC
E D'A LLU
MAG
E DAN
S DES APPLIC
ATION
S AVEC U
NE H
UM
IDITÉ BASSE R
ELATIVE <~ 30% R
ELATIVE H
UM
IDITE O
Ù LA SU
RFAC
E PEINTU
RE EST R
ELATIVEMEN
T LIBRE D
E CO
NTAM
INATIO
N D
E SUR
FACE
TELS QU
E LA VIAND
E, LA POU
SSIÈRE O
U L'H
UILE. LE N
ETTOYAG
E DE LA SU
RFAC
E PEINTU
RE D
OIT ÊTR
E FAIT AVEC
UN
PANN
EAU D
E PLAISIR.
6. CABLES doit être évalué> 5C
DESSU
S MAXIM
UM
TEMPER
ATUR
E AMBIAN
TE.7. PO
UR
MAIN
TENIR
LA NO
TATION
DE PR
OTEC
TION
DE IN
GR
ESS IP65, du ruban téflon (3 BAND
ES) ou PIPE DO
PE DEVR
A ÊTRE U
TILISÉ. CO
NSU
LTER LES IN
STRU
CTIO
NS D
'INSTALLATIO
N.
8. L'ÉQU
IPEMEN
T PEUT ÊTR
E INSTALLÉ D
ANS LE M
UR
DE LIM
ITE ENTR
E UN
E ZON
E 0 ET LA ZO
NE M
OIN
S DAN
GER
EUSE, ZO
NE 1. D
ANS C
ETTE CO
NFIG
UR
ATION
, LA CO
NN
EXION
DU
PRO
CESSU
S EST INSTALLEE
DAN
S UN
E ZON
E 0, LOR
SQU
E LE BOITIER
DE L'EM
ETTEUR
EST INSTALLE D
ANS U
NE ZO
NE D
E LA ZON
E 1. 9. LA TEM
PERATU
RE C
LASSE APPLICABLE D
E L'ÉQU
IPEMEN
T , TEMPER
ATUR
E AMBIAN
TE RAN
GE,
ET MAXIM
UM
PRO
CESSU
S TEMPER
ATUR
E DE L'APPAR
EIL EST CE Q
UI SU
IT ; T3 W
ITH PR
OC
ESS TEMPER
ATUR
E RAN
GE O
F -40°C to +150°C
T4 WITH
PRO
CESS TEM
PERATU
RE R
ANG
E OF -40°C
to +135°C T5 W
ITH PR
OC
ESS TEMPER
ATUR
E RAN
GE O
F -40°C to +100°C
T6 WITH
PRO
CESS TEM
PERATU
RE R
ANG
E OF -40°C
to +85°C AM
BIE NT TEM
PERATU
RE R
ANG
E -40°CTa+71°C 10.LO
RS D
U M
ON
TAGE SU
R U
NE JAU
GE D
E NIVEAU
MAG
NÉTIQ
UE, ASSU
REZ-VO
US Q
UE LA TÊTE ÉLEC
TRO
NIQ
UE ET LA PR
ESSION
BARR
IÈRE A U
N ESPAC
EMEN
T MIN
IMU
M D
E 5 POU
CES. VO
IR LE M
ANU
EL D'IN
STALLATION
POU
R D
ETAIL11.C
HEM
IN D
E FLAMM
E NE SO
NT PAS À R
ÉPARER
(ACP) INSTALLATION DWG LP ANALOG
EXPLOSION PROOF CANADA
Level Plus® CON COMPARTIMIENTOSManual de funcionamiento
I 42 I
11
22
33
44
55
66
77
88
AA
BB
CC
DD
REV
EC
O #
DESC
RIP
TION
TITLE
SIZED
WG
NO
.R
EV
PRO
DU
CT LIN
ESC
ALE:
BYD
ATE
SHEET
OF
UN
LES
S OTH
ER
WISE
SPEC
IFIED
TOLER
ANC
ES0 P
LACE
SM
M1 PLA
CE
MM
AN
GLE
S
0.5
0.1
- THR
EA
D D
EP
THS
AR
E TO
MIN
. FULL TH
DS
- DR
ILL DE
PTH
S A
RE
TO FU
LL DIA
.- R
EM
OV
E B
UR
RS
AN
D S
HA
RP
ED
GE
S- D
O N
OT S
CA
LE P
RIN
T- M
AC
HIN
ED
SU
RFA
CE
FINIS
H 3.2uM
[125 uIn]
PRO
PRIETA
RY D
ATA
THE
INFO
RM
ATIO
N A
ND
DE
SIG
N(S
) DIS
CLO
SE
DH
ER
EIN
AR
E TH
E P
RO
PE
RTY
OF M
TS S
YS
TEM
SC
OR
PO
RA
TION
AN
D M
AY
NO
T BE
US
ED
,R
EP
RO
DU
CE
D O
R D
ISC
LOS
ED
IN A
NY
FOR
ME
XC
EP
T AS
GR
AN
TED
IN W
RITIN
G B
Y M
TSS
YS
TEM
S C
OR
PO
RA
TION
. THIS
RE
STR
ICTIO
NE
XC
LUD
ES
INFO
RM
ATIO
N TH
AT IS
IN TH
E
PU
BLIC
DO
MA
IN O
R W
AS
LEG
ITIMA
TELY
IN TH
EP
RIO
R P
OS
SE
SS
ION
OF TH
E R
EC
IPIE
NT.
mM
TS SYS
TEMS
CO
RP
OR
ATIO
NS
ENSO
RS D
IVISIO
N3001 SH
ELDO
N D
RIVE
, CA
RY, N
C 27513
METRIC
FIRST
ANG
LED
651552-2A
1
3 D
RAW
N BY:
MS
***NO
RE
VISION
S SHALL BE
MA
DE
WITH
OU
T THE
NO
TIFICA
TION
TO A
PPRO
VAL AG
EN
CY(S).***
AM
S10/24/14
RELEASE TO PRO
DU
CTION
EARTH G
ROU
ND
Rx /Tx-
Rx /Tx+
EARTH G
ROU
ND
COM
MO
N-
24 VDC
EPL Ga
EPL Gb
SEE NO
TE 8
NO
N H
AZARDO
US LO
CATION
HAZARD
OU
S LOCATIO
N
AGEN
CY C
ON
TRO
LLED D
RAW
ING
(CAN
ADA). N
O C
HAN
GES W
ITHO
UT PR
IOR
AGEN
CY APPR
OVAL
EARTH TERM
INAL
(ACP) INSTALLATIO
N D
WG
LP DIG
ITAL EXPLO
SION
PROO
F CANAD
A
7957
LEVEL
FM
APPROVED
C
N/A
EXPLOSIO
N PRO
OF
CL. I, DIV. 1, G
R. BCD T6...T3
Ex db IIB+H
2 T6...T3 Ga/G
bTa =
-40°C to +71°C ; IP65
FM CAN
ADA- FM
16CA0130XN
OTES:
1.ALL NATIO
NAL AN
D LO
CAL C
OD
ES AN
D R
EGU
LATION
S MU
ST BE AD
HER
ED TO
WH
EN IN
STALLING
THE LEVEL SEN
SOR
IN H
AZARD
OU
S ENVIR
ON
ME
NTS.
FOR
ZON
E INSTALLATIO
NS, A SEAL SH
ALL BE INSTALLED
WITH
IN 50m
m O
F THE
ENC
LOSU
RE. FO
R D
IVISION
INSTALLATIO
NS, A SEAL SH
ALL BE INSTALLED
WITH
IN 18 IN
CH
ES O
F THE EN
CLO
SUR
E.
2.DU
AL-CAVITY EN
CLO
SUR
ES: C
USTO
ME
R C
ON
NE
CTIO
NS W
ILL BE MAD
E AT TERM
INAL BLO
CK O
N PO
WER
SIDE
OF H
OU
SING
(NO
T TO TER
MIN
AL BLOC
K ON
INTER
CO
NN
ECT BO
ARD
). SEE FIGU
RE 2 O
N PAG
E 2
3. CAU
TION
: FLEXIBLE GAU
GES H
AVE A MIN
IMU
M BEN
D R
ADIU
S OF 381m
m(15")
4.WAR
NIN
G: TO
PR
EVEN
T IGN
ITION
OF FLAM
MA
BLE OR
CO
MBU
STIBLE ATM
OSPH
ERES,
DISC
ON
NE
CT PO
WER
BEFOR
E SER
VICIN
G
5.WAR
NIN
G: TH
E EQU
IPMEN
T CO
NTAIN
S NO
N-M
ETALLIC EN
CLO
SUR
E AND
PRO
CESS PAR
TS, TO PR
EVENT
THE R
ISK O
F ELECTR
OSTATIC
SPARKIN
G. TH
E NO
N-M
ETALLIC
SUR
FACE AN
D PR
OC
ESS PARTS SH
OU
LD O
NLY
BE C
LEAN
ED W
ITH A D
AMP
CLO
TH. PAIN
TED SU
RFACE OF TH
E EQU
IPMEN
T MAY STO
RE ELECTROSTATIC CH
ARGE
AND
BECOM
E A SOU
RCE OF IG
NITIO
N IN
APPLICATION
S WITH
A LOW
RELATIVE HU
MID
ITY <~
30% RELATIVE
HU
MID
ITY WH
ERE THE PAIN
TED SU
RFACE IS RELATIVELY FREE OF SU
RFACE CO
NTAM
INATIO
N SU
CH AS D
IRT, DU
ST OR
OIL. CLEAN
ING
OF TH
E PAINTED
SURFACE SH
OU
LD O
NLY BE D
ON
E W
ITH A D
AMP CLO
TH.
6. CAB
LES SH
ALL BE
RATED
> 5C ABO
VE MAXIM
UM
AMBIEN
T TEMPER
ATUR
E. 7. TO
MAIN
TAIN TH
E ING
RESS PR
OTEC
TION
RATIN
G O
F IP65, TEFLON
TAPE (3 WR
APS) O
R PIPE D
OPE SH
ALL B
E USE
D. R
EFER TO
INSTALLATIO
N IN
STRU
CTIO
NS.
8. THE EQ
UIPM
ENT C
AN BE IN
STALLED IN
THE BO
UN
DAR
Y WALL BETW
EEN A
ZON
E 0 AREA AN
D TH
E LE
SS HAZAR
DO
US AR
EA, ZON
E 1. IN TH
IS CO
NFIG
UR
ATION
, THE PR
OC
ESS CO
NN
ECTIO
N IS IN
STALLED
IN
A ZON
E 0 AR
EA, WH
ILE THE TR
ANSM
ITTER H
OU
SING
IS INSTALLED
IN A ZO
NE
1 AR
EA. 9. TH
E APPLICABLE TEM
PER
ATUR
E CLASS O
F THE EQ
UIPM
ENT, AM
BIENT TEM
PER
ATUR
E RAN
GE,
AN
D M
AXIMU
M PR
OC
ESS TEM
PER
ATUR
E OF TH
E EQU
IPMEN
T IS AS FOLLO
WS;
T3 WITH
PRO
CE
SS TEMPER
ATUR
E RAN
GE O
F -40°C to +150°C
T4 WITH
PRO
CE
SS TEMPER
ATUR
E RAN
GE O
F -40°C to +135°C
T5 WITH
PRO
CE
SS TEMPER
ATUR
E RAN
GE O
F -40°C to +100°C
T6 WITH
PRO
CE
SS TEMPER
ATUR
E RAN
GE O
F -40°C to +85°C
AM
BIE
NT TEM
PERATU
RE R
AN
GE -40°C Ta+71°C
10. WH
EN
MO
UN
TING
ON
A MAG
NE
TIC LE
VEL G
AUG
E M
AKE
SUR
E TH
E ELE
CTR
ON
IC H
EAD
AN
D P
RES
SUR
E
BA
RR
IER H
AVE A
MIN
IMU
M S
PAC
ING
OF 5 IN
CH
ES. SE
E INSTALLATIO
N M
ANU
AL FO
R D
ETA
IL11. FLAM
EP
ATHS
ARE
NO
T FOR
RE
PAIR
CON
DU
IT
CON
DU
IT SEAL
SEE NO
TE 1
CON
DU
IT SEAL
5" [127mm
] Minim
um
Fig. 47: Resistente a explosiones, plano de instalación FMC, HART®, página 1
Level Plus® CON COMPARTIMIENTOSManual de funcionamiento
I 43 I
DETAIL F
SCALE 1.60 : 1
DETAIL G
SCALE 3 : 1
DETAIL H
SCALE 1.2
F
G
H
11
22
33
44
55
66
77
88
AA
BB
CC
DD
REV
ECO
#D
ESCR
IPTION
TITLE
SIZED
WG
NO
.R
EV
PRO
DU
CT LIN
ESC
ALE:
BYD
ATE
SHEET
OF
UN
LESS OTH
ERW
ISE SPECIFIED
TOLER
ANC
ES0 PLAC
ESM
M1 PLAC
EM
MAN
GLES
0.5
0.1
- THR
EAD D
EPTHS AR
E TO M
IN. FU
LL THD
S- D
RILL D
EPTHS AR
E TO FU
LL DIA.
- REM
OVE BU
RR
S AND
SHAR
P EDG
ES- D
O N
OT SC
ALE PRIN
T- M
ACH
INED
SUR
FACE FIN
ISH 3.2uM
[125 uIn]
PRO
PRIETAR
Y DATA
THE IN
FOR
MATIO
N AN
D D
ESIGN
(S) DISC
LOSED
HER
EIN AR
E THE PR
OPER
TY OF M
TS SYSTEMS
CO
RPO
RA TIO
N AN
D M
AY NO
T BE USED
,R
EPRO
DU
CED
OR
DISC
LOSED
IN AN
Y FOR
MEXC
EPT AS GR
ANTED
IN W
RITIN
G BY M
TSSYSTEM
S CO
RPO
RATIO
N. TH
IS RESTR
ICTIO
NEXC
LUD
ES INFO
RM
ATION
THAT IS IN
THE
PUBLIC
DO
MAIN
OR
WAS LEG
ITIMATELY IN
THE
PRIO
R PO
SSESSION
OF TH
E REC
IPIENT.
mM
TS SYSTEMS C
OR
POR
ATION
SENSO
RS D
IVISION
3001 SHELD
ON
DR
IVE, CAR
Y, NC
27513
METRIC
FIRST
ANG
LED
651552-2A
2
3 D
RAW
N BY:
MS
***NO
REVISIO
NS SH
ALL BE MAD
E WITH
OU
T THE N
OTIFIC
ATION
TO APPR
OVAL AG
ENC
Y(S).***A
MS
10/24/14RELEASE TO
PROD
UCTIO
N
+24V GNDEARTHTX/RX+TX/RX-
GND
+24V
TX/RX-
TX/RX+
EARTH
FIGU
RE 1
SING
LE CAVITY
FIGU
RE 2
DU
AL CAVITY H
OU
SING
NO
TES: 1. TH
E CU
STOM
ER SH
OU
LD C
ON
NEC
T THE O
UTSID
E GR
OU
ND
LUG
TO TH
E SAFETY EARTH
ING
GR
OU
ND
SYSTEM W
ARN
ING
: FO
R ZO
NE IN
STALLATION
S, A SEAL SHALL BE IN
STALLED W
ITHIN
50mm
OF TH
E EN
CLO
SUR
E. FOR
DIVISIO
N IN
STALLATION
S, A SEAL SHALL BE IN
STALLED W
ITHIN
18 INC
HES O
F THE EN
CLO
SUR
E.
(ACP) INSTALLATIO
N D
WG
LP DIG
ITAL EXPLO
SION
PROO
F CANAD
A
+24V GND EARTH Tx/Rx+ Tx/Rx-
7957
Fig. 48: Resistente a explosiones, plano de instalación FMC, HART®, página 2
Level Plus® CON COMPARTIMIENTOSManual de funcionamiento
I 44 I
11
22
33
44
55
66
77
88
AA
BB
CC
DD
REV
EC
O #
DESC
RIP
TION
TITLE
SIZED
WG
NO
.R
EV
PRO
DU
CT LIN
ESC
ALE:
BYD
ATE
SHEET
OF
UN
LES
S OTH
ER
WISE
SPEC
IFIED
TOLER
ANC
ES0 P
LACE
SM
M1 PLA
CE
MM
AN
GLE
S
0.5
0.1
- THR
EA
D D
EP
THS
AR
E TO
MIN
. FULL TH
DS
- DR
ILL DE
PTH
S A
RE
TO FU
LL DIA
.- R
EM
OV
E B
UR
RS
AN
D S
HA
RP
ED
GE
S- D
O N
OT S
CA
LE P
RIN
T- M
AC
HIN
ED
SU
RFA
CE
FINIS
H 3.2uM
[125 uIn]
PRO
PRIETA
RY D
ATA
THE
INFO
RM
ATIO
N A
ND
DE
SIG
N(S
) DIS
CLO
SE
DH
ER
EIN
AR
E TH
E P
RO
PE
RTY
OF M
TS S
YS
TEM
SC
OR
PO
RA
TION
AN
D M
AY
NO
T BE
US
ED
,R
EP
RO
DU
CE
D O
R D
ISC
LOS
ED
IN A
NY
FOR
ME
XC
EP
T AS
GR
AN
TED
IN W
RITIN
G B
Y M
TSS
YS
TEM
S C
OR
PO
RA
TION
. THIS
RE
STR
ICTIO
NE
XC
LUD
ES
INFO
RM
ATIO
N TH
AT IS
IN TH
E
PU
BLIC
DO
MA
IN O
R W
AS
LEG
ITIMA
TELY
IN TH
EP
RIO
R P
OS
SE
SS
ION
OF TH
E R
EC
IPIE
NT.
mM
TS SYS
TEMS
CO
RP
OR
ATIO
NS
ENSO
RS D
IVISIO
N3001 SH
ELDO
N D
RIVE
, CA
RY, N
C 27513
METRIC
FIRST
ANG
LED
651552-2A
3
3 D
RAW
N BY:
***NO
RE
VISION
S SHALL BE
MA
DE
WITH
OU
T THE
NO
TIFICA
TION
TO A
PPRO
VAL AG
EN
CY(S).***
A
NO
TES:1. La réglem
entation doit être respectée suivant les codes locaux et nationaux LO
RS D
'INSTALLATIO
N D
U C
APTEUR
DE N
IVEAU D
ANS D
ES ENVIR
ON
NEM
ENTS D
ANG
EREU
X. PO
UR
INSTALLATIO
NS D
E ZON
E, UN
SOR
TIE EST INSTALLÉ D
ANS LES 50 m
m D
E L'ENC
EINTE.
POU
R IN
STALLATION
S DE D
IVISION
ALE SOR
TIE EST INSTALLÉ D
ANS LES 18 PO
UC
ES DE L'EN
CEIN
TE2. EN
CEIN
TES à cavité double : Les raccordements clients, seront effectués au bornier d'alim
entation sur le côté du LOG
EMEN
T boîtier (pas au bornier carte d'interconnexion) 3. ATTEN
TION
: LES INSTR
UM
ENTS FLEXIBLES AVEC
UN
RAD
IOD
E MIN
IMU
M D
E 381mm
(15 ")4. ATTEN
TION
: Pour éviter l'inflamm
ation d'atmosphères inflam
mables ou com
bustibles, D
ÉBRAN
CH
EZ L'ALIMEN
TATION
AVANT D
'INTER
VENIR
5. AVERTISSEM
ENT: L'ÉQ
UIPEM
ENT C
ON
TENU
E DES PIÈC
ES ET PRO
CÉD
ÉS NO
N-M
ETALLIQU
ES POU
R PR
ÉVENIR
LE RISQ
UE D
'ÉCLAIR
AGE ÉLEC
TRO
STATIQU
E. LA SUR
FACE ET LES PIÈC
ES DE PR
OC
ÉDU
RE N
ON
MÉTALLIQ
UES D
OIVEN
T SEULEM
ENT
EFFECTEZ U
N PAN
NEAU
DE PLAISIR
. LA SUR
FACE PEIN
TÉE DE L'ÉQ
UIPEM
ENT PEU
T CO
NSER
VER LE C
HAR
GE ÉLEC
TRO
STATIQU
E ET D
EVENIR
UN
E SOU
RC
E D'ALLU
MAG
E DAN
S DES APPLIC
ATION
S AVEC U
NE H
UM
IDITÉ BASSE R
ELATIVE <~ 30% R
ELATIVE H
UM
IDITE O
Ù LA SU
RFAC
E PEINTU
RE EST R
ELATIVEMEN
T LIBRE D
E CO
NTAM
INATIO
N D
E SUR
FACE
TELS QU
E LA VIAND
E, LA POU
SSIÈRE O
U L'H
UILE. LE N
ETTOYAG
E DE LA SU
RFAC
E PEINTU
RE D
OIT ÊTR
E FAIT AVEC
UN
PANN
EAU D
E PLAISIR.
6. CABLES doit être évalué> 5C
DESSU
S MAXIM
UM
TEMPER
ATUR
E AMBIAN
TE.7. PO
UR
MAIN
TENIR
LA NO
TATION
DE PR
OTEC
TION
DE IN
GR
ESS IP65, du ruban téflon (3 BAND
ES) ou PIPE DO
PE DEVR
A ÊTRE U
TILISÉ. CO
NSU
LTER LES IN
STRU
CTIO
NS D
'INSTALLATIO
N.
8. L'ÉQU
IPEMEN
T PEUT ÊTR
E INSTALLÉ D
ANS LE M
UR
DE LIM
ITE ENTR
E UN
E ZON
E 0 ET LA ZO
NE M
OIN
S DAN
GER
EUSE, ZO
NE 1. D
ANS C
ETTE CO
NFIG
UR
ATION
, LA CO
NN
EXION
DU
PRO
CESSU
S EST INSTALLEE
DAN
S UN
E ZON
E 0, LOR
SQU
E LE BOITIER
DE L'EM
ETTEUR
EST INSTALLE D
ANS U
NE ZO
NE D
E LA ZON
E 1 9. LA TEM
PERATU
RE C
LASSE APPLICABLE D
E L'ÉQU
IPEMEN
T , TEMPER
ATUR
E AMBIAN
TE RAN
GE,
ET MAXIM
UM
PRO
CESSU
S TEMPER
ATUR
E DE L'APPAR
EIL EST CE Q
UI SU
IT ; T3 W
ITH PR
OC
ESS TEMPER
ATUR
E RAN
GE O
F -40°C to +150°C
T4 WITH
PRO
CESS TEM
PERATU
RE R
ANG
E OF -40°C
to +135°C T5 W
ITH PR
OC
ESS TEMPER
ATUR
E RAN
GE O
F -40°C to +100°C
T6 WITH
PRO
CESS TEM
PERATU
RE R
ANG
E OF -40°C
to +85°C AM
BIENT TEM
PERATU
RE R
ANG
E -40°CTa+71°C10.LO
RS D
U M
ON
TAGE SU
R U
NE JAU
GE D
E NIVEAU
MAG
NÉTIQ
UE, ASSU
REZ-VO
US Q
UE LA TÊTE ÉLEC
TRO
NIQ
UE ET LA PR
ESSION
BARR
IÈRE A U
N ESPAC
EMEN
T MIN
IMU
M D
E 5 POU
CES. VO
IR LE M
ANU
EL D'IN
STALLATION
POU
R D
ETAIL11.C
HEM
IN D
E FLAM
ME N
E SO
NT PA
S À R
ÉPAR
ER
7957RELEASE FO
R PROD
UCTIO
N
(ACP) INSTALLATIO
N D
WG
LP DIG
ITAL EXPLO
SION
PRO
OF CAN
ADA
Fig. 49: Resistente a explosiones, plano de instalación FMC, HART®, página 3
Level Plus® CON COMPARTIMIENTOSManual de funcionamiento
I 45 I
13.5 ATEX y IECEx
13.5.1 Seguridad intrínseca
13.5.1.1 Condiciones específicas para un uso seguro
1. La carcasa del aparato contiene aluminio y se considera que esto constituye un riesgo potencial de ignición por impacto o fricción. Se debe tener cuidado durante la instalación y el uso para evitar impactos o fricción. (cuando se instala con aprobación de Ga)
2. La temperatura ambiente máxima permitida del transmisor de nivel digital/analógico Level Plus® es de 71 ºC. Para evitar los efectos producidos por la temperatura del proceso y otros efectos térmicos, se debe tener cuidado para garantizar que el ambiente circundante y el ambiente dentro de la carcasa del transmisor no supere los 71 °C.
3. Algunos modelos contienen piezas no metálicas en la carcasa. Para evitar el riesgo de chispas electrostáticas sobre la superficie no metálica, la superficie se debe limpiar solo con un paño húmedo.
13.5.1.2 Etiquetas
1
1
2
2
A A
B B
REV ECO # DESCRIPTION
TITLE
SIZE DWG NO. REV
PRODUCT LINESCALE:
BY DATE
SHEET OF
UNLESS OTHERWISE SPECIFIEDTOLERANCES
0 PLACESMM
1 PLACEMM
ANGLES
0.5 0.1
- THREAD DEPTHS ARE TO MIN. FULL THDS- DRILL DEPTHS ARE TO FULL DIA.- REMOVE BURRS AND SHARP EDGES- DO NOT SCALE PRINT- MACHINED SURFACE FINISH 3.2uM [125 uIn]
PROPRIETARY DATATHE INFORMATION AND DESIGN(S) DISCLOSEDHEREIN ARE THE PROPERTY OF MTS SYSTEMSCORPORATION AND MAY NOT BE USED,REPRODUCED OR DISCLOSED IN ANY FORMEXCEPT AS GRANTED IN WRITING BY MTSSYSTEMS CORPORATION. THIS RESTRICTIONEXCLUDES INFORMATION THAT IS IN THE PUBLIC DOMAIN OR WAS LEGITIMATELY IN THEPRIOR POSSESSION OF THE RECIPIENT.
mMTS SYSTEMS CORPORATIONSENSORS DIVISION3001 SHELDON DRIVE, CARY, NC 27513
METRIC
FIRST ANGLE 551629-3 B
1 2
DRAWN BY: NJ
A NJ
***NO REVISIONS SHALL BE MADE WITHOUT THE NOTIFICATION TO APPROVAL AGENCY(S).***
WARNING: REFER TO INSTALLATION DRAWING FOR CAUTION/WARNINGS
FM14ATEX0068XIECEx FMG 14.0032X II 1/2 G Ex ia IIC T4 Ga/Gb Ta = -50°C to +71°C ; IP65when connected in accordancewith FM approved installation drawing # 651543-3
MTS Systems CorporationSensors Division3001 Sheldon Dr.Cary, NC 27513
Model No: Serial No: Date :
USE MTS LOGO ARTWORK
10 POINT SIZE
8 POINT TEXT SIZE
4.5 POINT TEXT SIZE
MTS TO PRINTMODEL NO.SERIAL NO.
DATE CODE.
ENTITY PARAMETERS:SEE PRINT REFERENCE CHART
LEVEL
1:1
7570 RELEASE TO PRODUCTION
(ACP) LABEL, LP, IS ATEX/IECEx - DIGITAL
10/24/14
1725
Level Plus Transmitter
P/N 551629-3 Rev B
NOTES:1. STANDARD LETTERING UNIVERS 55 OR ITC GARAMOND BOOK.2. DIMENSIONS IN BRACKETS [ ] ARE IN INCHES.3. MATERIAL: 3M 7883 METALLIZED POLYESTER FOIL W/GAS RESISTANT INK.
R3.30 [.13]
1.78 [.07]
1.78 [.07]
28.70 [1.13]
15.80 [.62]
34.69 [1.37]
86.30 [3.40]
69.85 [2.75]
IP RATING WAS 66 1/19/15NJ7847B
®
1
1
2
2
A A
B B
TITLE
SIZE DWG NO. REV
PRODUCT LINESCALE: SHEET OF
UNLESS OTHERWISE SPECIFIEDTOLERANCES
0 PLACESMM
1 PLACEMM
ANGLES���� 0.5 � 0.1
- THREAD DEPTHS ARE TO MIN. FULL THDS- DRILL DEPTHS ARE TO FULL DIA.- REMOVE BURRS AND SHARP EDGES- DO NOT SCALE PRINT- MACHINED SURFACE FINISH 3.2uM [125 uIn]
PROPRIETARY DATATHE INFORMATION AND DESIGN(S) DISCLOSEDHEREIN ARE THE PROPERTY OF MTS SYSTEMSCORPORATION AND MAY NOT BE USED,REPRODUCED OR DISCLOSED IN ANY FORMEXCEPT AS GRANTED IN WRITING BY MTSSYSTEMS CORPORATION. THIS RESTRICTIONEXCLUDES INFORMATION THAT IS IN THE PUBLIC DOMAIN OR WAS LEGITIMATELY IN THEPRIOR POSSESSION OF THE RECIPIENT.
mMTS SYSTEMS CORPORATIONSENSORS DIVISION3001 SHELDON DRIVE, CARY, NC 27513
METRIC
FIRST ANGLE A 551705- C
1 1DRAWN BY: NJ
MTS Systems CorporationSensors Division3001 Sheldon Drive, Cary, N.C. 27513
II 1/2 G Ex ia IIC T4 Ga/GbTa = -50°C TO +71°C ; IP65WARNING: SUBSTITUTION OF COMPONENTS MAY IMPAIR INTRINSIC SAFETYREFER TO INSTALLATION DRAWING FOR CAUTION/WARNING.
INSTALL PER DRAWING # 651544-3SUPPLY VOLTAGE: 28 VDC
FM14ATEX0068XIECEx FMG 14.0032X
35.05 [1.38]
"L1"∆ "L2"
17.53 [.69]
7.5 POINT SIZE
USE MTS LOGO ARTWORK14.0 POINT SIZE
MTS TO PRINTMODEL NO.
SERIAL NO./DATE CODE
"D1"
4.0 POINT TEXT SIZE(TYP.)
12.70 [.50] 3.70 [.15]
(ACP) LABEL, LP, IS ATEX/IECEx - ANALOG
R
1725
�
Level Plus Transmitter
P/N 551705-X Rev C
NOTES:1. STANDARD LETTERING UNIVERS 55 OR ITC GARAMOND BOOK.2. MATERIAL TO BE SCREEN PRINTED ALUMINUM WITH SATIN BACKGROUND AND BLACK TEXT OR LASER ETCHED ALUMINUM.3. ∆ INDICATES CRITICAL DIMENSIONS.4. DIMENSIONS IN BRACKETS [ ] ARE IN INCHES5. MATERIAL: .8 [.03] THICK ALUMINUM6. REFER TO TABLE 1 FOR "L1" & "L2" DIMENSIONS.
LEVEL
1:1
SEE TABLE 1 FOR DASH #.
TABLE 1
DASH # HOUSING "L1" "L2" "D1"
-1 ADALET85.85 [3.38]
69.85 [2.75]
Ø2.35 [.09]x2
-2 LIMATHERM 65 [2.56] 58 [2.28] Ø 3.05 [.12] x2
C 8256 ADDED "D1" MS 2/22/1766 SAW GNITAR PI7487B NJ 12/2/14
A 7570 RELEASE FOR PRODUCTION NJ 10/24/14ETADYBNOITPIRCSED#OCEVER
1
1
2
2
A A
B B
TITLE
SIZE DWG NO. REV
PRODUCT LINESCALE: SHEET OF
UNLESS OTHERWISE SPECIFIEDTOLERANCES
0 PLACESMM
1 PLACEMM
ANGLES���� 0.5 � 0.1
- THREAD DEPTHS ARE TO MIN. FULL THDS- DRILL DEPTHS ARE TO FULL DIA.- REMOVE BURRS AND SHARP EDGES- DO NOT SCALE PRINT- MACHINED SURFACE FINISH 3.2uM [125 uIn]
PROPRIETARY DATATHE INFORMATION AND DESIGN(S) DISCLOSEDHEREIN ARE THE PROPERTY OF MTS SYSTEMSCORPORATION AND MAY NOT BE USED,REPRODUCED OR DISCLOSED IN ANY FORMEXCEPT AS GRANTED IN WRITING BY MTSSYSTEMS CORPORATION. THIS RESTRICTIONEXCLUDES INFORMATION THAT IS IN THE PUBLIC DOMAIN OR WAS LEGITIMATELY IN THEPRIOR POSSESSION OF THE RECIPIENT.
mMTS SYSTEMS CORPORATIONSENSORS DIVISION3001 SHELDON DRIVE, CARY, NC 27513
METRIC
FIRST ANGLE A 551703- C
1 1DRAWN BY: NJ
***NO REVISIONS SHALL BE MADE WITHOUT THE NOTIFICATION TO APPROVAL AGENCY(S).***
MTS Systems CorporationSensors Division3001 Sheldon Drive, Cary, N.C. 27513
II 1/2 G Ex ia IIC T4 Ga/GbTa = -50°C TO +71°C ; IP65WARNING: SUBSTITUTION OF COMPONENTS MAY IMPAIR INTRINSIC SAFETYREFER TO INSTALLATION DRAWING FOR CAUTION/WARNINGS
INSTALL PER DRAWING # 651543-3SUPPLY VOLTAGE: 28 VDC
FM14ATEX0068XIECEx FMG 14.0032X
35.05 [1.38]
"L1"∆ "L2"
17.53 [.69]
7.5 POINT SIZE
USE MTS LOGO ARTWORK14.0 POINT SIZE
MTS TO PRINTMODEL NO.
SERIAL NO./DATE CODE
"D1"
4.0 POINT TEXT SIZE(TYP.)
12.70 [.50] 3.70 [.15]
(ACP) LABEL, LP, IS ATEX/IECEX - DIGITAL
R
NOTES:1. STANDARD LETTERING UNIVERS 55 OR ITC GARAMOND BOOK.2. MATERIAL TO BE SCREEN PRINTED ALUMINUM WITH SATIN BACKGROUND AND BLACK TEXT OR LASER ETCHED ALUMINUM.3. ∆ INDICATES CRITICAL DIMENSIONS.4. DIMENSIONS IN BRACKETS [ ] ARE IN INCHES5. MATERIAL: .8 [.03] THICK ALUMINUM6. REFER TO TABLE 1 FOR "L1" & "L2" DIMENSIONS.
1725
�
Level Plus Transmitter
P/N 551703-X Rev C
1:1LEVEL
SEE TABLE 1 FOR DASH #.
TABLE 1
DASH # HOUSING "L1" "L2" "D1"
-1 ADALET85.85 [3.38]
69.85[2.75]
Ø2.35 [.09]x2
-2 LIMATHERM 65 [2.56] 58 [2.28] Ø 3.05 [.12] x2
C 8256 ADDED "D1" MS 2/22/1766 SAW GNITAR PI7487B NJ 12/2/14
A 7570 RELEASE FOR PRODUCTION NJ 10/24/14ETADYBNOITPIRCSED#OCEVER
Fig. 50: Etiqueta FMC de seguridad intrínseca, Modbus y DDA, carcasa NEMA
Fig. 51: Etiqueta ATEX/IECEx de seguridad intrínseca, Modbus y DDA, carcasa NEMA
Fig. 52: Etiqueta ATEX/IECEx de seguridad intrínseca, Modbus y DDA, carcasa con cavidad individual y doble
Fig. 53: Etiqueta ATEX/IECEx de seguridad intrínseca, Modbus y DDA, carcasa con cavidad individual y doble
1
1
2
2
A A
B B
REV ECO # DESCRIPTION
TITLE
SIZE DWG NO. REV
PRODUCT LINESCALE:
BY DATE
SHEET OF
UNLESS OTHERWISE SPECIFIEDTOLERANCES
0 PLACESMM
1 PLACEMM
ANGLES
0.5 0.1
- THREAD DEPTHS ARE TO MIN. FULL THDS- DRILL DEPTHS ARE TO FULL DIA.- REMOVE BURRS AND SHARP EDGES- DO NOT SCALE PRINT- MACHINED SURFACE FINISH 3.2uM [125 uIn]
PROPRIETARY DATATHE INFORMATION AND DESIGN(S) DISCLOSEDHEREIN ARE THE PROPERTY OF MTS SYSTEMSCORPORATION AND MAY NOT BE USED,REPRODUCED OR DISCLOSED IN ANY FORMEXCEPT AS GRANTED IN WRITING BY MTSSYSTEMS CORPORATION. THIS RESTRICTIONEXCLUDES INFORMATION THAT IS IN THE PUBLIC DOMAIN OR WAS LEGITIMATELY IN THEPRIOR POSSESSION OF THE RECIPIENT.
mMTS SYSTEMS CORPORATIONSENSORS DIVISION3001 SHELDON DRIVE, CARY, NC 27513
METRIC
FIRST ANGLE 551629-3 B
1 2
DRAWN BY: NJ
A NJ
***NO REVISIONS SHALL BE MADE WITHOUT THE NOTIFICATION TO APPROVAL AGENCY(S).***
WARNING: REFER TO INSTALLATION DRAWING FOR CAUTION/WARNINGS
FM14ATEX0068XIECEx FMG 14.0032X II 1/2 G Ex ia IIC T4 Ga/Gb Ta = -50°C to +71°C ; IP65when connected in accordancewith FM approved installation drawing # 651543-3
MTS Systems CorporationSensors Division3001 Sheldon Dr.Cary, NC 27513
Model No: Serial No: Date :
USE MTS LOGO ARTWORK
10 POINT SIZE
8 POINT TEXT SIZE
4.5 POINT TEXT SIZE
MTS TO PRINTMODEL NO.SERIAL NO.
DATE CODE.
ENTITY PARAMETERS:SEE PRINT REFERENCE CHART
LEVEL
1:1
7570 RELEASE TO PRODUCTION
(ACP) LABEL, LP, IS ATEX/IECEx - DIGITAL
10/24/14
1725
Level Plus Transmitter
P/N 551629-3 Rev B
NOTES:1. STANDARD LETTERING UNIVERS 55 OR ITC GARAMOND BOOK.2. DIMENSIONS IN BRACKETS [ ] ARE IN INCHES.3. MATERIAL: 3M 7883 METALLIZED POLYESTER FOIL W/GAS RESISTANT INK.
R3.30 [.13]
1.78 [.07]
1.78 [.07]
28.70 [1.13]
15.80 [.62]
34.69 [1.37]
86.30 [3.40]
69.85 [2.75]
IP RATING WAS 66 1/19/15NJ7847B
®
651544-3
551641-3
Level Plus® CON COMPARTIMIENTOSManual de funcionamiento
I 46 I
13.5.1.3 Plano de instalación
Fig. 54: Diagrama de instalación ATEX/IECEx de seguridad intrínseca, Modbus y DDA, página 1
11
22
33
44
55
66
77
88
AA
BB
CC
DD
REV
ECO
#D
ESCR
IPTION
TITLE
SIZED
WG
NO
.R
EV
PRO
DU
CT LIN
ESC
ALE:
BYD
ATE
SHEET
OF
UN
LESS OTH
ERW
ISE SPECIFIED
TOLER
ANC
ES0 PLAC
ESM
M1 PLAC
EM
MAN
GLES
0.5
0.1
- THR
EAD
DEPTH
S ARE TO
MIN
. FULL TH
DS
- DR
ILL DEPTH
S ARE TO
FULL D
IA.
- REM
OV
E BU
RR
S AND
SHAR
P E
DG
ES- D
O N
OT SC
ALE PRIN
T- M
ACH
INED
SUR
FACE
FINISH
3.2uM [125 uIn]
PRO
PRIETAR
Y DATA
THE IN
FOR
MATIO
N AN
D D
ESIG
N(S) D
ISCLO
SEDH
ERE
IN AR
E THE PR
OPER
TY OF M
TS SYSTEMS
CO
RPO
RATIO
N AN
D M
AY NO
T BE USED
,R
EPRO
DU
CED
OR
DISC
LOSED
IN A
NY FO
RM
EXCEPT AS G
RAN
TED IN
WR
ITING
BY MTS
SYSTEMS C
OR
POR
ATIO
N. TH
IS RESTR
ICTIO
NEXC
LUD
ES INFO
RM
ATION
THA
T IS IN TH
E PU
BLIC D
OM
AIN O
R W
AS LEGITIM
ATELY IN TH
EPR
IOR
POSSES
SION
OF TH
E REC
IPIENT.
mM
TS SYSTEMS C
OR
POR
ATION
SENSO
RS D
IVISION
3001 SHELD
ON
DR
IVE, CAR
Y, NC
27513
METRIC
FIRST
ANG
LED
651543-3
1 2
DR
AWN
BY: M
S
***NO
REVISIO
NS SH
ALL BE MAD
E WITH
OU
T THE N
OTIFIC
ATION
TO APPR
OVAL AG
ENC
Y(S).**
G
C 7898 UPDATED TEMPERATURE ON NOTE 12 TO 71 C M
S 2/23/15D 8037 ADDED W
IRING CHART MS 11/3/15
E 8183 ADDED CL I Zone 0/1 MS 8/18/16
F 8256 UPDATED WIRING CHART ON SHEET 2 M
S 1/30/17G 8482 UPDATED BEND RADIUS TO 15" M
S 5/17/18
24 VDC
COMM
ON- >
Rx/Tx+
Rx/Tx -
GROUND
EARTH GROUND(SEE NOTE 4)
EARTH GROUND(SEE NOTE 4)
Rx/Tx-
Rx/Tx+
GND
+24V
SAFETY BARRIER SAFETY BARRIER
SAFETY BARRIER
NO
TES:1.ALL N
ATION
AL AND
LOC
AL CO
DES AN
D R
EGU
LATION
S MU
ST BE ADH
ERED
TO W
HEN
INSTALLIN
G TH
E LEVEL SENSO
R IN
HAZAR
DO
US EN
VIRO
NM
ENTS.
SEAL ALL CO
ND
UITS W
ITHIN
457 MM
(18"). 2.LO
OP C
ABLE MU
ST BE 24 AWG
TO 14 AW
G (.511M
M² to 1.6M
M²)
SHIELD
ED TW
ISTED PAIR
CABLE W
ITH SH
IELD. C
ABLE CAPAC
ITANC
E MU
ST BE LESS TH
AN 30 pF PER
FOO
T (98 pF PER M
). CABLE SH
IELD IS C
ON
NEC
TED TO
SYSTEM G
RO
UN
D IN
NO
N-H
AZARD
OU
S AREA. SEE IN
STALLATION
MAN
UAL FO
R
ADD
ITION
AL CABLE IN
FOR
MATIO
N.
3.THE R
ESISTANC
E BETWEEN
EARTH
GR
OU
ND
AND
THE IN
TRIN
SICALLY SAFE G
RO
UN
D M
UST BE LESS TH
AN 1 O
HM
. 4.TH
E TRAN
SDU
CER
FRAM
E SHALL BE G
RO
UN
DED
TO EAR
TH G
RO
UN
D D
IREC
TLY OR
THR
OU
GH
THE EQ
UIPM
ENT O
N W
HIC
H IT IS M
OU
NTED
. 5. C
ON
TRO
L EQU
IPMEN
T CO
NN
ECTED
TO ASSO
CIATED
APPARATU
S MU
ST N
OT U
SE OR
GEN
ERATE M
OR
E THAN
250 VRM
S OR
VDC
6.ASSOC
IATED APPAR
ATUS M
ANU
FACTU
RER
'S INSTALLATIO
N D
RAW
ING
MU
ST BE FO
LLOW
ED W
HEN
INSTALLIN
G TH
IS EQU
IPMEN
T. 7.O
NLY U
SE ATEX/IEC APPR
OVED
BARR
IERS.
8.ENTITY PAR
AMETER
S: SU
PPLY: Rx/Tx-: R
x/Tx+: U
i = 28VDC
Ui= 8.6V U
i= 8.6V Ii = 100m
A Ii = 10mA Ii = 10m
A C
i = 0 µF Ci = 0 µF C
i = 0 µF Li = 0 µH
Li = 0 µH Li = 0 µH
Pi = 0.7 W Pi= 0.0215 W
P i= 0.0215 W 9.TH
E ENTITY C
ON
CEPT ALLO
WS IN
TERC
ON
NEC
TION
OF IN
TRIN
SICALLY SAFE APPAR
ATUS
WITH
ASSOC
IATED APPAR
ATUS W
HEN
THE FO
LLOW
ING
IS TRU
E: Vm
ax or Ui ≥ Voc, Vt or U
o; Im
ax or Ii ≥ Isc, It or Io; Pm
ax or Pi ≥ Po; C
a ≥ Ci + C
cable; La ≥ Li + Lcable. 10.D
UAL-C
AVITY ENC
LOSU
RES:
CU
STOM
ER C
ON
NEC
TION
S WILL BE M
ADE AT TER
MIN
AL BLOC
K ON
POW
ER SID
E O
F HO
USIN
G (N
OT TO
TERM
INAL BLO
CK O
N IN
TERC
ON
NEC
T BOAR
D).
11.FOR INSTALLATION WITHIN THE EUROPEAN UNION, SEE EN 60079-14.
12.THE M
AXIMU
M PER
MITTED
AMBIEN
T TEMPER
ATUR
E OF TH
E LEVEL PLUS D
IGITAL/AN
ALOG
LEVEL TR
ANSM
ITTER IS 71 °C
. TO AVO
ID TH
E EFFECTS O
F PRO
CESS TEM
PERATU
RE AN
D
OTH
ER TH
ERM
AL EFFECTS C
ARE SH
ALL BE TAKEN TO
ENSU
RE TH
E SUR
RO
UN
DIN
G AM
BIENT
AND
THE AM
BIENT IN
SIDE TH
E TRAN
SMITTER
HO
USIN
G D
OES N
OT EXC
EED 71°C
13.CAU
TION
: FLEXIBLE GAU
GES H
AVE A MIN
IMU
M BEN
D R
ADIU
S OF 381M
M(15")
14.WAR
NIN
G: TH
E APPARATU
S ENC
LOSU
RE C
ON
TAINS ALU
MIN
UM
AND
IS CO
NSID
ERED
TO C
ON
STITUTE A PO
TENTIAL R
ISK OF IG
NITIO
N BY IM
PACT O
R FR
ICTIO
N. C
ARE M
UST BE TAKEN
IN
TO AC
CO
UN
T DU
RIN
G IN
STALLATION
AND
USE TO
PREVEN
T IMPAC
T OR
FRIC
TION
15.WAR
NIN
G: SU
BSTITUTIO
N O
F CO
MPO
NEN
TS MAY IM
PAIR IN
TRIN
SIC SAFETY.
16.WAR
NIN
G: TO
PREVEN
T IGN
ITION
OF FLAM
MABLE O
R C
OM
BUSTIBLE ATM
OSPH
ERES,
DISC
ON
NEC
T POW
ER BEFO
RE SER
VICIN
G
17.WAR
NIN
G: TH
E EQU
IPMEN
T CO
NTAIN
S NO
N-M
ETALLIC EN
CLO
SUR
E PARTS, TO
PREVEN
T TH
E RISK O
F ELECTR
OSTATIC
SPARKIN
G. TH
E NO
N-M
ETALLIC SU
RFAC
E SHO
ULD
ON
LY BE C
LEANED
WITH
A DAM
P CLO
TH.
NON HAZARDOUS LOCATIONHAZARDOUS LOCATION
INTR
INSIC
ALLY SAFEFM
14ATEX0068XIEC
Ex FMG
14.0032X
AGEN
CY C
ON
TRO
LLED D
RAW
ING
(ATEX/IEC). N
O C
HAN
GES W
ITHO
UT PR
IOR
AGEN
CY APPR
OVAL
EARTH TERMINAL
(ACP) INSTALLATIN DWG LP DIGITAL
INTRINSICALLY SAFE FOR ATEX/IEC
7570
LEVELN/A
1725
II 1/2 G Ex ia T4 Ga/GbTa =
-50 TO 71°C; IP65
Level Plus® CON COMPARTIMIENTOSManual de funcionamiento
I 47 I
Fig. 55: Diagrama de instalación ATEX/IECEx de seguridad intrínseca, Modbus y DDA, página 2
DETAIL ASCALE 1.60 : 1
DETAIL CSCALE 3 : 1
DETAIL DSCALE 1.2
DETAIL ESCALE 1 : 1
A
C
D
E
11
22
33
44
55
66
77
88
AA
BB
CC
DD
REV
ECO
#D
ESCR
IPTION
TITLE
SIZED
WG
NO
.R
EV
PRO
DU
CT LIN
ESC
ALE:
BYD
ATE
SHEET
OF
UN
LESS OTH
ERW
ISE SPECIFIED
TOLER
ANC
ES0 PLAC
ESM
M1 PLAC
EM
MAN
GLES
0.5
0.1
- THR
EAD
DEPTH
S ARE TO
MIN
. FULL TH
DS
- DR
ILL DEPTH
S ARE TO
FULL D
IA.
- REM
OV
E BU
RR
S AND
SHAR
P E
DG
ES- D
O N
OT SC
ALE PRIN
T- M
ACH
INED
SUR
FACE
FINISH
3.2uM [125 uIn]
PRO
PRIETAR
Y DATA
THE IN
FOR
MATIO
N AN
D D
ESIG
N(S) D
ISCLO
SEDH
ERE
IN AR
E THE PR
OPER
TY OF M
TS SYSTEMS
CO
RPO
RATIO
N AN
D M
AY NO
T BE USED
,R
EPRO
DU
CED
OR
DISC
LOSED
IN A
NY FO
RM
EXCEPT AS G
RAN
TED IN
WR
ITING
BY MTS
SYSTEMS C
OR
POR
ATIO
N. TH
IS RESTR
ICTIO
NEXC
LUD
ES INFO
RM
ATION
THA
T IS IN TH
E PU
BLIC D
OM
AIN O
R W
AS LEGITIM
ATELY IN TH
EPR
IOR
POSSES
SION
OF TH
E REC
IPIENT.
mM
TS SYSTEMS C
OR
POR
ATION
SENSO
RS D
IVISION
3001 SHELD
ON
DR
IVE, CAR
Y, NC
27513
METRIC
FIRST
ANG
LED
651543-3
2 2
DR
AWN
BY: M
S
***NO
REVISIO
NS SH
ALL BE MAD
E WITH
OU
T THE N
OTIFIC
ATION
TO APPR
OVAL AG
ENC
Y(S).**
G
C 7898 UPDATED TEMPERATURE ON NOTE 12 TO 71 C M
S 2/23/15D 8037 ADDED W
IRING CHART MS 11/3/15
E 8183 ADDED CL I Zone 0/1 MS 8/18/16
F 8256 UPDATED WIRING CHART ON SHEET 2 M
S 1/30/17G 8482 UPDATED BEND RADIUS TO 15" M
S 5/17/18
+24V GNDEARTHTX/RX+TX/RX-
GND+24V
TX/RX-TX/RX+EARTH
GND+24V
TX/RX-
TX/RX+
EARTH
FIGU
RE 1
SING
LE CAVITY & N
EMA H
OU
SING
FIGU
RE 2
DU
AL CAVITY H
OU
SING
NO
TES: 1. TH
E CU
STOM
ER SH
OU
LD C
ON
NEC
T THE O
UTSID
E GR
OU
ND
LUG
TO TH
E SAFETY EARTH
ING
GR
OU
ND
SYSTEM W
ARN
ING
: C
ON
DU
IT SEALS REQ
UIR
ED W
ITHIN
457 MM
(18") OF H
OU
SING
.
(ACP) INSTALLATIN DWG LP DIGITAL
INTRINSICALLY SAFE FOR ATEX/IEC
+24V GND EARTH Tx/Rx+ Tx/Rx-
7570
WIRING CHART (FOR NEM
A GAUGE)
PIN WIRING CHART (FOR NEM
A GAUGE)
WIRE COLOR
SIGNALRED
24 V PWR
BLACK 0 V PW
RBLUE
N/AW
HITERX TX +
GREENRX TX -
DRAIN WIRE
EARTH GROUND
PIN #SIGNAL
PIN 124 V PW
RPIN 2
0 V PWR
PIN 3N/A
PIN 4RX TX+
PIN 5RX TX-
PIN 6EARTH GROUND
Level Plus® CON COMPARTIMIENTOSManual de funcionamiento
I 48 I
Fig. 56: Diagrama de instalación ATEX/IECEx de seguridad intrínseca, HART®, página 1
11
22
33
44
55
66
77
88
AA
BB
CC
DD
REV
ECO
#D
ESCR
IPTION
TITLE
SIZED
WG
NO
.R
EV
PRO
DU
CT LIN
ESC
ALE:
BYD
ATE
SHEET
OF
UN
LESS OTH
ERW
ISE SPECIFIED
TOLER
ANC
ES0 PLAC
ESM
M1 PLAC
EM
MAN
GLES
0.5
0.1
- THR
EAD
DEPTH
S ARE TO
MIN
. FULL TH
DS
- DR
ILL DEPTH
S ARE TO
FULL D
IA.
- REM
OV
E BU
RR
S AND
SHAR
P E
DG
ES- D
O N
OT SC
ALE PRIN
T- M
ACH
INED
SUR
FACE
FINISH
3.2uM [125 uIn]
PRO
PRIETAR
Y DATA
THE IN
FOR
MATIO
N AN
D D
ESIG
N(S) D
ISCLO
SEDH
ERE
IN AR
E THE PR
OPER
TY OF M
TS SYSTEMS
CO
RPO
RATIO
N AN
D M
AY NO
T BE USED
,R
EPRO
DU
CED
OR
DISC
LOSED
IN A
NY FO
RM
EXCEPT AS G
RAN
TED IN
WR
ITING
BY MTS
SYSTEMS C
OR
POR
ATIO
N. TH
IS RESTR
ICTIO
NEXC
LUD
ES INFO
RM
ATION
THA
T IS IN TH
E PU
BLIC D
OM
AIN O
R W
AS LEGITIM
ATELY IN TH
EPR
IOR
POSSES
SION
OF TH
E REC
IPIENT.
mM
TS SYSTEMS C
OR
POR
ATION
SENSO
RS D
IVISION
3001 SHELD
ON
DR
IVE, CAR
Y, NC
27513
METRIC
FIRST
ANG
LED
651544-3LEVEL
1 2
DR
AWN
BY: M
S
***NO
REVISIO
NS SH
ALL BE MAD
E WITH
OU
T THE N
OTIFIC
ATION
TO APPR
OVAL AG
ENC
Y(S).**
G
C 7898 UPDATED TEMPERATURE ON NOTE 12 TO 71 C M
S 2/23/15D 8037 ADDED W
IRING CHART MS 11/3/15
E 8183 ADDED CL I Zone 0/1 MS 8/18/16
F 8256 UPDATED WIRING CHART ON SHEET 2 M
S 1/30/17G 8482 UPDATED BEND RADIUS TO 15" M
S 5/17/18
NO
N H
AZARD
OU
S LOC
ATION
HAZAR
DO
US LO
CATIO
N
NO
TES: 1. ALL N
ATION
AL AND
LOC
AL CO
DES AN
D R
EGU
LATION
S MU
ST BE ADH
ERED
TO W
HEN
INSTALLIN
G TH
E MTS LP SEN
SOR
IN H
AZARD
OU
S ENVIR
ON
MEN
TS. SEAL ALL C
ON
DU
ITS WITH
IN 457 M
M (18").
2. LOO
P CABLE M
UST BE 24 AW
G TO
14 AWG
(.511MM
² to 1.6MM
²) SH
IELDED
TWISTED
PAIR C
ABLE WITH
SHIELD
. CABLE C
APACITAN
CE M
UST
BE LESS THAN
30 pF PER FO
OT (98 pF PER
m). C
ABLE SH
IELD IS C
ON
NEC
TED TO
SYSTEM G
RO
UN
D IN
NO
N-H
AZARD
OU
S AREA. SEE IN
STALLATION
MAN
UAL FO
R
ADD
ITION
AL CABLE IN
FOR
MATIO
N.
3. THE R
ESISTANC
E BETWEEN
EARTH
GR
OU
ND
AND
THE IN
TRIN
SICALLY SAFE G
RO
UN
D M
UST BE LESS TH
AN 1 O
HM
. 4. TH
E TRAN
SDU
CER
FRAM
E SHALL BE G
RO
UN
DED
TO EAR
TH G
RO
UN
D D
IREC
TLY OR
THR
OU
GH
THE EQ
UIPM
ENT O
N W
HIC
H IT IS M
OU
NTED
. 5. C
ON
TRO
L EQU
IPMEN
T CO
NN
ECTED
TO ASSO
CIATED
APPARATU
S MU
ST N
OT U
SE OR
GEN
ERATE M
OR
E THAN
250 VRM
S OR
VDC.
6. ASSOC
IATED APPAR
ATUS M
ANU
FACTU
RER
'S INSTALLATIO
N D
RAW
ING
MU
ST BE FO
LLOW
ED W
HEN
INSTALLIN
G TH
IS EQU
IPMEN
T 7. O
NLY U
SE ATEX/IEC APPR
OVED
BARR
IERS.
8. APPRO
VED LO
OP SEPAR
ATION
METH
OD
S: *R
UN
LOO
PS IN SEPAR
ATE CABLES
*RU
N LO
OPS IN
SEPARATE G
RO
UN
DED
SHIELD
S 9. EN
TITY PARAM
ETERS EAC
H LO
OP:
Ui = 28 VD
C Ii = 120 m
A C
i = 0 µF Li = 5 µH Pi = 840 m
W 10. D
UAL-C
AVITY ENC
LOSU
RES:
CU
STOM
ER C
ON
NEC
TION
S WILL BE M
ADE AT TER
MIN
AL BLOC
K ON
POW
ER SID
E O
F HO
USIN
G (N
OT TO
TERM
INAL BLO
CK O
N IN
TERC
ON
NEC
T BOAR
D)
11 FOR
INSTALLATIO
N W
ITHIN
THE EU
RO
PEAN U
NIO
N, SEE EN
60079-14. 12.TH
E MAXIM
UM
PERM
ITTED AM
BIENT TEM
PERATU
RE O
F THE LEVEL PLU
S DIG
ITAL/ANALO
G
LEVEL TRAN
SMITTER
IS 71 °C. TO
AVOID
THE EFFEC
TS OF PR
OC
ESS TEMPER
ATUR
E AND
O
THER
THER
MAL EFFEC
TS CAR
E SHALL BE TAKEN
TO EN
SUR
E THE SU
RR
OU
ND
ING
AMBIEN
T AN
D TH
E AMBIEN
T INSID
E THE TR
ANSM
ITTER H
OU
SING
DO
ES NO
T EXCEED
71°C 13.C
AUTIO
N: FLEXIBLE G
AUG
ES HAVE A M
INIM
UM
BEND
RAD
IUS O
F 381MM
(15") 14. W
ARN
ING
: THE APPAR
ATUS EN
CLO
SUR
E CO
NTAIN
S ALUM
INU
M AN
D IS C
ON
SIDER
ED TO
CO
NSTITU
TE A PO
TENTIAL R
ISK OF IG
NITIO
N BY IM
PACT O
R FR
ICTIO
N. C
ARE M
UST BE TAKEN
IN
TO AC
CO
UN
T DU
RIN
G IN
STALLATION
AND
USE TO
PREVEN
T IMPAC
T OR
FRIC
TION
15.WAR
NIN
G: SU
BSTITUTIO
N O
F CO
MPO
NEN
TS MAY IM
PAIR IN
TRIN
SIC SAFETY.
16.WAR
NIN
G: TO
PREVEN
T IGN
ITION
OF FLAM
MABLE O
R C
OM
BUSTIBLE ATM
OSPH
ERES.
DISC
ON
NEC
T POW
ER BEFO
RE SER
VICIN
G.
17.WAR
NIN
G: TH
E EQU
IPMEN
T CO
NTAIN
S NO
N-M
ETALLIC EN
CLO
SUR
E PARTS, TO
PREVEN
T TH
E RISK O
F ELECTR
OSTATIC
SPARKIN
G. TH
E NO
N-M
ETALLIC SU
RFAC
E SHO
ULD
ON
LY BE C
LEANED
WITH
A DAM
P CLO
TH.
EARTH
GR
OU
ND
LUG
NO
TE 3
AGEN
CY C
ON
TRO
LLED D
RAW
ING
(ATEX/IEC). N
O C
HAN
GES W
ITHO
UT PR
IOR
AGEN
CY APPR
OVAL
24 VDC
CO
NTR
OL
INPU
T 1
CO
NTR
OL
INPU
T 2
APPRO
VED SAFETY
BARR
IER
APPRO
VED SAFETY
BARR
IER
LOO
P VOLTAG
E
SHIELD
SHIELD
LOO
P 1+
LOO
P 1-
LOO
P 2+
LOO
P 2-
(ACP) INSTALLATIN DWG LP ANALOG
INTRINSICALLY SAFE FOR ATEX/IEC
SING
LE OR
DU
AL CAVITY
NEM
A HO
USIN
G
E
II 1/2 G Ex ia T4 Ga/GbTa =
-50 TO 71°C; IP65
INTR
INSIC
ALLY SAFEFM
14ATEX0068XIEC
Ex FMG
14.0032X
1725
EARTH
GR
OU
ND
(SEE N
OTE 4)
EARTH
GR
OU
ND
(SEE N
OTE 4)
Level Plus® CON COMPARTIMIENTOSManual de funcionamiento
I 49 I
Fig. 57: Diagrama de instalación ATEX/IECEx de seguridad intrínseca, HART®, página 2
DETAIL D
SCALE 3
DETAIL E
SCALE 1.60
DETAIL F
SCALE 1.2
DETAIL H
SCALE 1 : 1
D
E
F
H
11
22
33
44
55
66
77
88
AA
BB
CC
DD
REV
ECO
#D
ESCR
IPTION
TITLE
SIZED
WG
NO
.R
EV
PRO
DU
CT LIN
ESC
ALE:
BYD
ATE
SHEET
OF
UN
LESS OTH
ERW
ISE SPECIFIED
TOLER
ANC
ES0 PLAC
ESM
M1 PLAC
EM
MAN
GLES
0.5
0.1
- THR
EAD
DEPTH
S ARE TO
MIN
. FULL TH
DS
- DR
ILL DEPTH
S ARE TO
FULL D
IA.
- REM
OV
E BU
RR
S AND
SHAR
P E
DG
ES- D
O N
OT SC
ALE PRIN
T- M
ACH
INED
SUR
FACE
FINISH
3.2uM [125 uIn]
PRO
PRIETAR
Y DATA
THE IN
FOR
MATIO
N AN
D D
ESIG
N(S) D
ISCLO
SEDH
ERE
IN AR
E THE PR
OPER
TY OF M
TS SYSTEMS
CO
RPO
RATIO
N AN
D M
AY NO
T BE USED
,R
EPRO
DU
CED
OR
DISC
LOSED
IN A
NY FO
RM
EXCEPT AS G
RAN
TED IN
WR
ITING
BY MTS
SYSTEMS C
OR
POR
ATIO
N. TH
IS RESTR
ICTIO
NEXC
LUD
ES INFO
RM
ATION
THA
T IS IN TH
E PU
BLIC D
OM
AIN O
R W
AS LEGITIM
ATELY IN TH
EPR
IOR
POSSES
SION
OF TH
E REC
IPIENT.
mM
TS SYSTEMS C
OR
POR
ATION
SENSO
RS D
IVISION
3001 SHELD
ON
DR
IVE, CAR
Y, NC
27513
METRIC
FIRST
ANG
LED
651544-3LEVEL
2 2
DR
AWN
BY: M
S
***NO
REVISIO
NS SH
ALL BE MAD
E WITH
OU
T THE N
OTIFIC
ATION
TO APPR
OVAL AG
ENC
Y(S).**
G
C 7898 UPDATED TEMPERATURE ON NOTE 12 TO 71 C M
S 2/23/15D 8037 ADDED W
IRING CHART MS 11/3/15
E 8183 ADDED CL I Zone 0/1 MS 8/18/16
F 8256 UPDATED WIRING CHART ON SHEET 2 M
S 1/30/17G 8482 UPDATED BEND RADIUS TO 15" M
S 5/17/18
LOOP 2-
LOOP 2+
EARTH
LOOP 1-
LOOP 1+
NO
TES: 1. TH
E CU
STOM
ER SH
OU
LD C
ON
NEC
T THE O
UTSID
E GR
OU
ND
LUG
TO TH
E SAFETY EARTH
ING
GR
OU
ND
SYSTEM W
ARN
ING
: C
ON
DU
IT SEALS REQ
UIR
ED W
ITHIN
457 MM
(18") OF H
OU
SING
.
FIGU
RE 2
DU
AL CAVITY H
OU
SING
LOOP 1+ LOOP 1- EARTH LOOP 2+ LOOP 2-
FIGU
RE 1
SING
LE CAVITY & N
EMA H
OU
SING
LOOP 1+ LOOP 1- EARTH LOOP 2+ LOOP 2-
(ACP) IN
STALLATION
DW
G LP AN
ALGO
IN
TRIN
SICALLY SAFE ATEX/IEC
E
LOOP 1+ LOOP 1- EARTH LOOP 2+ LOOP 2-
E
WIRING CHART( FOR NEM
A GAUGE)
PIN WIRING CHART (FOR NEM
A GAUGE)
WIRE COLOR
SIGNALRED
LOOP 1+BLACK
LOOP 1-BLUE
LOOP 2-W
HITELOOP 2+
GREENN/A
DRAIN WIRE
EARTH GROUND
PIN #SIGNAL
PIN 1LOOP 1-
PIN 2LOOP 1+
PIN 3LOOP 2-
PIN 4LOOP 2+
PIN 5N/A
PIN 6EARTH GROUND
Level Plus® CON COMPARTIMIENTOSManual de funcionamiento
I 50 I
13.5.2 Resistente a explosiones/ignífugo
13.5.2.1 Condiciones específicas para un uso seguro
1. Advertencia: El equipo contiene piezas no metálicas de la carcasa y de proceso para evitar el riesgo de chispas electrostáticas. La superficie no metálica se debe limpiar solo con un paño húmedo. La superficie pintada del equipo puede almacenar carga electrostática y convertirse en fuente de ignición en aplicaciones con una humedad relativa baja con <~30% de humedad relativa donde la superficie pintada está relativamente libre de contaminación (suciedad, polvo o aceite). La limpieza de la superficie pintada solo debe hacerse con un paño húmedo.
2. Los cables deben tener una clasificación de uso de > 5 °C por encima de la temperatura ambiente máxima.
3. Para mantener la clasificación de protección de IP65, se debe usar cinta Teflon™ (3 vueltas) o grasa para tubería. Consulte las instrucciones de instalación.
4. El equipo se puede instalar en una configuración de pared, en la cual la conexión del proceso se instala como equipo de Categoría 1G y la carcasa del transmisor se instala como equipo de Categoría 2G. Consulte las instrucciones de instalación.
5. Los medidores flexibles cuentan con un radio mínimo de curvatura de 381 mm (15 in).
6. La trayectoria de la flama no es para reparación. 7. La clase de temperatura, el rango de temperatura ambiente
y el rango de temperatura del proceso aplicables del equipo son las que siguen:• T3 con rango de temperatura del proceso de −40 °C a +150 °C• T4 con rango de temperatura del proceso de −40 °C a +135 °C• T5 con rango de temperatura del proceso de −40 °C a +100 °C• T6 con rango de temperatura del proceso de −40 °C a +85 °C• El rango de temperatura ambiente es −40 °C ≤ Ta ≤ 71 °C
8. Durante el montaje del MLG (medidor de nivel magnético), asegúrese de que el cabezal electrónico y la barrera de presión cuenten con un espaciado de al menos 5 pulgadas. Consulte el Manual de instalación para obtener más información.
Fig. 58: Ignífugo, etiqueta ATEX/IECEx, Modbus o DDA, opción de carcasa D, E, G, H o L
Fig. 59: Ignífugo, etiqueta ATEX/IECEx, HART®, opción de carcasa D, E, G, H o L
1
1
2
2
A A
B B
REV ECO # DESCRIPTION
TITLE
SIZE DWG NO. REV
PRODUCT LINESCALE:
BY DATE
SHEET OF
UNLESS OTHERWISE SPECIFIEDTOLERANCES
0 PLACESMM
1 PLACEMM
ANGLES� � �� 0.5 � 0.1
- THREAD DEPTHS ARE TO MIN. FULL THDS- DRILL DEPTHS ARE TO FULL DIA.- REMOVE BURRS AND SHARP EDGES- DO NOT SCALE PRINT- MACHINED SURFACE FINISH 3.2uM [125 uIn]
PROPRIETARY DATATHE INFORMATION AND DESIGN(S) DISCLOSEDHEREIN ARE THE PROPERTY OF MTS SYSTEMSCORPORATION AND MAY NOT BE USED,REPRODUCED OR DISCLOSED IN ANY FORMEXCEPT AS GRANTED IN WRITING BY MTSSYSTEMS CORPORATION. THIS RESTRICTIONEXCLUDES INFORMATION THAT IS IN THE PUBLIC DOMAIN OR WAS LEGITIMATELY IN THEPRIOR POSSESSION OF THE RECIPIENT.
mMTS SYSTEMS CORPORATIONSENSORS DIVISION3001 SHELDON DRIVE, CARY, NC 27513
METR IC
FIRST ANGLE A 551707-X A
1 1
DRAWN BY: MS
***NO REVISIONS SHALL BE MADE WITHOUT THE NOTIFICATION TO APPROVAL AGENCY(S).***A MS 2/12/18
FM16ATEX0068XIECEx FMG 16.0033X
Level Plus TransmitterMTS Systems CorporationSensors Division3001 Sheldon Drive, Cary, N.C. 27513 U.S.A
�
WARNING: DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE IS PRESENT. POTENTIAL ELECTROSTATIC CHARGING HAZARD - SEE INSTRUCTIONS
MAX. PRESSURE 1000 PSI (RIGID SENSOR)MAX. PRESSURE 435 PSI (FLEX SENSOR)
INSTALL PER DRAWING # 651552-3
II 1/2 G Ex db IIB+H2 T6...T3 Ga/Gb Ta = -40°C to +71°C ; IP65 INPUT: 28V (120mA) maxOUTPUT: RS485
38.00 [1.50]
"L1"
∆ "L2"
19.00 [.75]
4.2 POINT SIZEUSE MTS LOGO ARTWORK
11.0 POINT SIZE
MTS TO PRINTMODEL NO.
REFER TO DRAWING# 280743
SERIAL NO./DATE CODE"D1"
7570 RELEASE FOR PRODUCTION
(ACP) LABEL, LP, XP ATEX/IECEx - DIGITAL
NOTES:1. STANDARD LETTERING UNIVERS 55 OR ITC GARAMOND BOOK.2. MATERIAL TO BE SCREEN PRINTED ALUMINUM WITH SATIN BACKGROUND AND BLACK TEXT OR LASER ETCHED ALUMINUM.3. ∆ INDICATES CRITICAL DIMENSIONS.4. DIMENSIONS IN BRACKETS [ ] ARE IN INCHES5. MATERIAL: .8 [.03] THICK ALUMINUM.6. REFER TO TABLE 1 FOR "L1" & "L2" DIMENSIONS.
1725
P/N 551707-X Rev A
1:1LEVEL
4.2 POINT TEXT SIZE(TYP.)
SEE TABLE 1 FOR DASH #.
CE LOGO TO BE 5mm MINIMUM
TABLE 1DASH
# HOUSING GROUPS "L1" "L2" "D1"
-1ADALET [403892, 403890,403889] B,C,D 85.85
[3.38]69.85 [2.75]
Ø2.35 [.09]x2
-2LIMATHERM
[403812, 403813] A,B,C,D 65 [2.56] 58 [2.28] Ø 3.05
[.12] x2
!
R
7. POINT TEXT SIZE
1
1
2
2
A A
B B
REV ECO # DESCRIPTION
TITLE
SIZE DWG NO. REV
PRODUCT LINESCALE:
BY DATE
SHEET OF
UNLESS OTHERWISE SPECIFIEDTOLERANCES
0 PLACESMM
1 PLACEMM
ANGLES� � �� 0.5 � 0.1
- THREAD DEPTHS ARE TO MIN. FULL THDS- DRILL DEPTHS ARE TO FULL DIA.- REMOVE BURRS AND SHARP EDGES- DO NOT SCALE PRINT- MACHINED SURFACE FINISH 3.2uM [125 uIn]
PROPRIETARY DATATHE INFORMATION AND DESIGN(S) DISCLOSEDHEREIN ARE THE PROPERTY OF MTS SYSTEMSCORPORATION AND MAY NOT BE USED,REPRODUCED OR DISCLOSED IN ANY FORMEXCEPT AS GRANTED IN WRITING BY MTSSYSTEMS CORPORATION. THIS RESTRICTIONEXCLUDES INFORMATION THAT IS IN THE PUBLIC DOMAIN OR WAS LEGITIMATELY IN THEPRIOR POSSESSION OF THE RECIPIENT.
mMTS SYSTEMS CORPORATIONSENSORS DIVISION3001 SHELDON DRIVE, CARY, NC 27513
METR IC
FIRST ANGLE A 551709- A
1 1
DRAWN BY: MS
***NO REVISIONS SHALL BE MADE WITHOUT THE NOTIFICATION TO APPROVAL AGENCY(S).***A MS 2/12/18
FM16ATEX0068XIECEx FMG 16.0033X
Level Plus TransmitterMTS Systems CorporationSensors Division3001 Sheldon Drive, Cary, N.C. 27513U.S.A
�
II 1/2 G Ex db IIB+H2 T6...T3 Ga/Gb Ta = -40°C to +71°C ; IP65 INPUT: 28V (120mA) maxOUTPUT: 4-20mA
MAX. PRESSURE 1000 PSI (RIGID SENSOR)MAX. PRESSURE 435 PSI (FLEX SENSOR)
INSTALL PER DRAWING # 651553-3
WARNING: DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE IS PRESENT. POTENTIAL ELECTROSTATIC CHARGING HAZARD - SEE INSTRUCTIONS
38.00 [1.50]
"L1"
∆ "L2"
19.00 [.75]
4.2 POINT SIZE
USE MTS LOGO ARTWORK11.0 POINT SIZE
MTS TO PRINT
MODEL NO.REFER TO DRAWING #280743
SERIAL NO./DATE CODE
"D1"
7957 RELEASE FOR PRODUCTION
(ACP) LABEL, LP, XP ATEX/IECEx - ANALOG
NOTES:1. STANDARD LETTERING UNIVERS 55 OR ITC GARAMOND BOOK.2. MATERIAL TO BE SCREEN PRINTED ALUMINUM WITH SATIN BACKGROUND AND BLACK TEXT OR LASER ETCHED ALUMINUM.3. ∆ INDICATES CRITICAL DIMENSIONS.4. DIMENSIONS IN BRACKETS [ ] ARE IN INCHES5. MATERIAL: .8 [0.03] THICK ALUMINUM.6. REFER TO TABLE 1 FOR "L1" & "L2" DIMENSIONS.
1725
P/N 551709- Rev A
1:1LEVEL
4.2 POINT TEXT SIZE(TYP.)
SEE TABLE 1 FOR DASH #.
CE LOGO TO BE 5mm MINIMUM
TABLE 1DASH
# HOUSING GROUPS "L1" "L2" "D1"
-1ADALET [403892, 403890,403889] B,C,D 85.85
[3.38]69.85 [2.75]
Ø2.35 [.09]x2
-2LIMATHERM
[403812, 403813] A,B,C,D 65 [2.56] 58 [2.28] Ø 3.05
[.12] x2
!
R
7. POINT TEXT SIZE
13.5.2.2 Etiquetas
Level Plus® CON COMPARTIMIENTOSManual de funcionamiento
I 51 I
13.5.2.3 Plano de instalación
Fig. 60: Ignífugo, plano de instalación ATEX/IECEx, Modbus y DDA, página 1
11
22
33
44
55
66
77
88
AA
BB
CC
DD
REV
ECO
#D
ESCR
IPTION
TITLE
SIZED
WG
NO
.R
EV
PRO
DU
CT LIN
ESC
ALE:
BYD
ATE
SHEET
OF
UN
LESS OTH
ERW
ISE SPECIFIED
TOLER
ANC
ES0 PLAC
ESM
M1 PLAC
EM
MAN
GLES
0.5
0.1
- THR
EAD
DEPTH
S ARE TO
MIN
. FULL TH
DS
- DR
ILL DEPTH
S ARE TO
FULL D
IA.
- REM
OV
E BU
RR
S AND
SHAR
P E
DG
ES- D
O N
OT SC
ALE PRIN
T- M
ACH
INED
SUR
FACE
FINISH
3.2uM [125 uIn]
PRO
PRIETAR
Y DATA
THE IN
FOR
MATIO
N AN
D D
ESIG
N(S) D
ISCLO
SEDH
ERE
IN AR
E THE PR
OPER
TY OF M
TS SYSTEMS
CO
RPO
RATIO
N AN
D M
AY NO
T BE USED
,R
EPRO
DU
CED
OR
DISC
LOSED
IN A
NY FO
RM
EXCEPT AS G
RAN
TED IN
WR
ITING
BY MTS
SYSTEMS C
OR
POR
ATIO
N. TH
IS RESTR
ICTIO
NEXC
LUD
ES INFO
RM
ATION
THA
T IS IN TH
E PU
BLIC D
OM
AIN O
R W
AS LEGITIM
ATELY IN TH
EPR
IOR
POSSES
SION
OF TH
E REC
IPIENT.
mM
TS SYSTEMS C
OR
POR
ATION
SENSO
RS D
IVISION
3001 SHELD
ON
DR
IVE, CAR
Y, NC
27513
METRIC
FIRST
ANG
LED
651553-3B
LEVEL1
2 D
RAW
N BY:
MS
***NO
REVISIO
NS SH
ALL BE MAD
E WITH
OU
T THE N
OTIFIC
ATION
TO APPR
OVAL AG
ENC
Y(S).***B
MS
10/22/15RELEASE TO PRODUCTION
8482UPDATED W
IRING DWG TO ANALOG
MS
5/17/18A
7957
EARTH GROUND
LOOP 2-
LOOP 2+
EARTH GROUND
LOOP 1-
LOOP 1+
NO
N H
AZARD
OU
S LOC
ATION
HAZAR
DO
US LO
CATIO
N
EARTH
GR
OU
ND
LUG
NO
TE 3
AGEN
CY C
ON
TRO
LLED D
RAW
ING
(ATEX/IEC). N
O C
HAN
GES W
ITHO
UT PR
IOR
AGEN
CY APPR
OVAL
(ACP) INSTALLATION DWG LP ANALOG
EXPLOSION PROOF ATEX/IEC
SING
LE OR
DU
AL CAVITY
1725For ATEX - FM
16ATEX0068XFor IECEx - IECEx FM
G 16.0033X
AREA R
EQU
IRIN
G
EPL Gb
AREA R
EQU
IRIN
G
EPL Ga
CO
ND
UIT JU
NC
TION
CO
ND
UIT
SEE NO
TE 1
SEE NO
TE 8
II 1/2 G Ex db IIB+H2 T6...T3 Ga/GbTa = -40°C to +71°C; IP65
CATEG
OR
Y 1
CATEG
OR
Y 2
NO
TES:1.ALL N
ATION
AL AND
LOC
AL CO
DES AN
D R
EGU
LATION
S MU
ST BE ADH
ERED
TO W
HEN
INSTALLIN
G TH
E LEVEL SENSO
R IN
HAZAR
DO
US EN
VIRO
NM
ENTS.
SEAL ALL CO
ND
UITS W
ITHIN
50mm
OF EN
CLO
SUR
E.2.D
UAL-C
AVITY ENC
LOSU
RES:
CU
STOM
ER C
ON
NEC
TION
S WILL BE M
ADE AT TER
MIN
AL BLOC
K ON
POW
ER SID
E O
F HO
USIN
G (N
OT TO
T ERM
INAL BLO
CK O
N IN
TERC
ON
NEC
T BOAR
D). SEE FIG
UR
E 2 ON
PAGE 2
3. CAU
TION
: FLEXIBLE GAU
GES H
AVE A MIN
IMU
M BEN
D R
ADIU
S OF 381m
m(15")
4.WAR
NIN
G: TO
PREVEN
T IGN
ITION
OF FLAM
MABLE O
R C
OM
BUSTIBLE ATM
OSPH
ERES,
DISC
ON
NEC
T POW
ER BEFO
RE SER
VICIN
G
5.WAR
NIN
G: TH
E EQU
IPMEN
T CO
NTAIN
S NO
N-M
ETALLIC EN
CLO
SUR
E AND
PRO
CESS PAR
TS, TO PR
EVENT
THE R
ISK OF ELEC
TRO
STATIC SPAR
KING
. THE N
ON
-METALLIC
SUR
FACE AN
D PR
OC ESS PAR
TS SHO
ULD
ON
LY BE C
LEANED
WITH
A DAM
P CLO
TH. PAINTED SURFACE OF THE EQUIPM
ENT MAY STORE ELECTROSTATIC CHARGE
AND BECOME A SOURCE OF IGNITION IN APPLICATIONS W
ITH A LOW RELATIVE HUM
IDITY <~30%
RELATIVE HUM
IDITY WHERE THE PAINTED SURFACE IS RELATIVELY FREE OF SURFACE CONTAM
INATION SUCH AS DIRT, DUST OR OIL. CLEANING OF THE PAINTED SURFACE SHOULD ONLY BE DONE W
ITH A DAMP CLOT H.
6. CABLES SH
ALL BE RATED
> 5C ABO
VE MAXIM
UM
AMBIEN
T TEMPER
ATUR
E. 7. TO
MAIN
TAIN TH
E ING
RESS PR
OTEC
TION
RATIN
G O
F IP65, TEFLON
TAPE (3 WR
APS) OR
PIPE DO
PE SHALL
BE USED
. REFER
TO IN
STALLATION
INSTR
UC
TION
S.8. TH
E EQU
IPMEN
T CAN
BE INSTALLED
IN TH
E BOU
ND
ARY W
ALL BETWEEN
AN EPL G
a AREA AN
D TH
E LESS H
AZARD
OU
S AREA, EPL G
b. IN TH
IS CO
NFIG
UR
ATION
, THE PR
OC
ESS CO
NN
ECTIO
N IS IN
STALLED
IN EPL G
a, WH
ILE THE TR
ANSM
ITTER H
OU
SING
IS INSTALLED
IN EPL G
b. REFER
TO IN
STALLATION
IN
STRU
CTIO
NS.
EQU
IPMEN
T CAN
BE INSTALLED
IN A BO
UN
DAR
Y WALL C
ON
FIGU
RATIO
N W
HER
E THE PR
OC
ESS CO
NN
ECTIO
N IS IN
STALLED AS C
ATEGO
RY 1G
EQU
IPMEN
T WH
ILE THE TR
ANSM
ITTER H
OU
SING
IS INSTALLED
AS C
ATEGO
RY 2G
EQU
IPMEN
T. REFER
TO IN
STALLATION
INSTR
UC
TION
S 9. TH
E APPLICABLE TEM
PERATU
RE C
LASS OF TH
E EQU
IPMEN
T, AMBIEN
T TEMPER
ATUR
E RAN
GE,
AND
MAXIM
UM
PRO
CESS TEM
PERATU
RE O
F THE EQ
UIPM
ENT IS AS FO
LLOW
S; T3 W
ITH PR
OC
ESS TEMPER
ATUR
E RAN
GE O
F -40°C to +150°C
T4 WITH
PRO
CESS TEM
PERATU
RE R
ANG
E OF -40°C
to +135°C T5 W
ITH PR
OC
ESS TEMPER
ATUR
E RAN
GE O
F -40°C to +100°C
T6 WITH
PRO
CESS TEM
PERATU
RE R
ANG
E OF -40°C
to +85°C AM
BIENT TEM
PERATU
RE R
ANG
E -40°C Ta+71°C10. W
HEN
MO
UN
TING
ON
A MAG
NETIC
LEVEL GAU
GE M
AKE SUR
E THE ELEC
TRO
NIC
HEAD
AND
PRESSU
RE
BARR
IER H
AVE A MIN
IMU
M SPAC
ING
OF 5 IN
CH
ES. SEE INSTALLATIO
N M
ANU
AL FOR
DETAIL
11. FLAMEPATH
S ARE N
OT FO
R R
EPAIR
5" [127mm
] Minim
um
Level Plus® CON COMPARTIMIENTOSManual de funcionamiento
I 52 I
Fig. 61: Ignífugo, plano de instalación FM, Modbus y DDA
DETAIL D
SCALE 3
DETAIL E
SCALE 1.60
DETAIL F
SCALE 1.2
D
E
F
11
22
33
44
55
66
77
88
AA
BB
CC
DD
REV
ECO
#D
ESCR
IPTION
TITLE
SIZED
WG
NO
.R
EV
PRO
DU
CT LIN
ESC
ALE:
BYD
ATE
SHEET
OF
UN
LESS OTH
ERW
ISE SPECIFIED
TOLER
ANC
ES0 PLAC
ESM
M1 PLAC
EM
MAN
GLES
0.5
0.1
- THR
EAD
DEPTH
S ARE TO
MIN
. FULL TH
DS
- DR
ILL DEPTH
S ARE TO
FULL D
IA.
- REM
OV
E BU
RR
S AND
SHAR
P E
DG
ES- D
O N
OT SC
ALE PRIN
T- M
ACH
INED
SUR
FACE
FINISH
3.2uM [125 uIn]
PRO
PRIETAR
Y DATA
THE IN
FOR
MATIO
N AN
D D
ESIG
N(S) D
ISCLO
SEDH
ERE
IN AR
E THE PR
OPER
TY OF M
TS SYSTEMS
CO
RPO
RATIO
N AN
D M
AY NO
T BE USED
,R
EPRO
DU
CED
OR
DISC
LOSED
IN A
NY FO
RM
EXCEPT AS G
RAN
TED IN
WR
ITING
BY MTS
SYSTEMS C
OR
POR
ATIO
N. TH
IS RESTR
ICTIO
NEXC
LUD
ES INFO
RM
ATION
THA
T IS IN TH
E PU
BLIC D
OM
AIN O
R W
AS LEGITIM
ATELY IN TH
EPR
IOR
POSSES
SION
OF TH
E REC
IPIENT.
mM
TS SYSTEMS C
OR
POR
ATION
SENSO
RS D
IVISION
3001 SHELD
ON
DR
IVE, CAR
Y, NC
27513
METRIC
FIRST
ANG
LED
651553-3B
LEVEL2
2 D
RAW
N BY:
MS
***NO
REVISIO
NS SH
ALL BE MAD
E WITH
OU
T THE N
OTIFIC
ATION
TO APPR
OVAL AG
ENC
Y(S).***B
MS
10/22/15RELEASE TO PRODUCTION
8482UPDATED W
IRING DWG TO ANALOG
MS
5/17/18A
7957
LOOP 2-
LOOP 2+
EARTH
LOOP 1-
LOOP 1+
NO
TES: 1. TH
E CU
STOM
ER SH
OU
LD C
ON
NEC
T THE O
UTSID
E GR
OU
ND
LUG
TO TH
E SAFETY EARTH
ING
GR
OU
ND
SYSTEM W
ARN
ING
: C
ON
DU
IT SEALS REQ
UIR
ED W
ITHIN
50mm
OF H
OU
SING
.
FIGU
RE 2
DU
AL CAVITY H
OU
SING
LOOP 1+ LOOP 1- EARTH LOOP 2+ LOOP 2-
FIGU
RE 1
SING
LE CAVITY H
OU
SING
LOOP 1+ LOOP 1- EARTH LOOP 2+ LOOP 2-
(ACP) INSTALLATION DWG LP ANALOG
EXPLOSION PROOF ATEX/IEC
Level Plus® CON COMPARTIMIENTOSManual de funcionamiento
I 53 I
11
22
33
44
55
66
77
88
AA
BB
CC
DD
REV
EC
O #
DESC
RIP
TION
TITLE
SIZED
WG
NO
.R
EV
PRO
DU
CT LIN
ESC
ALE:
BYD
ATE
SHEET
OF
UN
LES
S OTH
ER
WISE
SPEC
IFIED
TOLER
ANC
ES0 P
LACE
SM
M1 PLA
CE
MM
AN
GLE
S
0.5
0.1
- THR
EA
D D
EP
THS
AR
E TO
MIN
. FULL TH
DS
- DR
ILL DE
PTH
S A
RE
TO FU
LL DIA
.- R
EM
OV
E B
UR
RS
AN
D S
HA
RP
ED
GE
S- D
O N
OT S
CA
LE P
RIN
T- M
AC
HIN
ED
SU
RFA
CE
FINIS
H 3.2uM
[125 uIn]
PRO
PRIETA
RY D
ATA
THE
INFO
RM
ATIO
N A
ND
DE
SIG
N(S
) DIS
CLO
SE
DH
ER
EIN
AR
E TH
E P
RO
PE
RTY
OF M
TS S
YS
TEM
SC
OR
PO
RA
TION
AN
D M
AY
NO
T BE
US
ED
,R
EP
RO
DU
CE
D O
R D
ISC
LOS
ED
IN A
NY
FOR
ME
XC
EP
T AS
GR
AN
TED
IN W
RITIN
G B
Y M
TSS
YS
TEM
S C
OR
PO
RA
TION
. THIS
RE
STR
ICTIO
NE
XC
LUD
ES
INFO
RM
ATIO
N TH
AT IS
IN TH
E
PU
BLIC
DO
MA
IN O
R W
AS
LEG
ITIMA
TELY
IN TH
EP
RIO
R P
OS
SE
SS
ION
OF TH
E R
EC
IPIE
NT.
mM
TS SYS
TEMS
CO
RP
OR
ATIO
NS
ENSO
RS D
IVISIO
N3001 SH
ELDO
N D
RIVE
, CA
RY, N
C 27513
METRIC
FIRST
ANG
LED
651552-3A
1
2 D
RAW
N BY:
MS
***NO
RE
VISION
S SHALL BE
MA
DE
WITH
OU
T THE
NO
TIFICA
TION
TO A
PPRO
VAL AG
EN
CY(S).***
AM
S10/24/14
RELEASE TO PRO
DU
CTION
EARTH G
ROU
ND
24 VDC
COM
MO
N-
Rx /Tx+
Rx /Tx-
EARTH G
ROU
ND
CATEGO
RY 1
CATEGO
RY 2
NO
N H
AZARDO
US LO
CATION
HAZARD
OU
S LOCATIO
N
AGEN
CY C
ON
TRO
LLED D
RAW
ING
(ATEX/IEC). N
O C
HAN
GES W
ITHO
UT PR
IOR
AGEN
CY APPR
OVAL
EARTH TERM
INAL
(ACP) INSTALLATIN
DW
G LP D
IGITAL
EXPLOSIO
N PRO
OF ATEX/IEC
7957
LEVEL
N/A
1725II 1/2 G
Ex db IIB+
H2 T6...T3 G
a/Gb
Ta = -40°C to +
71°C; IP65
For ATEX - FM16ATEX0068X
For IECEx - IECEx FMG 16.0033X
AREA REQ
UIRIN
GEPL G
b
AREA REQU
IRING
EPL Ga
NO
TES:
1.ALL NA
TION
AL AND
LOC
AL CO
DES AN
D R
EGU
LATION
S MU
ST BE ADH
ERE
D TO
WH
EN
INSTALLIN
G TH
E LEVEL SEN
SOR
IN H
AZARD
OU
S ENVIR
ON
MEN
TS. SEAL ALL C
ON
DU
ITS WITH
IN 50m
m O
F ENC
LOSU
RE.
2.DU
AL-CAV
ITY ENC
LOSU
RES:
CU
STOM
ER C
ON
NEC
TION
S WILL BE
MAD E AT TER
MIN
AL BLOC
K ON
POW
ER SID
E O
F HO
USIN
G (N
OT TO
TERM
INAL BLO
CK O
N IN
TERC
ON
NEC
T BOAR
D). SEE FIG
UR
E 2 ON
PAGE 2
3. CA
UTIO
N: FLEXIBLE G
AUG
ES H
AVE A M
INIM
UM
BEND
RAD
IUS
OF 381m
m(15")
4.WAR
NIN
G: TO
PREV
ENT IG
NITIO
N O
F FLAMM
ABLE OR
CO
MBU
STIBLE ATMO
SPH
ERES,
DISC
ON
NEC
T POW
ER BEFO
RE SE
RVIC
ING
5.W
ARN
ING
: THE EQ
UIPM
ENT C
ON
TAINS N
ON
-METALLIC
ENC
LOS
UR
E AND
PRO
CESS PA
RTS, TO
PREVEN
T TH
E RIS
K OF ELEC
TRO
STATIC
SPARKIN
G. TH
E NO
N-M
ETALLIC SU
RFAC
E AND
PRO
CESS PAR
TS S
HO
ULD
ON
LY BE C
LEAN
ED W
ITH A D
AMP C
LOTH
. PAINTED
SURFACE O
F THE EQ
UIPM
ENT M
AY STORE ELECTR
OSTATIC CH
ARGE
AND
BECOM
E A SOU
RCE OF IG
NITIO
N IN
APPLICATION
S WITH
A LOW
RELATIVE H
UM
IDITY <
~30%
RELATIVE H
UM
IDITY W
HER
E THE PAIN
TED SU
RFACE IS RELATIVELY FR
EE OF SU
RFACE CO
NTAM
INATIO
N SU
CH AS D
IRT, DU
ST OR O
IL. CLEANIN
G O
F T HE PAIN
TED SU
RFACE SHO
ULD
ON
LY BE DO
NE
WITH
A DAM
P CLOTH
.6. C
ABLES SH
ALL BE R
ATED > 5C
ABOVE M
AXIMU
M A
MB
IEN
T TEMPER
ATUR
E. 7. TO
MAIN
TAIN
THE IN
GR
ESS PRO
TEC
TION
RATIN
G O
F IP65, TEFLO
N TAPE
(3 WR
APS) O
R PIPE D
OPE SH
ALL BE U
SED
. REFER
TO IN
STALLATION
INSTR
UC
TION
S.8. TH
E EQU
IPMEN
T CAN
BE IN
STALLED IN
THE BO
UN
DA
RY W
ALL BETWEEN
AN EPL G
a AR
EA AND
THE
LESS HA
ZARD
OU
S AR
EA, EPL G
b. IN TH
IS CO
NFIG
UR
ATION
, THE PR
OC
ESS CO
NN
ECTIO
N IS IN
STALLED
IN EPL G
a, WH
ILE THE TR
ANSM
ITTER H
OU
SING
IS INSTALLED
IN EPL G
b. REFE
R TO
INSTALLATIO
N
INSTR
UC
TION
S. EQ
UIPM
ENT C
AN BE IN
STALLED
IN A BO
UN
DAR
Y WALL C
ON
FIGU
RATIO
N W
HER
E THE PR
OC
ESS CO
NN
ECTIO
N IS IN
STALLED A
S CATEG
OR
Y 1G EQ
UIPM
ENT W
HILE TH
E TRAN
SMITTER
HO
USIN
G IS IN
STALLED
AS C
ATEGO
RY 2G
EQU
IPMEN
T. REFER
TO IN
STALLATION
INSTR
UC
TION
S. 9. TH
E APPLICABLE TE
MP
ERATU
RE C
LASS OF TH
E EQU
IPMEN
T, AMBIEN
T TEM
PER
ATUR
E RAN
GE,
AND
MAXIM
UM
PRO
CESS TEM
PER
ATUR
E OF TH
E EQU
IPMEN
T IS AS FOLLO
WS;
T3 WITH
PRO
CESS TEM
PERATU
RE R
ANG
E OF -40°C
to +150°C T4 W
ITH PR
OC
ESS TEMPER
ATUR
E RAN
GE O
F -40°C to +135°C
T5 WITH
PRO
CESS TEM
PERATU
RE R
ANG
E OF -40°C
to +100°C T6 W
ITH PR
OC
ESS TEMPER
ATUR
E RAN
GE O
F -40°C to +85°C
AMBIEN
T TEMPER
ATUR
E RAN
GE -40°CTa+71°C
10. WH
EN M
OU
NTIN
G O
N A
MAG
NETIC
LEVEL G
AUG
E MAKE SU
RE
THE ELEC
TRO
NIC
HEAD
AN
D PR
ESSUR
E BAR
RIER
HA
VE A MIN
IMU
M SP
ACIN
G O
F 5 INC
HE
S. SEE INSTALLATIO
N M
ANU
AL FOR
DE
TAIL11. FLAM
EPATHS
ARE N
OT FO
R R
EPAIR
SEE NO
TE 8
CON
DU
IT SEALCON
DU
IT
SEE NO
TE 1
5" [127mm
] Minim
um
Fig. 62: Ignífugo, plano de instalación ATEX/IECEx, HART®, página 1
Level Plus® CON COMPARTIMIENTOSManual de funcionamiento
I 54 I
DETAIL A
SCALE 1.60 : 1
DETAIL C
SCALE 3 : 1
DETAIL D
SCALE 1.2
A
C
D
11
22
33
44
55
66
77
88
AA
BB
CC
DD
REV
ECO
#D
ESCR
IPTION
TITLE
SIZED
WG
NO
.R
EV
PRO
DU
CT LIN
ESC
ALE:
BYD
ATE
SHEET
OF
UN
LESS OTH
ERW
ISE SPECIFIED
TOLER
ANC
ES0 PLAC
ESM
M1 PLAC
EM
MAN
GLES
0.5
0.1
- THR
EAD D
EPTHS AR
E TO M
IN. FU
LL THD
S- D
RILL D
EPTHS AR
E TO FU
LL DIA.
- REM
OVE BU
RR
S AND
SHAR
P EDG
ES- D
O N
OT SC
ALE PRIN
T- M
ACH
INED
SUR
FACE FIN
ISH 3.2uM
[125 uIn]
PRO
PRIETAR
Y DATA
THE IN
FOR
MATIO
N AN
D D
ESIGN
(S) DISC
LOSED
HER
EIN AR
E THE PR
OPER
TY OF M
TS SYSTEMS
CO
RPO
RA TIO
N AN
D M
AY NO
T BE USED
,R
EPRO
DU
CED
OR
DISC
LOSED
IN AN
Y FOR
MEXC
EPT AS GR
ANTED
IN W
RITIN
G BY M
TSSYSTEM
S CO
RPO
RATIO
N. TH
IS RESTR
ICTIO
NEXC
LUD
ES INFO
RM
ATION
THAT IS IN
THE
PUBLIC
DO
MAIN
OR
WAS LEG
ITIMATELY IN
THE
PRIO
R PO
SSESSION
OF TH
E REC
IPIENT.
mM
TS SYSTEMS C
OR
POR
ATION
SENSO
RS D
IVISION
3001 SHELD
ON
DR
IVE, CAR
Y, NC
27513
METRIC
FIRST
ANG
LED
651552-3A
2
2 D
RAW
N BY:
MS
***NO
REVISIO
NS SH
ALL BE MAD
E WITH
OU
T THE N
OTIFIC
ATION
TO APPR
OVAL AG
ENC
Y(S).***A
MS
10/24/14RELEASE TO
PROD
UCTIO
N
+24V GNDEARTHTX/RX+TX/RX-
GND
+24V
TX/RX-
TX/RX+
EARTH
FIGU
RE 1
SING
LE CAVITY H
OU
SING
FIGU
RE 2
DU
AL CAVITY H
OU
SING
NO
TES: 1. TH
E CU
STOM
ER SH
OU
LD C
ON
NEC
T THE O
UTSID
E GR
OU
ND
LUG
TO TH
E SAFETY EARTH
ING
GR
OU
ND
SYSTEM W
ARN
ING
: C
ON
DU
IT SEALS REQ
UIR
ED W
ITHIN
50mm
OF H
OU
SING
.
+24V GND EARTH Tx/Rx+ Tx/Rx-
7957
(ACP) INSTALLATIO
N D
WG
LP DIG
ITAL EXPLO
SION
PROO
F ATEX/IEC
Fig. 63: Ignífugo, plano de instalación ATEX/IECEx, HART®, página 2
Level Plus® CON COMPARTIMIENTOSManual de funcionamiento
I 55 I
13.5.3 Declaración de conformidad de la CE
Level Plus® CON COMPARTIMIENTOSManual de funcionamiento
I 56 I
UNITED STATESMTS Systems Corporation
Sensors Division
3001 Sheldon DriveCary, N.C. 27513Phone: +1 919 677-0100E-mail: [email protected]
GERMANYMTS Sensor Technologie
GmbH & Co. KG
Auf dem Schüffel 958513 LüdenscheidPhone: +49 2351 9587-0E-mail: [email protected]
ITALYBranch Offi ce
Phone: +39 030 988 3819E-mail: [email protected]
FRANCEBranch Offi ce
Phone: +33 1 58 4390-28E-mail: [email protected]
GREAT BRITAIN Branch Offi ce
Phone: +44 79 44 15 03 00E-mail: [email protected]
CHINABranch Offi ce
Phone: +86 21 6485 5800 E-mail: [email protected]
JAPANBranch Offi ce
Phone: +81 3 6416 1063E-mail: [email protected]
www.mtssensors.comMTS, Temposonics and Level Plus are registered trademarks of MTS Systems Corporation in the United States; MTS SENSORS and the MTS SENSORS logo are trademarks of MTS Systems Corporation within the United States. These trademarks may be protected in other countries. All other trademarks are the property of their respective owners. Copyright © 2018 MTS Systems Corporation. No license of any intellectual property rights is granted. MTS reserves the right to change the information within this document, change product designs, or withdraw products from availability for purchase without notice. Typographic and graphics errors or omissions are unintentional and subject to correction. Visit www.mtssensors.com for the latest product information.
Número de pieza del documento: 551696 Revisión E (ES) 12/2018
S a f e t y I n t e g r i t y L e v e lIEC 61508