BB
'
CC
'
2.90
2.82
2.82
1.20
1.38
1.90
10.00
1.64
1.00
2.00
.80
1.30
2.82
5.10
.80
.80
1.20
2.80
1.20
1.20
6.00
A
12
3
A B B'
C D FE
A'
Arq. Rudyard Javier Luengas ContrerasM.P. 25700-58438 CND
UNIDAD DE GESTION VISR
Nombre:__________________Cargo:_______________________
ZONA SÍSMICA ALTAAa= 0.25, Av= 0.25
Clima Frío > 2000 m.s.n.m
PROTOTIPO (2) VIVIENDA NUEVARESGUARDO PASTAS ALDANA -MUNICIPIO DE ALDANA - NARIÑO
VIVIENDA NUEVA
PLANTA ARQUITECTÓNICA
(ÁREA 55.2m2)
1/35 15/08/2017
ORIGINAL FIRMADO POR PROFESIONAL
FACHADA PRINCIPAL
1 2 3
CANTIDADES ARQUITECTONICAS
DESCRIPCION
PUERTAS HABITACIONES (2.10 x 0.80 M)
CANT
3 UN
PUERTA ACCESO PPAL (2.10 x 0.90 M)2 UN
VENTANAS (1.20 x 1.20 M)4 UN
DUCHA1 UN
SANITARIO
LAVAMANOS
LAVADERO
1 UN
1 UN
1 UN
1 UN
1 UN
MESON DE COCINA
ESTUFA
PUERTA BAÑO Y DEPOSITO (2.10 x 0.70 M)2 UN
UNIDAD DE GESTION VISR
Nombre:__________________Cargo:_______________________
FACHADA PRINCIPAL
2/35 15/08/2017
ZONA SÍSMICA ALTAAa= 0.25, Av= 0.25
Clima Frío > 2000 m.s.n.m
PROTOTIPO (2) VIVIENDA NUEVARESGUARDO PASTAS ALDANA -MUNICIPIO DE ALDANA - NARIÑO
VIVIENDA NUEVA
Arq. Rudyard Javier Luengas ContrerasM.P. 25700-58438 CND
ORIGINAL FIRMADO POR PROFESIONAL
12 3
FACHADA POSTERIOR
UNIDAD DE GESTION VISR
Nombre:__________________Cargo:_______________________
VIVIENDA NUEVA
FACHADA POSTERIOR
3/35 15/08/2017
ZONA SÍSMICA ALTAAa= 0.25, Av= 0.25
Clima Frío > 2000 m.s.n.m
PROTOTIPO (2) VIVIENDA NUEVARESGUARDO PASTAS ALDANA -MUNICIPIO DE ALDANA - NARIÑO
Arq. Rudyard Javier Luengas ContrerasM.P. 25700-58438 CND
ORIGINAL FIRMADO POR PROFESIONAL
CORTE A - A'
1.1
01
.0
0.2
0
1.1
01
.0
0.2
0
2.1
0
3.3
0
3.4
4
2.3
01
.0
0.1
4
2.90.12 .90 1.38 1.30 2.80
2.1
0.7
4
2.1
0.9
5
.9
0
A B B' C D FE
UNIDAD DE GESTION VISR
Nombre:__________________Cargo:_______________________
VIVIENDA NUEVA
CORTE A-A'
4/35 15/08/2017
ZONA SÍSMICA ALTAAa= 0.25, Av= 0.25
Clima Frío > 2000 m.s.n.m
PROTOTIPO (2) VIVIENDA NUEVARESGUARDO PASTAS ALDANA -MUNICIPIO DE ALDANA - NARIÑO
Arq. Rudyard Javier Luengas ContrerasM.P. 25700-58438 CND
ORIGINAL FIRMADO POR PROFESIONAL
1 2 3
CORTE B - B'
3.07
.37
3.44
2.10
2.02 .80 .80 1.90
2.10
.97
UNIDAD DE GESTION VISR
Nombre:__________________Cargo:_______________________
VIVIENDA NUEVA
CORTE B-B'
5/35 15/08/2017
ZONA SÍSMICA ALTAAa= 0.25, Av= 0.25
Clima Frío > 2000 m.s.n.m
PROTOTIPO (2) VIVIENDA NUEVARESGUARDO PASTAS ALDANA -MUNICIPIO DE ALDANA - NARIÑO
Arq. Rudyard Javier Luengas ContrerasM.P. 25700-58438 CND
ORIGINAL FIRMADO POR PROFESIONAL
12
3
CORTE C - C'
2.97
.47
3.44
2.10
.87
1.50 .70 .62 .90 1.92
UNIDAD DE GESTION VISR
Nombre:__________________Cargo:_______________________
VIVIENDA NUEVA
CORTE C - C'
6/35 15/08/2017
ZONA SÍSMICA ALTAAa= 0.25, Av= 0.25
Clima Frío > 2000 m.s.n.m
PROTOTIPO (2) VIVIENDA NUEVARESGUARDO PASTAS ALDANA -MUNICIPIO DE ALDANA - NARIÑO
Arq. Rudyard Javier Luengas ContrerasM.P. 25700-58438 CND
ORIGINAL FIRMADO POR PROFESIONAL
10.002.00
6.00
PLANTA DE CUBIERTA
12
3
A B B'
C D FE
UNIDAD DE GESTION VISR
Nombre:__________________Cargo:_______________________
VIVIENDA NUEVA
PLANTA DE CUBIERTA
7/35 15/08/2017
ZONA SÍSMICA ALTAAa= 0.25, Av= 0.25
Clima Frío > 2000 m.s.n.m
PROTOTIPO (2) VIVIENDA NUEVARESGUARDO PASTAS ALDANA -MUNICIPIO DE ALDANA - NARIÑO
Arq. Rudyard Javier Luengas ContrerasM.P. 25700-58438 CND
ORIGINAL FIRMADO POR PROFESIONAL
1
2
3
A B C D FE
1'
2'
A B C D FE
1
2
3
2'
3.02 1.42 1.28
2.1
0.85
0.22
3.02 1.42 1.28 1.64
Malla ElectrosoldadaTipo M-131
Malla ElectrosoldadaTipo M-131
Malla ElectrosoldadaTipo M-131
Malla ElectrosoldadaTipo M-131
Malla ElectrosoldadaTipo M-131
Malla ElectrosoldadaTipo M-131
CC_T1
CC_T1
CC_T1
CC_T1
CC_T1 CC_T1
CC_T1
CC_T2
CC_T2
CC_T2
CC_T2
CC_T2
CC_T3
CC_T3
CC_T3 CC_T4
CC_T4
CC_T4
CC_T5
V.CIM 1 (0.30 X 0.30) V.CIM 1 (0.30 X 0.30) V.CIM 1 (0.30 X 0.30)
V.CIM 2 (0.30 X 0.30) V.CIM 2 (0.30 X 0.30) V.CIM 2 (0.30 X 0.30)
V.CIM 3(0.30 X 0.30) V.CIM 3(0.30 X 0.30) V.CIM 3(0.30 X 0.30)
V.CI
M A
(0.30
X 0.
30)
V.CI
M A
(0.30
X 0.
30)
V.CI
M B
(0.30
X 0.
30)
V.CI
M B
(0.30
X 0.
30)
V.CI
M C
(0.30
X 0.
30)
V.CI
M C
(0.30
X 0.
30)
V.CI
M B'
(0.25
X 0.
25) V.
CIM
D (0
.30 X
0.30
)
V.CI
M E
(0.30
X 0.
30)
V.CI
M F
(0.30
X 0.
30)
V.CIM 2''' (0.30 X 0.30)V.CIM 2'' (0.25 X 0.25)
2.55
2.55
2.63
2.22
0.75 1.23
2.22
1.12
1.23
1.02
0.65
1.66
2.55
2.62
2.4
0.22
0.73
2.94
2
1.64
2'' 2''
B'
B'
1.02 1.5
1.02 1.5
1.62
2'''
0.38
CC_T3
CC_T4
PLANTA ESTRUCTURAL DE CIMENTACIÓNESC: 1_50
UNIDAD DE GESTION VISR
Nombre:__________________Cargo:_______________________
VIVIENDA NUEVA
PLANTA ESTRUCTURAL DE
CIMENTACIÓN
8/35 15/08/2017
ZONA SÍSMICA ALTAAa= 0.25, Av= 0.25
Clima Frío > 2000 m.s.n.m
PROTOTIPO (2) VIVIENDA NUEVARESGUARDO PASTAS ALDANA -MUNICIPIO DE ALDANA - NARIÑO
Ing. Amaury Andrés Urueta MoraM.P.222-02212829 COR.
ORIGINAL FIRMADO POR PROFESIONAL
A B
3.02
2#5 Lc= 4.4m
2#5 Lc= 5.0m
VIGA CIMIENTO 1 (0.30 x 0.30)
20 # 3@ 0.15
17 # 3@ 0.15
C E
2.52 2.7
17 # 3@ 0.15
2#5 Lc= 4.75m
2#5 Lc= 5.35m
A B
3.02
2#5 Lc= 4.45m
2#5 Lc= 5.4m
VIGA CIMIENTO 2, 3 (0.30 x 0.30)
20 # 3@ 0.15
17 # 3@ 0.15
C E
2.52 1.42
9 # 3@ 0.15
2#5 Lc= 6.0m
2#5 Lc= 4.45m
D
2.92
19 # 3@ 0.15
2#5 Lc= 3.70m
1
2.1
2#5 Lc= 5.0m
2#5 Lc= 1.7m
VIGA CIMIENTO A, B , C (0.30 x 0.30)
13 # 3@ 0.15
14 # 3@ 0.15
0.85 0.73
2#5 Lc= 5.55m
2#5 Lc= 2.3m
1' 2 2' 3
2.2
4 # 3@ 0.15
5 # 3@ 0.15
VIGA CIMIENTO D, F (0.30 x 0.30)
13 # 3@ 0.15
0.16 0.94
2#5 Lc= 3.55m
2#5 Lc= 3.55m
2 2'' 3
1.99
6 # 3@ 0.15
VIGA CIMIENTO E (0.30 x 0.30)
19 # 3@ 0.15
2#5 Lc= 3.55m
2#5 Lc= 3.55m
1 2
2.94
VIGA CIMIENTO 2''' (0.30 x 0.30)
9 # 3@ 0.15
2#5 Lc= 3.2m
2#5 Lc= 3.2m
B C
1.5
B'
1.02
7 # 3@ 0.15
VIGA CIMIENTO 2'' (0.25 x 0.25)
9 # 3@ 0.15
2#4 Lc= 2.0m
2#4 Lc= 2.0m
D
1.42
C
VIGA CIMIENTO B' (0.25 x 0.25)
8 # 3@ 0.15
2#4 Lc= 1.9m
2#4 Lc= 1.9m
D
1.32
C
0.30
0.30
0.15
0.150.08
#2 Lc= 0.76mRec: 7.5 cm
0.30
0.30
0.15
0.150.08
#2 Lc= 0.76mRec: 7.5 cm
0.30
0.30
0.15
0.150.08
#2 Lc= 0.76mRec: 7.5 cm
0.30
0.30
0.15
0.150.08
#2 Lc= 0.76mRec: 7.5 cm
0.25
0.25
0.10
0.100.08
#2 Lc= 0.56mRec: 7.5 cm
DESPIECE DE VIGAS DE CIMENTACIÓNESC: 1:50
UNIDAD DE GESTION VISR
Nombre:__________________Cargo:_______________________
VIVIENDA NUEVA
DESPIECE DE VIGAS DE
CIMENTACIÓN
9/35 15/08/2017
ZONA SÍSMICA ALTAAa= 0.25, Av= 0.25
Clima Frío > 2000 m.s.n.m
PROTOTIPO (2) VIVIENDA NUEVARESGUARDO PASTAS ALDANA -MUNICIPIO DE ALDANA - NARIÑO
Ing. Amaury Andrés Urueta MoraM.P.222-02212829 COR.
ORIGINAL FIRMADO POR PROFESIONAL
ELEMENTO CANT.(Un)
ELEMENTO CANT.(Un)
#BARRA #BARRA SUBTOTAL(kg)NOMBRE
VC-1 #5Lc= 4.4m 2 #3 54 36.8 Lc= 0.76m
VC-1 #5Lc= 5.0m 2 15.6
VC-1 #5Lc= 5.35m 2 16.7
VC-1 #5Lc= 4.75m 2 14.8
VC-2,3 #5Lc= 4.45m 4 55.6
VC-2,3 #5Lc= 5.4m 2 16.9
VC-2,3 #5Lc= 6.0m 2 18.8
VC-2,3 #5Lc= 3.7m 2 11.6
VC-A,B,C #5Lc= 5.0m 2 #3 36 31 Lc= 0.76m
ELEMENTO CANT.(Un)
ELEMENTO CANT.(Un)
#BARRA #BARRA SUBTOTAL(kg)NOMBRE
VC-E #5Lc= 4.25m 4 #3 19 34.7 Lc= 0.76m
VC-2''' #5Lc= 2.45m 4 22.2
VC-2'' #4Lc= 2.0m 4 #3 9 11.9 Lc= 0.76m
VC-B' #4Lc= 1.9m 4 #3 8 11.5 Lc= 0.76m
#3 65 Lc= 0.76m
#3 16 Lc= 0.76m
#5Lc= 2.3m 2 7.2
#5Lc= 1.7m 2 5.3
#5Lc= 5.55m 2 17.3
VC-D,F #5Lc= 3.55m 4 #3 19 30.3 Lc= 0.76m
VC-A,B,C
VC-A,B,C
VC-A,B,C
UNIDAD DE GESTION VISR
Nombre:__________________Cargo:_______________________
VIVIENDA NUEVA
CUADRO DE ACEROS
VIGAS DE CIMENTACIÓN
10/35 15/08/2017
ZONA SÍSMICA ALTAAa= 0.25, Av= 0.25
Clima Frío > 2000 m.s.n.m
PROTOTIPO (2) VIVIENDA NUEVARESGUARDO PASTAS ALDANA -MUNICIPIO DE ALDANA - NARIÑO
Ing. Amaury Andrés Urueta MoraM.P.222-02212829 COR.
ORIGINAL FIRMADO POR PROFESIONAL
1
2
3
A B B' C D FE
1'
2'
A B B' C D FE
1
2
3
2'
3.02 1.02 1.5 1.42 1.28
2.1
0.85
0.73
2.94
3.02 1.02 1.5 1.42 1.28 1.64
CC_T1
2.55
2.55
2.63
2.22
0.75 1.23
2.22
1.12
1.26
1.05
0.65
1.66
2.55
2.62
2.4
CC_T1
CC_T1
CC_T1
CC_T1
CC_T1
CC_T1
CC_T2
CC_T2
CC_T2
CC_T2
CC_T2
CC_T3
CC_T3
CC_T3 CC_T4
CC_T4
CC_T4
CC_T5
0.220.22
2
2'' 2''
1.62
2'''
0.38
CC_T3
CC_T4
PLANTA ESTRUCTURAL DE CIMENTACIÓN Y MUROSESC: 1_50
UNIDAD DE GESTION VISR
Nombre:__________________Cargo:_______________________
VIVIENDA NUEVA
PLANTA DE MUROS SOBRE
VIGAS DE CIMENTACIÓN
11/35 15/08/2017
ZONA SÍSMICA ALTAAa= 0.25, Av= 0.25
Clima Frío > 2000 m.s.n.m
PROTOTIPO (2) VIVIENDA NUEVARESGUARDO PASTAS ALDANA -MUNICIPIO DE ALDANA - NARIÑO
Ing. Amaury Andrés Urueta MoraM.P.222-02212829 COR.
ORIGINAL FIRMADO POR PROFESIONAL
1
2
3
A B B' C D FE
1'
2'
A B B' C D FE
1
2
3
2'
3.02 1.02 1.5 1.42 1.28
2.1
0.85
0.73
2.94
3.02 1.02 1.5 1.42 1.28 1.64
CC_T1
CC_T1
CC_T1
CC_T1
CC_T1
CC_T1
CC_T1
CC_T2
CC_T2
CC_T2
CC_T2
CC_T2
CC_T3
CC_T3
CC_T3 CC_T4
CC_T4
CC_T4
CC_T5
1.62
0.220.22
2
2'' 2''
2'''
0.38
CC_T3
CC_T4
PLANTA ESTRUCTURAL DE MUROS CONFINADOSESC: 1_50
UNIDAD DE GESTION VISR
Nombre:__________________Cargo:_______________________
VIVIENDA NUEVA
PLANTA ESTRUCTURAL DE
MUROS CONFINADOS
12/35 15/08/2017
ZONA SÍSMICA ALTAAa= 0.25, Av= 0.25
Clima Frío > 2000 m.s.n.m
PROTOTIPO (2) VIVIENDA NUEVARESGUARDO PASTAS ALDANA -MUNICIPIO DE ALDANA - NARIÑO
Ing. Amaury Andrés Urueta MoraM.P.222-02212829 COR.
ORIGINAL FIRMADO POR PROFESIONAL
1
2
3
A B B' C D FE
1'
2'
A B B' C D FE
1
2
3
2'
3.02 1.02 1.5 1.42 1.28
2.1
0.85
0.73
2.94
3.02 1.02 1.5 1.42 1.28 1.64
CC_T10.03
0.03
0.02
0.220.22
0.03 0.02
0.030.03 0.02
0.020.07
0.030.03
0.1
0.87
1.62
0.02
0.75
0.5
1.02
0.2
0.6
0.6
0.6
0.05
0.85
CC_T1
CC_T1
CC_T1
CC_T1
CC_T1
CC_T1
CC_T2
CC_T2
CC_T2
CC_T2
CC_T2
CC_T3
CC_T3
CC_T3 CC_T4
CC_T4
CC_T4
CC_T5
0.220.22
2
2'' 2''
1.62
2'''
0.38
0.02
CC_T3
CC_T4
PLANTA ESTRUCTURAL DE COLUMNAS DE CONFINAMIENTOESC: 1_50
1.02
CONCRETO PARA SOLADO= 1500 PSICONCRETO PARA VIGA DE CIMENTACIÓN= 2500 PSICONCRETO PARA CONTRAPISO= 2500 PSICONCRETO PARA COLUMNA DE CONFINAMIENTO= 2500 PSICONCRETO PARA VIGA DE CONFINAMIENTO= 2500 PSICONCRETO PARA VIGA CINTA= 2500 PSI
NOTAS:1. EL DESPLANTE DE LA VIGA CIMENTACIÓN SERÁ DE 0.30 m2. ACERO DE REFUERZO #2= 240 MPa3. ACERO DE REFUERZO #3= 420 MPa4. EL ACERO DE REFUERZO DEBERÁ ESTAR LIBRE DE IMPUREZAS Y CORROSIÓN.5. SE DEBERÁ REALIZAR PRIMERO EL LEVANTE DE LA MAMPOSTERÍA Y LUEGO SE
FUNDEN LAS COLUMNAS Y VIGAS DE CONFINAMIENTO.6. EL TRASLAPO PARA LA BARRA #3 DEBERÁ SER MÍNIMO DE 0.5 m, PARA LA BARRA #4 DE
0.7 m Y PARA LA BARRA #5 DE 0.9m.7. EL GANCHO ESTÁNDAR MÍNIMO PARA LA BARRA # 3 SERÁ DE 0.15m, PARA LA BARRA #4
DE 0.20m Y PARA LA BARRA #5 DE 0.25m.8. EL NIVEL SUPERIOR DEL CONTRAPISO COINCIDIRÁ CON EL NIVEL SUPERIOR DE LA
VIGA DE CIMENTACIÓN.9. LA RESISTENCIA MÍNIMA A LA COMPRESIÓN DE LA UNIDAD DE MAMPOSTERÍA EN
ARCILLA PERFORACIÓN HORIZONTAL #5 = 5 MPa10. TAMAÑO MÁXIMO DEL AGREGADO SERÁ DE 34"11. LOS CUADROS DE ACEROS SON ILUSTRATIVOS. EL CONSTRUCTOR DEBERÁ ELABORAR
SUS PROPIOS CUADROS DE ACEROS PARA LAS RESPECTIVAS COMPRAS Y ARMADOSEN OBRA.
CC_T6
CC_T6
CC_T6
CC_T6
CC_T6
CC_T6
CC_T6
CC_T6
CC_T6
UNIDAD DE GESTION VISR
Nombre:__________________Cargo:_______________________
VIVIENDA NUEVA
PLANTA ESTRUCTURAL DE
COLUMNAS DE
CONFINAMIENTO
13/35 15/08/2017
ZONA SÍSMICA ALTAAa= 0.25, Av= 0.25
Clima Frío > 2000 m.s.n.m
PROTOTIPO (2) VIVIENDA NUEVARESGUARDO PASTAS ALDANA -MUNICIPIO DE ALDANA - NARIÑO
Ing. Amaury Andrés Urueta MoraM.P.222-02212829 COR.
ORIGINAL FIRMADO POR PROFESIONAL
1
2
3
A B B' C D FE
1'
2'
A B B' C D FE
1
2
3
2'
3.02 1.02 1.5 1.42 1.28
2.1
0.85
0.73
2.94
3.02 1.02 1.5 1.42 1.28 1.64
0.03
0.02
VIGA 3 (0.12 X 0.17) VIGA 3 (0.12 X 0.17) VIGA 3 (0.12 X 0.17)
VIGA 2 (0.12 X 0.17) VIGA 2 (0.12 X 0.17) VIGA 2 (0.12 X 0.17)
VIGA 1 (0.12 X 0.17) VIGA 1 (0.12 X 0.17) VIGA 1 (0.12 X 0.17)
VIGA
A (0
.12 X
0.17
)VI
GA A
(0.12
X 0.
17)
VIGA
B (0
.12 X
0.17
)VI
GA B
(0.12
X 0.
17)
VIGA
E (0
.12 X
0.17
)
VIGA
C (0
.12 X
0.17
)
VIGA
D (0
.12 X
0.17
)
VIGA
F (0
.12 X
0.17
)
VIGA
B' (0
.12 X
0.17
)
VIGA 2''' (0.12 X 0.17)
VIGA 2'' (0.12 X 0.17)
CC_T1
CC_T1
CC_T1
CC_T1
CC_T1
CC_T1
CC_T1
CC_T2
CC_T2
CC_T2
CC_T2
CC_T2
CC_T3
CC_T3
CC_T3 CC_T4
CC_T4
CC_T4
CC_T51.64
0.220.22
2
2'' 2''
1.62
2'''
0.38
CC_T3
CC_T4
PLANTA ESTRUCTURAL DE VIGAS DE CONFINAMIENTOESC: 1_50
UNIDAD DE GESTION VISR
Nombre:__________________Cargo:_______________________
VIVIENDA NUEVA
PLANTA ESTRUCTURAL DE VIGAS DECONFINAMIENTO
14/35 15/08/2017
ZONA SÍSMICA ALTAAa= 0.25, Av= 0.25
Clima Frío > 2000 m.s.n.m
PROTOTIPO (2) VIVIENDA NUEVARESGUARDO PASTAS ALDANA -MUNICIPIO DE ALDANA - NARIÑO
Ing. Amaury Andrés Urueta MoraM.P.222-02212829 COR.
ORIGINAL FIRMADO POR PROFESIONAL
A B
3.02
2#3 Lc= 4.6m
2#3 Lc= 3.8m
VIGA 1 (0.12 x 0.17)
29 # 2@ 0.10
24 # 2@ 0.10
C E
2.52 2.7
24 # 2@ 0.10
2#3 Lc= 5.25m
2#3 Lc= 4.45m
A B
3.02
2#3 Lc= 4.6m
2#3 Lc= 3.95m
VIGA 2, 3 (0.12 x 0.17)
28 # 2@ 0.10
24 # 2@ 0.10
C E
2.52 1.42
13 # 2@ 0.10
2#3 Lc= 2.9m
2#3 Lc= 3.95m
D
2.92
27 # 2@ 0.10
2#3 Lc= 2.75m
1
2.1
2#3 Lc= 4.5m
2#3 Lc= 1.7m
VIGA A, B (0.12 x 0.17)
19 # 2@ 0.10
20 # 2@ 0.10
0.85 0.73
2#3 Lc= 5.35m
2#3 Lc= 2.3m
1' 2 2' 3
2.2
6 # 2@ 0.10
7 # 2@ 0.10
VIGA C, D, F (0.12 x 0.17)
18 # 2@ 0.10
0.94
2#3 Lc= 3.25m
2#3 Lc= 3.25m
2 2'' 3
1.99
8 # 2@ 0.10
VIGA E (0.12 x 0.17)
28 # 2@ 0.10
2#3 Lc= 3.25m
2#3 Lc= 3.25m
1 2
2.94
VIGA 2''' (0.12 x 0.17)
13 # 2@ 0.10
2#3 Lc= 2.85m
2#3 Lc= 2.85m
B C
1.5
B'
1.02
9 # 2@ 0.10
VIGA 2'' (0.12 x 0.17)
13 # 2@ 0.10
2#3 Lc= 1.75m
2#3 Lc= 1.75m
D
1.42
C
VIGA B' (0.12 x 0.17)
12 # 2@ 0.10
2#3 Lc= 1.65m
2#3 Lc= 1.65m
D
1.32
C
2#3 Lc= 4.4m
0.12
0.17
0.06
0.110.05
#2 Lc= 0.45mRec: 3.0 cm
0.12
0.17
0.06
0.110.05
#2 Lc= 0.45mRec: 3.0 cm
0.12
0.17
0.06
0.110.05
#2 Lc= 0.45mRec: 3.0 cm
0.12
0.17
0.06
0.110.05
#2 Lc= 0.45mRec: 3.0 cm
DESPIECE DE VIGAS DE CONFINAMIENTOESC: 1:50
UNIDAD DE GESTION VISR
Nombre:__________________Cargo:_______________________
VIVIENDA NUEVA
DESPIECE DE VIGAS DECONFINAMIENTO
15/35 15/08/2017
ZONA SÍSMICA ALTAAa= 0.25, Av= 0.25
Clima Frío > 2000 m.s.n.m
PROTOTIPO (2) VIVIENDA NUEVARESGUARDO PASTAS ALDANA -MUNICIPIO DE ALDANA - NARIÑO
Ing. Amaury Andrés Urueta MoraM.P.222-02212829 COR.
ORIGINAL FIRMADO POR PROFESIONAL
ELEMENTO CANT.(Un)
ELEMENTO CANT.(Un)
#BARRA #BARRA SUBTOTAL(kg)NOMBRE
VG-1 #3Lc= 4.6m 2 #2 77 13.8
VG-1 #3Lc= 4.45m 2 5.0
Lc= 0.45m
VG-1 #3Lc= 3.8m 2 4.3
VG-1 #3Lc= 5.25m 2 5.9
VG-2,3 #3Lc= 4.6m 2 #2 92 15.5
VG-2,3 #3Lc= 3.95m 4 8.9
Lc= 0.45m
VG-2,3 #3Lc= 2.9m 2 3.3
VG-2,3 #3Lc= 2.75m 2 3.1
VG-C,D,F #3Lc= 3.25m 4 #2 26 10.2 Lc= 0.45m
VG-E #3Lc= 3.25m 4 #2 28 10.5
VG-2''' #3Lc= 2.85m 4 #2 22 8.9
Lc= 0.45m
Lc= 0.45m
VG-2' #3Lc= 1.75m 4 5.4
VG-B' #3Lc= 1.65m 4 5.1
ELEMENTO CANT.(Un)
ELEMENTO CANT.(Un)
#BARRA #BARRA SUBTOTAL(kg)NOMBRE
#2 13 Lc= 0.45m
#2 12 Lc= 0.45m
VG-A,B #4Lc= 4.5m 2 10.9
VG-A,B #3Lc= 2.3m 2
#2 52
2.6
VG-A,B #3Lc= 1.7m 2 1.9
Lc= 0.45m
VG-A,B #3Lc= 5.35m 2 6.0
VG-2,3 #3Lc= 4.4m 2 5.0
UNIDAD DE GESTION VISR
Nombre:__________________Cargo:_______________________
VIVIENDA NUEVA
CUADRO DE ACEROS VIGAS DECONFINAMIENTO
16/35 15/08/2017
ZONA SÍSMICA ALTAAa= 0.25, Av= 0.25
Clima Frío > 2000 m.s.n.m
PROTOTIPO (2) VIVIENDA NUEVARESGUARDO PASTAS ALDANA -MUNICIPIO DE ALDANA - NARIÑO
Ing. Amaury Andrés Urueta MoraM.P.222-02212829 COR.
ORIGINAL FIRMADO POR PROFESIONAL
V. CIMENTACIÓN
DETALLE COLUMNA CONF. TIPO 1(A1, A1', A2, A2', A3, F2, F3)
ESC: 1_50
SOLADO E= 5cm0.3
4#3
Lc=
2.90m
2.47
0.2
0.12
0.17
0.06
0.110.05
#2 Lc= 0.45mRec: 3.0 cm
0.3
31 E #[email protected]
4#3
Lc=
3.45m
3.03
0.2
0.12
0.17
0.06
0.110.05
#2 Lc= 0.45mRec: 3.0 cm
V. CONFINAMIENTO
2.32.13
0.17
0.57
V. CONFINAMIENTO
DETALLE COLUMNA CONF. TIPO 2(B1, B1', B2, B2', B3)ESC: 1_50
2.13
Malla TipoM131
0.06
V. CIMENTACIÓNSOLADO E= 5cm
Malla TipoM131
0.06
25 E #[email protected]
0.3
35 E #[email protected]#
3 Lc
= 3.9
0m
3.46
0.2
0.12
0.17
0.06
0.110.05
#2 Lc= 0.45mRec: 3.0 cm
V. CONFINAMIENTO
2.13
0.17
1
DETALLE COLUMNA CONF. TIPO 3(C1, C2, C2''', C3)
ESC: 1_50
V. CIMENTACIÓNSOLADO E= 5cm
Malla TipoM131
0.06
0.3
32 E #[email protected]
4#3
Lc=
3.60m
3.16
0.2
0.12
0.17
0.06
0.110.05
#2 Lc= 0.45mRec: 3.0 cm
V. CONFINAMIENTO
2.13
0.17
0.7
DETALLE COLUMNA CONF. TIPO 4(D2, D2', D3, B'2''')
ESC: 1_50
V. CIMENTACIÓNSOLADO E= 5cm
Malla TipoM131
0.06
0.3
29 E #[email protected]
4#3
Lc=
3.3m
2.86
0.2
0.12
0.17
0.06
0.110.05
#2 Lc= 0.45mRec: 3.0 cm
V. CONFINAMIENTO
2.13
0.17
0.4
DETALLE COLUMNA CONF. TIPO 5(E1)
ESC: 1_50
V. CIMENTACIÓNSOLADO E= 5cm
Malla TipoM131
0.06
V. CIMENTACIÓN
DETALLE COLUMNA CONF. TIPO 6(AQUELLAS DE SECCIÓN 12 X 12)
ESC: 1_50
SOLADO E= 5cm0.3
4#3
Lc=
2.90m
2.47
0.2
0.12
0.12
0.06
0.06
#2 Lc= 0.30mRec: 3.0 cm
2.3
V. CONFINAMIENTO
2.13
Malla TipoM131
0.06
25 E #[email protected]
UNIDAD DE GESTION VISR
Nombre:__________________Cargo:_______________________
VIVIENDA NUEVA
DETALLE DE COLUMNAS DECONFINAMIENTO
17/35 15/08/2017
ZONA SÍSMICA ALTAAa= 0.25, Av= 0.25
Clima Frío > 2000 m.s.n.m
PROTOTIPO (2) VIVIENDA NUEVARESGUARDO PASTAS ALDANA -MUNICIPIO DE ALDANA - NARIÑO
Ing. Amaury Andrés Urueta MoraM.P.222-02212829 COR.
ORIGINAL FIRMADO POR PROFESIONAL
ELEMENTO ELEMENTOCANT.(Un)
CANT.(Un)
#BARRA #BARRA SUBTOTAL(kg)NOMBRE
T-1 #3Lc= 2.90m 4 #2 25 9.3 Lc= 0.45m
T-2 #3Lc= 3.45m 4 11.3
T-3 #3Lc= 3.90m 4 #2 35 12.7 Lc= 0.45m
T-4 #3Lc= 3.6m 4 #2 32 11.7 Lc= 0.45m
T-5 Lc= 3.3m #3 4 10.7
#2 31 Lc= 0.45m
#2 29 Lc= 0.45m
T-6 #3Lc= 2.9m 4 9.3#2 25 Lc= 0.45m
UNIDAD DE GESTION VISR
Nombre:__________________Cargo:_______________________
VIVIENDA NUEVA
CUADRO DE ACEROS DE COLUMNAS DECONFINAMIENTO
18/35 15/08/2017
ZONA SÍSMICA ALTAAa= 0.25, Av= 0.25
Clima Frío > 2000 m.s.n.m
PROTOTIPO (2) VIVIENDA NUEVARESGUARDO PASTAS ALDANA -MUNICIPIO DE ALDANA - NARIÑO
Ing. Amaury Andrés Urueta MoraM.P.222-02212829 COR.
ORIGINAL FIRMADO POR PROFESIONAL
A B B' C D E
3.02 1.02 1.5 1.42 1.28
2.9 2.45 2.43
0.44 0.46
0.9 0.86
0.31
Viga deCimentación
Viga deCimentación
Viga deCimentación
Viga CintaViga Cinta
0.3
UniónConcreto 1
UniónConcreto 2
DETALLE DEL REFUERZO (VISTA LATERAL IZQUIERDA)ESC: 1:50
0.00
+ 2.30
+ 3.30
Nivel de Piso
DETALLE UNIÓNCONCRETO 1
DETALLE UNIÓNCONCRETO 2
Se dispondrá dentro del refuerzo de lacolumna el refuerzo de la viga deconfinamiento y el refuerzo de la viga cintadentro de la viga de confinamiento. Se dispondrá dentro del
refuerzo de la columna elrefuerzo de la viga cinta. 2#3 Lc= 1.55m
6 # 2@ 0.20
1.34DETALLE (VIGA DINTEL)
SON 4
0.12
0.1 0.04
0.07
E#2 @ 0.20mLc:0.15m
Rec. 2.5 cm
CONCRETO 1
UNIDAD DE GESTION VISR
Nombre:__________________Cargo:_______________________
VIVIENDA NUEVA
CORTE ESTRUCTURAL, DETALLE DE DINTELVENTANAS Y DETALLE DE UNIONES DE
CONCRETO
19/35 15/08/2017
ZONA SÍSMICA ALTAAa= 0.25, Av= 0.25
Clima Frío > 2000 m.s.n.m
PROTOTIPO (2) VIVIENDA NUEVARESGUARDO PASTAS ALDANA -MUNICIPIO DE ALDANA - NARIÑO
Ing. Amaury Andrés Urueta MoraM.P.222-02212829 COR.
ORIGINAL FIRMADO POR PROFESIONAL
1
2
3
A B B' C D FE
1'
2'
A B B' C D FE
1
2
3
2'
3.02 1.02 1.5 1.42 1.28
2.1
0.85
0.73
2.94
3.02 1.02 1.5 1.42 1.28 1.64
0.03
0.02
VIGA CINTA3 (0.12 X 0.10)
VIGA CINTA 2 (0.12 X 0.10)
VIGA CINTA 1 (0.12 X 0.10)
VIGA
A (0
.12 X
0.17
)VI
GA A
(0.12
X 0.
17)
VIGA
CIN
TA B
(0.12
X 0.
10)
VIGA
CIN
TA E
(0.12
X 0.
10)
VIGA
CIN
TA C
(0.12
X 0.
10)
VIGA
CIN
TA D
(0.12
X 0.
10)
VIGA
F (0
.12 X
0.17
)
1.64
VIGA CINTA3 (0.12 X 0.10) VIGA CINTA3 (0.12 X 0.10)
VIGA CINTA 2 (0.12 X 0.10) VIGA CINTA 2 (0.12 X 0.10)
VIGA CINTA 1 (0.12 X 0.10) VIGA CINTA 1 (0.12 X 0.10)
VIGA
CIN
TA B
(0.12
X 0.
10)
1.64
Ver DetalleUnión Tipo 1
Ver DetalleUnión Tipo 1
Ver DetalleUnión Tipo 1
Ver DetalleUnión Tipo 1
Ver DetalleUnión Tipo 1
Ver DetalleUnión Tipo 1
Ver DetalleUnión Tipo 1
Ver DetalleUnión Tipo 1
Ver DetalleUnión Tipo 1
Ver DetalleUnión Tipo 1
Ver DetalleUnión Tipo 1
PHR
C 10
0X50
- 1.5
mmPH
R C
100X
50 -
1.5mm
PHR
C 10
0X50
- 1.5
mmPH
R C
100X
50 -
1.5mm
PHR
C 10
0X50
- 1.5
mm
PHR
C 10
0X50
- 1.5
mm
PHR
C 10
0X50
- 1.5
mm
PHR
C 10
0X50
- 1.5
mm
0.220.22
2
2'' 2''
TempleteVarilla 1/2"
TempleteVarilla 1/2"
TempleteVarilla 1/2"
TempleteVarilla 1/2"
TempleteVarilla 1/2"
TempleteVarilla 1/2"
TempleteVarilla 1/2"
TempleteVarilla 1/2"
TempleteVarilla 1/2"
TempleteVarilla 1/2"
1.62
2'''
0.38
VIGA CINTA 2''' (0.12 X 0.10)
PLANTA ESTRUCTURAL DE VIGAS DE CUBIERTAESC: 1_50
UNIDAD DE GESTION VISR
Nombre:__________________Cargo:_______________________
VIVIENDA NUEVA
PLANTA ESTRUCTURAL DE CUBIERTA
20/35 15/08/2017
ZONA SÍSMICA ALTAAa= 0.25, Av= 0.25
Clima Frío > 2000 m.s.n.m
PROTOTIPO (2) VIVIENDA NUEVARESGUARDO PASTAS ALDANA -MUNICIPIO DE ALDANA - NARIÑO
Ing. Amaury Andrés Urueta MoraM.P.222-02212829 COR.
ORIGINAL FIRMADO POR PROFESIONAL
9 # 2@ 0.30
2#3 Lc= 5.0m
10 # 2@ 0.30
5 # 2@ 0.30
10 # 2@ 0.30
2#3 Lc= 6.0m
A B B' C D FE
3.02 1.02 1.5 1.42 1.28 1.64
VIGA CINTA 2, 3 (0.12 x 0.10)
A B B' C D E
3.02 1.02 1.5 1.42 1.28
9 # 2@ 0.30
2#3 Lc= 5.0m
10 # 2@ 0.30
9 # 2@ 0.30
2#3 Lc= 4.3m
VIGA CINTA 1 (0.12 x 0.10)
1
2.1
2#3 Lc= 4.5m
VIGA CINTA B (0.12 x 0.10)
7 # 2@ 0.30
8 # 2@ 0.30
0.85 0.73
2#3 Lc= 2.3m
1' 2 2' 3
2.2
2 # 2@ 0.30
3 # 2@ 0.30
VIGA CINTA C, D, F (0.12 x 0.10)
7 # 2@ 0.30
0.94
2#3 Lc= 3.25m
2 2'' 3
1.99
2 # 2@ 0.30
VIGA CINTA E (0.12 x 0.10)
10 # 2@ 0.30
2#3 Lc= 3.25m
1 2
2.94
VIGA CINTA 2''' (0.12 x 0.10)
5 # 2@ 0.30
2#3 Lc= 2.85m
B C
1.5
B'
1.02
4# 2@ 0.30
0.12
0.1 0.04
0.06
E#2 @ 0.30mLc: 0.14m
Rec. 3.0 cm
0.12
0.1 0.04
0.06
E#2 @ 0.30mLc: 0.14m
Rec. 3.0 cm
0.12
0.1 0.04
0.06
E#2 @ 0.30mLc: 0.14m
Rec. 3.0 cm
0.12
0.1 0.04
0.06
E#2 @ 0.30mLc: 0.14m
Rec. 3.0 cmDESPIECE DE VIGAS CINTAESC: 1:50
UNIDAD DE GESTION VISR
Nombre:__________________Cargo:_______________________
VIVIENDA NUEVA
DESPIECE DE VIGAS CINTA
21/35 15/08/2017
ZONA SÍSMICA ALTAAa= 0.25, Av= 0.25
Clima Frío > 2000 m.s.n.m
PROTOTIPO (2) VIVIENDA NUEVARESGUARDO PASTAS ALDANA -MUNICIPIO DE ALDANA - NARIÑO
Ing. Amaury Andrés Urueta MoraM.P.222-02212829 COR.
ORIGINAL FIRMADO POR PROFESIONAL
ELEMENTO CANT.(Un)
ELEMENTO CANT.(Un)
#BARRA #BARRA SUBTOTAL(kg)NOMBRE
VC-2,3 #3Lc= 5.0m 2 #2 34 9.4
#3Lc= 6.0m 2 6.7
#3Lc= 5.0m 2 #2 28 8.8
#3Lc= 4.3 m 2 4.8
#3Lc= 4.5m 2 7.3
VC-2,3
VC-1
VC-B
Lc: 0.14m
Lc: 0.14m
Lc: 0.14m #2 20
#3Lc= 2.3m 2 2.6VC-B
#3Lc= 3.25m 2 4.7VC-C,D,F
VC-1
Lc: 0.14m#2 9
#3Lc= 3.25m 2 4.8VC-E Lc: 0.14m #2 10
#3Lc= 2.85m 2 4.2VC-2''' Lc: 0.14m#2 9
UNIDAD DE GESTION VISR
Nombre:__________________Cargo:_______________________
VIVIENDA NUEVA
CUADRO DE ACEROS VIGAS CINTA
22/35 15/08/2017
ZONA SÍSMICA ALTAAa= 0.25, Av= 0.25
Clima Frío > 2000 m.s.n.m
PROTOTIPO (2) VIVIENDA NUEVARESGUARDO PASTAS ALDANA -MUNICIPIO DE ALDANA - NARIÑO
Ing. Amaury Andrés Urueta MoraM.P.222-02212829 COR.
ORIGINAL FIRMADO POR PROFESIONAL
Teja fibrocemento N°6
Teja fibrocemento N°6
Teja fibrocemento N°5
Teja fibrocemento N°5
Teja fibrocemento N°10
Teja fibrocemento N°6
Caballete Articulado Ondulado
Teja fibrocemento N°6
Teja fibrocemento N°6
Teja fibrocemento N°5
Teja fibrocemento N°5
Teja fibrocemento N°10
Caballete Articulado Ondulado
A B B' C D FE
3.02 1.02 1.5 1.42 1.28
1.64
DETALLE DISTRIBUCIÓNLÁMINAS DE CUBIERTA
ESC: 1_50
VIGA CINTA (0.12x0.10)
DETALLE UNIÓNTIPO 1
16 "
E7011
4#4 Lc=0.12m60mm 60mmL
Extremo RoscadoDETALLE TEMPLETE
VARILLA 1/2"
UNIDAD DE GESTION VISR
Nombre:__________________Cargo:_______________________
VIVIENDA NUEVA
DETALLE DE CUBIERTA, DETALLE DEUNIÓN PERFIL - VIGAS DE CONCRETO
23/35 15/08/2017
ZONA SÍSMICA ALTAAa= 0.25, Av= 0.25
Clima Frío > 2000 m.s.n.m
PROTOTIPO (2) VIVIENDA NUEVARESGUARDO PASTAS ALDANA -MUNICIPIO DE ALDANA - NARIÑO
Ing. Amaury Andrés Urueta MoraM.P.222-02212829 COR.
ORIGINAL FIRMADO POR PROFESIONAL
DETALLE LAVADERO
DETALLE LAVADERO(VISTA EN PLANTA)
Bloque Tolete Macizo
Placa de contrapiso e= 6cm
Bloque arcilla #5 perforaciónhorizontal
Lavadero prefabricado
MAX. 0.90m0.5
1
#2 @ 0.18m
#2 @ 0.20m #2 @ 0.20m1.4
0.6
0.8
1.3
0.6
1.9
0.140.13
Bloque Tolete Macizo
0.1
Concreto 2500 PSI E= 10cm
MAX. 0.95m
0.05
0.6
0.56
DETALLE MESÓN DE COCINA(VISTA EN PLANTA)
DETALLE MESÓN DE COCINA(VISTA FRONTAL)
1.9
UNIDAD DE GESTION VISR
Nombre:__________________Cargo:_______________________
VIVIENDA NUEVA
DETALLE DE MESÓN DE COCINA YLAVADERO
24/35 15/08/2017
ZONA SÍSMICA ALTAAa= 0.25, Av= 0.25
Clima Frío > 2000 m.s.n.m
PROTOTIPO (2) VIVIENDA NUEVARESGUARDO PASTAS ALDANA -MUNICIPIO DE ALDANA - NARIÑO
Ing. Amaury Andrés Urueta MoraM.P.222-02212829 COR.
ORIGINAL FIRMADO POR PROFESIONAL
12
3
A B B'
C D FE
AFP
PVC
1/2"
AFP PVC 1/2"
AFP
PVC
1/2"
AFP
PVC
1/2"
Term
inal d
eco
nexió
n a re
dde
acue
ducto
Proy
ecció
n de
caja
de m
edido
res
Cone
xión d
edu
cha
Cone
xión d
elav
ader
o
Sube
0.25
mCo
locar
tapó
n
Cone
xión d
elav
aman
osSu
be 0.
5 m
Cone
xión d
elav
aplat
os su
be 0.
6 m
Sube
0.25
m
Regis
tro Ø
1/2"
Baja
0.25 m
Cone
xión d
e San
itario
Sube
0.2 m
PLANTA TUBERÍA HIDRÁULICAESC: 1_50
UNIDAD DE GESTION VISR
Nombre:__________________Cargo:_______________________
VIVIENDA NUEVA
DETALLE TUBERÍA HIDRÁULICA
25/35 15/08/2017
ZONA SÍSMICA ALTAAa= 0.25, Av= 0.25
Clima Frío > 2000 m.s.n.m
PROTOTIPO (2) VIVIENDA NUEVARESGUARDO PASTAS ALDANA -MUNICIPIO DE ALDANA - NARIÑO
Ing. Leonardo Cortes PradoM.P.25202-213004 CND
ORIGINAL FIRMADO POR PROFESIONAL
12
3
A B B'
C D FE
0.60m
X 0.
60m
A
Sifón
de pi
so 2"
S PV
C 4"
S=3
.0% P
VC 2"
S=3
.0%
S PVC 2"
S PVC 4" S=3.0% S PVC 4" S=3.0%
Sifón
de pi
so 2"
Sifón
de pi
so 2"
Tamp
ón P
VC 4"
Sifón
de pi
so 2"
Caja
de in
spec
ción
0.6m
X0.6
m
2"
S PVC 2"
S PVC 2"
S PV
C 2"
4"
Cone
xión d
elav
aplat
os Ø
2"su
be 0.
5 m
Cone
xión d
elav
aman
os Ø
2"Su
be 0.
5 m
Cone
xión d
elav
ader
o Ø 2"
PLANTA TUBERÍA SANITARIAESC: 1_50
UNIDAD DE GESTION VISR
Nombre:__________________Cargo:_______________________
VIVIENDA NUEVA
DETALLE TUBERÍA SANITARIA
26/35 15/08/2017
ZONA SÍSMICA ALTAAa= 0.25, Av= 0.25
Clima Frío > 2000 m.s.n.m
PROTOTIPO (2) VIVIENDA NUEVARESGUARDO PASTAS ALDANA -MUNICIPIO DE ALDANA - NARIÑO
Ing. Leonardo Cortes PradoM.P.25202-213004 CND
ORIGINAL FIRMADO POR PROFESIONAL
UNIDAD DE GESTION VISR
Nombre:__________________Cargo:_______________________
VIVIENDA NUEVA
DETALLE HIDROSANITARIOS
27/35 15/08/2017
ZONA SÍSMICA ALTAAa= 0.25, Av= 0.25
Clima Frío > 2000 m.s.n.m
PROTOTIPO (2) VIVIENDA NUEVARESGUARDO PASTAS ALDANA -MUNICIPIO DE ALDANA - NARIÑO
Ing. Leonardo Cortes PradoM.P.25202-213004 CND
ORIGINAL FIRMADO POR PROFESIONAL
TABLERO DE DISTRIBUCION DEL
USUARIO TIPO TQ-SP O TBL-BO (12
CIRCUITOS)
NI01 NI02 NT01 NT02 NT03 NT04 NT05
1X20A
Square D
10 kA
1X20A
Square D
10 kA
1X20A
Square D
10 kA
1X20A
Square D
10 kA
1X20A
Square D
10 kA
1X20A
Square D
10 kA
N
T
CONDUCTOR DEL
ELECTRODO DE
PUESTA A TIERRA.
EN NUMERO 8 Cu
DESNUDO
Varilla
5
8
Cu 2.4m
NOTA DE REGIMEN DE CONEXION DE TIERRA
1. EL REGIMEN DE CONEXION DE TIERRA SERA TNC-S.
2. AGUAS ARRIBA DEL TABLERO DE DISTRIBUCION DEL USUARIO
ES TNC.
3. AGUAS ABAJO DEL TABLERO DE DISTRIBUCION DEL USUARIO ES
TNS.
NOTA DEL CONDUCTOR DEL ELECTRODO DE PUESTA A TIERRA
1. EL CONDUCTOR DEL ELECTRODO DE PUESTA A TIERRA SE SELECCIONO DE
ACUERDO AL RETIE Y LA TABLA 250-94 DE LA NTC 2050 Y ES CALIBRE 8AWG
DESNUDO Cu
NOTA DE CONDUCTOR DE PUESTA A TIERRA DE
EQUIPOS Y NEUTRO
1. DEBEN DE INSTALARSE TANTOS NEUTROS Y TIERRAS COMO
INTERRUPTORES, CIRCUITOS O DERIVACIONES HAYAN
P INSTALADA:9760 VA
CORRIENTE: 41A
2x6F
C
u A
WG
T
HH
N 1Ø
1/4" P
VC
T
ipo A
NT06 NT07 NT08
1X30A
Square D
10 kA
1X20A
Square D
10 kA
1X20A
Square D
10 kA
1X20A
Square D
10 kA
CIR
CU
IT
O D
E D
UC
HA
CIR
CU
IT
O D
E C
OC
IN
A
CIR
CU
IT
O D
E N
EV
ER
A
KWH
KVArh
MEDICIÓN DIRECTA EN B.T.
1
CONTRATISTA
A ESPECIFICAR POR OTRO
INTERRUPTOR
BIPOLAR
A DIMENSIONAR
POR OTRO
CONTRATISTA
BARRAJE PEN
CONDUCTOR PEN NUMERO 6 AWG THHN Cu
CONDUCTOR PEN RED PUBLICA
ACOMETIDA A DEFINIR POR OTRO CONTRATISTA
LISTRADO DE EQUIPOS
1. CAJA PARA MEDIDOR BIFASICO NORMA AE303 DE CODENSA SA ESP
2. TABLERO DE DISTRIBUCION DEL USUARIO TIPO TQ-SP O TBL-BO DE 12
CIRCUITOS
UNIDAD DE GESTION VISR
Nombre:__________________
Cargo:_______________________
ZONA SÍSMICA ALTA
Aa= 0.25, Av= 0.25
Clima Frio > 2000
m.s.n.m
PROTOTIPO (2) VIVIENDA NUEVARESGUARDO PASTAS ALDANA -MUNICIPIO DE ALDANA - NARIÑO
VIVIENDA NUEVA
DIAGRAMA UNIFILAR
28/35
15/08/2017
Ing. Juan David Garcia Moreno
M.P.CN205-101690
ORIGINAL FIRMADO POR PROFESIONAL
NOTA:
· EN OBRA SE DEFINE LA POSICION FINAL DE ACUERDO A EL
ELEMENTO DIVISORIO
· PARA TODO TOMACORRIENTE SE INSTALARA EN TUBERIA 3/4", A
MENOS QUE SE ESPECIFIQUE EN PLANO OTRO DIAMETRO.
· SE EMPLEARAN LOS CONDUCTORES MENCIONADOS EN ESTAS
CONVENCIONES A MENOS QUE SE ESPECIFIQUE EN PLANO OTRO
CALIBRE.
· ACOMETIDAS EN DUCTO Y CALIBRE SEGUN CUADRO DE CARGAS
NOTA:
· EN OBRA SE DEFINE LA POSICION FINAL DE ACUERDO A EL
ELEMENTO DIVISORIO
· PARA TODA SALIDA SE INSTALARA EN TUBERIA 1/2", A MENOS QUE
SE ESPECIFIQUE EN PLANO OTRO DIAMETRO.
· SE EMPLEARAN LOS CONDUCTORES MENCIONADOS EN ESTAS
CONVENCIONES A MENOS QUE SE ESPECIFIQUE EN PLANO OTRO
CALIBRE.
· ACOMETIDAS EN DUCTO Y CALIBRE SEGUN CUADRO DE CARGAS
Nombre:__________________
Cargo:_______________________
ZONA SÍSMICA ALTA
Aa= 0.25, Av= 0.25
Clima Frio > 2000
m.s.n.m
PROTOTIPO (2) VIVIENDA NUEVARESGUARDO PASTAS ALDANA -MUNICIPIO DE ALDANA - NARIÑO
VIVIENDA NUEVA
CONVENCIONES ELECTRICAS
15/08/2017
29/35
Ing. Juan David Garcia Moreno
M.P.CN205-101690
UNIDAD DE GESTION VISR
ORIGINAL FIRMADO POR PROFESIONAL
2.90
2.8
2
2.8
2
1.2
0
1.38
1.9
0
10.00
1.64
1.0
0
2.00
.8
0
1.30
2.8
2
5.10
.8
0.8
0
.90
1.2
0
2.80
1.2
01
.2
0
6.0
0
A'
BB
'
12
3
A B B'
C D FE
CC
'
M
1
2
0.3
4.46
3x6F Cu AWG THHN
1Ø1/4" PVC Tipo A
Conductor del electrodo de puesta a tierra.
8 A
WG
C
u.
En tuberia em
bebida 3/4 P
VC
T
ipo A
Nombre:__________________
Cargo:_______________________
ZONA SÍSMICA ALTA
Aa= 0.25, Av= 0.25
Clima Frio > 2000
m.s.n.m
PROTOTIPO (2) VIVIENDA NUEVARESGUARDO PASTAS ALDANA -MUNICIPIO DE ALDANA - NARIÑO
VIVIENDA NUEVA
ALIMENTADORES
ESC: 1:50
15/08/2017
30/35
Ing. Juan David Garcia Moreno
M.P.CN205-101690
UNIDAD DE GESTION VISR
ORIGINAL FIRMADO POR PROFESIONAL
2.90
2.8
2
2.8
2
1.2
0
1.38
1.9
0
10.00
1.64
1.0
0
2.00
.8
0
1.30
2.8
2
5.10
.8
0.8
0
.90
1.2
0
2.80
1.2
01
.2
0
6.0
0
A'
BB
'
12
3
A B B'
C D FE
CC
'
1
2
2
1
1
1
1
2
1
Ver
not
a 1
1
1
1
1
1
2
2
1
1
1
1
1
2
1. 3x12 AWG THHN 1Ø3/4" PVC Tipo A2. 4x12 AWG THHN 1Ø3/4" PVC Tipo A
CONDUCTORES EN TUBERIA Y TUBERIA
NOTAS DE SALIDAS DE ILUMINACION
1. CAJA DE PASO 2400 ISNTALADA ENMURO Y CON TAPA CIEGA
Nombre:__________________
Cargo:_______________________
ZONA SÍSMICA ALTA
Aa= 0.25, Av= 0.25
Clima Frio > 2000
m.s.n.m
PROTOTIPO (2) VIVIENDA NUEVARESGUARDO PASTAS ALDANA -MUNICIPIO DE ALDANA - NARIÑO
VIVIENDA NUEVA
ILUMINACION
ESC: 1:50
15/08/2017
31/35
Ing. Juan David Garcia Moreno
M.P.CN205-101690
UNIDAD DE GESTION VISR
ORIGINAL FIRMADO POR PROFESIONAL
2.90
2.8
2
2.8
2
1.2
0
1.38
1.9
0
10.00
1.64
1.0
0
2.00
.8
0
1.30
2.8
2
5.10
.8
0.8
0
.90
1.2
0
2.80
1.2
01
.2
0
6.0
0
A'
BB
'
12
3
A B B'
C D FE
CC
'
Ver
not
as
Ver
not
as
Ver
not
as
Ver
not
as
Ver
not
a 4
Ver
not
a 4
Ver
not
a 4
Ver
not
a 4
1 1
1 1 11
1
1
1
1
1
1
2
3
1
1
1
2
2
1
1
2
2
1
2
1. 3x12 AWG THHN 1Ø1/2" PVC Tipo ACONDUCTORES EN TUBERIA Y TUBERIA
2. 6x12 AWG THHN 1Ø1/2" PVC Tipo A3. 3x10 AWG THHN 1Ø1/2" PVC Tipo A
NOTAS DE CIRCUITOS DE TOMAS
1. EL CIRCUITO NT-08 ES PARA LA DUCHA YSE INSTALARA A LA ALTURA DE LAMISMA
2. EL CIRCUITO NT-07 ES CIRCUITOEXCLUSIVO PARA COCINA Y SU ALTURASERA DE 10 cms MEDIDOS DESDE LAPARTE MAS ALTA DEL MESON DE COCINA
3. EL CIRCUITO NT-06 ES EXCLUSIVO PARANEVERA
4. LA ALTURA DE INSTALACION SERA DE2.1m MEDIDOS DESDE EL SUELO
Nombre:__________________
Cargo:_______________________
ZONA SÍSMICA ALTA
Aa= 0.25, Av= 0.25
Clima Frio > 2000
m.s.n.m
PROTOTIPO (2) VIVIENDA NUEVARESGUARDO PASTAS ALDANA -MUNICIPIO DE ALDANA - NARIÑO
VIVIENDA NUEVA
SALIDAS DE TOMAS
ESC: 1:50
15/08/2017
32/35
Ing. Juan David Garcia Moreno
M.P.CN205-101690
UNIDAD DE GESTION VISR
ORIGINAL FIRMADO POR PROFESIONAL
NOTAS:
- Dimensiones en mm .
- Dimensiones de la caja: 570x270x180 mm .
- Para mayor información consultar la Especificación Técnica ET 900
Caja para medidor Trifásico.
Detalle B
10
15
CORTE A-A
15
Estructura
Puerta
DETALLE B
Acero inoxidable
DETALLE A
38.1 mm. (1 1/2")
31.75 mm. (1 1/4")
25.4 mm. (1")
Policarbonato
de 3mm
Ver detalle A
Perno de seguridad
con rosca RW
1
4
"
Puerta ajustable
Policarbonato
de 3mm
U
s
o
e
x
c
l
u
s
i
v
o
c
l
i
e
n
t
e
C
O
D
E
N
S
A
U
s
o
e
x
c
l
u
s
i
v
o
c
l
i
e
n
t
e
C
O
D
E
N
S
A
termomagnético
Soporte interruptor
Bandeja soporte
medidor
570
180
270
65
290
200
120
A
A
75
7000
Varilla de
puesta a tierra
Tapa inspeccionable para
varilla de puesta a tierra (Nota 6)
3000
Chazo metálico de expansión
para perno de 3/8"(n 90)
SOPORTE EN ANGULO DE 3/4"x3/4"x1/16"x1000mm
1000
100
50
1000
Ø 7/16"
Soporte en ángulo de 3/4"x3/4"x1/16"x1000mm
Chazo metálico de expansión
para perno de 3/8"
Calzada
Nombre:__________________
Cargo:_______________________
ZONA SÍSMICA ALTA
Aa= 0.25, Av= 0.25
Clima Frio > 2000
m.s.n.m
PROTOTIPO (2) VIVIENDA NUEVARESGUARDO PASTAS ALDANA -MUNICIPIO DE ALDANA - NARIÑO
VIVIENDA NUEVA
DETALLES
ESC: SIN ESCALA
15/08/2017
33/35
Ing. Juan David Garcia Moreno
M.P.CN205-101690
UNIDAD DE GESTION VISR
DETALLES TIPO DE DERIVACION DE
RED PUBLICA
ESC: SIN
DETALLES TIPO DE CAJA PARA
MEDIDOR BIFASICO
ESC: SIN
ORIGINAL FIRMADO POR PROFESIONAL
1.200
ESPECIFICACIONES:
.840 .360
BATIENTE CON MARCO
EN ALUMINIO
VENTANA EN ALUMINIO
DE 1.20X1.20Mts
CON VIDRIO DE 3mm
SUMINISTRO E INSTALACIÓN DE PUERTA METÁLICA 0,90M X 2,10M.
CALIBRE 18 CON MARCO, INCLUYE:
·PUERTA METÁLICA 0,82M X 2,05M. INCLUYE MARCO
· CERRADURA DE SEGURIDAD
· BISAGRA PERNO PUERTA 3"
·ANTICORROSIVO
· PINTURA DE ACABADO TIPO ESMALTE COLOR BLANCO
·SOLDADURA 6030
SUMINISTRO E INSTALACIÓN DE PUERTA EN MADERA 0,70 X 2,10M
CON ACABADO CON MARCO, INCLUYE:
·
· CERRADURA POMO EN MADERA
·BISAGRA PUERTA 3"
SUMINISTRO E INSTALACIÓN DE PUERTA EN MADERA 0,80 X 2,10M
CON ACABADO CON MARCO Y VENTILACIÓN SUPERIOR, INCLUYE:
·
· CERRADURA POMO EN MADERA
·BISAGRA PUERTA 3"
Detalle de Ventana tipo 1
SUMINISTRO E INSTALACION DE VENTANA EN ALUMINIO.
CON VIDRIO COLOR AZUL, INCLUYE:
·
·MARCO EN ALUMINIO 1,20M X 1,20M
VIDRIO COLOR AZUL 3MM
· MANIJA VENTANA DERECHA
·
.800
.900.700
PUERTA EN MADERA
(INCLUYE MARCO)
2.10X0.80Mts
PUERTA CON MARCO
METALICO 2.10X0.90Mts
PUERTA DE MADERA
(INCLUYE MARCO)
2.10X0.70Mts
.10
.04
Detalle de Puertas interiores (80cm)
.52 .10
.10
.04
.04
Detalle de Puerta exterior
.04
.04 .04
Detalle de Puertas interiores (70cm)
Tubo metálico C.18
Lámina en madera
Bisagra de 3"
Bisagra
Lámina en madera
Bisagra de 3"
Bastidor de madera pino o similar
.04
Muro E.12cm
Marco en madera pino o similar
DETALLE DE PUERTA EN MADERA
Cerradura pomo
en madera
Marco tubo metálico
C.18
Perfil C.18
Cerradura de
seguridad
Lámina C.18
Cerradura pomo
en madera
DETALLE DE PUERTA METALICA
Bastidor de madera pino o similar
.04
Marco en madera pino o similar
Muro E.12cm
DETALLE DE PUERTA EN MADERA
.62 .10
.10 .42 .10
MANIJA VENTANA IZQUIERDA
PUERTA MADERA 0,62M X 2,05M. INCLUYE MARCO Y VENTILACIÓN SUPERIOR
PUERTA MADERA 0,72M X 2,05M. INCLUYE MARCO Y VENTILACIÓN SUPERIOR
.10
1.200
.050
2.1
0
1.120
.1
5.7
3.1
0.9
8.1
0.0
4
.0
8
2.1
0
.1
41
.8
2.1
0.0
4
2.1
0
.050
.1
0.9
2.1
0.8
4.1
0 .0
4
.10
UNIDAD DE GESTION VISR
Nombre:__________________Cargo:_______________________
VIVIENDA NUEVA
PROPIEDAD INTELECTUAL
34/35 15/08/2017
ZONA SÍSMICA ALTAAa= 0.25, Av= 0.25
Clima Frío > 2000 m.s.n.m
PROTOTIPO (2) VIVIENDA NUEVARESGUARDO PASTAS ALDANA -MUNICIPIO DE ALDANA - NARIÑO
Ing. Amaury Andrés Urueta MoraM.P.222-02212829 COR.
ORIGINAL FIRMADO POR PROFESIONAL
PROPIEDAD INTELECTUALEl Anteproyecto y Proyecto Arquitectónico, Estructural,H i d r o s a n i t a r i o , H i d r á u l i c o y E l é c t r i c o s o nde p r op iedad i n te lec tua l de F IDUAGRARIA S .A . ypo r cons igu ien te , so lamen te pueden usa r se en l aconstrucción de la vivienda para el cual fueron elaborados ypara uso exclusivo de la Gerencia de Vivienda del BancoAgrario de Colombia. Ninguna persona podrá modif icarAnteproyectos ni cambiar Proyectos sin el visto bueno deF I D U A G R A R I A S . A . , s o p e n a d e v i o l a r l a sdisposiciones de la Ley 23 de 1982, sobre Derechos deAutor, excepto en el caso que el Anteproyecto haya sidoe laborado d i rectamente por la ent idad cont ra tante .No se podrán utilizar Anteproyectos y Proyectos en obrasdiferentes a aquellas para cuales fueron contratadas.
UNIDAD DE GESTION VISR
Nombre:__________________Cargo:_______________________
VIVIENDA NUEVA
PROPIEDAD INTELECTUAL
35/35 15/08/2017
ZONA SÍSMICA ALTAAa= 0.25, Av= 0.25
Clima Frío > 2000 m.s.n.m
PROTOTIPO (2) VIVIENDA NUEVARESGUARDO PASTAS ALDANA -MUNICIPIO DE ALDANA - NARIÑO
Ing. Amaury Andrés Urueta MoraM.P.222-02212829 COR.
ORIGINAL FIRMADO POR PROFESIONAL