www.solectria.com
MADE IN THE USA
Solectria - A Yaskawa Company is a leading grid-tied PV inverter
manufacturer based in Lawrence, Massachusetts. Solectria
offers a versatile line of high-efficiency/high-value inverter
solutions supported by exceptional engineering talent and
world-class warranties.
Solar power is reaching cost parity with conventional energy
sources in North America, driving aggressive demand for
large solar projects and project portfolios. Those that will be
successful need the best technology from reliable partners.
Solectria is the right choice for large commercial and utility-
scale projects.
SOUNDA secure partner invested in your success: Solectria
was acquired by Yaskawa America, Inc. in September
2014. Solectria continues to manufacture all of its
3-phase central inverters, utility-scale inverters,
monitoring systems and combiner boxes in the U.S.A.
SIMPLESimple, innovative technologies at exceptional value:
Built on 25 years of experience with power electronics
and inverters, Solectria’s elegant designs lower costs
and improve reliability. Solectria’s solutions deliver
exceptional uptime and are engineered to work with
current and future North American grid standards.
SMARTReady for the utility grid of today and tomorrow:
Solectria is committed to developing the next
generation of utility-grade systems that ensure grid
stability and enable higher penetration. Solectria
has partnered with EPRI and leading utilities as well
as the U.S. Department of Energy SunShot program
to develop and test technologies that accommodate
evolving standards.
SUSTAINABLESustainable solutions backed by a solid, secure team:
Solectria offers exceptional engineering support
throughout the project lifecycle, including a world-
class customer support team committed to rapid and
professional response.
PVI SERIESSolectria’s series of PVI commercial string and central
inverters are the most customizable commercial grid-tied
PV inverters available today. Offering the highest peak and
CEC efficiencies in the industry, they include options such as
intelligent communications, real power curtailment, reactive
power control, and voltage and frequency ride through.
Customers have chosen Solectria’s PVIs for projects ranging
from 50kW up to 30MW.
SGI SERIESSolectria’s SMARTGRID inverters boast industry-leading CEC
efficiencies - 97.5% with integrated transformer or 98% with
external transformer - and deliver exceptional reliability and
economy. The SGI XT and XTM inverters are designed for direct
connection to an external transformer and include advanced
grid management features such as fault ride through, real
and reactive power control, and power factor control. These
inverters are deployed in a large number of commercial and
utility-scale systems across North America ranging from
200kW to multi-MW.
MEGAWATT SOLAR STATIONSSolectria’s Megawatt Solar Stations (MSS) are fully-integrated
solutions for medium voltage applications. They include up to
four inverters, padmount transformer, and switchgear, greatly
simplifying field installation. They are available as an open
skid, enclosure or canopy.
MonitoringSolrenView™ WEB-BASED PV MONITORINGSolrenView monitoring provides PV system owners a highly accurate and real time web-basedmonitoring solution to maximize efficiency and profitability of their solar assets. Solectria’s SolrenView web-based monitoring solution is available for use with residential, commercial, and utility-scale inverters, allowing for real-time, seamless recording and reporting of PV system production. The SolrenView data logger comes standard and fully-integrated within all 3-phase commercial and utility-scale inverters. A standalone SolrenView data logger is available for Solectria’s PVI 3800-7600TLs and PVI 14-36TLs. The complete SolrenView system features inverter direct monitoring, revenue grade monitoring, agency reporting, SolZone™ sub-array current monitoring, XML feed, kiosk view and weather station.
SolrenView™ Inverter Direct (standard monitoring package)
SolrenView Inverter Direct monitoring allows customers to see detailed operational inverter data (DC and AC) using a web enabled device. This standard package allows customers to view daily, weekly, monthly, and annual graphs up to 5 years into the past, viewing single events or long-term performance trends. The package includes e-mail and cell phone alerts with detailed descriptions of system issues and a recommended course of action.
SolrenView™ Revenue Grade Energy Production (optional monitoring package)
SolrenView Revenue Grade Energy Production Monitoring package option keeps track of lifetime energy produced by a customer’s PV system. This package option also includes e-mail alerts with detailed descriptions of system problems and a recommended course of action. Compatible with all third party inverters.
SolrenView™ SolZone™ DC Current Sub-Array Monitoring (option)
SolZone provides an extra level of granularity to see multiple sub-array DC currents. SolZone has the ability to compare individual PV zones against each other based on the number of sub-array fuses or ‘zones’ built into a Solectria factory-installed DC subcombiner. This package option also include e-mail alerts and description of zone under performance. SolZone is also compatible with most third party monitoring systems.
SolrenView™ Agency Reporting (option)
SolrenView Agency Reporting is for customers that require a revenue grade energy production report to be sent to an agency such as NEPOOL, WREGIS, MassCEC, PG&E, SCE, CCSE, IID or PaCE. A report is generated from SolrenView Revenue Grade metering outputs and sent directly to the agency of choice. Solectria Renewables’ staff works directly with agencies to activate and maintain solar production credit accounts.
SolrenView™ Kiosk View (standard animated view)
The Kiosk View (Animated View) provides customers with a clean, quick and easy access to a customer’s PV system performance. This is a great tool for advertising and public viewing. When the “Animated View” button is clicked on the SolrenView screen, SolrenView will continuously loop though the site overview, environmental foot print, project details, site analytics, and if applicable, the detailed analytics page.
SolrenView™ Weather Station (option)
SolrenView Weather Station is a real-time weather package which allows customers to view accurate readings of crucial environmental information that affect the performance of your PV system. The weather station comes standard with a solar irradiance sensor as well as temperature sensors for ambientand module measurements. Wind speed and wind direction sensors are options that may be added to the weather station. The weather station is a great educational tool and a must-have for PPAs. Complies with RS-485 SunSpec Environmental Sensor System.
Viewable Measurements: - Solar Irradiance - Ambient Temperature - Module Temperature - Wind Speed and Wind Direction (option)
SolrenView™ AIR (option)
The SolrenView AIR option permits customers to take advantage of SolrenView web-based monitoring features via a fully-integrated 3G cellular modem when standard internet access is not available at a site. SolrenView AIR may be factory integrated for any inverter 50 kW and greater (PVI 50-100KW, SGI 225-500PE, SGI 500XT & SGI 500/750XTM inverters).
SolrenView™ XML Feed (option)
SolrenView XML feed option provides a reporting framework for customers with a need to display real-time monitoring information about their PV system within their applications/website or using third party monitoring.
DC Input
Absolute Maximum Input Voltage 600 VDC 600 VDC 1000 VDC 600 VDC 600 VDC 600 VDC 1000 VDC
Operating Input Voltage Range, MPPT 120-550 VDC 180-580 VDC 260-580 VDC 300-900 VDC 280-950 VDC300-500 VDC 300-500 VDC 300-500 VDC 545-820 VDC
Full Power Input Voltage Range, MPPT 200-500 VDC 300-540 VDC 300-550 VDC 480-800 VDC 500-800 VDC 520-800 VDC
Full Power Input Voltage Range, MPPT - Low Voltage Option − − 285-500 VDC − −
Maximum Operating Input Current 20 A 15 A per MPP tracker 18 A per MPP tracker 20 A per MPP tracker 25 A per MPP tracker (50 A) 35 A per MPP tracker (70 A) 25 A per MPP tracker (50 A) 29 A per MPP tracker (58 A) 34 A per MPPT (68 A) 176 A 211 A 264 A 299 A 351 A 768 A 853 A 908 A 1026 A 1721/1712 A 1750 A 965 A 1445 A
Max Operating Input Current - Low Voltage Option − − 185 A 222 A 278 A 314 A 370 A − −
Start Voltage 150 V 300 V 330 V 400 V 390 V 390 V 700 V
Start Voltage - Low Voltage Option − − 380 V − −
AC Output
Nominal Output Voltage 208 or 240 VAC, 1-Ph 208 VAC, 3-Ph 480 VAC, 3-Ph 208, 240, 480 or 600 VAC, 3-Ph (3-wire standard, 4-wire optional ) 480 VAC, 3-Ph 480 or 600 VAC, 3-Ph 480 VAC, 3-Ph (3-wire standard, 4-wire optional) 208 VAC, 3-Ph 380 VAC, 3-Ph
Continuous Output Power 3.3 kW (208 VAC); 3.8 kW (240 VAC) 5.2 kW (208 VAC); 5.2 kW (240 VAC) 6.6 kW (208 VAC); 6.6 kW (240 VAC) 6.6 kW (208 VAC); 7.6 kW (240 VAC) 14 kW 20 kW 23 kW 28 kW 36 kW 50 kW 60 kW 75 kW 85 kW 100 kW 225 kW 250 kW 266 kW 300 kW 500 kW 500 kW 750 kW
Continuous Output Current 15.8 A (208 VAC); 15.8 A (240 VAC) 25 A (208 VAC); 21.6 A (240 VAC) 31.7 A (208 VAC); 27.5 A (240 VAC) 31.7 A (208 VAC); 31.7 A (240 VAC) 39 A 24 A 27.7 A 33.7 A 43.3 A 139/120/60/48 A 167/144/72/58 A 208/180/90/72 A 236/205/102/82 A 278/240/120/96 A 271 A 301/240 A 320 A 360 A 602 A 1387 A 760 A 1140 A
Max Fault Contribution Current 140 A (peak) 70.4 A (RMS) 43.3 A (RMS) 69.6 A (RMS) − 167 A (208 VAC); 144 A (240 VAC); 72 A (480 VAC) (RMS)
200 A (208 VAC); 173 A (240 VAC); 86 A (480 VAC) (RMS)
250 A (208 VAC); 216 A (240 VAC); 108 A (480 VAC) (RMS)
283 A (208 VAC); 246 A (240 VAC); 122 A (480 VAC) (RMS)
334 A (208 VAC); 288 A (240 VAC); 144 A (480 VAC) (RMS) 325.2 A (RMS) 361.2 A (RMS) 384 A (RMS) 432 A (RMS) 722 A (RMS) 1665 A (RMS) 912 A (RMS) 1368 A (RMS)
Power Factor Unity, > 0.99 Unity, >0.99 (±0.8 adjustable) Unity, >0.99 (±0.9 adjustable) Unity, >0.99 (±0.8 adjustable) Adjustable - 0.9 to +0.9, factory set at 1 Adjustable - 0.9 to +0.9, factory set at 1 Adjustable - 0.9 to +0.9, factory set at 1 Adjustable - 0.8 to +0.8, factory set at 1
Efficiency
Peak Efficiency (208/240/480/600 VAC) 98.3% 96.9% 97.4% 98.6% 98.5% 96.7/97.7/96.5/96.5% 96.7/97.8/96.5/96.5% 97.3/97.1/97.2/97.2% 96.6/96.7/96.9/96.9% 96.5/96.9/96.9/96.9% 98.0% 97.9% 98.1% 98.3%
CEC Efficiency (208/240/480 VAC) 97.5% 96.0% 97.0% 98.0% 96.0/97.0/96.0% 97.0/96.0/97.0% 96.0/96.0/96.5% 97.5% 97.0% 98.0%
Tare Loss < 1 W 4 W 2 W 1 W < 3 W 28 W 32 W 41 W 89 W 123 W
Combiners
Subcombiner or Integrated String Combiner Integrated string combiner:2 strings per tracker (1 tracker) Integrated string combiner: 2 strings per tracker (2 trackers) Integrated string combiner: 4 strings per tracker (2 trackers), 15 A (fused by-pass available) Subcombiner: Fuses or breakers, 2-8 positions, 40-300 A* Subcombiner: Fuses or breakers, 6-24 positions, 70-400 A* Subcombiner: Fuses or breakers,
8-32 positions, 70-400 A*Subcominber: Fuses or breakers,
8-32 positions, 70-400 A*Subcombiner: Fuses, 4 to 16 positions, 100-400 A*
Subcombiner: Breakers, 4 to 15 positions, 125-350 A*
Temperature
Ambient Temperature Range (full power) -13°F to +122°F (-25°C to +50°C) -13°F to +140°F (-25°C to +60°C) Derating occurs over +50°C -13°F to +140°F (-25°C to +60°C) Derating occurs over +45°C -40°F to +131°F (-40°C to +55°C) -40°F to +122°F (-40°C to +50°C) -40°F to +122°F (-40°C to +50°C)
Storage Temperature Range -40°F to +185°F (-40°C to +85°C) -22°F to +158°F (-30°C to +70°C) -58°F to +158°F (-40°C to +70°C) -40°F to +131°F (-40°C to +55°C) -40°F to +158°F (-40°C to +70) -40°F to +122°F (-40°C to +50°C)
Data Monitoring
Optional SolrenView Web-Based Monitoring External Integrated Integrated Integrated Integrated
Optional Revenue Grade Monitoring External External External 400 A 800 A 1600 A 800 A 1600 A
Optional Sub-Array Monitoring (DC Current) − − 2-8 zones 6 zones 8 zones 8 zones 1 zone per protected input (up to 16 zones)
Optional Cellular Communication − − SolrenView AIR SolrenView AIR SolrenView AIR
External Communication Interface RS-485 RS-485 Modbus RTU RS-485 SunSpec Modbus RTU RS-485 SunSpec Modbus RTU RS-485 SunSpec Modbus RTU
Testing & Certifications
Safety Listings & Certifications UL 1741/IEEE 1547, UL 1699B, CSA C22.2#107.1, FCC part 15 A&B UL 1741/IEEE 1547, CSA C22.2#107.1, FCC part 15B UL 1741/IEEE 1547, CSA C22.2#107.1, FCC part 15B UL 1741/IEEE 1547, CSA C22.2#107.1, FCC part 15B UL 1741/IEEE 1547, CSA C22.2#107.1
Certification Agency ETL CSA ETL ETL ETL ETL
Warranty
Standard 10 year 10 year 5 year 5 year 5 year
Optional − 15, 20 year; extended service agreement 10, 15, 20 year; extended service agreement; uptime guarantee 10, 15, 20 year; extended service agreement; uptime guarantee 10, 15, 20 year; extended service agreement; uptime guarantee
Enclosure
dBA (Decibel) Rating < 45 dBA @ 3 m < 50 dBA @ 3 m < 62 dBA @ 3 m < 60 dBA @ 5 m < 59 dBA @ 3 m < 67 dBA @ 10 m
Transformer Transformerless Transformerless Standard, fully-integrated (internal) Standard, fully-integrated (internal); external optional Dedicated external transformer required, refer to external transformer specifications
AC/DC Disconnect DC disconnect, fully-integrated Standard, fully-integrated Standard, fully-integrated Fully-integrated (internal) DC disconnect: integrated, standard; AC disconnect/breaker: optional disconnect, breaker or breaker with shunt trip
Dimensions (H x W x D) 17.5 x 15.8 x 8.5 in. (445 x 402 x 216 mm) 26.8 x 15.8 x 8.5 in. (681 x 402 x 216 mm) (including DC disconnect) 41.6 x 21.4 x 8.5 in. (1057 x 544 x 216 mm) 39.4 x 23.6 x 9.1 in. (1001 x 600 x 232 mm) Side Facing: 78.2 x 50-53 x 33 in. (1987 x 1270-1347 x 839 mm) (width dependent upon rating of disconnect chosen)
Forward Facing: 78.2 x 79-88 x 33 in. (1987 x 2007-2236 x 839 mm) (width dependent upon rating of disconnect chosen) 79 x 109 x 41 in. (2007 x 2769 x 1042 mm) 82 x 109 x 41 in. (2083 mm x 2769 mm x 1042 mm)
Weight 43 lbs (19.5 kg) 65 lbs (29.5 kg) 141 lbs (64 kg) 132 lbs (60 kg) 104 lbs (47.2 kg) 124.5 lbs (56.5 kg) 1450 lbs (658 kg) 1875 lbs (851 kg) 5170 lbs (2346 kg) 5650 lbs (2563 kg) 6980 lbs (3167 kg); PE Model: 7107 lbs (3224 kg) 3410 lbs (1547 kg) 3080 lbs (1398 kg) 3570 lbs (1620 kg)
Enclosure Rating Type 4 + Salt Mist Corrosion Protection Type 4 Type 3R Type 3R Type 3R
Enclosure Finish & Material Aluminum Polyester powder coated aluminum Polyester powder coated steel; Optional 316 stainless steel Polyester powder coated steel; Optional 316 stainless steel Polyester powder coated steel; Optional 316 stainless steel
GRID-TIED PV INVERTER OVERVIEWPVI 50KW PVI 60KW PVI 75KWPVI 20TL PVI 85KW PVI 100KW SGI 225 SGI 250 SGI 266 SGI 300 SGI 500/PE SGI 500XTPVI 14TL PVI 23TL PVI 28TL SGI 500XTM SGI 750XTM
Copyright © Solectria - A Yaskawa Company. All information subject to change without notice. March 2015 DOCR-070256-E
PVI 7600TLPVI 6600TLPVI 5200TLPVI 3800TL
For more detailed specifications, go to www.solectria.com/documentation.
MEGAWATT SOLAR STATIONS
Structural
Dimensions (L x W x H) Skid Enclosure
258 x 89.3 x 137 in. (6554 x 2269 x 3480 mm)312 x 120 x 138 in. (7925 x 3048 x 3506 mm
324 x 140 x 137 in. (8230 x 3556 x 3480 mm)−
Weight Skid Enclosure
30,000 lbs (13,608 kg)36,000 lbs (16,330 kg)
33,000 lbs (14,969 kg)39,000 lbs (17,691 kg) 35,000 lbs (15,876 kg)
37,000 lbs (16,783 kg)
37,500 lbs (17,010 kg)39,500 lbs (17,917 kg) 40,000 lbs (18,144 kg)
42,000 lbs (19,051 kg)45,000 lbs (20,412 kg)47,000 lbs (21,319 kg)
Color Frisco White; other colors optional Frisco White; other colors optional
Baseframe Structural steel; conforms to ASTM A36; shop welded Structural steel; conforms to ASTM A36; shop welded
Enclosure Type Skid or Enclosure Skid or Enclosure
Flooring (Enclosure)
3/4” (19 mm) fire rated plywood or 1” (25.4 mm) skid guard or 3/16” (4.8 mm) diamond tread
steel plate or 1/4” (6.4 mm) steel plate; insulation optional
3/4” (19 mm) fire rated plywood or 1” (25.4 mm) skid guard or 3/16” (4.8 mm) diamond tread steel plate or 1/4” (6.4 mm) steel plate; insulation optional
Walls (Enclosure) Post minium 14 gauge galvanized, shop welded to structural steel base frame & roof z-bracket Post minium 14 gauge galvanized, shop welded to structural steel base frame & roof z-bracket
Siding (Enclosure)Full length, tight fitted, weather tight &
weather proof; standard 0.040 gauge factory painted stucco aluminim
Full length, tight fitted, weather tight & weather proof; standard 0.040 gauge factory painted stucco aluminum
Roof (Enclosure)
Full length, tight fitted, weather tight & weather proof; EPDM membrane roof optional;
bows are c-style 16 gauge galvanized at 24” (610 mm); sloped at 1” (25.4 mm)
minimum pitch; insulation optional
Full length, tight fitted, weather tight & weather proof; EPDM membrane roof optional; bows are c-style 16 gauge galvanized at 24” (610 mm);
sloped at 1” (25.4 mm) minimum pitch; insulation optional
Door (Enclosure)Minimum 20 gauge hollow metal dorrs with R2.4
insulation; interior panic button; door closer; exterior drip strips
Minumum 20 gauge hollow metal doors with R2.4 insulation; interior panic button; door closer; exterior drip strips
Electrical
Lighting (Enclosure)Interior fluorescent lighting; 4 ft (1219 mm) or 8 ft
(2438 mm) T8 high output light fixtures; other light fixtures available
Interior fluorescent lighting; 4 ft (1219 mm) or 8 ft (2438 mm) T8 high output light fixtures; other light fixtures available
Conduit & Fittings Electrical metallic tubing (EMT) or flexible metal conduit; not less than 1/2 in. (12.7 mm) diameter
Electrical metallic tubing (EMT) or flexible metal conduit; not less than 1/2” (12.7 mm) diameter
Light Switches (Enclosure) 20 A, 250 V minimum (located at doors) 20 A, 250 V minimum (located at doors)
Receptacles20 A, 125 V single or duplex, listed weather tight
& approved for outdoor use; GFCI receptacles to be specified; cover plates are galvanized steel
20 A, 125 V single or duplex, listed weather tight & approved for outdoor use; GFCI receptacles to be specified; cover plates are galvanized steel
Wireways & Cables All MSS compnents are listed and station is in full compliance with the National Electric Code (NEC)
All MSS components are listed and station is in full compiance with the National Electric Code (NEC)
Medium Voltage Transformer
Nominal Output Power 500 kVA, 3-Ph 1000 kVA, 3-Ph 500 kVA, 3-Ph 750 kVA, 3-Ph 1000 kVA, 3-Ph 1500 kVA, 3-Ph
Utility Connection Voltage 2.5-35 kV 2.5-35 kV
Utility Connection kV Classes 15 kV / 25 kV / 35 kV 15 kV / 25 kV / 35 kV
Taps (2) 2.5% above & (2) below nominal (2) 2.5% above & (2) below nominal
Frequency 60 Hz 60 Hz
Inverter Output Voltage 208 VAC 380 VAC
Inverter Output kV Class 1.2 kV 1.2 kV
Cooling Class KNAN KNAN
Insulating Fluid Envirotemp FR3 Envirotemp FR3
Overcurrent Protection Partial range current-limiting fuses Partial range current-limiting fuses
Configuration Dead front and loop feed Dead front and loop feed
MSS 0.5MW-XT MSS 1MW-XT MSS 0.5MW-XTM MSS 1MW-XTM MSS 1.5MW-XTMPVI 36TL
*Please see combiner datasheet for complete subcombiner details
MSS 0.75MW-XTM
GRID TIED PV INVERTER OVERVIEW
DC Input
Absolute Maximum Input Voltage 600 VDC 600 VDC 1000 VDC 600 VDC 600 VDC 600 VDC 1000 VDC
Operating Input Voltage Range, MPPT 120-550 VDC 180-580 VDC 260-580 VDC 300-900 VDC 280-950 VDC300-500 VDC 300-500 VDC 300-500 VDC 545-820 VDC
Full Power Input Voltage Range, MPPT 200-500 VDC 300-540 VDC 300-550 VDC 480-800 VDC 500-800 VDC 520-800 VDC
Full Power Input Voltage Range, MPPT - Low Voltage Option − − 285-500 VDC − −
Maximum Operating Input Current 20 A 15 A per MPP tracker 18 A per MPP tracker 20 A per MPP tracker 25 A per MPP tracker (50 A) 35 A per MPP tracker (70 A) 25 A per MPP tracker (50 A) 29 A per MPP tracker (58 A) 34 A per MPPT (68 A) 176 A 211 A 264 A 299 A 351 A 768 A 853 A 908 A 1026 A 1721/1712 A 1750 A 965 A 1445 A
Max Operating Input Current - Low Voltage Option − − 185 A 222 A 278 A 314 A 370 A − −
Start Voltage 150 V 300 V 330 V 400 V 390 V 390 V 700 V
Start Voltage - Low Voltage Option − − 380 V − −
AC Output
Nominal Output Voltage 208 or 240 VAC, 1-Ph 208 VAC, 3-Ph 480 VAC, 3-Ph 208, 240, 480 or 600 VAC, 3-Ph (3-wire standard, 4-wire optional ) 480 VAC, 3-Ph 480 or 600 VAC, 3-Ph 480 VAC, 3-Ph (3-wire standard, 4-wire optional) 208 VAC, 3-Ph 380 VAC, 3-Ph
Continuous Output Power 3.3 kW (208 VAC); 3.8 kW (240 VAC) 5.2 kW (208 VAC); 5.2 kW (240 VAC) 6.6 kW (208 VAC); 6.6 kW (240 VAC) 6.6 kW (208 VAC); 7.6 kW (240 VAC) 14 kW 20 kW 23 kW 28 kW 36 kW 50 kW 60 kW 75 kW 85 kW 100 kW 225 kW 250 kW 266 kW 300 kW 500 kW 500 kW 750 kW
Continuous Output Current 15.8 A (208 VAC); 15.8 A (240 VAC) 25 A (208 VAC); 21.6 A (240 VAC) 31.7 A (208 VAC); 27.5 A (240 VAC) 31.7 A (208 VAC); 31.7 A (240 VAC) 39 A 24 A 27.7 A 33.7 A 43.3 A 139/120/60/48 A 167/144/72/58 A 208/180/90/72 A 236/205/102/82 A 278/240/120/96 A 271 A 301/240 A 320 A 360 A 602 A 1387 A 760 A 1140 A
Max Fault Contribution Current 140 A (peak) 70.4 A (RMS) 43.3 A (RMS) 69.6 A (RMS) − 167 A (208 VAC); 144 A (240 VAC); 72 A (480 VAC) (RMS)
200 A (208 VAC); 173 A (240 VAC); 86 A (480 VAC) (RMS)
250 A (208 VAC); 216 A (240 VAC); 108 A (480 VAC) (RMS)
283 A (208 VAC); 246 A (240 VAC); 122 A (480 VAC) (RMS)
334 A (208 VAC); 288 A (240 VAC); 144 A (480 VAC) (RMS) 325.2 A (RMS) 361.2 A (RMS) 384 A (RMS) 432 A (RMS) 722 A (RMS) 1665 A (RMS) 912 A (RMS) 1368 A (RMS)
Power Factor Unity, > 0.99 Unity, >0.99 (±0.8 adjustable) Unity, >0.99 (±0.9 adjustable) Unity, >0.99 (±0.8 adjustable) Adjustable - 0.9 to +0.9, factory set at 1 Adjustable - 0.9 to +0.9, factory set at 1 Adjustable - 0.9 to +0.9, factory set at 1 Adjustable - 0.8 to +0.8, factory set at 1
Efficiency
Peak Efficiency (208/240/480/600 VAC) 98.3% 96.9% 97.4% 98.6% 98.5% 96.7/97.7/96.5/96.5% 96.7/97.8/96.5/96.5% 97.3/97.1/97.2/97.2% 96.6/96.7/96.9/96.9% 96.5/96.9/96.9/96.9% 98.0% 97.9% 98.1% 98.3%
CEC Efficiency (208/240/480 VAC) 97.5% 96.0% 97.0% 98.0% 96.0/97.0/96.0% 97.0/96.0/97.0% 96.0/96.0/96.5% 97.5% 97.0% 98.0%
Tare Loss < 1 W 4 W 2 W 1 W < 3 W 28 W 32 W 41 W 89 W 123 W
Combiners
Subcombiner or Integrated String Combiner Integrated string combiner:2 strings per tracker (1 tracker) Integrated string combiner: 2 strings per tracker (2 trackers) Integrated string combiner: 4 strings per tracker (2 trackers), 15 A (fused by-pass available) Subcombiner: Fuses or breakers, 2-8 positions, 40-300 A* Subcombiner: Fuses or breakers, 6-24 positions, 70-400 A* Subcombiner: Fuses or breakers,
8-32 positions, 70-400 A*Subcominber: Fuses or breakers,
8-32 positions, 70-400 A*Subcombiner: Fuses, 4 to 16 positions, 100-400 A*
Subcombiner: Breakers, 4 to 15 positions, 125-350 A*
Temperature
Ambient Temperature Range (full power) -13°F to +122°F (-25°C to +50°C) -13°F to +140°F (-25°C to +60°C) Derating occurs over +50°C -13°F to +140°F (-25°C to +60°C) Derating occurs over +45°C -40°F to +131°F (-40°C to +55°C) -40°F to +122°F (-40°C to +50°C) -40°F to +122°F (-40°C to +50°C)
Storage Temperature Range -40°F to +185°F (-40°C to +85°C) -22°F to +158°F (-30°C to +70°C) -58°F to +158°F (-40°C to +70°C) -40°F to +131°F (-40°C to +55°C) -40°F to +158°F (-40°C to +70) -40°F to +122°F (-40°C to +50°C)
Data Monitoring
Optional SolrenView Web-Based Monitoring External Integrated Integrated Integrated Integrated
Optional Revenue Grade Monitoring External External External 400 A 800 A 1600 A 800 A 1600 A
Optional Sub-Array Monitoring (DC Current) − − 2-8 zones 6 zones 8 zones 8 zones 1 zone per protected input (up to 16 zones)
Optional Cellular Communication − − SolrenView AIR SolrenView AIR SolrenView AIR
External Communication Interface RS-485 RS-485 Modbus RTU RS-485 SunSpec Modbus RTU RS-485 SunSpec Modbus RTU RS-485 SunSpec Modbus RTU
Testing & Certifications
Safety Listings & Certifications UL 1741/IEEE 1547, UL 1699B, CSA C22.2#107.1, FCC part 15 A&B UL 1741/IEEE 1547, CSA C22.2#107.1, FCC part 15B UL 1741/IEEE 1547, CSA C22.2#107.1, FCC part 15B UL 1741/IEEE 1547, CSA C22.2#107.1, FCC part 15B UL 1741/IEEE 1547, CSA C22.2#107.1
Certification Agency ETL CSA ETL ETL ETL ETL
Warranty
Standard 10 year 10 year 5 year 5 year 5 year
Optional − 15, 20 year; extended service agreement 10, 15, 20 year; extended service agreement; uptime guarantee 10, 15, 20 year; extended service agreement; uptime guarantee 10, 15, 20 year; extended service agreement; uptime guarantee
Enclosure
dBA (Decibel) Rating < 45 dBA @ 3 m < 50 dBA @ 3 m < 62 dBA @ 3 m < 60 dBA @ 5 m < 59 dBA @ 3 m < 67 dBA @ 10 m
Transformer Transformerless Transformerless Standard, fully-integrated (internal) Standard, fully-integrated (internal); external optional Dedicated external transformer required, refer to external transformer specifications
AC/DC Disconnect DC disconnect, fully-integrated Standard, fully-integrated Standard, fully-integrated Fully-integrated (internal) DC disconnect: integrated, standard; AC disconnect/breaker: optional disconnect, breaker or breaker with shunt trip
Dimensions (H x W x D) 17.5 x 15.8 x 8.5 in. (445 x 402 x 216 mm) 26.8 x 15.8 x 8.5 in. (681 x 402 x 216 mm) (including DC disconnect) 41.6 x 21.4 x 8.5 in. (1057 x 544 x 216 mm) 39.4 x 23.6 x 9.1 in. (1001 x 600 x 232 mm) Side Facing: 78.2 x 50-53 x 33 in. (1987 x 1270-1347 x 839 mm) (width dependent upon rating of disconnect chosen)
Forward Facing: 78.2 x 79-88 x 33 in. (1987 x 2007-2236 x 839 mm) (width dependent upon rating of disconnect chosen) 79 x 109 x 41 in. (2007 x 2769 x 1042 mm) 82 x 109 x 41 in. (2083 mm x 2769 mm x 1042 mm)
Weight 43 lbs (19.5 kg) 65 lbs (29.5 kg) 141 lbs (64 kg) 132 lbs (60 kg) 104 lbs (47.2 kg) 124.5 lbs (56.5 kg) 1450 lbs (658 kg) 1875 lbs (851 kg) 5170 lbs (2346 kg) 5650 lbs (2563 kg) 6980 lbs (3167 kg); PE Model: 7107 lbs (3224 kg) 3410 lbs (1547 kg) 3080 lbs (1398 kg) 3570 lbs (1620 kg)
Enclosure Rating Type 4 + Salt Mist Corrosion Protection Type 4 Type 3R Type 3R Type 3R
Enclosure Finish & Material Aluminum Polyester powder coated aluminum Polyester powder coated steel; Optional 316 stainless steel Polyester powder coated steel; Optional 316 stainless steel Polyester powder coated steel; Optional 316 stainless steel
GRID-TIED PV INVERTER OVERVIEWPVI 50KW PVI 60KW PVI 75KWPVI 20TL PVI 85KW PVI 100KW SGI 225 SGI 250 SGI 266 SGI 300 SGI 500/PE SGI 500XTPVI 14TL PVI 23TL PVI 28TL SGI 500XTM SGI 750XTM
Copyright © Solectria - A Yaskawa Company. All information subject to change without notice. March 2015 DOCR-070256-E
PVI 7600TLPVI 6600TLPVI 5200TLPVI 3800TL
For more detailed specifications, go to www.solectria.com/documentation.
MEGAWATT SOLAR STATIONS
Structural
Dimensions (L x W x H) Skid Enclosure
258 x 89.3 x 137 in. (6554 x 2269 x 3480 mm)312 x 120 x 138 in. (7925 x 3048 x 3506 mm
324 x 140 x 137 in. (8230 x 3556 x 3480 mm)−
Weight Skid Enclosure
30,000 lbs (13,608 kg)36,000 lbs (16,330 kg)
33,000 lbs (14,969 kg)39,000 lbs (17,691 kg) 35,000 lbs (15,876 kg)
37,000 lbs (16,783 kg)
37,500 lbs (17,010 kg)39,500 lbs (17,917 kg) 40,000 lbs (18,144 kg)
42,000 lbs (19,051 kg)45,000 lbs (20,412 kg)47,000 lbs (21,319 kg)
Color Frisco White; other colors optional Frisco White; other colors optional
Baseframe Structural steel; conforms to ASTM A36; shop welded Structural steel; conforms to ASTM A36; shop welded
Enclosure Type Skid or Enclosure Skid or Enclosure
Flooring (Enclosure)
3/4” (19 mm) fire rated plywood or 1” (25.4 mm) skid guard or 3/16” (4.8 mm) diamond tread
steel plate or 1/4” (6.4 mm) steel plate; insulation optional
3/4” (19 mm) fire rated plywood or 1” (25.4 mm) skid guard or 3/16” (4.8 mm) diamond tread steel plate or 1/4” (6.4 mm) steel plate; insulation optional
Walls (Enclosure) Post minium 14 gauge galvanized, shop welded to structural steel base frame & roof z-bracket Post minium 14 gauge galvanized, shop welded to structural steel base frame & roof z-bracket
Siding (Enclosure)Full length, tight fitted, weather tight &
weather proof; standard 0.040 gauge factory painted stucco aluminim
Full length, tight fitted, weather tight & weather proof; standard 0.040 gauge factory painted stucco aluminum
Roof (Enclosure)
Full length, tight fitted, weather tight & weather proof; EPDM membrane roof optional;
bows are c-style 16 gauge galvanized at 24” (610 mm); sloped at 1” (25.4 mm)
minimum pitch; insulation optional
Full length, tight fitted, weather tight & weather proof; EPDM membrane roof optional; bows are c-style 16 gauge galvanized at 24” (610 mm);
sloped at 1” (25.4 mm) minimum pitch; insulation optional
Door (Enclosure)Minimum 20 gauge hollow metal dorrs with R2.4
insulation; interior panic button; door closer; exterior drip strips
Minumum 20 gauge hollow metal doors with R2.4 insulation; interior panic button; door closer; exterior drip strips
Electrical
Lighting (Enclosure)Interior fluorescent lighting; 4 ft (1219 mm) or 8 ft
(2438 mm) T8 high output light fixtures; other light fixtures available
Interior fluorescent lighting; 4 ft (1219 mm) or 8 ft (2438 mm) T8 high output light fixtures; other light fixtures available
Conduit & Fittings Electrical metallic tubing (EMT) or flexible metal conduit; not less than 1/2 in. (12.7 mm) diameter
Electrical metallic tubing (EMT) or flexible metal conduit; not less than 1/2” (12.7 mm) diameter
Light Switches (Enclosure) 20 A, 250 V minimum (located at doors) 20 A, 250 V minimum (located at doors)
Receptacles20 A, 125 V single or duplex, listed weather tight
& approved for outdoor use; GFCI receptacles to be specified; cover plates are galvanized steel
20 A, 125 V single or duplex, listed weather tight & approved for outdoor use; GFCI receptacles to be specified; cover plates are galvanized steel
Wireways & Cables All MSS compnents are listed and station is in full compliance with the National Electric Code (NEC)
All MSS components are listed and station is in full compiance with the National Electric Code (NEC)
Medium Voltage Transformer
Nominal Output Power 500 kVA, 3-Ph 1000 kVA, 3-Ph 500 kVA, 3-Ph 750 kVA, 3-Ph 1000 kVA, 3-Ph 1500 kVA, 3-Ph
Utility Connection Voltage 2.5-35 kV 2.5-35 kV
Utility Connection kV Classes 15 kV / 25 kV / 35 kV 15 kV / 25 kV / 35 kV
Taps (2) 2.5% above & (2) below nominal (2) 2.5% above & (2) below nominal
Frequency 60 Hz 60 Hz
Inverter Output Voltage 208 VAC 380 VAC
Inverter Output kV Class 1.2 kV 1.2 kV
Cooling Class KNAN KNAN
Insulating Fluid Envirotemp FR3 Envirotemp FR3
Overcurrent Protection Partial range current-limiting fuses Partial range current-limiting fuses
Configuration Dead front and loop feed Dead front and loop feed
MSS 0.5MW-XT MSS 1MW-XT MSS 0.5MW-XTM MSS 1MW-XTM MSS 1.5MW-XTMPVI 36TL
*Please see combiner datasheet for complete subcombiner details
MSS 0.75MW-XTM
DC Input
Absolute Maximum Input Voltage 600 VDC 600 VDC 1000 VDC 600 VDC 600 VDC 600 VDC 1000 VDC
Operating Input Voltage Range, MPPT 120-550 VDC 180-580 VDC 260-580 VDC 300-900 VDC 280-950 VDC300-500 VDC 300-500 VDC 300-500 VDC 545-820 VDC
Full Power Input Voltage Range, MPPT 200-500 VDC 300-540 VDC 300-550 VDC 480-800 VDC 500-800 VDC 520-800 VDC
Full Power Input Voltage Range, MPPT - Low Voltage Option − − 285-500 VDC − −
Maximum Operating Input Current 20 A 15 A per MPP tracker 18 A per MPP tracker 20 A per MPP tracker 25 A per MPP tracker (50 A) 35 A per MPP tracker (70 A) 25 A per MPP tracker (50 A) 29 A per MPP tracker (58 A) 34 A per MPPT (68 A) 176 A 211 A 264 A 299 A 351 A 768 A 853 A 908 A 1026 A 1721/1712 A 1750 A 965 A 1445 A
Max Operating Input Current - Low Voltage Option − − 185 A 222 A 278 A 314 A 370 A − −
Start Voltage 150 V 300 V 330 V 400 V 390 V 390 V 700 V
Start Voltage - Low Voltage Option − − 380 V − −
AC Output
Nominal Output Voltage 208 or 240 VAC, 1-Ph 208 VAC, 3-Ph 480 VAC, 3-Ph 208, 240, 480 or 600 VAC, 3-Ph (3-wire standard, 4-wire optional ) 480 VAC, 3-Ph 480 or 600 VAC, 3-Ph 480 VAC, 3-Ph (3-wire standard, 4-wire optional) 208 VAC, 3-Ph 380 VAC, 3-Ph
Continuous Output Power 3.3 kW (208 VAC); 3.8 kW (240 VAC) 5.2 kW (208 VAC); 5.2 kW (240 VAC) 6.6 kW (208 VAC); 6.6 kW (240 VAC) 6.6 kW (208 VAC); 7.6 kW (240 VAC) 14 kW 20 kW 23 kW 28 kW 36 kW 50 kW 60 kW 75 kW 85 kW 100 kW 225 kW 250 kW 266 kW 300 kW 500 kW 500 kW 750 kW
Continuous Output Current 15.8 A (208 VAC); 15.8 A (240 VAC) 25 A (208 VAC); 21.6 A (240 VAC) 31.7 A (208 VAC); 27.5 A (240 VAC) 31.7 A (208 VAC); 31.7 A (240 VAC) 39 A 24 A 27.7 A 33.7 A 43.3 A 139/120/60/48 A 167/144/72/58 A 208/180/90/72 A 236/205/102/82 A 278/240/120/96 A 271 A 301/240 A 320 A 360 A 602 A 1387 A 760 A 1140 A
Max Fault Contribution Current 140 A (peak) 70.4 A (RMS) 43.3 A (RMS) 69.6 A (RMS) − 167 A (208 VAC); 144 A (240 VAC); 72 A (480 VAC) (RMS)
200 A (208 VAC); 173 A (240 VAC); 86 A (480 VAC) (RMS)
250 A (208 VAC); 216 A (240 VAC); 108 A (480 VAC) (RMS)
283 A (208 VAC); 246 A (240 VAC); 122 A (480 VAC) (RMS)
334 A (208 VAC); 288 A (240 VAC); 144 A (480 VAC) (RMS) 325.2 A (RMS) 361.2 A (RMS) 384 A (RMS) 432 A (RMS) 722 A (RMS) 1665 A (RMS) 912 A (RMS) 1368 A (RMS)
Power Factor Unity, > 0.99 Unity, >0.99 (±0.8 adjustable) Unity, >0.99 (±0.9 adjustable) Unity, >0.99 (±0.8 adjustable) Adjustable - 0.9 to +0.9, factory set at 1 Adjustable - 0.9 to +0.9, factory set at 1 Adjustable - 0.9 to +0.9, factory set at 1 Adjustable - 0.8 to +0.8, factory set at 1
Efficiency
Peak Efficiency (208/240/480/600 VAC) 98.3% 96.9% 97.4% 98.6% 98.5% 96.7/97.7/96.5/96.5% 96.7/97.8/96.5/96.5% 97.3/97.1/97.2/97.2% 96.6/96.7/96.9/96.9% 96.5/96.9/96.9/96.9% 98.0% 97.9% 98.1% 98.3%
CEC Efficiency (208/240/480 VAC) 97.5% 96.0% 97.0% 98.0% 96.0/97.0/96.0% 97.0/96.0/97.0% 96.0/96.0/96.5% 97.5% 97.0% 98.0%
Tare Loss < 1 W 4 W 2 W 1 W < 3 W 28 W 32 W 41 W 89 W 123 W
Combiners
Subcombiner or Integrated String Combiner Integrated string combiner:2 strings per tracker (1 tracker) Integrated string combiner: 2 strings per tracker (2 trackers) Integrated string combiner: 4 strings per tracker (2 trackers), 15 A (fused by-pass available) Subcombiner: Fuses or breakers, 2-8 positions, 40-300 A* Subcombiner: Fuses or breakers, 6-24 positions, 70-400 A* Subcombiner: Fuses or breakers,
8-32 positions, 70-400 A*Subcominber: Fuses or breakers,
8-32 positions, 70-400 A*Subcombiner: Fuses, 4 to 16 positions, 100-400 A*
Subcombiner: Breakers, 4 to 15 positions, 125-350 A*
Temperature
Ambient Temperature Range (full power) -13°F to +122°F (-25°C to +50°C) -13°F to +140°F (-25°C to +60°C) Derating occurs over +50°C -13°F to +140°F (-25°C to +60°C) Derating occurs over +45°C -40°F to +131°F (-40°C to +55°C) -40°F to +122°F (-40°C to +50°C) -40°F to +122°F (-40°C to +50°C)
Storage Temperature Range -40°F to +185°F (-40°C to +85°C) -22°F to +158°F (-30°C to +70°C) -58°F to +158°F (-40°C to +70°C) -40°F to +131°F (-40°C to +55°C) -40°F to +158°F (-40°C to +70) -40°F to +122°F (-40°C to +50°C)
Data Monitoring
Optional SolrenView Web-Based Monitoring External Integrated Integrated Integrated Integrated
Optional Revenue Grade Monitoring External External External 400 A 800 A 1600 A 800 A 1600 A
Optional Sub-Array Monitoring (DC Current) − − 2-8 zones 6 zones 8 zones 8 zones 1 zone per protected input (up to 16 zones)
Optional Cellular Communication − − SolrenView AIR SolrenView AIR SolrenView AIR
External Communication Interface RS-485 RS-485 Modbus RTU RS-485 SunSpec Modbus RTU RS-485 SunSpec Modbus RTU RS-485 SunSpec Modbus RTU
Testing & Certifications
Safety Listings & Certifications UL 1741/IEEE 1547, UL 1699B, CSA C22.2#107.1, FCC part 15 A&B UL 1741/IEEE 1547, CSA C22.2#107.1, FCC part 15B UL 1741/IEEE 1547, CSA C22.2#107.1, FCC part 15B UL 1741/IEEE 1547, CSA C22.2#107.1, FCC part 15B UL 1741/IEEE 1547, CSA C22.2#107.1
Certification Agency ETL CSA ETL ETL ETL ETL
Warranty
Standard 10 year 10 year 5 year 5 year 5 year
Optional − 15, 20 year; extended service agreement 10, 15, 20 year; extended service agreement; uptime guarantee 10, 15, 20 year; extended service agreement; uptime guarantee 10, 15, 20 year; extended service agreement; uptime guarantee
Enclosure
dBA (Decibel) Rating < 45 dBA @ 3 m < 50 dBA @ 3 m < 62 dBA @ 3 m < 60 dBA @ 5 m < 59 dBA @ 3 m < 67 dBA @ 10 m
Transformer Transformerless Transformerless Standard, fully-integrated (internal) Standard, fully-integrated (internal); external optional Dedicated external transformer required, refer to external transformer specifications
AC/DC Disconnect DC disconnect, fully-integrated Standard, fully-integrated Standard, fully-integrated Fully-integrated (internal) DC disconnect: integrated, standard; AC disconnect/breaker: optional disconnect, breaker or breaker with shunt trip
Dimensions (H x W x D) 17.5 x 15.8 x 8.5 in. (445 x 402 x 216 mm) 26.8 x 15.8 x 8.5 in. (681 x 402 x 216 mm) (including DC disconnect) 41.6 x 21.4 x 8.5 in. (1057 x 544 x 216 mm) 39.4 x 23.6 x 9.1 in. (1001 x 600 x 232 mm) Side Facing: 78.2 x 50-53 x 33 in. (1987 x 1270-1347 x 839 mm) (width dependent upon rating of disconnect chosen)
Forward Facing: 78.2 x 79-88 x 33 in. (1987 x 2007-2236 x 839 mm) (width dependent upon rating of disconnect chosen) 79 x 109 x 41 in. (2007 x 2769 x 1042 mm) 82 x 109 x 41 in. (2083 mm x 2769 mm x 1042 mm)
Weight 43 lbs (19.5 kg) 65 lbs (29.5 kg) 141 lbs (64 kg) 132 lbs (60 kg) 104 lbs (47.2 kg) 124.5 lbs (56.5 kg) 1450 lbs (658 kg) 1875 lbs (851 kg) 5170 lbs (2346 kg) 5650 lbs (2563 kg) 6980 lbs (3167 kg); PE Model: 7107 lbs (3224 kg) 3410 lbs (1547 kg) 3080 lbs (1398 kg) 3570 lbs (1620 kg)
Enclosure Rating Type 4 + Salt Mist Corrosion Protection Type 4 Type 3R Type 3R Type 3R
Enclosure Finish & Material Aluminum Polyester powder coated aluminum Polyester powder coated steel; Optional 316 stainless steel Polyester powder coated steel; Optional 316 stainless steel Polyester powder coated steel; Optional 316 stainless steel
GRID-TIED PV INVERTER OVERVIEWPVI 50KW PVI 60KW PVI 75KWPVI 20TL PVI 85KW PVI 100KW SGI 225 SGI 250 SGI 266 SGI 300 SGI 500/PE SGI 500XTPVI 14TL PVI 23TL PVI 28TL SGI 500XTM SGI 750XTM
Copyright © Solectria - A Yaskawa Company. All information subject to change without notice. March 2015 DOCR-070256-E
PVI 7600TLPVI 6600TLPVI 5200TLPVI 3800TL
For more detailed specifications, go to www.solectria.com/documentation.
MEGAWATT SOLAR STATIONS
Structural
Dimensions (L x W x H) Skid Enclosure
258 x 89.3 x 137 in. (6554 x 2269 x 3480 mm)312 x 120 x 138 in. (7925 x 3048 x 3506 mm
324 x 140 x 137 in. (8230 x 3556 x 3480 mm)−
Weight Skid Enclosure
30,000 lbs (13,608 kg)36,000 lbs (16,330 kg)
33,000 lbs (14,969 kg)39,000 lbs (17,691 kg) 35,000 lbs (15,876 kg)
37,000 lbs (16,783 kg)
37,500 lbs (17,010 kg)39,500 lbs (17,917 kg) 40,000 lbs (18,144 kg)
42,000 lbs (19,051 kg)45,000 lbs (20,412 kg)47,000 lbs (21,319 kg)
Color Frisco White; other colors optional Frisco White; other colors optional
Baseframe Structural steel; conforms to ASTM A36; shop welded Structural steel; conforms to ASTM A36; shop welded
Enclosure Type Skid or Enclosure Skid or Enclosure
Flooring (Enclosure)
3/4” (19 mm) fire rated plywood or 1” (25.4 mm) skid guard or 3/16” (4.8 mm) diamond tread
steel plate or 1/4” (6.4 mm) steel plate; insulation optional
3/4” (19 mm) fire rated plywood or 1” (25.4 mm) skid guard or 3/16” (4.8 mm) diamond tread steel plate or 1/4” (6.4 mm) steel plate; insulation optional
Walls (Enclosure) Post minium 14 gauge galvanized, shop welded to structural steel base frame & roof z-bracket Post minium 14 gauge galvanized, shop welded to structural steel base frame & roof z-bracket
Siding (Enclosure)Full length, tight fitted, weather tight &
weather proof; standard 0.040 gauge factory painted stucco aluminim
Full length, tight fitted, weather tight & weather proof; standard 0.040 gauge factory painted stucco aluminum
Roof (Enclosure)
Full length, tight fitted, weather tight & weather proof; EPDM membrane roof optional;
bows are c-style 16 gauge galvanized at 24” (610 mm); sloped at 1” (25.4 mm)
minimum pitch; insulation optional
Full length, tight fitted, weather tight & weather proof; EPDM membrane roof optional; bows are c-style 16 gauge galvanized at 24” (610 mm);
sloped at 1” (25.4 mm) minimum pitch; insulation optional
Door (Enclosure)Minimum 20 gauge hollow metal dorrs with R2.4
insulation; interior panic button; door closer; exterior drip strips
Minumum 20 gauge hollow metal doors with R2.4 insulation; interior panic button; door closer; exterior drip strips
Electrical
Lighting (Enclosure)Interior fluorescent lighting; 4 ft (1219 mm) or 8 ft
(2438 mm) T8 high output light fixtures; other light fixtures available
Interior fluorescent lighting; 4 ft (1219 mm) or 8 ft (2438 mm) T8 high output light fixtures; other light fixtures available
Conduit & Fittings Electrical metallic tubing (EMT) or flexible metal conduit; not less than 1/2 in. (12.7 mm) diameter
Electrical metallic tubing (EMT) or flexible metal conduit; not less than 1/2” (12.7 mm) diameter
Light Switches (Enclosure) 20 A, 250 V minimum (located at doors) 20 A, 250 V minimum (located at doors)
Receptacles20 A, 125 V single or duplex, listed weather tight
& approved for outdoor use; GFCI receptacles to be specified; cover plates are galvanized steel
20 A, 125 V single or duplex, listed weather tight & approved for outdoor use; GFCI receptacles to be specified; cover plates are galvanized steel
Wireways & Cables All MSS compnents are listed and station is in full compliance with the National Electric Code (NEC)
All MSS components are listed and station is in full compiance with the National Electric Code (NEC)
Medium Voltage Transformer
Nominal Output Power 500 kVA, 3-Ph 1000 kVA, 3-Ph 500 kVA, 3-Ph 750 kVA, 3-Ph 1000 kVA, 3-Ph 1500 kVA, 3-Ph
Utility Connection Voltage 2.5-35 kV 2.5-35 kV
Utility Connection kV Classes 15 kV / 25 kV / 35 kV 15 kV / 25 kV / 35 kV
Taps (2) 2.5% above & (2) below nominal (2) 2.5% above & (2) below nominal
Frequency 60 Hz 60 Hz
Inverter Output Voltage 208 VAC 380 VAC
Inverter Output kV Class 1.2 kV 1.2 kV
Cooling Class KNAN KNAN
Insulating Fluid Envirotemp FR3 Envirotemp FR3
Overcurrent Protection Partial range current-limiting fuses Partial range current-limiting fuses
Configuration Dead front and loop feed Dead front and loop feed
MSS 0.5MW-XT MSS 1MW-XT MSS 0.5MW-XTM MSS 1MW-XTM MSS 1.5MW-XTMPVI 36TL
*Please see combiner datasheet for complete subcombiner details
MSS 0.75MW-XTM
DC Input
Absolute Maximum Input Voltage 600 VDC 600 VDC 1000 VDC 600 VDC 600 VDC 600 VDC 1000 VDC
Operating Input Voltage Range, MPPT 120-550 VDC 180-580 VDC 260-580 VDC 300-900 VDC 280-950 VDC300-500 VDC 300-500 VDC 300-500 VDC 545-820 VDC
Full Power Input Voltage Range, MPPT 200-500 VDC 300-540 VDC 300-550 VDC 480-800 VDC 500-800 VDC 520-800 VDC
Full Power Input Voltage Range, MPPT - Low Voltage Option − − 285-500 VDC − −
Maximum Operating Input Current 20 A 15 A per MPP tracker 18 A per MPP tracker 20 A per MPP tracker 25 A per MPP tracker (50 A) 35 A per MPP tracker (70 A) 25 A per MPP tracker (50 A) 29 A per MPP tracker (58 A) 34 A per MPPT (68 A) 176 A 211 A 264 A 299 A 351 A 768 A 853 A 908 A 1026 A 1721/1712 A 1750 A 965 A 1445 A
Max Operating Input Current - Low Voltage Option − − 185 A 222 A 278 A 314 A 370 A − −
Start Voltage 150 V 300 V 330 V 400 V 390 V 390 V 700 V
Start Voltage - Low Voltage Option − − 380 V − −
AC Output
Nominal Output Voltage 208 or 240 VAC, 1-Ph 208 VAC, 3-Ph 480 VAC, 3-Ph 208, 240, 480 or 600 VAC, 3-Ph (3-wire standard, 4-wire optional ) 480 VAC, 3-Ph 480 or 600 VAC, 3-Ph 480 VAC, 3-Ph (3-wire standard, 4-wire optional) 208 VAC, 3-Ph 380 VAC, 3-Ph
Continuous Output Power 3.3 kW (208 VAC); 3.8 kW (240 VAC) 5.2 kW (208 VAC); 5.2 kW (240 VAC) 6.6 kW (208 VAC); 6.6 kW (240 VAC) 6.6 kW (208 VAC); 7.6 kW (240 VAC) 14 kW 20 kW 23 kW 28 kW 36 kW 50 kW 60 kW 75 kW 85 kW 100 kW 225 kW 250 kW 266 kW 300 kW 500 kW 500 kW 750 kW
Continuous Output Current 15.8 A (208 VAC); 15.8 A (240 VAC) 25 A (208 VAC); 21.6 A (240 VAC) 31.7 A (208 VAC); 27.5 A (240 VAC) 31.7 A (208 VAC); 31.7 A (240 VAC) 39 A 24 A 27.7 A 33.7 A 43.3 A 139/120/60/48 A 167/144/72/58 A 208/180/90/72 A 236/205/102/82 A 278/240/120/96 A 271 A 301/240 A 320 A 360 A 602 A 1387 A 760 A 1140 A
Max Fault Contribution Current 140 A (peak) 70.4 A (RMS) 43.3 A (RMS) 69.6 A (RMS) − 167 A (208 VAC); 144 A (240 VAC); 72 A (480 VAC) (RMS)
200 A (208 VAC); 173 A (240 VAC); 86 A (480 VAC) (RMS)
250 A (208 VAC); 216 A (240 VAC); 108 A (480 VAC) (RMS)
283 A (208 VAC); 246 A (240 VAC); 122 A (480 VAC) (RMS)
334 A (208 VAC); 288 A (240 VAC); 144 A (480 VAC) (RMS) 325.2 A (RMS) 361.2 A (RMS) 384 A (RMS) 432 A (RMS) 722 A (RMS) 1665 A (RMS) 912 A (RMS) 1368 A (RMS)
Power Factor Unity, > 0.99 Unity, >0.99 (±0.8 adjustable) Unity, >0.99 (±0.9 adjustable) Unity, >0.99 (±0.8 adjustable) Adjustable - 0.9 to +0.9, factory set at 1 Adjustable - 0.9 to +0.9, factory set at 1 Adjustable - 0.9 to +0.9, factory set at 1 Adjustable - 0.8 to +0.8, factory set at 1
Efficiency
Peak Efficiency (208/240/480/600 VAC) 98.3% 96.9% 97.4% 98.6% 98.5% 96.7/97.7/96.5/96.5% 96.7/97.8/96.5/96.5% 97.3/97.1/97.2/97.2% 96.6/96.7/96.9/96.9% 96.5/96.9/96.9/96.9% 98.0% 97.9% 98.1% 98.3%
CEC Efficiency (208/240/480 VAC) 97.5% 96.0% 97.0% 98.0% 96.0/97.0/96.0% 97.0/96.0/97.0% 96.0/96.0/96.5% 97.5% 97.0% 98.0%
Tare Loss < 1 W 4 W 2 W 1 W < 3 W 28 W 32 W 41 W 89 W 123 W
Combiners
Subcombiner or Integrated String Combiner Integrated string combiner:2 strings per tracker (1 tracker) Integrated string combiner: 2 strings per tracker (2 trackers) Integrated string combiner: 4 strings per tracker (2 trackers), 15 A (fused by-pass available) Subcombiner: Fuses or breakers, 2-8 positions, 40-300 A* Subcombiner: Fuses or breakers, 6-24 positions, 70-400 A* Subcombiner: Fuses or breakers,
8-32 positions, 70-400 A*Subcominber: Fuses or breakers,
8-32 positions, 70-400 A*Subcombiner: Fuses, 4 to 16 positions, 100-400 A*
Subcombiner: Breakers, 4 to 15 positions, 125-350 A*
Temperature
Ambient Temperature Range (full power) -13°F to +122°F (-25°C to +50°C) -13°F to +140°F (-25°C to +60°C) Derating occurs over +50°C -13°F to +140°F (-25°C to +60°C) Derating occurs over +45°C -40°F to +131°F (-40°C to +55°C) -40°F to +122°F (-40°C to +50°C) -40°F to +122°F (-40°C to +50°C)
Storage Temperature Range -40°F to +185°F (-40°C to +85°C) -22°F to +158°F (-30°C to +70°C) -58°F to +158°F (-40°C to +70°C) -40°F to +131°F (-40°C to +55°C) -40°F to +158°F (-40°C to +70) -40°F to +122°F (-40°C to +50°C)
Data Monitoring
Optional SolrenView Web-Based Monitoring External Integrated Integrated Integrated Integrated
Optional Revenue Grade Monitoring External External External 400 A 800 A 1600 A 800 A 1600 A
Optional Sub-Array Monitoring (DC Current) − − 2-8 zones 6 zones 8 zones 8 zones 1 zone per protected input (up to 16 zones)
Optional Cellular Communication − − SolrenView AIR SolrenView AIR SolrenView AIR
External Communication Interface RS-485 RS-485 Modbus RTU RS-485 SunSpec Modbus RTU RS-485 SunSpec Modbus RTU RS-485 SunSpec Modbus RTU
Testing & Certifications
Safety Listings & Certifications UL 1741/IEEE 1547, UL 1699B, CSA C22.2#107.1, FCC part 15 A&B UL 1741/IEEE 1547, CSA C22.2#107.1, FCC part 15B UL 1741/IEEE 1547, CSA C22.2#107.1, FCC part 15B UL 1741/IEEE 1547, CSA C22.2#107.1, FCC part 15B UL 1741/IEEE 1547, CSA C22.2#107.1
Certification Agency ETL CSA ETL ETL ETL ETL
Warranty
Standard 10 year 10 year 5 year 5 year 5 year
Optional − 15, 20 year; extended service agreement 10, 15, 20 year; extended service agreement; uptime guarantee 10, 15, 20 year; extended service agreement; uptime guarantee 10, 15, 20 year; extended service agreement; uptime guarantee
Enclosure
dBA (Decibel) Rating < 45 dBA @ 3 m < 50 dBA @ 3 m < 62 dBA @ 3 m < 60 dBA @ 5 m < 59 dBA @ 3 m < 67 dBA @ 10 m
Transformer Transformerless Transformerless Standard, fully-integrated (internal) Standard, fully-integrated (internal); external optional Dedicated external transformer required, refer to external transformer specifications
AC/DC Disconnect DC disconnect, fully-integrated Standard, fully-integrated Standard, fully-integrated Fully-integrated (internal) DC disconnect: integrated, standard; AC disconnect/breaker: optional disconnect, breaker or breaker with shunt trip
Dimensions (H x W x D) 17.5 x 15.8 x 8.5 in. (445 x 402 x 216 mm) 26.8 x 15.8 x 8.5 in. (681 x 402 x 216 mm) (including DC disconnect) 41.6 x 21.4 x 8.5 in. (1057 x 544 x 216 mm) 39.4 x 23.6 x 9.1 in. (1001 x 600 x 232 mm) Side Facing: 78.2 x 50-53 x 33 in. (1987 x 1270-1347 x 839 mm) (width dependent upon rating of disconnect chosen)
Forward Facing: 78.2 x 79-88 x 33 in. (1987 x 2007-2236 x 839 mm) (width dependent upon rating of disconnect chosen) 79 x 109 x 41 in. (2007 x 2769 x 1042 mm) 82 x 109 x 41 in. (2083 mm x 2769 mm x 1042 mm)
Weight 43 lbs (19.5 kg) 65 lbs (29.5 kg) 141 lbs (64 kg) 132 lbs (60 kg) 104 lbs (47.2 kg) 124.5 lbs (56.5 kg) 1450 lbs (658 kg) 1875 lbs (851 kg) 5170 lbs (2346 kg) 5650 lbs (2563 kg) 6980 lbs (3167 kg); PE Model: 7107 lbs (3224 kg) 3410 lbs (1547 kg) 3080 lbs (1398 kg) 3570 lbs (1620 kg)
Enclosure Rating Type 4 + Salt Mist Corrosion Protection Type 4 Type 3R Type 3R Type 3R
Enclosure Finish & Material Aluminum Polyester powder coated aluminum Polyester powder coated steel; Optional 316 stainless steel Polyester powder coated steel; Optional 316 stainless steel Polyester powder coated steel; Optional 316 stainless steel
GRID-TIED PV INVERTER OVERVIEWPVI 50KW PVI 60KW PVI 75KWPVI 20TL PVI 85KW PVI 100KW SGI 225 SGI 250 SGI 266 SGI 300 SGI 500/PE SGI 500XTPVI 14TL PVI 23TL PVI 28TL SGI 500XTM SGI 750XTM
Copyright © Solectria - A Yaskawa Company. All information subject to change without notice. March 2015 DOCR-070256-E
PVI 7600TLPVI 6600TLPVI 5200TLPVI 3800TL
For more detailed specifications, go to www.solectria.com/documentation.
MEGAWATT SOLAR STATIONS
Structural
Dimensions (L x W x H) Skid Enclosure
258 x 89.3 x 137 in. (6554 x 2269 x 3480 mm)312 x 120 x 138 in. (7925 x 3048 x 3506 mm
324 x 140 x 137 in. (8230 x 3556 x 3480 mm)−
Weight Skid Enclosure
30,000 lbs (13,608 kg)36,000 lbs (16,330 kg)
33,000 lbs (14,969 kg)39,000 lbs (17,691 kg) 35,000 lbs (15,876 kg)
37,000 lbs (16,783 kg)
37,500 lbs (17,010 kg)39,500 lbs (17,917 kg) 40,000 lbs (18,144 kg)
42,000 lbs (19,051 kg)45,000 lbs (20,412 kg)47,000 lbs (21,319 kg)
Color Frisco White; other colors optional Frisco White; other colors optional
Baseframe Structural steel; conforms to ASTM A36; shop welded Structural steel; conforms to ASTM A36; shop welded
Enclosure Type Skid or Enclosure Skid or Enclosure
Flooring (Enclosure)
3/4” (19 mm) fire rated plywood or 1” (25.4 mm) skid guard or 3/16” (4.8 mm) diamond tread
steel plate or 1/4” (6.4 mm) steel plate; insulation optional
3/4” (19 mm) fire rated plywood or 1” (25.4 mm) skid guard or 3/16” (4.8 mm) diamond tread steel plate or 1/4” (6.4 mm) steel plate; insulation optional
Walls (Enclosure) Post minium 14 gauge galvanized, shop welded to structural steel base frame & roof z-bracket Post minium 14 gauge galvanized, shop welded to structural steel base frame & roof z-bracket
Siding (Enclosure)Full length, tight fitted, weather tight &
weather proof; standard 0.040 gauge factory painted stucco aluminim
Full length, tight fitted, weather tight & weather proof; standard 0.040 gauge factory painted stucco aluminum
Roof (Enclosure)
Full length, tight fitted, weather tight & weather proof; EPDM membrane roof optional;
bows are c-style 16 gauge galvanized at 24” (610 mm); sloped at 1” (25.4 mm)
minimum pitch; insulation optional
Full length, tight fitted, weather tight & weather proof; EPDM membrane roof optional; bows are c-style 16 gauge galvanized at 24” (610 mm);
sloped at 1” (25.4 mm) minimum pitch; insulation optional
Door (Enclosure)Minimum 20 gauge hollow metal dorrs with R2.4
insulation; interior panic button; door closer; exterior drip strips
Minumum 20 gauge hollow metal doors with R2.4 insulation; interior panic button; door closer; exterior drip strips
Electrical
Lighting (Enclosure)Interior fluorescent lighting; 4 ft (1219 mm) or 8 ft
(2438 mm) T8 high output light fixtures; other light fixtures available
Interior fluorescent lighting; 4 ft (1219 mm) or 8 ft (2438 mm) T8 high output light fixtures; other light fixtures available
Conduit & Fittings Electrical metallic tubing (EMT) or flexible metal conduit; not less than 1/2 in. (12.7 mm) diameter
Electrical metallic tubing (EMT) or flexible metal conduit; not less than 1/2” (12.7 mm) diameter
Light Switches (Enclosure) 20 A, 250 V minimum (located at doors) 20 A, 250 V minimum (located at doors)
Receptacles20 A, 125 V single or duplex, listed weather tight
& approved for outdoor use; GFCI receptacles to be specified; cover plates are galvanized steel
20 A, 125 V single or duplex, listed weather tight & approved for outdoor use; GFCI receptacles to be specified; cover plates are galvanized steel
Wireways & Cables All MSS compnents are listed and station is in full compliance with the National Electric Code (NEC)
All MSS components are listed and station is in full compiance with the National Electric Code (NEC)
Medium Voltage Transformer
Nominal Output Power 500 kVA, 3-Ph 1000 kVA, 3-Ph 500 kVA, 3-Ph 750 kVA, 3-Ph 1000 kVA, 3-Ph 1500 kVA, 3-Ph
Utility Connection Voltage 2.5-35 kV 2.5-35 kV
Utility Connection kV Classes 15 kV / 25 kV / 35 kV 15 kV / 25 kV / 35 kV
Taps (2) 2.5% above & (2) below nominal (2) 2.5% above & (2) below nominal
Frequency 60 Hz 60 Hz
Inverter Output Voltage 208 VAC 380 VAC
Inverter Output kV Class 1.2 kV 1.2 kV
Cooling Class KNAN KNAN
Insulating Fluid Envirotemp FR3 Envirotemp FR3
Overcurrent Protection Partial range current-limiting fuses Partial range current-limiting fuses
Configuration Dead front and loop feed Dead front and loop feed
MSS 0.5MW-XT MSS 1MW-XT MSS 0.5MW-XTM MSS 1MW-XTM MSS 1.5MW-XTMPVI 36TL
*Please see combiner datasheet for complete subcombiner details
MSS 0.75MW-XTM
DC Input
Absolute Maximum Input Voltage 600 VDC 600 VDC 1000 VDC 600 VDC 600 VDC 600 VDC 1000 VDC
Operating Input Voltage Range, MPPT 120-550 VDC 180-580 VDC 260-580 VDC 300-900 VDC 280-950 VDC300-500 VDC 300-500 VDC 300-500 VDC 545-820 VDC
Full Power Input Voltage Range, MPPT 200-500 VDC 300-540 VDC 300-550 VDC 480-800 VDC 500-800 VDC 520-800 VDC
Full Power Input Voltage Range, MPPT - Low Voltage Option − − 285-500 VDC − −
Maximum Operating Input Current 20 A 15 A per MPP tracker 18 A per MPP tracker 20 A per MPP tracker 25 A per MPP tracker (50 A) 35 A per MPP tracker (70 A) 25 A per MPP tracker (50 A) 29 A per MPP tracker (58 A) 34 A per MPPT (68 A) 176 A 211 A 264 A 299 A 351 A 768 A 853 A 908 A 1026 A 1721/1712 A 1750 A 965 A 1445 A
Max Operating Input Current - Low Voltage Option − − 185 A 222 A 278 A 314 A 370 A − −
Start Voltage 150 V 300 V 330 V 400 V 390 V 390 V 700 V
Start Voltage - Low Voltage Option − − 380 V − −
AC Output
Nominal Output Voltage 208 or 240 VAC, 1-Ph 208 VAC, 3-Ph 480 VAC, 3-Ph 208, 240, 480 or 600 VAC, 3-Ph (3-wire standard, 4-wire optional ) 480 VAC, 3-Ph 480 or 600 VAC, 3-Ph 480 VAC, 3-Ph (3-wire standard, 4-wire optional) 208 VAC, 3-Ph 380 VAC, 3-Ph
Continuous Output Power 3.3 kW (208 VAC); 3.8 kW (240 VAC) 5.2 kW (208 VAC); 5.2 kW (240 VAC) 6.6 kW (208 VAC); 6.6 kW (240 VAC) 6.6 kW (208 VAC); 7.6 kW (240 VAC) 14 kW 20 kW 23 kW 28 kW 36 kW 50 kW 60 kW 75 kW 85 kW 100 kW 225 kW 250 kW 266 kW 300 kW 500 kW 500 kW 750 kW
Continuous Output Current 15.8 A (208 VAC); 15.8 A (240 VAC) 25 A (208 VAC); 21.6 A (240 VAC) 31.7 A (208 VAC); 27.5 A (240 VAC) 31.7 A (208 VAC); 31.7 A (240 VAC) 39 A 24 A 27.7 A 33.7 A 43.3 A 139/120/60/48 A 167/144/72/58 A 208/180/90/72 A 236/205/102/82 A 278/240/120/96 A 271 A 301/240 A 320 A 360 A 602 A 1387 A 760 A 1140 A
Max Fault Contribution Current 140 A (peak) 70.4 A (RMS) 43.3 A (RMS) 69.6 A (RMS) − 167 A (208 VAC); 144 A (240 VAC); 72 A (480 VAC) (RMS)
200 A (208 VAC); 173 A (240 VAC); 86 A (480 VAC) (RMS)
250 A (208 VAC); 216 A (240 VAC); 108 A (480 VAC) (RMS)
283 A (208 VAC); 246 A (240 VAC); 122 A (480 VAC) (RMS)
334 A (208 VAC); 288 A (240 VAC); 144 A (480 VAC) (RMS) 325.2 A (RMS) 361.2 A (RMS) 384 A (RMS) 432 A (RMS) 722 A (RMS) 1665 A (RMS) 912 A (RMS) 1368 A (RMS)
Power Factor Unity, > 0.99 Unity, >0.99 (±0.8 adjustable) Unity, >0.99 (±0.9 adjustable) Unity, >0.99 (±0.8 adjustable) Adjustable - 0.9 to +0.9, factory set at 1 Adjustable - 0.9 to +0.9, factory set at 1 Adjustable - 0.9 to +0.9, factory set at 1 Adjustable - 0.8 to +0.8, factory set at 1
Efficiency
Peak Efficiency (208/240/480/600 VAC) 98.3% 96.9% 97.4% 98.6% 98.5% 96.7/97.7/96.5/96.5% 96.7/97.8/96.5/96.5% 97.3/97.1/97.2/97.2% 96.6/96.7/96.9/96.9% 96.5/96.9/96.9/96.9% 98.0% 97.9% 98.1% 98.3%
CEC Efficiency (208/240/480 VAC) 97.5% 96.0% 97.0% 98.0% 96.0/97.0/96.0% 97.0/96.0/97.0% 96.0/96.0/96.5% 97.5% 97.0% 98.0%
Tare Loss < 1 W 4 W 2 W 1 W < 3 W 28 W 32 W 41 W 89 W 123 W
Combiners
Subcombiner or Integrated String Combiner Integrated string combiner:2 strings per tracker (1 tracker) Integrated string combiner: 2 strings per tracker (2 trackers) Integrated string combiner: 4 strings per tracker (2 trackers), 15 A (fused by-pass available) Subcombiner: Fuses or breakers, 2-8 positions, 40-300 A* Subcombiner: Fuses or breakers, 6-24 positions, 70-400 A* Subcombiner: Fuses or breakers,
8-32 positions, 70-400 A*Subcominber: Fuses or breakers,
8-32 positions, 70-400 A*Subcombiner: Fuses, 4 to 16 positions, 100-400 A*
Subcombiner: Breakers, 4 to 15 positions, 125-350 A*
Temperature
Ambient Temperature Range (full power) -13°F to +122°F (-25°C to +50°C) -13°F to +140°F (-25°C to +60°C) Derating occurs over +50°C -13°F to +140°F (-25°C to +60°C) Derating occurs over +45°C -40°F to +131°F (-40°C to +55°C) -40°F to +122°F (-40°C to +50°C) -40°F to +122°F (-40°C to +50°C)
Storage Temperature Range -40°F to +185°F (-40°C to +85°C) -22°F to +158°F (-30°C to +70°C) -58°F to +158°F (-40°C to +70°C) -40°F to +131°F (-40°C to +55°C) -40°F to +158°F (-40°C to +70) -40°F to +122°F (-40°C to +50°C)
Data Monitoring
Optional SolrenView Web-Based Monitoring External Integrated Integrated Integrated Integrated
Optional Revenue Grade Monitoring External External External 400 A 800 A 1600 A 800 A 1600 A
Optional Sub-Array Monitoring (DC Current) − − 2-8 zones 6 zones 8 zones 8 zones 1 zone per protected input (up to 16 zones)
Optional Cellular Communication − − SolrenView AIR SolrenView AIR SolrenView AIR
External Communication Interface RS-485 RS-485 Modbus RTU RS-485 SunSpec Modbus RTU RS-485 SunSpec Modbus RTU RS-485 SunSpec Modbus RTU
Testing & Certifications
Safety Listings & Certifications UL 1741/IEEE 1547, UL 1699B, CSA C22.2#107.1, FCC part 15 A&B UL 1741/IEEE 1547, CSA C22.2#107.1, FCC part 15B UL 1741/IEEE 1547, CSA C22.2#107.1, FCC part 15B UL 1741/IEEE 1547, CSA C22.2#107.1, FCC part 15B UL 1741/IEEE 1547, CSA C22.2#107.1
Certification Agency ETL CSA ETL ETL ETL ETL
Warranty
Standard 10 year 10 year 5 year 5 year 5 year
Optional − 15, 20 year; extended service agreement 10, 15, 20 year; extended service agreement; uptime guarantee 10, 15, 20 year; extended service agreement; uptime guarantee 10, 15, 20 year; extended service agreement; uptime guarantee
Enclosure
dBA (Decibel) Rating < 45 dBA @ 3 m < 50 dBA @ 3 m < 62 dBA @ 3 m < 60 dBA @ 5 m < 59 dBA @ 3 m < 67 dBA @ 10 m
Transformer Transformerless Transformerless Standard, fully-integrated (internal) Standard, fully-integrated (internal); external optional Dedicated external transformer required, refer to external transformer specifications
AC/DC Disconnect DC disconnect, fully-integrated Standard, fully-integrated Standard, fully-integrated Fully-integrated (internal) DC disconnect: integrated, standard; AC disconnect/breaker: optional disconnect, breaker or breaker with shunt trip
Dimensions (H x W x D) 17.5 x 15.8 x 8.5 in. (445 x 402 x 216 mm) 26.8 x 15.8 x 8.5 in. (681 x 402 x 216 mm) (including DC disconnect) 41.6 x 21.4 x 8.5 in. (1057 x 544 x 216 mm) 39.4 x 23.6 x 9.1 in. (1001 x 600 x 232 mm) Side Facing: 78.2 x 50-53 x 33 in. (1987 x 1270-1347 x 839 mm) (width dependent upon rating of disconnect chosen)
Forward Facing: 78.2 x 79-88 x 33 in. (1987 x 2007-2236 x 839 mm) (width dependent upon rating of disconnect chosen) 79 x 109 x 41 in. (2007 x 2769 x 1042 mm) 82 x 109 x 41 in. (2083 mm x 2769 mm x 1042 mm)
Weight 43 lbs (19.5 kg) 65 lbs (29.5 kg) 141 lbs (64 kg) 132 lbs (60 kg) 104 lbs (47.2 kg) 124.5 lbs (56.5 kg) 1450 lbs (658 kg) 1875 lbs (851 kg) 5170 lbs (2346 kg) 5650 lbs (2563 kg) 6980 lbs (3167 kg); PE Model: 7107 lbs (3224 kg) 3410 lbs (1547 kg) 3080 lbs (1398 kg) 3570 lbs (1620 kg)
Enclosure Rating Type 4 + Salt Mist Corrosion Protection Type 4 Type 3R Type 3R Type 3R
Enclosure Finish & Material Aluminum Polyester powder coated aluminum Polyester powder coated steel; Optional 316 stainless steel Polyester powder coated steel; Optional 316 stainless steel Polyester powder coated steel; Optional 316 stainless steel
GRID-TIED PV INVERTER OVERVIEWPVI 50KW PVI 60KW PVI 75KWPVI 20TL PVI 85KW PVI 100KW SGI 225 SGI 250 SGI 266 SGI 300 SGI 500/PE SGI 500XTPVI 14TL PVI 23TL PVI 28TL SGI 500XTM SGI 750XTM
Copyright © Solectria - A Yaskawa Company. All information subject to change without notice. March 2015 DOCR-070256-E
PVI 7600TLPVI 6600TLPVI 5200TLPVI 3800TL
For more detailed specifications, go to www.solectria.com/documentation.
MEGAWATT SOLAR STATIONS
Structural
Dimensions (L x W x H) Skid Enclosure
258 x 89.3 x 137 in. (6554 x 2269 x 3480 mm)312 x 120 x 138 in. (7925 x 3048 x 3506 mm
324 x 140 x 137 in. (8230 x 3556 x 3480 mm)−
Weight Skid Enclosure
30,000 lbs (13,608 kg)36,000 lbs (16,330 kg)
33,000 lbs (14,969 kg)39,000 lbs (17,691 kg) 35,000 lbs (15,876 kg)
37,000 lbs (16,783 kg)
37,500 lbs (17,010 kg)39,500 lbs (17,917 kg) 40,000 lbs (18,144 kg)
42,000 lbs (19,051 kg)45,000 lbs (20,412 kg)47,000 lbs (21,319 kg)
Color Frisco White; other colors optional Frisco White; other colors optional
Baseframe Structural steel; conforms to ASTM A36; shop welded Structural steel; conforms to ASTM A36; shop welded
Enclosure Type Skid or Enclosure Skid or Enclosure
Flooring (Enclosure)
3/4” (19 mm) fire rated plywood or 1” (25.4 mm) skid guard or 3/16” (4.8 mm) diamond tread
steel plate or 1/4” (6.4 mm) steel plate; insulation optional
3/4” (19 mm) fire rated plywood or 1” (25.4 mm) skid guard or 3/16” (4.8 mm) diamond tread steel plate or 1/4” (6.4 mm) steel plate; insulation optional
Walls (Enclosure) Post minium 14 gauge galvanized, shop welded to structural steel base frame & roof z-bracket Post minium 14 gauge galvanized, shop welded to structural steel base frame & roof z-bracket
Siding (Enclosure)Full length, tight fitted, weather tight &
weather proof; standard 0.040 gauge factory painted stucco aluminim
Full length, tight fitted, weather tight & weather proof; standard 0.040 gauge factory painted stucco aluminum
Roof (Enclosure)
Full length, tight fitted, weather tight & weather proof; EPDM membrane roof optional;
bows are c-style 16 gauge galvanized at 24” (610 mm); sloped at 1” (25.4 mm)
minimum pitch; insulation optional
Full length, tight fitted, weather tight & weather proof; EPDM membrane roof optional; bows are c-style 16 gauge galvanized at 24” (610 mm);
sloped at 1” (25.4 mm) minimum pitch; insulation optional
Door (Enclosure)Minimum 20 gauge hollow metal dorrs with R2.4
insulation; interior panic button; door closer; exterior drip strips
Minumum 20 gauge hollow metal doors with R2.4 insulation; interior panic button; door closer; exterior drip strips
Electrical
Lighting (Enclosure)Interior fluorescent lighting; 4 ft (1219 mm) or 8 ft
(2438 mm) T8 high output light fixtures; other light fixtures available
Interior fluorescent lighting; 4 ft (1219 mm) or 8 ft (2438 mm) T8 high output light fixtures; other light fixtures available
Conduit & Fittings Electrical metallic tubing (EMT) or flexible metal conduit; not less than 1/2 in. (12.7 mm) diameter
Electrical metallic tubing (EMT) or flexible metal conduit; not less than 1/2” (12.7 mm) diameter
Light Switches (Enclosure) 20 A, 250 V minimum (located at doors) 20 A, 250 V minimum (located at doors)
Receptacles20 A, 125 V single or duplex, listed weather tight
& approved for outdoor use; GFCI receptacles to be specified; cover plates are galvanized steel
20 A, 125 V single or duplex, listed weather tight & approved for outdoor use; GFCI receptacles to be specified; cover plates are galvanized steel
Wireways & Cables All MSS compnents are listed and station is in full compliance with the National Electric Code (NEC)
All MSS components are listed and station is in full compiance with the National Electric Code (NEC)
Medium Voltage Transformer
Nominal Output Power 500 kVA, 3-Ph 1000 kVA, 3-Ph 500 kVA, 3-Ph 750 kVA, 3-Ph 1000 kVA, 3-Ph 1500 kVA, 3-Ph
Utility Connection Voltage 2.5-35 kV 2.5-35 kV
Utility Connection kV Classes 15 kV / 25 kV / 35 kV 15 kV / 25 kV / 35 kV
Taps (2) 2.5% above & (2) below nominal (2) 2.5% above & (2) below nominal
Frequency 60 Hz 60 Hz
Inverter Output Voltage 208 VAC 380 VAC
Inverter Output kV Class 1.2 kV 1.2 kV
Cooling Class KNAN KNAN
Insulating Fluid Envirotemp FR3 Envirotemp FR3
Overcurrent Protection Partial range current-limiting fuses Partial range current-limiting fuses
Configuration Dead front and loop feed Dead front and loop feed
MSS 0.5MW-XT MSS 1MW-XT MSS 0.5MW-XTM MSS 1MW-XTM MSS 1.5MW-XTMPVI 36TL
*Please see combiner datasheet for complete subcombiner details
MSS 0.75MW-XTM
DC Input
Absolute Maximum Input Voltage 600 VDC 600 VDC 1000 VDC 600 VDC 600 VDC 600 VDC 1000 VDC
Operating Input Voltage Range, MPPT 120-550 VDC 180-580 VDC 260-580 VDC 300-900 VDC 280-950 VDC300-500 VDC 300-500 VDC 300-500 VDC 545-820 VDC
Full Power Input Voltage Range, MPPT 200-500 VDC 300-540 VDC 300-550 VDC 480-800 VDC 500-800 VDC 520-800 VDC
Full Power Input Voltage Range, MPPT - Low Voltage Option − − 285-500 VDC − −
Maximum Operating Input Current 20 A 15 A per MPP tracker 18 A per MPP tracker 20 A per MPP tracker 25 A per MPP tracker (50 A) 35 A per MPP tracker (70 A) 25 A per MPP tracker (50 A) 29 A per MPP tracker (58 A) 34 A per MPPT (68 A) 176 A 211 A 264 A 299 A 351 A 768 A 853 A 908 A 1026 A 1721/1712 A 1750 A 965 A 1445 A
Max Operating Input Current - Low Voltage Option − − 185 A 222 A 278 A 314 A 370 A − −
Start Voltage 150 V 300 V 330 V 400 V 390 V 390 V 700 V
Start Voltage - Low Voltage Option − − 380 V − −
AC Output
Nominal Output Voltage 208 or 240 VAC, 1-Ph 208 VAC, 3-Ph 480 VAC, 3-Ph 208, 240, 480 or 600 VAC, 3-Ph (3-wire standard, 4-wire optional ) 480 VAC, 3-Ph 480 or 600 VAC, 3-Ph 480 VAC, 3-Ph (3-wire standard, 4-wire optional) 208 VAC, 3-Ph 380 VAC, 3-Ph
Continuous Output Power 3.3 kW (208 VAC); 3.8 kW (240 VAC) 5.2 kW (208 VAC); 5.2 kW (240 VAC) 6.6 kW (208 VAC); 6.6 kW (240 VAC) 6.6 kW (208 VAC); 7.6 kW (240 VAC) 14 kW 20 kW 23 kW 28 kW 36 kW 50 kW 60 kW 75 kW 85 kW 100 kW 225 kW 250 kW 266 kW 300 kW 500 kW 500 kW 750 kW
Continuous Output Current 15.8 A (208 VAC); 15.8 A (240 VAC) 25 A (208 VAC); 21.6 A (240 VAC) 31.7 A (208 VAC); 27.5 A (240 VAC) 31.7 A (208 VAC); 31.7 A (240 VAC) 39 A 24 A 27.7 A 33.7 A 43.3 A 139/120/60/48 A 167/144/72/58 A 208/180/90/72 A 236/205/102/82 A 278/240/120/96 A 271 A 301/240 A 320 A 360 A 602 A 1387 A 760 A 1140 A
Max Fault Contribution Current 140 A (peak) 70.4 A (RMS) 43.3 A (RMS) 69.6 A (RMS) − 167 A (208 VAC); 144 A (240 VAC); 72 A (480 VAC) (RMS)
200 A (208 VAC); 173 A (240 VAC); 86 A (480 VAC) (RMS)
250 A (208 VAC); 216 A (240 VAC); 108 A (480 VAC) (RMS)
283 A (208 VAC); 246 A (240 VAC); 122 A (480 VAC) (RMS)
334 A (208 VAC); 288 A (240 VAC); 144 A (480 VAC) (RMS) 325.2 A (RMS) 361.2 A (RMS) 384 A (RMS) 432 A (RMS) 722 A (RMS) 1665 A (RMS) 912 A (RMS) 1368 A (RMS)
Power Factor Unity, > 0.99 Unity, >0.99 (±0.8 adjustable) Unity, >0.99 (±0.9 adjustable) Unity, >0.99 (±0.8 adjustable) Adjustable - 0.9 to +0.9, factory set at 1 Adjustable - 0.9 to +0.9, factory set at 1 Adjustable - 0.9 to +0.9, factory set at 1 Adjustable - 0.8 to +0.8, factory set at 1
Efficiency
Peak Efficiency (208/240/480/600 VAC) 98.3% 96.9% 97.4% 98.6% 98.5% 96.7/97.7/96.5/96.5% 96.7/97.8/96.5/96.5% 97.3/97.1/97.2/97.2% 96.6/96.7/96.9/96.9% 96.5/96.9/96.9/96.9% 98.0% 97.9% 98.1% 98.3%
CEC Efficiency (208/240/480 VAC) 97.5% 96.0% 97.0% 98.0% 96.0/97.0/96.0% 97.0/96.0/97.0% 96.0/96.0/96.5% 97.5% 97.0% 98.0%
Tare Loss < 1 W 4 W 2 W 1 W < 3 W 28 W 32 W 41 W 89 W 123 W
Combiners
Subcombiner or Integrated String Combiner Integrated string combiner:2 strings per tracker (1 tracker) Integrated string combiner: 2 strings per tracker (2 trackers) Integrated string combiner: 4 strings per tracker (2 trackers), 15 A (fused by-pass available) Subcombiner: Fuses or breakers, 2-8 positions, 40-300 A* Subcombiner: Fuses or breakers, 6-24 positions, 70-400 A* Subcombiner: Fuses or breakers,
8-32 positions, 70-400 A*Subcominber: Fuses or breakers,
8-32 positions, 70-400 A*Subcombiner: Fuses, 4 to 16 positions, 100-400 A*
Subcombiner: Breakers, 4 to 15 positions, 125-350 A*
Temperature
Ambient Temperature Range (full power) -13°F to +122°F (-25°C to +50°C) -13°F to +140°F (-25°C to +60°C) Derating occurs over +50°C -13°F to +140°F (-25°C to +60°C) Derating occurs over +45°C -40°F to +131°F (-40°C to +55°C) -40°F to +122°F (-40°C to +50°C) -40°F to +122°F (-40°C to +50°C)
Storage Temperature Range -40°F to +185°F (-40°C to +85°C) -22°F to +158°F (-30°C to +70°C) -58°F to +158°F (-40°C to +70°C) -40°F to +131°F (-40°C to +55°C) -40°F to +158°F (-40°C to +70) -40°F to +122°F (-40°C to +50°C)
Data Monitoring
Optional SolrenView Web-Based Monitoring External Integrated Integrated Integrated Integrated
Optional Revenue Grade Monitoring External External External 400 A 800 A 1600 A 800 A 1600 A
Optional Sub-Array Monitoring (DC Current) − − 2-8 zones 6 zones 8 zones 8 zones 1 zone per protected input (up to 16 zones)
Optional Cellular Communication − − SolrenView AIR SolrenView AIR SolrenView AIR
External Communication Interface RS-485 RS-485 Modbus RTU RS-485 SunSpec Modbus RTU RS-485 SunSpec Modbus RTU RS-485 SunSpec Modbus RTU
Testing & Certifications
Safety Listings & Certifications UL 1741/IEEE 1547, UL 1699B, CSA C22.2#107.1, FCC part 15 A&B UL 1741/IEEE 1547, CSA C22.2#107.1, FCC part 15B UL 1741/IEEE 1547, CSA C22.2#107.1, FCC part 15B UL 1741/IEEE 1547, CSA C22.2#107.1, FCC part 15B UL 1741/IEEE 1547, CSA C22.2#107.1
Certification Agency ETL CSA ETL ETL ETL ETL
Warranty
Standard 10 year 10 year 5 year 5 year 5 year
Optional − 15, 20 year; extended service agreement 10, 15, 20 year; extended service agreement; uptime guarantee 10, 15, 20 year; extended service agreement; uptime guarantee 10, 15, 20 year; extended service agreement; uptime guarantee
Enclosure
dBA (Decibel) Rating < 45 dBA @ 3 m < 50 dBA @ 3 m < 62 dBA @ 3 m < 60 dBA @ 5 m < 59 dBA @ 3 m < 67 dBA @ 10 m
Transformer Transformerless Transformerless Standard, fully-integrated (internal) Standard, fully-integrated (internal); external optional Dedicated external transformer required, refer to external transformer specifications
AC/DC Disconnect DC disconnect, fully-integrated Standard, fully-integrated Standard, fully-integrated Fully-integrated (internal) DC disconnect: integrated, standard; AC disconnect/breaker: optional disconnect, breaker or breaker with shunt trip
Dimensions (H x W x D) 17.5 x 15.8 x 8.5 in. (445 x 402 x 216 mm) 26.8 x 15.8 x 8.5 in. (681 x 402 x 216 mm) (including DC disconnect) 41.6 x 21.4 x 8.5 in. (1057 x 544 x 216 mm) 39.4 x 23.6 x 9.1 in. (1001 x 600 x 232 mm) Side Facing: 78.2 x 50-53 x 33 in. (1987 x 1270-1347 x 839 mm) (width dependent upon rating of disconnect chosen)
Forward Facing: 78.2 x 79-88 x 33 in. (1987 x 2007-2236 x 839 mm) (width dependent upon rating of disconnect chosen) 79 x 109 x 41 in. (2007 x 2769 x 1042 mm) 82 x 109 x 41 in. (2083 mm x 2769 mm x 1042 mm)
Weight 43 lbs (19.5 kg) 65 lbs (29.5 kg) 141 lbs (64 kg) 132 lbs (60 kg) 104 lbs (47.2 kg) 124.5 lbs (56.5 kg) 1450 lbs (658 kg) 1875 lbs (851 kg) 5170 lbs (2346 kg) 5650 lbs (2563 kg) 6980 lbs (3167 kg); PE Model: 7107 lbs (3224 kg) 3410 lbs (1547 kg) 3080 lbs (1398 kg) 3570 lbs (1620 kg)
Enclosure Rating Type 4 + Salt Mist Corrosion Protection Type 4 Type 3R Type 3R Type 3R
Enclosure Finish & Material Aluminum Polyester powder coated aluminum Polyester powder coated steel; Optional 316 stainless steel Polyester powder coated steel; Optional 316 stainless steel Polyester powder coated steel; Optional 316 stainless steel
GRID-TIED PV INVERTER OVERVIEWPVI 50KW PVI 60KW PVI 75KWPVI 20TL PVI 85KW PVI 100KW SGI 225 SGI 250 SGI 266 SGI 300 SGI 500/PE SGI 500XTPVI 14TL PVI 23TL PVI 28TL SGI 500XTM SGI 750XTM
Copyright © Solectria - A Yaskawa Company. All information subject to change without notice. March 2015 DOCR-070256-E
PVI 7600TLPVI 6600TLPVI 5200TLPVI 3800TL
For more detailed specifications, go to www.solectria.com/documentation.
MEGAWATT SOLAR STATIONS
Structural
Dimensions (L x W x H) Skid Enclosure
258 x 89.3 x 137 in. (6554 x 2269 x 3480 mm)312 x 120 x 138 in. (7925 x 3048 x 3506 mm
324 x 140 x 137 in. (8230 x 3556 x 3480 mm)−
Weight Skid Enclosure
30,000 lbs (13,608 kg)36,000 lbs (16,330 kg)
33,000 lbs (14,969 kg)39,000 lbs (17,691 kg) 35,000 lbs (15,876 kg)
37,000 lbs (16,783 kg)
37,500 lbs (17,010 kg)39,500 lbs (17,917 kg) 40,000 lbs (18,144 kg)
42,000 lbs (19,051 kg)45,000 lbs (20,412 kg)47,000 lbs (21,319 kg)
Color Frisco White; other colors optional Frisco White; other colors optional
Baseframe Structural steel; conforms to ASTM A36; shop welded Structural steel; conforms to ASTM A36; shop welded
Enclosure Type Skid or Enclosure Skid or Enclosure
Flooring (Enclosure)
3/4” (19 mm) fire rated plywood or 1” (25.4 mm) skid guard or 3/16” (4.8 mm) diamond tread
steel plate or 1/4” (6.4 mm) steel plate; insulation optional
3/4” (19 mm) fire rated plywood or 1” (25.4 mm) skid guard or 3/16” (4.8 mm) diamond tread steel plate or 1/4” (6.4 mm) steel plate; insulation optional
Walls (Enclosure) Post minium 14 gauge galvanized, shop welded to structural steel base frame & roof z-bracket Post minium 14 gauge galvanized, shop welded to structural steel base frame & roof z-bracket
Siding (Enclosure)Full length, tight fitted, weather tight &
weather proof; standard 0.040 gauge factory painted stucco aluminim
Full length, tight fitted, weather tight & weather proof; standard 0.040 gauge factory painted stucco aluminum
Roof (Enclosure)
Full length, tight fitted, weather tight & weather proof; EPDM membrane roof optional;
bows are c-style 16 gauge galvanized at 24” (610 mm); sloped at 1” (25.4 mm)
minimum pitch; insulation optional
Full length, tight fitted, weather tight & weather proof; EPDM membrane roof optional; bows are c-style 16 gauge galvanized at 24” (610 mm);
sloped at 1” (25.4 mm) minimum pitch; insulation optional
Door (Enclosure)Minimum 20 gauge hollow metal dorrs with R2.4
insulation; interior panic button; door closer; exterior drip strips
Minumum 20 gauge hollow metal doors with R2.4 insulation; interior panic button; door closer; exterior drip strips
Electrical
Lighting (Enclosure)Interior fluorescent lighting; 4 ft (1219 mm) or 8 ft
(2438 mm) T8 high output light fixtures; other light fixtures available
Interior fluorescent lighting; 4 ft (1219 mm) or 8 ft (2438 mm) T8 high output light fixtures; other light fixtures available
Conduit & Fittings Electrical metallic tubing (EMT) or flexible metal conduit; not less than 1/2 in. (12.7 mm) diameter
Electrical metallic tubing (EMT) or flexible metal conduit; not less than 1/2” (12.7 mm) diameter
Light Switches (Enclosure) 20 A, 250 V minimum (located at doors) 20 A, 250 V minimum (located at doors)
Receptacles20 A, 125 V single or duplex, listed weather tight
& approved for outdoor use; GFCI receptacles to be specified; cover plates are galvanized steel
20 A, 125 V single or duplex, listed weather tight & approved for outdoor use; GFCI receptacles to be specified; cover plates are galvanized steel
Wireways & Cables All MSS compnents are listed and station is in full compliance with the National Electric Code (NEC)
All MSS components are listed and station is in full compiance with the National Electric Code (NEC)
Medium Voltage Transformer
Nominal Output Power 500 kVA, 3-Ph 1000 kVA, 3-Ph 500 kVA, 3-Ph 750 kVA, 3-Ph 1000 kVA, 3-Ph 1500 kVA, 3-Ph
Utility Connection Voltage 2.5-35 kV 2.5-35 kV
Utility Connection kV Classes 15 kV / 25 kV / 35 kV 15 kV / 25 kV / 35 kV
Taps (2) 2.5% above & (2) below nominal (2) 2.5% above & (2) below nominal
Frequency 60 Hz 60 Hz
Inverter Output Voltage 208 VAC 380 VAC
Inverter Output kV Class 1.2 kV 1.2 kV
Cooling Class KNAN KNAN
Insulating Fluid Envirotemp FR3 Envirotemp FR3
Overcurrent Protection Partial range current-limiting fuses Partial range current-limiting fuses
Configuration Dead front and loop feed Dead front and loop feed
MSS 0.5MW-XT MSS 1MW-XT MSS 0.5MW-XTM MSS 1MW-XTM MSS 1.5MW-XTMPVI 36TL
*Please see combiner datasheet for complete subcombiner details
MSS 0.75MW-XTM
Specifications DISCOM ARCCOM
Number of Fused Inputs 8, 12, 16, 20, 24LT, 24, 30 8, 12, 16, 24
Input Wire Range 14-6 AWG 12-8 AWG
Output Wire Range
8
12
16
20
24LT
24
30
600/1000VDC: 6 AWG-350 kcmil1000VDC Option: (2) 1/0 AWG-(2) 300 kcmil
600/1000VDC: 6 AWG-350 kcmil1000VDC Option: (2) 1/0 AWG-(2) 300 kcmil
600 VDC: (2) 6 AWG-(2) 300kcmil1000VDC: (2) 1/0 AWG-(2) 600 kcmil
600VDC: (2) 6 AWG-(2) 300kcmil1000VDC: (2) 1/0 AWG-(2) 600 kcmil
600VDC: (2) 4 AWG-(2) 600 kcmil1000VDC: (2) 1/0 AWG-(2) 600 kcmil
600VDC: (2) 4 AWG-(2) 600 kcmil1000VDC: (2) 1/0 AWG-(2) 600 kcmil
600VDC: (2) 4 AWG-(2) 600 kcmil1000VDC: (2) 1/0 AWG-(2) 600 kcmil
(2) 1 AWG - (2) 600 kcmil*
(2) 1 AWG - (2) 600 kcmil *
(2) 1 AWG - (2) 600 kcmil*
−
−
(2) 3/0 kcmil - (2) 600 kcmil*
−
Maximum Voltage 600 or 1000 VDC 600 or 1000 VDC
Maximum Current 100, 200, 225, 225, 250, 400 A 96, 144, 192, 288 A
Fuse Range 4, 6, 8, 10, 12, 15 A (inquire about 20-30 A) 4, 6, 8, 10, 12, 15 A
Operating Temperature -40°F to +122°F (-40°C to +50°C) -40°F to +122°F (-40°C to +50°C)
Mounting Locations Indoor, Outdoor, Wall, Array, Rooftop - Vertical, Horizontal or Angled
Indoor, Outdoor, Wall, Array, Rooftop- Vertical or Horizontal
Certifications
Safety Listings & Certifications UL 1741, CSA C22.2#107.1 UL 1741, CSA C22.2#107.1, UL 1699B
Certification Agency ETL ETL
Warranty
Standard 5 year 5 year
Enclosure 8-12 / 16-20 / 24LT-30
Dimensions (H x W x D) Powder Coated Steel 316 Stainless Steel Fiberglass
20/24/30 x 16/20/24 x 6/6/8 in. (508/610/762 x 406/508/610 x 152/152/203 mm)
20/24/30 x 16/20/24 x 6/6/8 in. (508/610/762 x 406/508/610 x 152/152/203 mm)
20/24/30 x 16/20/24 x 8/8/8 in.(508/610/762 x 406/508/610 x 203/203/203 mm)
20 x 24 x 7 in. (508 x 610 x 178 mm)
20 x 24 x 7 in. (508 x 610 x 178 mm)
30 x 24 x 8 in(762 x 610 x 203 mm)
Weight Powder Coated Steel 316 Stainless Steel Fiberglass
29/36/75 lbs (13.2/15.5/34.1 kg)29/36/75 lbs (13.2/15.5/34.1 kg)
26/29.3/56 lbs (11.8/13.3/25.5 kg)
42/42/43/44 lbs (19/19/19.5/20kg)42/42/43/44 lbs (19/19/19.5/20kg)
39/39/35.3/25 lbs (17.7/17.7/16/11.3kg)
Enclosure Rating Type 4; Optional Type 4X Type 4; Optional Type 4X
EnclosurePolyester powder coated steel;
optional 316 stainless steel or fiberglass
Polyester powder coated steel; optional 316 stainless steel
or fiberglass
COMBINERSDISCONNECTING COMBINER AFDI COMBINER
For more detailed specifications, go to www.solectria.com/documentation.
*Inquire about option (code) for field-crimp lug plates for output terminals
Specifications
Maximum Open Circuit Voltage 600 VDC
PV Fuse Size 15 A included, 20 A maximum
Integrated String Combiner 2 positions per MPPT
Integrated Power Supply DC powered by the array (2.5W)
Fuse Range 15 A included, 20 A maximum
Operating Temperature -40°F to +158°F (-40°C to +70°C)
Mounting Locations Indoor, Outdoor, Wall, Array, Rooftop- Vertical, Horizontal or Angled
Certifications
Safety Listings & Certifications UL 1741, CSA C22.2#107.1
Certification Agency CSA
Warranty
Standard 10 year
Enclosure
Dimensions (H x W x D) 12.4 x 10 x 2.2 in (316 x 255 x 55.5 mm)*
Weight 6.6 lbs (3 kg)
Enclosure Rating Type 4X
Enclosure Aluminum
Compatibility
Compatible Products PVI 3800-7600TL
RESIDENTIAL RAPID SHUTDOWN COMBINER
*Dimensions do not include DC input wiring shown in photos; input wiring is included when RSD is ordered
360 Merrimack Street | Lawrence, MA 01843978-683-9700 | www.solectria.com